• Title/Summary/Keyword: Magnetic field gradient

Search Result 217, Processing Time 0.023 seconds

Magnetic Field Analysis Due to the Remanent Magnetization Distributed on a Ferromagnetic Thin Plate by using Equivalent Magnetic Models and Material Sensitivity (등가 자기모델과 매질민감도법을 이용한 강자성체 판에 분포하는 영구자화에 기인한 자기장 신호분석)

  • Jeung, Gi-Woo;Kim, Dong-Wook;Kim, Dong-Hun;Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.100-105
    • /
    • 2010
  • For predicting magnetic signals due to the remanent magnetization distributed on a ferromagnetic ship hull, this paper presents an efficient methodology for solving inverse problems, where the material sensitivity analysis based on the continuum mechanics is combined with the equivalent magnetic models. To achieve this, the 3D magnetic charge model and the magnetic dipole moment model are introduced and material sensitivity formulae applicable to each equivalent model are derived. The formulae offer the first-order gradient information of an objective function with respect to the variation of the magnetic charge or magnetic dipole and so an optimal solution can be easily obtained regardless of the number of design variables. To validate the proposed method, the numerical results are comparison with the real measurements of a mock-up model.

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

Vibration and Stability of Composite Cylindrical Shells Subjected to Electromagnetic and Thermal Fields (자기장 및 열하중을 받는 복합재료 원통셸의 진동 및 안정성해석)

  • Park, Sang-Yun;Kang, Sunghwan;Seo, Jung Seok;Song, Ohseop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.9
    • /
    • pp.797-805
    • /
    • 2013
  • In this paper vibration and stability analysis of laminated composite shells based on the first order shear deformation theory(FSDT) for two different boundary conditions(clamped-clamped, simply supported) are performed. Structural model of cross-ply symmetric laminated composite cylindrical shells subjected to a combination of magnetic and thermal fields is developed via Hamilton's variational principle. These coupled equations of motion are based on the electromagnetic equations(Faraday, Ampere, Ohm, and Lorenz equations)and thermal equations which are involved in constitutive equations. Extended Galerkin method is adopted to obtain the discretized equations of motion. Variations of dynamic characteristics of composite shells with applied magnetic field, temperature gradient, laminate thickness-ratio and radius ratio for two boundary conditions are investigated and pertinent conclusions are derived.

Three-Dimensional Analysis of the Coupled Turbulent Flow and Solidification During a Continuous Casting Process with Electromagnetic Brake (전자기 브레이크를 적용한 연속주조공정에서의 난류유동 및 응고의 3차원 해석)

  • Kim, Deok-Soo;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1254-1264
    • /
    • 1999
  • A three-dimensional coupled turbulent fluid flow and solidification process were analyzed in a continuous casting process of a steel slab with Electromagnetic Brake(EMBR). A revised low-Reynolds number $k-{\varepsilon}$ turbulence model was used to consider the turbulent effects. The enthalpy-porosity relation was employed to suppress the velocity within a mushy region. The electromagnetic field was described by Maxwell equations. Tile application of EMBR to the mold region results in the decrease of the transfer of superheat to the narrow face, the increase of temperature in free surface region and most liquid of submold region, and the higher temperature gradient near the solidifying shell. The increasing magnetic flux density effects mainly to the surface temperature of the solidifying shell of narrow face, hardly to the one of wide face. It is seen that in the presence of EMBR a thicker solidifying shell is obtained at the narrow face of the slab.

Application of Magnetic Methods for finding the Egyptian archaeological features

  • Abdallatif Tareq Fahmy;Suh Mancheol;El-All Esmat Abd
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.157-179
    • /
    • 2004
  • The application of magnetic method for archaeoprospection has been carried out through two archaeological areas in Egypt, Abydos and Abu Sir, In order to find out tile ancient Egyptian archaeological features. The magnetic work at the selected archaeological site of Abydos area was carried out by gradiometer survey, while magnetic work at the selected archaeological site of Abu Sir area was carried out by gradiometer survey and magnetic susceptibility measurements. A gradiometer survey with raster of 0.5 m/0.5 m has been carried out on a surface area of $9600 m^2$ at Abydos area to relocate the buried Solar Boats. The magnetic data were processed using Geoplot software to treat the field noises and enhance the quality of the obtained images. The final magnetic images indicate the existence of 12 Solar Boats as well as tombs, remains of ancient rooms and walls. All of them are expected to belong to the Middle Kingdom, particularly from the 18th to 20th Dynasties. Two magnetic tools have been applied over a selected site of $25600 m^2$ at Abu Sir area in order to detect the hidden archaeological features nearby the Sun Temple. The acquisition of the magnetic data was initiated by the measurements of the topsoil magnetic susceptibility of 272 samples collected from the whole studied area, and then followed by the gradiometer survey to measure tile vertical gradient of the geomagnetic field over an area of $14400 m^2$. The magnetic susceptibility results show the presence of high concentration at the middle part of the study area with a little extension to the south western side, with maximum value of about $36{\times}10^5$ SI. They may indicate the proximity of ritual monuments. Also, they offered the site of interest for carrying out a gradiometer survey. The gradiometer results show tile existence of numerous distributed archaeological features made of mud-bricks with different shapes and sizes. They may indicate tombs, burial rooms, dissected walls; all of them are expected to belong to the 5th Dynasty of pharaohs, who used to build their buildings by mud bricks. The depth of the expected buried archaeological features has been estimated from tihe gradiometer. It is around 1.2m for deep features and 0.42 m for shallow features.

  • PDF

Reduction of magnetic anomaly observations from helicopter surveys at varying elevations (고도가 변화하는 헬리콥터 탐사에서 얻어지는 자력이상의 변환)

  • Nakatsuka, Tadashi;Okuma, Shigeo
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.121-128
    • /
    • 2006
  • Magnetic survey flights by helicopters are usually parallel to the topographic surface, with a nominal clearance, but especially in high-resolution surveys the altitudes at which observations are made may be too variable to be regarded as a smooth surface. We have developed a reduction procedure for such data using the method of equivalent sources, where surrounding sources are included to control edge effects, and data from points distributed randomly in three dimensions are directly modelled. Although the problem is generally underdetermined, the method of conjugate gradients can be used to find a minimum-norm solution. There is freedom to select the harmonic function that relates the magnetic anomaly with the source. When the upward continuation function operator is selected, the equivalent source is the magnetic anomaly itself. If we select as source a distribution of magnetic dipoles in the direction of the ambient magnetic field, we can easily derive reduction-to-pole anomalies by rotating the direction of the magnetic dipoles to vertical.

Eringen's nonlocal elasticity theory for wave propagation analysis of magneto-electro-elastic nanotubes

  • Ebrahimi, Farzad;Dehghan, M.;Seyfi, Ali
    • Advances in nano research
    • /
    • v.7 no.1
    • /
    • pp.1-11
    • /
    • 2019
  • In this article, wave propagation characteristics in magneto-electro-elastic (MEE) nanotube considering shell model is studied in the framework nonlocal theory. To account for the small-scale effects, the Eringen's nonlocal elasticity theory of is applied. Nonlocal governing equations of MEE nanotube have been derived utilizing Hamilton's principle. The results of this investigation have been accredited by comparing them of previous studies. An analytical solution of governing equations is used to obtain phase velocities and wave frequencies. The influences of different parameters, such as different mode, nonlocal parameter, length parameter, geometry, magnetic field and electric field on wave propagation responses of MEE nanotube are expressed in detail.

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

Effect of Manganese Content on the Magnetic Susceptibility of Ferrous-Manganese Alloys: Correlation between Microstructure on X-Ray Diffraction and Size of the Low-Intensity Area on MRI

  • Youn, Sung Won;Kim, Moon Jung;Yi, Seounghoon;Ahn, Hyun Jin;Park, Kwan Kyu;Lee, Jongmin;Lee, Young-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.76-87
    • /
    • 2015
  • Purpose: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). Materials and Methods: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and $T2^*$weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. Results: Three phases of ${\alpha}^{\prime}$-martensite, ${\gamma}$-austenite, and ${\varepsilon}$-martensite were seen on XRD, and their composition changed from ${\alpha}^{\prime}$-martensite to ${\gamma}$-austenite and/or ${\varepsilon}$-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised ${\alpha}^{\prime}$-martensite, the Fe-20Mn and Fe-25Mn specimens comprised ${\gamma}+{\varepsilon}$ phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single ${\gamma}$ phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. Conclusion: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of ${\gamma}$-austenite and/or ${\varepsilon}$-martensite.

The Effect of Magnetic Field on Enhancing the Anisotropy of Melt-spun Nd-Fe-Co(-Zr)-B Alloy (급속응고중 외부자장에 의한 Nd-Fe-Co(-Zr)-B계 합금의 자기이방성 향상)

  • Lee, U-Yeong;Choe, Seung-Deok;Yang, Chung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.233-238
    • /
    • 1992
  • Melt-spun $Nd_{14}Fe_{76}Co_4B_6$ and $Nd_{10.5}Fe_{79}Co_2Zr_{1.5}B_7$ ribbons were prepared under an externally applied magnetic field. Magnetic properties in terms of anisotropy were evaluated by discussing the effect of textured structure of the ribbon samples as well as its powders. About 32 % increase in $(B{\cdot}H)_{max}$ and 18.8 % increase in $B_r$ were observed along the perpendicular direction of the ribbon plane which is more prominent for the Nd-Fe-Co-Zr-B than for the Nd-Fe-Co-B alloy. The enhancement of magnetic anisotropy was monitored by measuring the anisotropy constant of each alloy as a function of quenching rate of the ribbon. It was found that for the melt-spun ribbon quenched at slow rate(less than 7 m/s) the magnetic field effect was overwhelmed by the heat gradient effect through the ribbon thickness while the field effect was prominent at intermediate quenching rate (more than 7~11 m/s). The reproducible maximum energy product, $(B{\cdot}H)_{max}$=16.4 MGOe can be obtained from the Nd-Fe-Co-Zr-B alloy.

  • PDF