• Title/Summary/Keyword: Magnetic Resonance Imaging/methods

Search Result 1,454, Processing Time 0.026 seconds

Relationship between Graft Appearance on Follow-up MRI and Knee Stability after Double Bundle ACL Reconstruction (이중 다발 전방십자 재건술 후 이식건의 자기공명영상 추시와 슬관절 안정성과의 관계)

  • Sim, Jae Ang;Kwak, Ji Hoon;Lee, Yong Seuk;Kim, Kwang Hui;Nam, Shin Woo;Jun, Sung Soo;Lee, Beom Koo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.128-133
    • /
    • 2012
  • Purpose: This study examined the relationship between graft appearance on follow-up magnetic resonance imaging (MRI) and knee stability after double bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods: For each patient, 1.5 tesla MRI's were obtained. The signal intensity of grafts was divided into 3 grades by Sononda's classification. The course of grafts was divided into two patterns: straight and curved. We assessed Lachman test, KT 2000 arthrometer and anterior drawer stress radiograph using Telos$^{(R)}$ in $30^{\circ}$ knee flexion for anterior stability and evaluated pivot shift test for rotatory stability. The correlation between graft appearance on MRI and the results of knee stability tests was evaluated. Results: The anteromedial (AM) graft was evaluated as being grade 1 in 66.7%, grade 2 in 26.7%, and grade 3 in 6.7% of the cases and the posterolateal (PL) graft was assessed as being grade 1 in 63.3%, grade 2 in 33.3%, and grade 3 in 3.3% of the cases according to the signal intensity. The AM graft was evaluated as being straight in 83.3% and curved in 16.7% of the cases, and the PL graft was assessed as being straight in 86.7% and curved in 13.3% of the cases according to the course. The course of AM graft was correlated with the results of anterior stability tests and the course of PL graft was correlated with the result of rotatory stability test. However, the signal intensity of grafts was not correlated with the results of anterior stability and rotatory stability tests. Conclusion: The course of AM is correlated with anterior stability and the course of PL is correlated with rotatory stability on follow-up MRI after double bundle ACL reconstruction.

  • PDF

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

Assessment of Carotid Geometry by Using the Contrast-enhanced MR Angiography (조영증강 MR 혈관 조영술을 이용한 경동맥 기하학의 평가)

  • Lee, Chung-Min;Ryu, Chang-Woo;Kim, Keun-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.47-55
    • /
    • 2010
  • Purpose : To evaluate the geometry of carotid artery by assessing the images of contrast-enhanced MR angiography (CE-MRA) and interrelationships between the geometry of carotid artery and clinical factors. Materials and Methods : 216 consecutive patients who performed supraaortic CE-MRA with fast spoiled gradient-echo imaging were included. Their medical records were reviewed for variable information including risk factors predictive of generalized atherosclerotic disease (age, hypertension (HTN), diabetes mellitus, hyperlipidema, and smoking), sex, body weight, height, and body mass index (BMI). We reviewed the CE-MRA with carotid origin (3 types), carotid artery tortuosity, angle of internal carotid artery bifurcation, the type of aortic arch branching, and the presence of the coiling of carotid artery. Results : Multinomial logistic regression analysis showed that significantly contributed clinical backgrounds for carotid origin were the age and the BMI. With an increase of age at 1, the probability that the type of carotid origin become from type 1 to type 2 was 0.9 times (p=0.004) in right carotid artery (RCA), 0.9 times (p = 0.031) in left carotid artery (LCA), 0.9 times that are likely to be type3 from type 2 (p<0.001) in RCA and 0.9 times in LCA (p=0.009). Increase in BMI at 1 increased odds of becoming type 2 as 1.1 times (p = 0.067) in RCA, 1.1 times (p=0.009) in LCA and increased chance of becoming type 3 as 1.2 times (p = 0.001) in RCA, 1.2 times (p=0.003) in LCA. Mean value of right and left carotid tortuosity were $240.9{\pm}69.0^{\circ}$and $154.4{\pm}55.0^{\circ}$, respectively. Conclusion : The BMI, age, sex and presence of HTN affects the geometry of carotid arteries, the site of origin and tortuosity of carotid artery specifically.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Does the ADC Map have Additional Clinical Significance Compared to the DWI in the Brain Infarction? (뇌경색에서 확산강조영상과 비교하여 현성확산계수 지도의 부가적인 임상적 중요성이 있는가?)

  • Choi, Sunseob;Ha, Dong-Ho;Kang, Myong-Jin;Lee, Jin Hwa;Yoon, Seong Kuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.267-274
    • /
    • 2013
  • Purpose : To re-evaluate additional clinical significance of the apparent diffusion coefficient (ADC) map in the inference of infarction stage, authors studied the evolution patterns of the DWI and the ADC map of the brain infarction. Materials and Methods: In 127 patients with cerebral infarctions, including follow-up checks, 199 studies were performed. They were classified as hourly (117 studies)-, daily (108 studies)-, weekly (62 studies)-based groups. The signal intensity (SI) was measured at the core of the infarction and contralateral area with ROI of 0.3 $cm^2$ or more on the images of the DWI and the ADC map, and calculated the ratios of SI and ADC value of the infarction area / contralateral normal area, and compared the patterns of the change according to the evolution. Results: Infarction was detected as early as 1 hour after the attack, and the ratio of SI in the DWI became over than 2 after 12 hours, which showed a plateau until the 6th day. Thereafter, it decreased slowly to 1 on the 30th day, and changed to lower SI than the surrounding brain. The ratio in the ADC map became 0.46 in 24 hours after the attack, and increased slowly to 1 in the 15th day. Thereafter, it became a higher value than the surrounding brain. Overall, the ratio in the ADC map changed earlier than in the DWI, and the ratio curves showed inverse pattern each other according to the evolution of the infarction. Conclusion: The evolution patterns of infarction on the ADC map showed an inverse curve of DWI curve, which means that the ADC value is accurately predictable from DWI, and the ADC map joined with the DWI seems helpful in the determination of subacute infarction between 15 to 30 days.

Functional Magnetic Resonance Imaging of Brain Reactivity to Insomnia-Related vs. General Anxiety-Inducing Stimuli in Insomnia Patients with Subjective-Objective Discrepancy of Sleep (주관적-객관적 수면시간 차이를 보이는 불면증 환자에서 일반적 불안에 비해 불면증 관련 자극으로 인한 뇌활성에 관한 기능적 자기공명영상 연구)

  • Kim, Nambeom;Lee, Jae Jun;Cho, Seo-Eun;Kang, Seung-Gul
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.1
    • /
    • pp.24-31
    • /
    • 2020
  • Objectives: Subjective-objective discrepancy of sleep (SODS) is a common symptom and one of the major phenotypes of insomnia. A distorted perception of sleep deficit might be related to abnormal brain reactivity to insomnia-related stimuli. We aimed to investigate differences in brain activation to insomnia-related stimuli vs. general anxiety-inducing stimuli among insomnia patients with SODS, insomnia patients without SODS, and healthy controls (HCs). Methods: All participants were evaluated for subjective sleep status using a sleep diary and questionnaires; occult sleep disorders and objective sleep status were assessed using polysomnography and actigraphy. Task functional magnetic resonance imaging was performed during insomnia-related stimuli (Ins) and general anxiety-inducing stimuli (Gen). Brain reactivity to Ins versus Gen was compared among insomnia with SODS, insomnia without SODS, and HC groups, and a combined insomnia disorder group (ID, insomnia with and without SODS) was also compared with HCs. Results: In the insomnia with SODS group compared to the insomnia without SODS group, the right precuneus and right supplementary motor areas showed significantly increased BOLD signals in response to Ins versus Gen. In the ID group compared to the HC group, the left anterior cingulate cortex showed significantly increased BOLD signals in response to Ins versus Gen. Conclusion: The insomnia with SODS and ID groups showed higher brain activity in response to Ins versus Gen, while this was not observed in the insomnia without SODS and HC groups, respectively. These results suggest that insomnia patients with sleep misperception are more sensitive to sleep-related threats than general anxiety-inducing threats.

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

Arthroscopic Repair of Traumatic Subscapularis Tendon Tear (외상성 견갑하건 파열의 관절경하 봉합술)

  • Cho, Su-Hyun;Cho, Hyung-Lae;Ku, Jung-Hoei;Hwang, Tae-Hyok;Park, Man-Jun;Choi, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.3
    • /
    • pp.180-187
    • /
    • 2010
  • Purpose: Rotator cuff tears involving the subscapularis are less common than those involving the superior and posterior rotator cuff. The purpose of the present study was to report the clinical results of repair of isolated traumatic tears of the subscapularis tendon. Materials and Methods: Fifteen patients (13 males, 2 females; mean age 46.2 years; range 35 to 52) with unilateral ruptures of the subscapularis tendon after trauma who underwent arthroscopic repair between February 2003 and October 2008 were reviewed retrospectively. All the cases were isolated tears of the subscapularis without the involvement of any other rotator cuff tendon and were followed for at least two years (mean 28 months). The entire subscapularis was involved in 9 cases and the tear was localized to the upper two thirds in 6 cases. The preoperative and postoperative status of patients with isolated subscapularis tears were analyzed using the Constant Score, American Shoulder and Elbow Society Index (ASES Index) and postoperative integrity was determined through magnetic resonance imaging. Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up. The constant shoulder score improved from 41.5 to 81.3 points (P<0.05) compared to before surgery and ASES index improved from 46.4 to 89.6 points (P<0.05) postoperatively. Thirteen patients (87%) were satisfied with the result of the treatment. The total tears were significantly more improved by surgery than the partial tears. In 12 of 15 patients (80%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 13 months postoperatively. The postoperative score was significantly lower for the patients with a failed repair than it was for those with an intact repair (P<0.05). Conclusion: Repair of traumatic isolated subscapularis tears through arthroscopic techniques effectively restores patient function with regard to pain, mobility, strength and postoperative tendon integrity. The postoperative integrity of the repair correlates with the functional results and the total tears were more improved by surgery than the partial tears, but future studies may be needed.

  • PDF

Effect of Facet Tropism on the Degeneration of the Cervical Facet Joint and Intervertebral Disc (경추의 후관절 퇴행과 추간판 퇴행에서 후관절 비대칭성의 영향)

  • Chung, Sung Soo;Park, Chan-Ho;Heo, Ki Seong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.413-418
    • /
    • 2021
  • Purpose: To investigate the effect of facet tropism on the degeneration of facet joint and intervertebral disc in the cervical spine. Materials and Methods: From January 2017 to December 2018, cervical tropism of 100 patients at the C5/6 level was analyzed retrospectively. In computed tomography (CT), the orientation and tropism of the facet joint with respect to the sagittal, coronal, and horizontal planes were measured. Regression of the facet joint in magnetic resonance imaging (MRI) and CT was assessed using a grading system. Intervertebral disc degeneration was assessed and divided into five grades on MRI. For the left and right asymmetry, a difference between two facet angles of less than 7° was classified as the control group, more than 7° was classified as the tropism group. Results: The mean age of the patients was 55.44±12.3 years (31-81 years) in the tropism group and 55.66±10.7 years (32-76 years) in the control group. In the tropism group, 32 were male and 18 were female. In the control group, 24 were male and 26 were female. Facet joint degeneration was identified in 24 patients (48.0%) in the tropism group and 14 patients (28.0%) in the control group, showing a significant difference. Intervertebral disc degeneration was identified in 29 patients (58.0%) in the tropism group and 17 patients (34.0%) in the control group, showing a significant difference. Multivariate revealed, tropism to be a factor that affected the facet joint and intervertebral disc degeneration. Conclusion: Facet joint and intervertebral disc degeneration occurred significantly in the tropism group, and tropism is a factor affecting the degeneration of facet joint and intervertebral disc in the C5/6 level.

Risk Factor for Poor Clinical Outcome in Patients with Retear after Repair of the Rotator Cuff (회전근 개 파열 봉합술 후 재파열 환자에서 불량한 임상 결과의 원인 인자)

  • Lee, Hee Jae;Joo, Il Han;Hur, Jeong Min;Oh, Hyun Keun;Lee, Bong Gun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.61-67
    • /
    • 2021
  • Purpose: To evaluate the prognostic factors affecting poor functional outcomes in patients with retear after rotator cuff repair. Materials and Methods: From January 2013 to December 2018, among 631 patients who underwent arthroscopic repair of a rotator cuff tear, 42 patients, who could be followed-up for more than one year and showed a retear of the repaired cuff on magnetic resonance imaging (MRI), were collected retrospectively. The preoperative demographic data, range of motion, American Shoulder and Elbow Surgeons (ASES) score, fatty degeneration, and tear progression on postoperative MRI, as well as other factors that could affect the clinical outcomes, were analyzed. Patients who scored <80 points on the ASES score were allocated to the poor function group. The risk factors for poor clinical outcomes were compared with the group with ASES scores of 80 or above. Results: The postoperative functional results in the group with retear (n=42) after arthroscopic rotator cuff repair showed significant improvement. Univariate analysis revealed the preoperative visual analogue scale (VAS) score and tear progression to have associations with a poor shoulder function. In addition, subscapularis repair was found to be associated with a good shoulder function. The preoperative VAS score and tear progression except for subscapularis repair were independent factors associated with poor clinical outcomes according to multivariate logistic regression analysis. Conclusion: In patients with retear after rotator cuff repair, the preoperative VAS and tear progression in postoperative MRI are factors predicting a poor functional outcome.