Study on Elimination of EMI in ELF-Band for EPS-Based Smart TV Control (전위계차센서 기반 스마트TV 제어를 위한 극저주파 전자기간섭 제거 연구)

  • Jang, Jin-Soo;Kim, Young-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.3
    • /
    • pp.401-407
    • /
    • 2015
  • In this paper, we propose the method to eliminate EMI (Electro-Magnetic Interference) in ELF (Extremely Low Frequency) band below 2 KHz for extending the gesture-recognition distance of smart TVs to more than 3m using electric potential sensor. First, we measure the electric field generated from the back panel of a TV and propose the effective arrangement of two sets of differential sensors as well as the shielding method using metal fiber. Also, we eliminate the PLN (Power Line Noise) and other noise generated from the TV and sensors as well as surrounding environments using filters. Using the proposed EMI eliminating methods, we evaluate displacement ratio on measured signals according to distance between sensors and a moving hand. Experiment results show that our proposed method can extend the hand-gesture sensing distance using EPS (Electric Potential Sensor) up to more than 3m, which is enough to satisfy applicability of EPS based remote control to Smart TVs.

Design of 2-DoF Scanning Mirror using Electromagnetic force (전자기력을 이용한 2 자유도 스캐닝 미러 설계)

  • Shin, Bu Hyun;Kim, Young-Jin;Oh, Dongho;Lee, Jeong-Woo;Choi, Hyun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.177-178
    • /
    • 2014
  • This work proposes a two-dimensional (2-D) laser scanning mirror actuator with a simple structure composed of one magnet and four coils. The mirror-actuating device generates 2-D scanning motions about two orthogonal axes by combining electromagnetic actuators of the conventional moving-magnet types. The magnet is attached to back side of the mirror placed inside of the moving frame. The four coils is placed on the base frame in a cross shape. We implement a finite element analysis to calculate magnetic flux in the electromagnetic system with the overall size of $20mm(W){\times}20mm(D){\times}13mm(H)$ for the mirror size of $8mm{\times}8mm$. The each moving-magnet type electromagnetic actuator has the motor constant 3.41 mNm/A and the restoring constant 1.75 mNm/rad and the resonance frequency of 58 Hz and the bandwidth of 80 Hz. The proposed compact and simple 2-D scanning mirror predicted advantages of large 2-D angular deflections, wide frequency bandwidth and low manufacturing cost.

  • PDF

A Study on the Ultrasonic Application for the Efficiency Elevation of the Hydrogen Fuel Production (On solution and concentration) (수소연료 생산의 효율향상을 위한 초음파응용에 관한 연구(용액과 농도 중심으로))

  • Song, Min-Geun;Lee, Sang-Bum;Son, Seung-Woo;Ju, Eun-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2001
  • An investigation on the A/V(ampere/volt) gradient according to the concentration and the kind of solution in a electrolyzer is carried out to obtain the basic data on the ultrasonic application for the efficiency elevation of the hydrogen fuel production. KOH is selected as an electrolyte and concentrations are 0%, 10%, 20% and 30%. The solutions are city water, city water with nitrogen. distilled water and distilled water with nitrogen. The Electrochemical analyzer(BAS Co.) is used as a measuring device to observe the A/V gradient. And the limit of volt is from -3000mV to +3000mV. The 28kHz magnetic transducer is selected to give them ultrasonic forcing. In results, it is clarified that ultrasonic influences the A/V gradient in the electrolytic solution.

  • PDF

Effects of Rapid Thermal Annealing on Thermal Stability of FeMn Spin Valve Sensors

  • Park, Seung-Young;Choi, Yeon-Bong;Jo, Soon-Chul
    • Journal of Magnetics
    • /
    • v.10 no.2
    • /
    • pp.52-57
    • /
    • 2005
  • In this research, magnetoresistance (MR) ratio (MR), resistivity, and exchange coupling field $(H_{ex})$ behaviors for sputter deposited spin valves with FeMn antiferromagnetic layer have been extensively investigated by rapid thermal annealing (RTA) as well as conventional annealing (CA) method. 10 s of RTA revealed that interdiffusion was not significant up to $325^{\circ}C$ at the interfaces between the layers when the RTA time was short. The MR of FeMn spin valves were reduced when the spin valves were exposed to temperature of $250^{\circ}C$, even for a short time period of 10 s prior to CA. $H_{ex}$ was maintained up to $325^{\circ}C$ of CA when the specimen was subjected to 10 s of RTA at $200^{\circ}C$ prior to CA, which is $25^{\circ}C$ higher than the result obtained from the CA without prior RTA. Therefore, the stability of $H_{ex}$ could be enhanced by a prior RTA before performing CA up to annealing temperature of $325^{\circ}C$. MR and sensitivity of the specimens annealed without magnetic field up to $275^{\circ}C$ were recovered to the values prior to CA, but $H_{ex}$ was not recovered. This means that reduced MR sensitivity and MR during the device fabrication can be recovered by a field RTA.

Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect Device

  • Lee, Sang-Suk;Choi, Jong-Gu;Son, Il-Ho;Kim, Keun-Ho;Nam, Dong-Hyun;Hong, You-Sik;Lee, Woo-Beom;Hwang, Do-Guwn;Rhee, Jang-Roh
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.449-452
    • /
    • 2011
  • A wrist wearable cuffless pulsimeter with a portable and small size apparatus using Hall effect is fabricated. The analysis of the pulse wave measured by the testing product of pulsimeter is done to measure the pulse rate and blood pressure. The blood pressure obtained by the puslimeter is compared with the practical values measured by electronic or mercury liquid blood pressure meters. The detail analysis of a pulse wave measured by a wrist wearable cuffless pulsimeter detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus.

IMAGING IN RADIATION THERAPY

  • Kim Si-Yong;Suh Tae-Suk
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.327-342
    • /
    • 2006
  • Radiation therapy is an important part of cancer treatment in which cancer patients are treated using high-energy radiation such as x-rays, gamma rays, electrons, protons, and neutrons. Currently, about half of all cancer patients receive radiation treatment during their whole cancer care process. The goal of radiation therapy is to deliver the necessary radiation dose to cancer cells while minimizing dose to surrounding normal tissues. Success of radiation therapy highly relies on how accurately 1) identifies the target and 2) aim radiation beam to the target. Both tasks are strongly dependent of imaging technology and many imaging modalities have been applied for radiation therapy such as CT (Computed Tomography), MRI (Magnetic Resonant Image), and PET (Positron Emission Tomogaphy). Recently, many researchers have given significant amount of effort to develop and improve imaging techniques for radiation therapy to enhance the overall quality of patient care. For example, advances in medical imaging technology have initiated the development of the state of the art radiation therapy techniques such as intensity modulated radiation therapy (IMRT), gated radiation therapy, tomotherapy, and image guided radiation therapy (IGRT). Capability of determining the local tumor volume and location of the tumor has been significantly improved by applying single or multi-modality imaging fur static or dynamic target. The use of multi-modality imaging provides a more reliable tumor volume, eventually leading to a better definitive local control. Image registration technique is essential to fuse two different image modalities and has been In significant improvement. Imaging equipments and their common applications that are in active use and/or under development in radiation therapy are reviewed.

Improvement of Submarine Cooling System using HILS Simulation (HILS 기반의 수중체 냉각 시스템 개선)

  • Jung, Sung-Young;Oh, Jin-Seok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.5
    • /
    • pp.376-383
    • /
    • 2012
  • Owing to rapid development of power device and inverters, most of submarines adopt an eletric propulsion system. Although PMPM(Permanent Magnet Propulsion Motor) propulsion system has relatively higher power, energy conversion efficiency and smaller volume than engine propulsion system, it also produces large amount of heat due to current flowing inside motor coils and change of magnetic field induced by iron core. The produced heat in stator and inverter largely affects motor efficiency and bearing lubrication and causes thermal aging while the system is on operation. So, we analyze the existing cooling system and submarine ESS (Energy Saving System) cooling system whose power consumption is reduced. HILS(Hardware In the Loop System) technique is used for the modelling of the submarine cooling system. To confirm the ESS cooling system characteristic, HILS is simulated using LabVIEW with hardware. As a result, the ESS cooling system has the characteristic of better temperature stability and less power consumption than the existing one.

Near-field Characterization on Light Emanated from Subwavelength Plasmonic Double Slit of Finite Length

  • Kim, Ki-Young;Goncharenko, Anatoliy V.;Hong, Jian-Shiung;Chen, Kuan-Ren
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.196-201
    • /
    • 2011
  • Near-field properties of light emanated from a subwavelength double slit of finite length in a thin metal film, which is essential for understanding fundamental physical mechanisms for near-field optical beam manipulations and various potential nanophotonic device applications, is investigated by using a three-dimensional finite-difference time-domain method. Near-field intensity distribution along the propagation direction of light after passing through the slit has been obtained from the phase relation of transverse electric and magnetic fields and the wave impedance. It is found that the near field of emerged light from the both slits is evanescent, that is consistent with conventional surface plasmon localization near the metal surface. Due to the finite of the slit, the amplitude of this evanescent field does not monotonically approach to than of the infinite slit as the slit length increases, i.e. the near-field of the longer slit along the center line can be weaker than that of the shorter one.

Planar Hall Effect of GaMnAs Grown via low Temperature Molecular Beam Epitaxy (저온 분자선에피탁시 방법으로 성장시킨 GaMnAs의 planar Hall 효과)

  • Kim, Gyeong-Hyeon;Park, Jong-Hun;Kim, Byeong-Du;Kim, Do-Jin;Kim, Hyo-Jin;Im, Yeong-Eon;Kim, Chang-Su
    • Korean Journal of Materials Research
    • /
    • v.12 no.3
    • /
    • pp.195-199
    • /
    • 2002
  • Planar Hall effect of ferromagnetic GaMnAs thin films was investigated for the first time. The films were grown in an optimized growth condition via molecular beam epitaxy at low temperatures. For the optimization of the growth conditions, we used reflection high-energy electron diffraction, electrical conductivity, double crystal x-ray diffraction, and superconducting quantum interference device measurements techniques. We observed that the difference between the longitudinal resistance and the transverse resistance matches the planar Hall resistance. The ratio of the planar Hall resistance at saturation magnetic field to that at zero reached above 500%.

Design of an Absolute Location and Position Measuring System for a Mobile Robot

  • Kim, Dong-Hwan;Park, Young-Chil;Hakyoung Chung
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.10
    • /
    • pp.1369-1379
    • /
    • 2001
  • This paper focuses on a development of a sensor system measuring locations of a vehicle to localize a mobile robot while it tracks on the track (location sensor) . Also it focuses on a system configuration identifying the vehicle's orientation and distance from the object while it is stationary at certain station (position sensor) . As for the location sensor it consists of a set of sensors with a combined guiding and counting sensor, and an address-coded sensor to localize the vehicle while moving on the rail. For the position sensor a PSD (Position Sensitive Device) sensor with photo-switches sensor to measure the offset and orientation of the vehicle at each station is introduced. Both sensor systems are integrated with a microprocessor as a data relay to the main computer controlling the vehicle. The location sensor system is developed and its performance for a mobile robot is verified by experiments. The position measuring system is proposed and is robust to the environmental variation. Moreover, the two kinds of sensor systems guarantee a low cost application and high reliability.

  • PDF