• Title/Summary/Keyword: Magnetic Dipole Moment

Search Result 23, Processing Time 0.028 seconds

Improved closed-form Green's function for a horizontal magnetic dipole in a parallel-plate waveguide (평행평판 도파관내 수평자기쌍극자에 대한 개선된 단순함수형태의 그린함수)

  • 이영순;권호상;조영기
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.5
    • /
    • pp.24-32
    • /
    • 1998
  • Spatial green's functions for a horizontal magnetic dipole in a parallel-plate waveguide are expressed in an improved closed-form with two-level approximation of the spectral green's functions. The results evaluated by the present closed-from green's function with two-level approximation are compard with those obtained the previous closed-form green's function with one-level approximation. The present results are observed to be more acurate than the previous results over wide frequency range as well as whole spatial range. The combination of the present closed-form green's functions and the moment mehtod may help in analyzing the problem of EMP coupling through an aperture into a parallel-plat waveguide and the microstrip slot antenna with a reflector.

  • PDF

Performance Analysis of Magnetic Torquer for Spacecraft Control

  • Lee, Seon-Ho;Seo, Hyun-Ho;Rhee, Seung-Wu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1313-1317
    • /
    • 2005
  • This paper presents the overall design, manufacture, and test result of the high capacity (more than 150 Am^2) magnetic torquer for the use of satellite control. To provide an electrical current to the magnetic torquer, the driving electronics is also constructed. The integration and test of the magnetic torquer and its driving electronics are performed via the magnetic field measurement according to the distance and the magnetic torque measurement with torque-meter. To compare the performance obtained from the test results we also perform computer simulation with three-dimensional model.

  • PDF

Terahertz Spectral Characteristics of Electrolyte Solutions under Different Magnetic Fields

  • Shao, Siyu;Huang, Haiyun;Peng, Bo;Wang, Guoyang;Ye, Ping;Wang, Jiahui;Su, Bo;Cui, Hailin;Zhang, Cunlin
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.337-343
    • /
    • 2022
  • Microfluidic chips are new devices that can manipulate liquids at the micrometer level, and terahertz (THz) time-domain spectroscopy has good applicability in biochemical detection. The combination of these two technologies can shorten the distance between sample and THz wave, reduce THz wave absorption by water, and more effectively analyze the kinetics of biochemical reactions in aqueous solutions. This study investigates the effects of different external magnetic field intensities on the THz transmission characteristics of deionized water, CuSO4, CuCl2, (CH3COO)2Cu, Na2SO4, NaCl, and CH3COONa; the THz spectral intensity of the sample solutions decrease with increasing intensity of the applied magnetic field. Analysis shows that the magnetic field leads to a change in the dipole moment of water molecules in water and electrolyte solutions, which enhances not only the hydrogen-bond networking ability of water but also the hydration around ions in electrolyte solutions, increasing the number of hydrogen bonds. Increasing the intensity of this magnetic field further promotes the hydrogen-bond association between water molecules, weakening the THz transmission intensity of the solution.

Comparison of Three Modeling Methods for Identifying Unknown Magnetization of Ferromagnetic Thin Plate

  • Choi, Nak-Sun;Kim, Dong-Wook;Yang, Chang-Seob;Chung, Hyun-Ju;Kim, Hong-Joon;Kim, Dong-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.799-805
    • /
    • 2011
  • This study presents three different magnetization models for identifying unknown magnetization of the ferromagnetic thin plate of a ship. First, the forward problem should be solved to accurately predict outboard magnetic fields due to the magnetization distribution estimated at a certain time. To achieve this, three different modeling methods for representing remanent magnetization (i.e., magnetic charge method, magnetic dipole array method, and magnetic moment method) were utilized. Material sensitivity formulas containing the first-order gradient information of an objective function were then adopted for an efficient search of an optimum magnetization distribution on the hull. The validity of the proposed methods was tested with a scale model ship, and field signals predicted from the three different models were thoroughly investigated with reference to the experimental data.

Synthesis and Photoinduced Magnetic Properties of a Mn12 Single Molecule Magnet by the cis-trans Isomerism of Azobenzene

  • George, Sheby M.;Kim, Jin-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1143-1146
    • /
    • 2009
  • [$Mn_{12}O_{12}(azo-L)_{16}(H_2O)_4$] (1), a new Mn12 single molecule magnet containing a photochromic azobenzene ligand, has been successfully synthesized by substitution of acetate ligand of Mn12 with 6-[4-{4-hexyloxyphenyl( azo)}-phenoxy]hexanoic-1-acid. The reversible photoisomerization of the azobenzene group was confirmed by UV-visible absorption spectroscopy. The temperature and field dependence of dc susceptibility and the temperature and the frequency dependence of ac susceptibility were measured for the cis and the trans isomer of 1. The magnetization value of the cis isomer in dc measurement is higher than that of the trans isomer. The cis isomer of 1 has a slower relaxation because cis-trans photoisomerization of the azobenzene group in peripheral ligands induces changes in its structure and dipole moment.

Study on Separation Distance to Protect Radio Service from Inductive System (유도성 시스템으로부터 무선기기 보호를 위한 이격 거리에 관한 연구)

  • Lee, Il-Kyoo;Shim, Yong-Sup;Min, Kyoung-Il;Cha, Jae-Sang;Lee, Kyong-Gun
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.1
    • /
    • pp.103-108
    • /
    • 2011
  • This paper is related radio interference from inductive system to radio device in home and industrial environment according to increasing the usage of inductive system. In order to analyze interference from magnetic field strength of inductive system, interference model was suggested and explain the method to calculate separation distance by using conversion that from magnetic field strength to magnetic dipole moment based on suggested interference model. Also, scenario that interference occur between inductive system and radio device was shown and the separation distance between inductive system and radio device was calculate with that scenario. The suggested method in this paper will be used to secure the compatibility between inductive system and radio device.

Analysis of a CubeSat Magnetic Cleanliness for the Space Science Mission (우주과학임무를 위한 큐브위성 자기장 청결도 분석)

  • Jo, Hye Jeong;Jin, Ho;Park, Hyeonhu;Kim, Khan-Hyuk;Jang, Yunho;Jo, Woohyun
    • Journal of Space Technology and Applications
    • /
    • v.2 no.1
    • /
    • pp.41-51
    • /
    • 2022
  • CubeSat is a satellite platform that is widely used not only for earth observation but also for space exploration. CubeSat is also used in magnetic field investigation missions to observe space physics phenomena with various shape configurations of magnetometer instrument unit. In case of magnetic field measurement, the magnetometer instrument should be far away from the satellite body to minimize the magnetic disturbances from satellites. But the accommodation setting of the magnetometer instrument is limited due to the volume constraint of small satellites like a CubeSat. In this paper, we investigated that the magnetic field interference generated by the cube satellite was analyzed how much it can affect the reliability of magnetic field measurement. For this analysis, we used a reaction wheel and Torque rods which have relatively high-power consumption as major noise sources. The magnetic dipole moment of these parts was derived by the data sheet of the manufacturer. We have been confirmed that the effect of the residual moment of the magnetic torque located in the middle of the 3U cube satellite can reach 36,000 nT from the outermost end of the body of the CubeSat in a space without an external magnetic field. In the case of accurate magnetic field measurements of less than 1 nT, we found that the magnetometer should be at least 0.6 m away from the CubeSat body. We expect that this analysis method will be an important role of a magnetic cleanliness analysis when designing a CubeSat to carry out a magnetic field measurement.

Basic theory of Dielectric Relaxation Spectroscopy and Studies of Electrolyte Structure (유전체 이완 분광법의 원리 및 이를 이용한 전해액 미시구조 연구)

  • Koo, Bonhyeop;Hwang, Sunwook;Lee, Hochun
    • Journal of the Korean Electrochemical Society
    • /
    • v.22 no.2
    • /
    • pp.53-59
    • /
    • 2019
  • To examine the solution structure of electrolytes, it is very important to understand ion-ion and ion-solvent interactions. In this review, we introduce the basic principle of dielectric relaxation spectroscopy (DRS) and studies of electrolyte structure. DRS is a type of impedance method, which measures the dielectric properties of electrolytes over a high frequency domain at levels of tens of GHz. Therefore, DRS provides information on the different polar chemical species present in the electrolyte, including the type and concentration of free solvents and ion pairs with dipole moments. The information of DRS is complementary to the information of conventional analytical techniques (Infrared/Raman spectroscopy, nuclear magnetic resonance (NMR), etc.) and thus enables a broad understanding of electrolyte structure.

Synthesis, Spectral, Characterization, DFT and Biological Studies of New 3-[(3-Chlorophenyl)-hydrazono]-pentane-2,4-dione Metal Complexes

  • Sadeek, Sadeek A.;Zordok, Wael A.;El-Farargy, Ahmed F.;El-Desoky, Sameh I.
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.2
    • /
    • pp.169-178
    • /
    • 2014
  • A new series of metal complexes of V(IV), Pd(II), Pt(IV), Ce(IV) and U(VI) with 3-[(3-chlorophenyl)-hydrazono]-pentane-2,4-dione (Cphpd) were synthesized and characterized by elemental analysis, molar conductivity, magnetic moment measurements, UV-vis, FT-IR and $^1H$ NMR as well as TG-DTG techniques. The data indicated that the Cphpd acts as a bidentate ligand through the hydrazono nitrogen and one keto oxygen. The kinetic parameters have been evaluated by using Coats Redfern (CR) and Horowitz-Metzeger (HM) methods. The thermodynamic data reflected the thermal stability for all complexes. The calculated bond length and the bond stretching force constant, F(U=O), values for $UO_2$ bond are $0.775{\AA}$ and $286.95Nm^{-1}$. The bond lengths, bond angles, dipole moment and the lowest energy model structure of the complexes have been determined with DFT calculations. The antimicrobial activity of the synthesized ligand and its complexes were screened.

Calculation of the Magnetic Moments for Transition Metal Complexes (Ⅱ). The Magnetic Moments for Distorted Octahedral $[V(III)A_3B_3]$ Type Complexes and the Contribution of $^3T_1$ Term to the Dipole Moments and Polarizability [A and B = O, Cl, N or Br] (전이원소착물의 자기모멘트의 계산 (제2보). $t^2_2$ 전자구조를 갖는 일그러진 판면체 $[V(III)A_3B_3]$형태 착물의 자기모멘트와 쌍극자모멘트 및 편극율에 대한 $^3T_1$항의 기여분 [A 와 B = O, Cl, N 또는 Br])

  • Sangwoon Ahn;Se Woung Oh;Kee Hag Lee;Eu Suh Park
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.4
    • /
    • pp.269-279
    • /
    • 1980
  • A method for calulation of the magnetic moments for both octahedral and distorted octahedral $[V(III)A_3B_3]$ type complexes, all with $t^2_2$ configuration, has been developed [A and B = O, Cl, N, F or Br]. The calculated magnetic moments by this method are in reasonable agreements with the experimental values. The calculated magnetic moments for distorted octahedral $[V(III)A_3B_3]$/TEX> type complexes decrease as the extent of tetragonal distortion increases.The effects of k (orbital reduction faction factor), $\xi'$/TEX> and temperature on the magnetic moments are also investigated.A new method for calculation of the contribution of $^3T_1$ molecular orbitals to the dipole moment and polarizability has also developed. The calculated contribution of $^3T_1$ molecular orbitals falls in the reasonable range of values.

  • PDF