• 제목/요약/키워드: Magnetic capture

검색결과 65건 처리시간 0.026초

Bioconjugation of Poly(poly(ethylene glycol) methacrylate)-Coated Iron Oxide Magnetic Nanoparticles for Magnetic Capture of Target Proteins

  • Kang, Sung-Min;Choi, In-Sung S.;Lee, Kyung-Bok;Kim, Yong-Seong
    • Macromolecular Research
    • /
    • 제17권4호
    • /
    • pp.259-264
    • /
    • 2009
  • Chemical modification of magnetic nanoparticles(MNPs) with functional polymers has recently gained a great deal of attention because of the potential application of MNPs to in vivo and in vitro biotechnology. The potential use of MNPs as capturing agents and sensitive biosensors has been intensively investigated because MNPs exhibit good separation-capability and binding-specificity for biomolecules after suitable surface functionalization processes. In this work, we demonstrate an efficient method for the surface modification of MNPs, by combining surface-initiated polymerization and the subsequent conjugation of the biologically active molecules. The polymeric shells of non-biofouling poly(poly(ethylene glycol) methacrylate)(pPEGMA) were introduced onto the surface of MNPs by surface-initiated, atom transfer radical polymerization(SI-ATRP). With biotin as a model of biologically active compounds, the polymeric shells underwent successful post-functionalization via activation of the polymeric shells and bioconjugation of biotin. The resulting MNP hybrids showed a biospecific binding property for streptavidin and could be separated by magnet capture.

Superconducting high gradient magnetic separation for magnetic substance at sludge powder of hot rolled coolant

  • Kwon, Jun-Mo;Ha, Dong-Woo;Kim, Tae-Hyung;Cho, Mun-Dak;Choi, Woo-Hyuk
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.353-353
    • /
    • 2009
  • It is an important task to construct a recycling society with a low damage on the environment in our century. Magnetic separation is expected to be applied for the industrial waste treatment as an important supporting technology. In the magnetic separation of dry condition, the cohesive force between particles is strong compared with that in the wet condition's magnetic separation. The use of high magnetic field by the superconducting magnet enhances the powder's magnetic substance capture ability of the magnetic separation. In this study, the POSCO's coolant sludge of hot rolled steel was used for the superconducting magnetic separation of dry condition. Cryo-cooled NB-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator.

  • PDF

운동 제어를 위한 운동 포착 및 재현 시스템 (A Motion Capture and Mimic System for Motion Controls)

  • 윤중선
    • 한국정밀공학회지
    • /
    • 제14권7호
    • /
    • pp.59-66
    • /
    • 1997
  • A general procedure for a motion capture and mimic system has been delineated. Utilizing sensors operated in the magnetic fields, complicated and optimized movements are easily digitized to analyze and repreduce. The system consists of a motion capture module, a motion visualization module, a motion plan module, a motion mimic module, and a GUI module. Design concepts of the system are modular, open, and user friendly to ensure the overall system performance. Custom-built and/or off-the-shelf modules are ease- ly integrated into the system. With modifications, this procedure can be applied for complicated motion controls. This procedure is implemented on tracking a head and balancing a pole. A neural controller based on this control scheme dtilizing human motions can easily evolve from a small amount of learning data.

  • PDF

초전도 자기분리에 의한 원재료에서의 철산화물 제거 (The removal of iron oxides from raw materials by superconducting magnetic separator)

  • 권준모;하동우;김태형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.193-193
    • /
    • 2010
  • Magnetic separation is expected to be applied for material refinement as an important supporting technology. In the superconducting magnetic separation, the cohesive force between particles is strong compared with that in the other magnetic separation. The use of high magnetic field by the superconducting magnet enhances the magnetic substance capture ability of the magnetic separation. Industrial raw materials was used for the superconducting magnetic separation. Cry-cooled, NB-Ti superconducting magnet with. 100 mm room temperature bore and 600 mm of height was used for magnetic separator.

  • PDF

Application of magnetic field to iron contained dust capture

  • Huang, Shan;Park, Hae-Woo;Jo, Young-Min;Park, Young-Koo;Kim, Youn-Che
    • 한국응용과학기술학회지
    • /
    • 제31권1호
    • /
    • pp.59-65
    • /
    • 2014
  • Indoor air quality including metro subway is of recent interests in large cities. Inflow air to the inside of the train and circulating air flow through MVAC of stations contain large amount of iron based fine particles. This paper evaluated the collection of such a dust by magnetic filters as comparing to conventional particle capturing mechanisms such as inertia, direct impaction and diffusion. It was found that filtration velocity, magnetic field intensity, and fiber size were the most important parameters for magnetic filtration. Application of magnetic force obviously enhances the collection efficiency particularly in fine modes smaller than 10 mm. However, its effect was found greater in 2.5 mm than submicron particles.

사람의 움직임을 쓴 운동 제어 (A Motion Control utilizing Human Motions)

  • 최원수;손호영;윤중선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.243-247
    • /
    • 1996
  • A general procedure for motion capture and mimic system has been delineated. Utilizing sensors operated in the magnetic fields, complicated and optimized movements are easily digitized to analyze and reproduce. The system consists of a motion capture module, a motion visualization module, a motion plan module, a motion mimic module, and a GUI module. Design concepts of the system are modular, open, and user friendly to ensure the overall system performance. This procedure is being implemented on a virtual cyber cube. and an inverted pendulum. With modifications, this procedure can applied for complicated motion controls.

  • PDF

MRI-Guided Gadolinium Neutron Capture Therapy

  • Ji-Ae Park;Jung Young Kim;Hee-Kyung Kim
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.113-118
    • /
    • 2022
  • Gadolinium neutron capture therapy (Gd-NCT) is a precision radiation therapy that kills cancer cells using the neutron capture reaction that occurs when 157Gd hits thermal neutrons. 157Gd has the highest thermal neutron capture cross section of 254,000 barns among stable isotopes in the periodic table. Another stable isotope, 155Gd, also has a high thermal neutron trapping area (~ 60,700 barns), so gadolinium that exists in nature can be used as a Gd-NCT drug. Gd-NCT is a mixed kinetic energy of low-energy and high-energy ionizing particles, which can be uniformly distributed throughout the tumor tissue, thereby solving the disadvantage of heterogeneous dose distribution in tumor tissue. The Gd complexes of small-sized molecule are widely used as contrast agents for magnetic resonance imaging (MRI) in clinical practice. Therefore, these compounds can be used not only for diagnosis but also therapy when considering the concept of Gd-NCT. This multifunctional trial can look forward to new medical advance into NCT clinical practices. In this review, we introduce gadolinium compounds suitable for Gd-NCT and describe the necessity of image guided Gd-NCT.

자기 메카트로닉스 : 차세대 의공학 및 재활 기기 개발을 위한 센서와 액추에이터의 새로운 접근방법 (Magneto-Mechatronics : A New Approach to Sensors and Actuators for Next-Generation Biomedical and Rehabilitation Devices)

  • 유창호;김성훈
    • 재활복지공학회논문지
    • /
    • 제10권3호
    • /
    • pp.229-236
    • /
    • 2016
  • 자기 센서와 액추에이터는 산업과 의료 분야에서 광범위하게 사용되고 있다. 센서와 액추에이터의 기반의 통합시스템은 기계 및 전자 기기들의 일반적인 조합으로써 메카트로닉스로 정의된다. 최근에 자기 무선 센서와 액추에이터가 개발되어지고, 다양한 분야에서 사용되고 있다. 특히 이 메커니즘은 자성 물질 및 물리적 현상에 관한 것으로 자기의 세기의 따라 달라진다. 그러나 이들 연구의 경계는 명확하지 않다. 따라서, 자기 마이크로 로봇, 자기액추에이터 및 센서들을 포함한 새롭고 정확한 정의가 필요하다. 본 연구에서는 의공학 및 재활을 위한 자기 메카트로닉스의 진보되고 확장된 개념을 혈관 재활을 위한 무선 펌프 시스템과 모션 감지 시스템을 중심으로 소개하고자 한다.

YBCO 초전도 벌크 합성 (Fabrication of YBCO Superconducting Bulk Magnets)

  • 이상헌
    • 한국전기전자재료학회논문지
    • /
    • 제37권4호
    • /
    • pp.407-411
    • /
    • 2024
  • In this study, we fabricated single grain YBCO bulk superconductors with control of the distance between the seed and the upper surface of the YBCO compacts. The magnetic levitation force of the YBa2Cu3O7 superconducting bulk, which corresponds to the energy amount of the superconducting bulk, was measured to be 32.634 N at the center of the bulk where the seed was placed. Under field cooling conditions, a capture magnetic force of 2.17 kG was observed at the center of the bulk. The trapped magnetic force curve corresponding to the stability of the superconducting bulk means that the superconducting specimens were well grown in the form of single grains.