• 제목/요약/키워드: Magnetic device

검색결과 932건 처리시간 0.025초

Fe-Si 전기강판 폐스크랩을 이용한 연자성 분말 및 테이프 제조기술 (Manufacturing Technology for Tape Casting and Soft Magnetic Powder Using by Recycling Scrap of Fe-Si Electrical Sheet)

  • 홍원식;김상현;박지연;오철민;이우성;김승겸;한상조;심금택;김휘준
    • 마이크로전자및패키징학회지
    • /
    • 제23권2호
    • /
    • pp.11-18
    • /
    • 2016
  • This study focused on examining the possibility for recycling of Fe-Si electric sheet. We manufactured Fe-6.5Si mother alloy using by Fe-Si electric sheet scrap for transformer core materials. And then, soft magnetic alloy powder which diameter and shape were $45{\sim}150{\mu}m$ and sphere type was prepared by gas atomization process. As we compared to commercial Fe-6.5Si powder, its diameter distribution and microstructure of recycled powder was a similar. To investigate the possibility of reusing the soft magnetic composite sheet for electronics, recycled powder was treated to have a high aspect ratio (AR), and we finally obtained the 65~66 AR and $2.3{\mu}m$ thickness powder. To release the residual stress of powder, heat treatment was conducted under $300{\sim}400^{\circ}C$, $N_2$ gas. And then, soft magnetic sheet was made by tape casting process using by those powders. After the density and permeability of tape was measured, and we confirmed that the recycled Fe-Si electric sheet scrap was possible to reuse the soft magnetic materials of electronics.

Fe-Si 전기강판 폐스크랩을 이용한 3원계 Fe-9.8Si-6.0Al 합금의 연자성 특성 (Soft Magnetic Property of Ternary Fe-9.8Si-6.0Al Alloy Using by Recycling Fe-Si Electrical Steel Sheet Scrap)

  • 홍원식;양형우;박지연;오철민;이우성;김승겸;한상조;심금택;김휘준
    • 마이크로전자및패키징학회지
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 2017
  • Fe-9.8Si-6.0Al mother alloy was manufactured using by Fe-3.5Si recycled scrap and Si powder. And then, soft magnetic alloy powder of $D_{50}$ size and sphere type were prepared by gas atomization process. To obtain the soft magnetic powder of a high aspect ratio, in the first, we conducted the ball milling process for 8 hours. And heat treatment was performed under $650^{\circ}C$, 2 hours and $N_2$ atmosphere condition for reducing the residual stress of the powder. Based on these process, we made around $50{\mu}m$ diameter Fe-9.8Si-6.0Al powder, which morphology and shape was a similar to the commercial Fe-Si-Al powder. Finally, the soft magnetic sheets were prepared by tape casting process using by those powders. The permeability of the tape casting sheet was measured, and we confirmed the possibility of reusing to the soft magnetic materials of Fe-Si electric sheet scrap.

최적화 기법을 사용한 초소형 카메라 조리개 셔터장치의 성능향상 (The Improvement of Performance in an Ultra small Camera Iris-Shutter Device using Topology Optimization)

  • 박순옥;유정훈
    • 정보저장시스템학회논문집
    • /
    • 제5권2호
    • /
    • pp.53-57
    • /
    • 2009
  • This study is concerned with the design of a camera iris-shutter device for producing force. The camera iris-shutter with yoke should have a smaller size and a bigger magnetic force than the previous model. Since the induced magnetic force operates shutter movement, the magnetic force maximization for a given input current is an important issue. To achieve the goal, new system is designed by the topology optimization method. The design is refined through the design of experiments to find the detail camera iris shutter design satisfying design constraints.

  • PDF

회전식 자기냉동장치에 대한 실험적 연구 (Experimental Study on a Rotary Magnetic Refrigeration Device)

  • 이종석;홍정호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1101-1106
    • /
    • 2004
  • Magnetic refrigeration is based on the magnetocaloric effect (MCE)-the ability of some materials to heat up when magnetized and cool down when demagnetized. A rotary magnetic refrigeration device using gadolinium (Gd) ribbon and permanent magnets was constructed for experimental study. Gd ribbon attached around a rotating wheel is cyclically magnetized and demagnetized by permanent magnets and exchanges heat with liquid in the surrounding container. Temperature of the liquid in each divided section of the container was measured and the experimental results obtained in this study were discussed.

자기저항소자를 이용한 전자 컴파스 개발에 관한 연구 (A Study on the Development of Electro Magnetic Compass Using Magnetic Resistance Element)

  • 양주호;김창화;박태원;문덕홍;이일영
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.60-66
    • /
    • 1999
  • Most of the small-type fishing boats in this country don't have the autopilot system such as the large ships have. In this papers, we describes on the development of electro magnetic compass for the autopilot system of the small-type fishing boat, which is utilized the MR(magnetic resistance) device and the inclination sensor. And we investigated the validity of the developed electro magnetic compass through results of actual experiment.

  • PDF

Characteristics of a Tunable Microstrip Bandpass Filter Under the Influence of Magnetic Field

  • Chow, Hwang-Cherng;Chatterjee, P.;Lin, Kuei-Hung;Feng, Wu-Shiung
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.275-280
    • /
    • 2017
  • A magnetic-field tunable 2.4 GHz microwave bandpass filter having insertion loss < -5dB on an FR4 substrate with the flaky magnetic material was designed and characterized. The tunability in the designed bandpass filter was achieved by adhering soft magnetic materials on top of the device. This soft magnetic material can be composed of ferromagnetic substance or ferrimagnetic substance. The performance of the designed bandpass filter under its influence is investigated. The frequency offset ratio changes over 30 %. There is over 20 % change in the center frequency towards the lower frequency region due to this application. These magnetic material layers achieved the center frequency shift and bandwidth extension without actually changing the original structure of the device.

Angle Sensors Based on Oblique Giant Magneto Impedance Devices

  • Kim, Do-Hun;Na, Ji-Won;Jeung, Won-Young
    • Journal of Magnetics
    • /
    • 제14권1호
    • /
    • pp.42-46
    • /
    • 2009
  • The measurement of external magnetic field orientation using Giant Magneto Impedance (GMI) sensors has been performed. A soft magnetic alloy of $Co_{30}Fe_{34}Ni_{36}$ was electroplated on a Si wafer with a CoFeNi seed layer. V-shaped microwire patterns were formed using a conventional photolithography process. An external magnetic field was generated by a rectangular AlNiCo permanent magnet. The reference direction was defined as the external magnetic field direction oriented in the middle of 2 GMI devices. As the orientation of the magnetic field deviated from the reference direction, variation in the field component along each device introduced voltage changes. It was found that, by taking the voltage difference between the left and right arms of the Vshaped device, the nonlinearity of each device could be significantly reduced. The fabricated angle sensor had a linear range of approximately $70^{\circ}$ and an overall sensitivity of approximately 10 mV.

MR 유체를 이용한 촉감구현장치의 설계 및 성능 평가 (Design and Performance Evaluation of Tactile Device Using MR Fluid)

  • 김진규;오종석;이상록;한영민;최승복
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1220-1226
    • /
    • 2012
  • This paper proposes a novel type of tactile device utilizing magnetorheological(MR) fluid which can be applicable for haptic master of minimally invasive surgery(MIS) robotic system. The salient feature of the controllability of rheological properties by the intensity of the magnetic field(or current) makes this potential candidate of the tactile device. As a first step, an appropriate size of the tactile device is designed and manufactured via magnetic analysis. Secondly, in order to determine proper input magnetic field the repulsive forces of the real body parts such as hand and neck are measured. Subsequently, the repulsive forces of the tactile device are measured by dividing 5 areas. The final step of this work is to obtain desired force in real implementation. Thus, in order to demonstrate this goal a neuro-fuzzy logic is applied to get the desired repulsive force and the error between the desired and actual force is evaluated.

MR 유체를 이용한 촉감구현장치의 설계 및 성능 평가 (Design and Performance Evaluation of Tactile Device Using MR Fluid)

  • 김진규;오종석;한영민;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.415-420
    • /
    • 2012
  • This paper proposes a novel type of tactile device utilizing magnetorheological (MR) fluid which can be applicable for haptic master of minimally invasive surgery (MIS) robotic system. The salient feature of the controllability of rheological properties by the intensity of the magnetic field (or current) makes this potential candidate of the tactile device. As a first step, an appropriate size of the tactile device is designed and manufactured via magnetic analysis. Secondly, in order to determine proper input magnetic field the repulsive forces of the real body parts such as hand and neck are measured. Subsequently, the repulsive forces of the tactile device are measured by dividing 5 areas. The final step of this work is to obtain desired force in real implementation. Thus, in order to demonstrate this goal a neuro-fuzzy logic is applied to get the desired repulsive force and the error between the desired and actual force is evaluated.

  • PDF

소형 금속방사성폐기물 제염장치 개발 : 자기장 연삭핀과 초음파 세정기의 응용 (Smart Decontamination Device for Small-size Radioactive Scrap Metal Waste : Using Abrasion pin in Rotating Magnetic Field and Ultrasonic Wave Cleaner)

  • 홍용호;박수리;한상욱;김병직
    • 방사성폐기물학회지
    • /
    • 제12권1호
    • /
    • pp.79-88
    • /
    • 2014
  • 원자력이용시설에서 발생한 작은 크기의 금속 조각들을 효과적으로 제염하는 스마트 장치를 개발하였다. 이 장치는 자성연마재를 포함한 영역의 자속밀도를 연속적으로 변화시키는 방법과 초음파를 이용하는 다중 제염장치이다. 한편, 제염 효율을 높이기 위해 제염 장치가 제염 대상 전체에 작용하도록 장치들의 구성을 수정하였다. 개발된 장치들의 최적 작동조건을 도출하여 샘플로 선정한 소형의 금속방사성페기물에 대하여 자기장과 초음파제염을 각각 15분간 실시하였다. 그 결과 제염계수의 범위는18~56으로 크게 향상되었으며 제염 후 모든 샘플은 백그라운드(BKG)값 이하로 확인되었다.