• Title/Summary/Keyword: Magnetic capture

Search Result 65, Processing Time 0.022 seconds

Study on the production of the ceramic by the mineral-Oriental medicine and the property of the clean active water depositting on the ceramic stone (광물성 한약재 세라믹 조성 및 세라믹 침적 청정활성수 특성에 대한 연구)

  • Kim Gyeong Cheol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.4
    • /
    • pp.1159-1162
    • /
    • 2004
  • We studied on the production of the ceramic by the mineral-Oriental medicine and the property of the clean active water depositting on the ceramic stone. The results are as follows: We properly mixed of maifanshi, mica, ochre, and added to a small amount cinnabar, and therefore formed the ceramic stone. By the plasticity process and the irradiating magnetic force recovered the disappeared a part of constitutent elements. The recovered effects were become higher the freshness, maintenance, deodoriztion, clean water. As well as having the ability on capture of the notoxious heavy metal on human. The ceramic powder were mixed proper dose maifanshi, mica. And the powder had ionization, absorption, adhesion by the plasticity process and magnetic force. The clean active water of depositting on the ceramic stone during 24hours were observed significant the content of micro element, dissolved oxygen, abstraction on Herbs.

An MHD Simulation of the X2.2 Solar Flare on 2011 February 15

  • Inoue, Satoshi;Choe, Gwangson
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.69.1-69.1
    • /
    • 2014
  • We perform an MHD simulation combined with observed vector field data to clarify an eruptive dynamics in the solar flare. We first extrapolate a 3D coronal magnetic field under a Nonlinear Force-Free Field (NLFFF) approximation based on the vector field, and then we perform an MHD simulation where the NLFFF prior to the flare is set as an initial condition. Vector field was obtained by the Soar Dynamics Observatory (SDO) at 00:00 UT on February 15, which is about 90 minutes before the X2.2-class flare. As a result, the MHD simulation successfully shows an eruption of strongly twisted lines whose values are over one-turn twist, which are produced through the tether-cut magnetic reconnection in strongly twisted lines of the NLFFF. Eventually, we found that they exceed a critical height at which the flux tube becomes unstable to the torus instability determining the condition that whether a flux tube might escape from the overlying field lines or not. In addition to these, we found that the distribution of the observed two-ribbon flares is similar to the spatial variance of the footpoints caused by the reconnection of the twisted lines being resided above the polarity inversion line. Furthermore, because the post flare loops obtained from MHD simulation well capture that in EUV image taken by SDO, these results support the reliability of our simulation.

  • PDF

A Solar Cyclone with Chromospheric Running Wave

  • Magara, Tetsuya;An, Jun-Mo;Lee, Hwanhee;Kang, Jihye;Inoue, Satoshi;Choe, Gwang-Son
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.113.2-113.2
    • /
    • 2012
  • An innovative solar observing satellite, Hinode, has successfully observed the detailed evolution of a rapidly developing emerging flux region from the beginning of its appearance at the solar surface. The high spatial and temporal resolution provided by the satellite enables to capture the prominent dynamic processes such as the rotational motion of a polarity region with intense magnetic flux which is reminiscent of a cyclone on the Earth, and a running wave that spreads ahead of this rotating polarity region. This 'solar cyclone' is, on the other hand, generated differently from terrestrial cyclones, and a possible generating mechanism for it is demonstrated with a three-dimensional magnetohydrodynamic simulation of a twisted magnetic flux tube emerging from the solar interior into the solar atmosphere. The simulation shows that the rotational motion is caused by a strong downflow of plasma along the twisted field lines that form a helical pillar standing upright on the Sun.

  • PDF

Using Bayesian Approaches to Reduce Truncation Artifact in Magnetic Resonance Imaging

  • Lee, Su-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.585-593
    • /
    • 1998
  • In Fourier magnetic resonance imaging (MRI), the number of phase encoded signals is often reduced to minimize the duration of the studies and maintain adequate signal-to-noise ratio. However, this results in the well-known truncation artifact, whose effect manifests itself as blurring and ringing in the image domain. In this paper, we propose a new regularization method in the context of a Bayesian framework to reduce truncation artifact. Since the truncation artifact appears in t도 phase direction only, the use of conventional piecewise-smoothness constraints with symmetric neighbors may result in the loss of small details and soft edge structures in the read direction. Here, we propose more elaborate forms of constraints than the conventional piecewise-smoothness constraints, which can capture actual spatial information about the MR images. Our experimental results indicate that the proposed method not only reduces the truncation artifact, but also improves tissue regularity and boundary definition without oversmoothing soft edge regions.

  • PDF

Gait Estimation System for Leg Diagnosis and Rehabilitation using Gyroscopes (하지 진단 및 재활을 위한 각속도계 기반 측정시스템)

  • Lee, Min-Young;Lee, Soo-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.866-871
    • /
    • 2010
  • Gait analysis is essential for leg diagnosis and rehabilitation for the patients, the handicapped and the elderly. The use of 3D motion capture device for gait analysis is very common for gait analysis. However, this device has several shortcomings including limited workspace, visibility and high price. Instead, we developed gait estimation system using gyroscopes. This system provides gait information including the number of gaits, stride and walking distance. With four gyroscope (one for each leg's thigh and calf) outputs, the proposed gait modeling estimates the movements of the hip, the knees and the feet. Complete pedestrian localization is implemented with gait information and the heading angle estimated from the rate gyro and the magnetic compass measurements. The developed system is very useful for diagnosis and the rehabilitation of the pedestrian at the hospital. It is also useful for indoor localization of the pedestrians.

Continuous Combined Process for Homogeneous Dispersion of Ceramic Particle and Aluminum Materials (세라믹 입자/알루미늄 소재의 연속복합 균일분산)

  • 이동건;이승후;강충길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.381-384
    • /
    • 2001
  • The combined stirring method to uniform distribution of particle is consisted of two strring force both electro-magnetic stirring generated from induction heating and mechanical stirring with graphite stirrer. PMMC billets were fabricated with the volume fractions ranged from 0% to 20% and particle sizes ranged from 14$\mu\textrm{m}$ to 25$\mu\textrm{m}$. It is important to control the size of primary ${\alpha}$-AI solid particles because it could become the cause of the particle pushing or capture phenomena from the fact that secondary dendrite arm spacing size depends on the cooling rate during the solidification in hypoeutectic AI-Si alloy.

  • PDF

Fabrication of Bulk High-Tc Superconductor (벌크형 고온 초전도 합성)

  • Lee, Sang Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.333-336
    • /
    • 2021
  • Oxide YBCO bulk superconductors are manufactured using the melt process. Because seed crystal growth method utilizes a slow-spreading layer-by-layer reaction, a long-term heat treatment is required to manufacture a single-crystal specimen of several cm. In this study, the melt process method was applied to compensate for the shortcomings of the seed crystal growth method. The thickness of the upper and lower pellets of the YBCO bulk was molded to 40 mm, and YBCO superconductor was produced by heat treatment. The measurement results of capture magnetism was in line with the literature. This results in a relationship that the higher the growth of Y211 particle in the YBCO, the higher the superconducting properties. We analyzed the YBCO superconductor, focusing on the Y2BaCuO5 particle distribution.

Analysis of mechanical properties of microtubules under combined effects of surface and body forces for free and embedded microtubules in viscoelastic medium

  • Farid, Khurram;Taj, Muhammad
    • Advances in concrete construction
    • /
    • v.13 no.3
    • /
    • pp.255-264
    • /
    • 2022
  • Vibration is expected to occur in microtubules as tubular heterodimers. They oscillate like electric dipoles. Several research studies have estimated a frequency of vibration using the orthotropic model, a beam or rod like models and shell models, considering the surface forces. The effects of body forces on the dynamics of the microtubules were not yet taken into account. This study seeks to capture the body force effects on the vibration modes generated and on the corresponding frequency for microtubules. An orthotropic elastic shell model for the structural details of microtubules is used for the analysis. The tests are conducted out for microtubules, exposed to electro-magnetic and gravitational forces, the transverse vibration, radial mode vibration, and axial mode of vibration have accomplished. We therefore, evaluate and compare microtubules' frequencies with prior results of vibration frequency without the effects of body force.

Interactions in transversely isotropic new modified couple stress solid due to Hall current, rotation, inclined load with energy dissipation

  • Parveen Lata;Harpreet Kaur
    • Coupled systems mechanics
    • /
    • v.13 no.1
    • /
    • pp.21-41
    • /
    • 2024
  • This paper is concerned with the disturbances in a transversely isotropic new modified couple stress homogeneous thermoelastic rotating medium under the combined influence of Hall currents, magnetic fields, and mechanical sources represented by inclined loads. The application of Laplace and Fourier transform techniques are used for the derivation of analytical expressions for various physical quantities. As an application,the bounding surface is subjected to uniformly and linearly distributed force (mechanical force). Present model contains length scale parameters that can capture the size effects. Numerical inversion techniques has been used to provide insights into the system's behavior in the physical domain. The graphical representation of numerical simulated results has been presented to emphasize the impact of rotation and inclined line loads on the system, enhancing our understanding of the studied phenomena. Further research can extend this study to investigate additional complexities and real-world applications.

The study on Low-cost Position Sensor by a Single Opto-coupler for BLDC Drive (BLDC 구동을 위한 단일 옵토 카플러에 의한 저가형 위치센서에 관한 연구)

  • Kwon, Soon-Jae;Kim, Young-Su
    • Journal of Power System Engineering
    • /
    • v.20 no.3
    • /
    • pp.22-28
    • /
    • 2016
  • Energy consumption rapidly increases with industrial development. therefore an interest in the efficiency of various power converters is increasing. Especially, the field of high-efficiency small motors widely distributed for industrial and family use is considered a very important field in terms of efficient energy usage, and accordingly, in the field of small electric equipment, the use of BLDC that allows high-efficiency drive in an inductor gradually increases. However, for the BLDC drive, information on the position of the rotor is essential. Both methods using a magnetic encoder and an optical encoder to detect the information on the position of the rotor obtain the information by three position sensitive devices, and if any one of these position sensitive devices fails to function, no positional information can be obtained, so there is a limitation in implementing a position sensor with high reliability. In the paper, proposes a new type of encoder that can obtain the positional information on the position of the rotor using a single position sensor in order to overcome the issues that it has to use numerous signal flows and that the reliability is reduced for the acquisition of positional information generated by using multiple position detectors. The encoder in the proposed method replaced the function of generating positional information from multiple sensors with the shape of the encoder plate and the capture function of MICOM. In order to verify the validity of the position detection technique by the proposed encoder, a prototype was produced, and an experiment using the capture function of DSP was conducted through this.