• Title/Summary/Keyword: Magnetic nerve stimulator

Search Result 13, Processing Time 0.02 seconds

The Magnetic Nerve Stimulator Using a Switching Mode Power Supply (스위칭전원을 이용한 자기신경자극기)

  • Lee, Su-Yeol;Lee, Seong-Geun;Lee, Jeong-Han
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.265-270
    • /
    • 1995
  • An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for chArging high voltage cApacitors, the weight and size of the magnetic net've stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec Experimental results of human nerve stimulations using the developed stimulator are presented.

  • PDF

Functional Neuromuscular Stimulation for Paraplegic Standing (FNS를 사용한 하반신마비자의 일어서기)

  • Khang, Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.1-4
    • /
    • 1990
  • An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented.

  • PDF

A Study on Realization of the Magnetic Nerve Stimulator (자기신경자극기 구현에 관한 연구)

  • Lee, Soo-Yeol;Lee, Seong-Keun;Yi, Jeong-Han
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.57-60
    • /
    • 1995
  • An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Experimental results of human nerve stimulations using developed stimulator are presented.

  • PDF

Magnetic Nerve Stimulation Coils with Magnetic Mirror Effect (자계 거울 효과를 이용한 신경 자극 코일)

  • 한병희;김기왕;김재곤;박태석;이수열;조민형;양종수;김정회
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.287-293
    • /
    • 2002
  • For non-contact nerve stimulations using time varying magnetic field, high amplitude current pulses have to be applied to a magnetic nerve stimulation coil. To increase the magnetic stimulation frequency we have to increase both power supply capacity and cooling capacity of the magnetic nerve stimulator. To alleviate these problems. we propose a new magnetic nerve stimulation coil design methods. Utilizing magnetic mirror effect of a ferro-magnetic plate attached to a magnetic stimulation coil. we have improved efficiency of the stimulation coil. We have analyzed magnetic mirror effect for various kinds of stimulation coils using the finite element method, and we present experimental results obtained with several kinds of stimulation coils.

Measurement of Magnetic Flux and Induced Current in Magnetic Stimulation for Urinary Incontinence Treatment (요실금 치료용 자기 자극기의 자속밀도 및 유도전류 측정)

  • Han, Byung-Hee;Choi, Kyung-Moo;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.318-326
    • /
    • 2009
  • A simple method for measuring magnetic flux and induced current in magnetic nerve stimulation for urinary incontinence treatment is proposed. Unlike electric nerve stimulation, direct measurement of the induced current in magnetic nerve stimulation is impossible. Since induced currents stimulate nerves or muscles in magnetic nerve stimulation, measuring induced current is very important in validating stimulation efficacy and securing safety. The magnetic flux measuring system is composed of 6 layers with pick-up coils of 7 by 7 in each layer, and the induced current measuring system is composed of 6 layers with 7 concentric circular coils in each layer. The proposed method can be used in the design or performance test of a magnetic nerve stimulator for many clinical applications such as urinary incontinence treatment, activation of peripheral nerves, and transcranial magnetic stimulation.

Development of Pocket Insertion style Magnetic Curer that Apply $2^{loop}\;3^{pulsed}$ Variable Magnetic type Probe for Urinary Treatment

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Result that study magnet nerve curer for treatment induced current generation and current of ion for development in main point incontinence, prostate, sphincter, nervous system, rigidity, headache, retrogression arthritis, ligament damage, Rheumatism arthritis, peripheral nerve etc., can classify by 4. Embodied do first, full bridge magnet occurrence chapter, and communication with PC is available, confirmed various action loops an experiment. Could confirm correct treatment probe second, woman and man disease person. Third, derived so that healing may be possible naturally by addition of apron form according to disease. Because composition of finally, treatment probe composes by act of negative plate form, manufacture is easy and cooling designed for easy direction. More superior result of cooling appeared than existing in incidental and ingredients, cooling efficiency, composition, complexity, convenience etc. that expense and composition manufacture very straightforwardly and experimental by 2 - Tank ways.

One Case of Facial Nerve Palsy in Herpes Zoster Oticus Treated with electromagnetic therapy stimulator(Whata153) (자기장과 전기 조합 자극기(Whata 153)를 이용한 이성대상포진 안면신경마비 치료 1례 보고)

  • Jo, Seong-Eun;Lee, Hyun
    • Journal of Haehwa Medicine
    • /
    • v.25 no.1
    • /
    • pp.53-62
    • /
    • 2016
  • Objectives : The purpose of this study was to report a case of a patient efficacy of electromagnetic acupuncture using Whata 153 in facial nerve palsy in Herpes zoster oticus. Methods : We treated the patient with magnetic acupuncture combined with electro-acupuncture. Acupuncture points were at the face (BL2, GB14, TE23, ST4, ST6, ST3). All the acupuncture points were stimulated with magnetic field and 4 of them were combined with electro-acupuncture. Results & Conclusions : The improvement of facial movement and symptom was evaluated by Yanagihara grading system(Y-system), House-Brackmann scale(HB scale) and Sunnybrook facial grading system(SFGS). After treatment, all of the scales(Y-system, HB scale and SFGS) and symptom of the patient were improved. From the above results, we suggest that magnetic acupuncture and electro-acupuncture might be effective on facial nerve palsy in Herpes zoster oticus.

Design and embodiment of variableness band style magnetic field nerve stimulation system that apply $1^{trigger}$ $2^{mode}$ magnetic field treatment Probe for disease treatment

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.411-416
    • /
    • 2008
  • When compose magnetic field curer by belt and band style and need by magnetic field ripple last month, produce self-discipline roof. Bred in muscle disease (lumbago, backbone disease, corpulence) back. Result that study, manufactured various variableness band style - magnetic field probe firstly. Can establish self-discipline treatment pulse price by disease secondly. Could seek correct variableness band punishment, - magnetic field probe relationship implementation and property in waist, and so on, shoulder, neck, arm, leg, ankle, wrist etc. by third. Could find variableness band style energy value that need in-magnetic field Probe's treatment by fourth. This research could design pulse of self-discipline in band form and apply each according to disease.

Chopper Application for Magnetic Stimulation

  • Choi, Sun-Seob;Lee, Sun-Min;Kim, Jun-Hyoung;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.213-220
    • /
    • 2010
  • Since the hypothalamus immediately reacts to a nerve by processing all the information from the human body and the external stimulus being conducted, it performs a significant role in internal secretion; thus, a diverse and rapid stimulus pulse is required. By detecting Zero Detector accurately via the application of AVR on-Chip (ATMEL) using commercial electricity, chopping generates a stimulus pulse to the brain using an IGBT gate to designate a new magnetic stimulation following treatment and diagnosis. To simplify and generate a diverse range of stimuli for the brain, chopping can be used as a free magnetic stimulator. Then, commercial frequency (60Hz) is chopped precisely at the first level of the leakage transformer to deliver an appropriate stimulus pulse towards the hypothalamus when necessary. Discharge becomes stable, and the chopping frequency and duty-ratio provide variety after authorizing a high-pressure chopping voltage at the second level of the magnetic stimulator. These methods have several aims. The first is to apply a variable stimulus pulse via accurate switching frequency control by a voltaic pulse or a pulse repetition rate, according to the diagnostic purpose for a given hypothalamus. Consequently, the efficiency tends to increase. This experiment was conducted at a maximum of 210 W, a magnetic induced amplitude of 0.1~2.5 Tesla, a pulse duration of $200{\sim}350\;{\mu}s$, magnetic inducement of 5 Hz, stimulus frequency of 0.1~60 Hz, and a duration of stimulus train of 1~10 sec.

A Case of Brachial Plexus Schwannoma

  • Kim, Young-Woo;Ahn, Sung-Ki;Song, Joon-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.5
    • /
    • pp.396-399
    • /
    • 2006
  • Brachial plexus schwannoma is rare. A case of a 28-year old woman who complained of a palpable mass in the right axilla is presented. She had previous incisional biopsy on the axillary mass. Brachial plexus magnetic resonance imaging revealed a well circumscribed contrast enhancing mass on the right distal cord of the brachial plexus. EMG revealed normal. Tumor resection was performed with the transaxillary approach. Though dense granulation tissue obscured normal brachial plexus nerve anatomy, using the surgical microscope and nerve stimulator, grossly total tumor resection was performed. She is free of any neurologic symptom at three months postoperatively.