• 제목/요약/키워드: Magnetic Probe

검색결과 261건 처리시간 0.022초

Development of Magnetic Phase Detection Sensor for the Steam Generator Tube in Nuclear Power Plants

  • Son, De-Rac;Joung, Won-Ik;Park, Duck-Gun;Ryu, Kwon-Sang
    • Journal of Magnetics
    • /
    • 제14권2호
    • /
    • pp.97-100
    • /
    • 2009
  • A new eddy current testing probe was developed to separate the eddy current signal distortion caused by permeability variation clusters and ordinary defects created in steam generator tubes. Signal processing circuits were inserted into the probe to increase the signal-to-noise ratio and allow digital signal transmission. The new probe could measure and separate the magnetic phases created in the steam generator tubes in the operating environment of a nuclear power plant. Furthermore, the new eddy current testing probe can measure the defects in steam generator tubes as rapidly as a bobbin probe with enhanced testing speed and reliability of defect detection.

Cutoff Probe를 이용한 자화유도결합 플라즈마의 특성 연구 (A Study on Magnetized Inductively Coupled Plasma Using Cutoff Probe)

  • 손의정;김동현;이호준
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1706-1711
    • /
    • 2016
  • Electromagnetic wave simulation was performed to predict characteristics of manufactured cutoff probe at low temperature magnetized plasma medium. Microwave cutoff probe is designed for research the properties of magnetized inductively coupled plasma. It was shown that the cutoff probe method can safely be used for weakly magnetized high density plasma sources. Cutoff probe system with two port network analyzer has been prepared and applied to measure electron density distributions in large area, 13.56MHz driven weakly magnetized inductively coupled plasma source. The results shown that, the plasma frequency confirmed cut-off characteristics in low temperature plasma. Especially, cut-off characteristics was found at upper hybrid resonance frequency in the environment of the magnetic field. In case of a induced weak magnetic field in inductively coupled plasma, plasma density estimated from the cutoff frequency in the same way at unmagnetized plasma due to nearly same plasma frequency and upper hybrid resonance frequency. The plasma density is increased and uniformity is improved by applying a induced weak magnetic field in inductively coupled plasma.

자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구 (Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension)

  • 김의석;안형준;장인배;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석 (Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe)

  • 이효연;곽기성;이준규;유재은;염도준
    • Progress in Superconductivity
    • /
    • 제11권2호
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.

Low-ε Static Probe Development for 15N-1H Solid-state NMR Study of Membrane Proteins for an 800 MHz NB Magnet

  • Park, Tae-Joon;Choi, Sung-Sub;Jung, Ji-Ho;Park, Yu-Geun;Kim, Yongae
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.823-826
    • /
    • 2013
  • A low-${\varepsilon}$ solid-state NMR(Nuclear Magnetic Resonance) probe was developed for the spectroscopic analysis of two-dimensional $^{15}N-^1H$ heteronuclear dipolar coupling in dilute membrane proteins oriented in hydrated and dielectrically lossy lipid environments. The system employed a 800 MHz narrow-bore magnet. A solenoid coil strip shield was used to reduce deleterious RF sample heating by minimizing the conservative electric fields generated by the double-tuned resonator at high magnetic fields. The probe's design, construction, and performance in solid-state NMR experiments at high magnetic fields are described here. Such high-resolution solid-state NMR spectroscopic analysis of static oriented samples in hydrated phospholipid bilayers or bicelles could aid the structural analysis of dilute biological membrane proteins.

A Three-dimensional Magnetic Field Mapping System for Deflection Yoke of Cathode-Ray Tube

  • Park, K.H.;Yoon, M.;Kim, D.E.;Lee, S.M.;Joo, H.D.;Lee, S.D.;Yang, W.Y.
    • Journal of Information Display
    • /
    • 제3권4호
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we introduce an efficient three-dimensional magnetic field mapping system for a Deflection Yoke (DY) in Cathode-Ray Tube (CRT). A three-axis Hall probe mounted in a small cylindrical bar and three-stepping motors placed in a non-magnetic frame were utilized for the mapping. Prior to the mapping starts, the inner contour of DY was measured by a laser sensor to make a look-up table for inner shape of DY. Three-axis magnetic fields are then digitized by a three-dimensional Hall probe. The results of the mapping can be transformed into various output formats such as multi pole harmonics of magnetic fields. Field shape in one, two and three- dimensional spaces can also be displayed. In this paper, we present the features of this mapping device and some analysis results.

노이즈 소스 근거리장에 위치한 금속 차폐막의 차폐효과 분석 (Analysis for Shielding Effectiveness of Metal Shielding Layer within Near-Field of Noise Source)

  • 이원선;이원희;허정
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.59-65
    • /
    • 2019
  • 마그네틱 프로브와 노이즈 소스의 근거리장에 금속 차폐막이 놓여있을 때 차폐막 두께에 따른 EMI 차폐효과를 분석하였다. 노이즈 소스로는 마이크로스트립 라인을 이용하였으며, 금속 차폐막 재료로는 그래파이트와 페라이트를 선정하였다. 마그네틱 프로브는 IEC 61967-6 방식을 적용하여 마그네틱 프로브를 이용한 전자기 방사 측정 방법을 사용하였다. 마이크로스트립 라인과 마그네틱 프로브 사이의 투과계수를 분석하였고, 둘 사이의 거리는 단일 차폐막일 경우 1 mm, 다중 차폐막일 경우 5 mm로 수행하였다. 차폐막의 두께는 5 um, 10 um, 30 um, 50 um 으로 변화시켰다. 주파수를 150 kHz에서 1 GHz까지 변화시켰을 경우 최대 44.9 dB의 SE(Shielding Effectiveness)를 얻었다.

축 방향으로 자화된 용량 결합형 RF 플라즈마의 특성 연구 (A study on the characteristics of axially magnetized capacitively coupled radio frequency plasma)

  • 이호준;태흥식;이정해;신경섭;황기웅
    • 한국진공학회지
    • /
    • 제10권1호
    • /
    • pp.112-118
    • /
    • 2001
  • 본 논문에서는 축 방향으로 자화된 용량결합형 13.65 MHz/40 KHz RF 방전에서 Langmuir Probe, Emissive Probe를 통해 이온 전류 밀도, 전자 온도, 플라즈마 전위의 자장 의존성 및 자기 바이어스 전위를 조사하였다. 자장을 인가함으로서 실험변수 범위 내에서 최대 3배의 이온 전류밀도증가를 얻었고 점화가능한 기체 압력의 최저값을 줄일 수 있었다. 플라즈마가 자화된 경우 공간 전위는 평균적으로 감소하였고 RF 전압의 한주기 동안 시 변동폭이 크게 증가하였다. 플라즈마 전위의 자장 의존성은 Particle-in-Cell Simulation을 수행하여 실험 결과와 비교하였다. 대표적 실험 조건에서 전자 온도는 자장에 따라 약 4 eV에서 5 eV로 약간 증가하는 경향을 보였으나 방전 주파수를 40 KHz로 줄인 경우 1.8 eV에서 0.8 eV로 감소하였다. 실험 장치의 응용 예로서 플루오로 카본 가스에 의한 식각실험이 수행되었다. 자화 플라즈마의 산화막 식각속도 증가를 확인함으로서 축방향 자장이 실제 공정에 긍정정인 영향을 미침을 확인 할 수 있었다.

  • PDF

PHR 자기센서를 적용한 탐침형 전류 프로브 (A pin type current probe using Planar Hall Resistance magnetic sensor)

  • 이대성;이남영;홍성민;김철기
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.342-348
    • /
    • 2021
  • For the characterization or failure analysis of electronic devices such as PCB (printed circuit boards), the most common method is the measurement of voltage waveforms with an oscilloscope. However, because there are many types of problems that cannot be detected by voltage waveform analysis, several other methods such as X-ray transmission, infrared imaging, or eddy current measurement have been applied for these analyses. However, these methods have also been limited to general analyses because they are partially useful in detecting physical defects, such as disconnections or short circuits. Fundamentally current waveform measurements during the operation of electronic devices need to be performed, however, commercially available current sensors have not yet been developed, particularly for applications in highly integrated PCB products with sub-millimeter fine pitch. In this study, we developed a highly sensitive PHR (planar hall resistance) magnetic sensor for application in highly integrated PCBs. The developed magnetic sensor exhibited sufficient features of an ultra-small size of less than 340 ㎛, magnetic field resolution of 10 nT, and current resolution of 1 mA, which can be applicable for PCB analyses. In this work, we introduce the development process of the magnetic sensing probe and its characteristic results in detail, and aim to extend this pin-type current probe to applications such as current distribution imaging of PCBs.

Development of Pocket Insertion style Magnetic Curer that Apply $2^{loop}\;3^{pulsed}$ Variable Magnetic type Probe for Urinary Treatment

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • 제6권1호
    • /
    • pp.73-79
    • /
    • 2008
  • Result that study magnet nerve curer for treatment induced current generation and current of ion for development in main point incontinence, prostate, sphincter, nervous system, rigidity, headache, retrogression arthritis, ligament damage, Rheumatism arthritis, peripheral nerve etc., can classify by 4. Embodied do first, full bridge magnet occurrence chapter, and communication with PC is available, confirmed various action loops an experiment. Could confirm correct treatment probe second, woman and man disease person. Third, derived so that healing may be possible naturally by addition of apron form according to disease. Because composition of finally, treatment probe composes by act of negative plate form, manufacture is easy and cooling designed for easy direction. More superior result of cooling appeared than existing in incidental and ingredients, cooling efficiency, composition, complexity, convenience etc. that expense and composition manufacture very straightforwardly and experimental by 2 - Tank ways.