• Title/Summary/Keyword: Magnetic fluids

Search Result 184, Processing Time 0.031 seconds

Synthesis and Properties of Ni-CNT Nanocomposites Using Electrical Explosion of Wire in Different Conditions

  • Maithili Biswas; Jin-Chun Kim
    • Korean Journal of Materials Research
    • /
    • v.34 no.3
    • /
    • pp.138-143
    • /
    • 2024
  • Ni-CNT nanocomposites were synthesized via the electrical explosion of wire (EEW) in acetone and deionized (DI) water liquid conditions with different CNT compositions. The change in the shape and properties of the Ni-CNT nanopowders were determined based on the type of fluids and CNT compositions. In every case, the Ni nanopowder had a spherical shape and the CNT powder had a tube shape. However, the Ni-CNT nanopowders obtained in DI water exhibited irregular shapes due to the oxidation of Ni. Phase analysis also revealed the existence of nickel oxide when using DI water, as well as some unknown peaks with acetone, which may form due to the metastable phase of Ni. Magnetic properties were investigated using a Vibrating Sample Magnetometer (VSM) for all cases. Nanopowders prepared in DI water conditions had better magnetic properties than those in acetone, as evidenced by the simultaneous formation of super paramagnetic NiO peaks and ferromagnetic Ni peaks. The DI water (Ni:CNT = 1:0.3) sample revealed better magnetic results than the DI water (Ni-CNT = 1:0.5) because it had less CNT contents.

A Modeling of a Variable-damping Mount Using Magneto-Rheological Fluid (자기점성유체를 이용한 가변감쇠 마운트의 모델화)

  • 안영공;양보석;삼하신
    • Journal of KSNVE
    • /
    • v.11 no.1
    • /
    • pp.141-146
    • /
    • 2001
  • This paper deals with an application of Magneto-Rheological (MR) fluid to a small size mount for precision equipment of automobiles. MR fluid is known as a class of functional fluids with controllable apparent viscosity of fluid by the applied magnetic field strength. A typical MR fluid is a suspension where pure iron particles of 1-20 (m in diameter are dispersed in a liquid such as mineral oil or silicone oil, at the concentration of 20 - 40 vol%. Electro magnetic coil is installed at the bottom of a variable-damping mount filled with MR fluid, and performance of the mount was investigated experimentally. Furthermore, the Properties of the MR Mount on experimental study were explained analytically by mechanical model of the MR mount.

  • PDF

A Study on High-output MR (Magneto-rheological) Brake for Tension Control (장력제어용 고출력 MR 브레이크)

  • Park, Jung-Ho;Kim, Jin-Gyu;Youn, Dong-Won;Ham, Sang-Yong;Noh, Jong-Ho;Yoo, Jin-San
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1422-1427
    • /
    • 2007
  • MR fluid is a suspension of micrometer-sized magnetizable particles in silicon oil and a functional fluid whose apparent viscosity can be controlled by the applied magnetic field strength. In this paper, a rotary brake using MR fluid called MR brake for tension control of precision machinery such as roll-to-roll printing machinery is presented. First, to obtain the higher performance than conventional powder brake, a MR brake with a modified rotor shape is newly designed and analyzed using FEM. Second, the prototype of MR brake is fabricated with the optimized structural parameters and an experimental apparatus is constructed. Then, basic characteristics of the MR brake are investigated with the different MR fluids. Finally, the validity of the developed MR brake is verified through the comparison with the conventional powder brake.

  • PDF

On magnetostrictive materials and their use in adaptive structures

  • Dapino, Marcelo J.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.303-329
    • /
    • 2004
  • Magnetostrictive materials are routinely employed as actuator and sensor elements in a wide variety of noise and vibration control problems. In infrastructural applications, other technologies such as hydraulic actuation, piezoelectric materials and more recently, magnetorheological fluids, are being favored for actuation and sensing purposes. These technologies have reached a degree of technical maturity and in some cases, cost effectiveness, which justify their broad use in infrastructural applications. Advanced civil structures present new challenges in the areas of condition monitoring and repair, reliability, and high-authority actuation which motivate the need to explore new methods and materials recently developed in the areas of materials science and transducer design. This paper provides an overview of a class of materials that because of the large force, displacement, and energy conversion effciency that it can provide is being considered in a growing number of quasistatic and dynamic applications. Since magnetostriction involves a bidirectional energy exchange between magnetic and elastic states, magnetostrictive materials provide mechanisms both for actuation and sensing. This paper provides an overview of materials, methods and applications with the goal to inspire novel solutions based on magnetostrictive materials for the design and control of advanced infrastructural systems.

Applications of NMR spectroscopy based metabolomics: a review

  • Yoon, Dahye;Lee, Minji;Kim, Siwon;Kim, Suhkmann
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Metabolomics is the study which detects the changes of metabolites level. Metabolomics is a terminal view of the biological system. The end products of the metabolism, metabolites, reflect the responses to external environment. Therefore metabolomics gives the additional information about understanding the metabolic pathways. These metabolites can be used as biomarkers that indicate the disease or external stresses such as exposure to toxicant. Many kinds of biological samples are used in metabolomics, for example, cell, tissue, and bio fluids. NMR spectroscopy is one of the tools of metabolomics. NMR data are analyzed by multivariate statistical analysis and target profiling technique. Recently, NMR-based metabolomics is a growing field in various studies such as disease diagnosis, forensic science, and toxicity assessment.

Surface polishing of Micro channel using Magneto-Rheological fluid (MR유체를 이용한 미세 채널구조물의 표면연마)

  • 이승환;김욱배;민병권;이상조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1873-1876
    • /
    • 2003
  • Magneto-rheological polishing is a new technology used in precision polishing. It utilizes magneto-rheological fluid. nonmagnetic polishing abrasive, aqueous carrier fluids in magnetic field to remove material from a part surface. Silicon micro channel as work piece is fixed in the slurry which is made of MR fluid and CeO$_2$(10 vol%) abrasive particles. And permanent magnet rotate in the slurry to transfers magnetic force to abrasive particles by increasing yield strength of MR fluid. so, the obtained bottom surface roughness of micro channel by experiment reduced to Ra 0.010 $\mu\textrm{m}$ Rmax 0.103 $\mu\textrm{m}$ and finwall surface roughness of micro channel reduced to Ra 0.018 $\mu\textrm{m}$ Rmax 0.468 $\mu\textrm{m}$. At optimum conditions of variables, the workpiece as silicon micro channel have about 24 times smaller surface roughness than before polishing.

  • PDF

A Modeling of a Variable-damping Mount Using MR Fluid (MR 유체를 이용한 가변 감쇠 마운트의 모델화)

  • Ahn, Young-Kong;Tsuchiya, Takashi;Yang, Bo-Suk;Morishita, Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1338-1343
    • /
    • 2000
  • This paper deals with an application of Magneto-Rheological (MR) fluid to a small size mount for precision equipment of automobiles. MR fluid is known as a class of functional fluids with controllable apparent viscosity of fluid by the applied magnetic field strength. A typical MR fluid is a suspension where pure iron particles of $1{\sim}20mm$ in diameter are dispersed in a liquid such as mineral oil or silicone oil, at the concentration of $20{\sim}40$ vol%. Electro magnetic coil is installed at the bottom of a variable-damping mount filled with MR fluid, and its performance was investigated experimentally. Furthermore, the properties of the MR Mount on experimental Study were explained analytically by mechanical model of the MR mount.

  • PDF

A Comparison of Separated and Combined Winding Concepts for Bearingless Centrifugal Pumps

  • Raggl, Klaus;Nussbaumer, Thomas;Kolar, Johann W.
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.243-258
    • /
    • 2009
  • Bearingless centrifugal pump systems are employed in the semiconductor, pharmaceutical and medical industries due to their facility for pumping high purity fluids without particle contamination. Two types of forces have to be generated by the stator units, namely bearing forces for achieving magnetic levitation, and drive forces for producing the needed pump torque. The generation of these forces requires bearing and drive windings, which can be realized as separate bearing and drive coils or as identical, combined coils on the stator claws. In this paper, a detailed comparison between these two winding concepts is undertaken, whereby the copper losses, the power electronics losses, and the achievable pump output pressure are evaluated for both concepts. For each criterion a ratio of improvement is calculated analytically which allows evaluation of the performance of the two winding concepts for any given pump operating point and design. Finally, also practical features such as control complexity, cabling effort and manufacturability are discussed and measurements on prototype systems are carried out to validate the considerations.

Cellmembrane Electrolyte Flow Research Using Electromagnetic Characteristics of Needle and Magnet (침과 자석의 전자기적 특성을 이용한 세포막 전해질 흐름 연구)

  • Lee, Y.J.;Park, M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.3-6
    • /
    • 2002
  • In this paper, the electrolyte flow treatment is suggested using together with needle and magnet. On account of Lorentz force law, we can not only induce the circulation of body fluids at specific hurt but also apply on the treatment of cell membrane voltage control controlling the electrolyte flow. If electric field is added to human body fluid, electrolyte and then magnetic field is taken by magnet, we can induce local region flow through needle, global region flow with artificial electrical field and magnetic field. Electrolyte flow is excellent treatment in clinical treatment.

  • PDF

Comparing the statistics of isothermal compressible turbulence in simulation : Single versus Double forcing

  • Yoo, Hyun-Ju;Cho, Jung-Yeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.108.1-108.1
    • /
    • 2011
  • Turbulence is ubiquitous in astrophysical fluids such as the interstellar medium(ISM) and the intracluster medium(ICM). There are many driving mechanisms which can inject energy into the fluid in variety driving scales, But the plausible driving scale of ISM/ICM turbulence are yet unknown. Therefore, understanding different statistical properties between turbulence with single driving scale and turbulence with double driving scale is required. In this work, we performed 3-dimensional isothermal compressible, magnetohydrodynamic(MHD) turbulence simulations. We drive turbulence in the Fourier space in two ranges, 2

  • PDF