• Title/Summary/Keyword: Mach Zehnder Interferometer

Search Result 197, Processing Time 0.028 seconds

Analysis of the wavefront of laser beam based on the fourier analysis method (Fourier 분석법에 의한 레이저 출력 광속의 위상파면 분석에 관한 연구)

  • 최승호;박대윤;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.445-452
    • /
    • 1994
  • The automatic analysis of the wavefront of laser beam is simulated numerically, and is applied to get the wavefront of the output beam of LD-pumped cw Nd:YAG laser, experimentally. The automatic analysis tool was developed by utilizing Fourier analysis method, and its usefulness is proved through numerical simulation. The wavefront error due to the analysis tool is known to be less than A/30. In order to find the wavefront of Nd:YAG laser beam, its interference fringe is obtained from Mach-Zehnder interferometer. The wavefront calculated from the developed tool has the shape of nearly spherical wavefront and the maximum distortion is about 0.8 .A.. 8 .A..

  • PDF

Fiber Optic AC Voltage Sensor Using Fringe Counting (간섭무늬의 변화갯수 측정을 이용한 광섬유 교류전압센서)

  • 김봉규;김병윤;김만식
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.158-165
    • /
    • 1994
  • A fiber optic voltage sensor is demonstrated with a new signal processing scheme that displays the magnitude and the waveform of applied voltage with immunity from the signal frequency change. The sensor is based on a Mach-Zehnder interferometer with a PZT phase modulator as a sensing element. We observed a linear relationship between applied voltage and the number of fringe shift during a half cycle of the ac signal. The temperature dependence of the sensor output is experimentally evaluated over the temperature range from $-20^{\circ}C to 80^{\circ}C$. It is demonstrated that the detrimental polarization modulation effect can be overcome by using polarization maintaining fibers or a half-wave plate. plate.

  • PDF

Co-Fe-B 자왜변환기를 이용한 간섭계형 광섬유 자계센서의 동작특성

  • 이경식
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.474-479
    • /
    • 1993
  • An interferometric fiber-optic magnetic field sensor is constructed by bonding a Co-Fe-B metallic glass transducer developed here by the melt-spun method to a single mode fiber arm in the fiber Mach-Zehnder interferometer and is tested. The bias field for the peak ac-sensitivity was observed near 0.97 Oe and the minimum detectable magnetic field was 3.9${\times}10^{-5}$ Oe(rms)/${\sqrt{Hz}}$ a 3 kHz. The output of the ac field sensor becomes saturated near the input signal level of 1 Oe(rms). The Co- Fe-B transducer exhibits peak response near 500 Hz.

  • PDF

Failure detection of composite structures using a fiber Bragg grating sensor (광섬유 브래그 격자 센서를 이용한 복합재 구조물의 파손 검출)

  • 고종인;김천곤;홍창선
    • Composites Research
    • /
    • v.17 no.2
    • /
    • pp.28-33
    • /
    • 2004
  • Failure detection in a cross-ply laminated composite beam under tensile loading were performed using a fiber Bragg grating (FBG) sensor. A Passive Mach-Zehnder interferometric demodulator was proposed to enhance sensitivity and bandwidth. The proposed FBG sensor system without active device such as a phase modulator is very simple in configuration, easy to implement and enables the measurement of high-frequency vibration with low strain amplitude such as impact or failure signal. Failure signals detected by a FBG sensor had offset value corresponding to the strain shift with vibration at a maximum frequency of several hundreds of kilohertz. at the instant of transverse crack propagation in the 90 degree layer of composite beam.

40 Gbps All-Optical 3R Regeneration and Format Conversion with Related InP-Based Semiconductor Devices

  • Jeon, Min-Yong;Leem, Young-Ahn;Kim, Dong-Churl;Sim, Eun-Deok;Kim, Sung-Bock;Ko, Hyun-Sung;Yee, Dae-Su;Park, Kyung-Hyun
    • ETRI Journal
    • /
    • v.29 no.5
    • /
    • pp.633-640
    • /
    • 2007
  • We report an experimental demonstration of 40 Gbps all-optical 3R regeneration with all-optical clock recovery based on InP semiconductor devices. We also obtain alloptical non-return-to-zero to return-to-zero (NRZ-to-RZ) format conversion using the recovered clock signal at 10 Gbps and 40 Gbps. It leads to a good performance using a Mach-Zehnder interferometric wavelength converter and a self-pulsating laser diode (LD). The self-pulsating LD serves a recovered clock, which has an rms timing jitter as low as sub-picosecond. In the case of 3R regeneration of RZ data, we achieve a 1.0 dB power penalty at $10^{-9}$ BER after demultiplexing 40 Gbps to 10 Gbps with an eletroabsorption modulator. The regenerated 3R data shows stable error-free operation with no BER floor for all channels. The combination of these functional devices provides all-optical 3R regeneration with NRZ-to-RZ conversion.

  • PDF

Final Diffraction Patterns of the Beam Splitters used in the Soft XRay Interferometer by a He-Ne Laser

  • Oh, Chul-Han;Choi, Dae-Uk;Park, Sung-Jin;Howells, M.R.;Moller, E.J.
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.7-10
    • /
    • 2000
  • The soft x-ray(10nm-100nm) interferometer is a modified Mach-Zehnder type interferometer and it consists of two beam-splitters and four totally reflecting mirrors. The beam-splitters used here are 50% transmission and 50% reflection grating type. The diffraction patterns of beam splitters(1st B.S.) were investigated with a He-Ne laser. The diffraction patterns produced by the soft x-ray interferometer (2nd B.S.) were also investigated in intensities positions. The diffraction patterns of 20 degree grazing incidence on the beam splitters(1st B.S.) show a circular array of spots. Both the reflected and the transmitted beams show the same patterns but symmetric circles on the screen. The maximum intensity appears roughly when n is in the zeroth and odd orders and the suppressed peak(missing order) appears when n is in even orders. Intensities of 3 center fringes(n = 0, $\pm$1) are stronger than others. These results confirm the reduced grating equation and make agree with the intensity distribution function. It was found that the final patterns produced by the soft x-ray interferometer (2nd B.S.) consisted of fine fringes which were caused by two of three diffraction beams that were arrived at the second beam-splitter.

Fabrication of Planar Type Optical Waveguide for the Application of Biosensor and Detection Characteristics of Staphylococcus Aureus (바이오센서용 평판형 광도파로 센서 제작 및 황색포도상구균 검출 특성)

  • Kim, Jun-Hyong;Yang, Hoe-Young;Yu, Chong-Hee;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.223-223
    • /
    • 2009
  • In this paper, designed and simulated Power Splitter (PS) integrated Mach-Zehnder interferometer (MZI) based planar type optical waveguide devices (which is called here a PS-MZI). The PS-MZI optical waveguide sensor was preceded by a Y-junction, which splits the input power between the sensor, and a reference branch, to minimize the effect of optical power variations. The PS-MZI optical waveguide sensor induced changing phases of the incident beam, which had fallen upon the waveguide through computer simulation, according to the small changes in the index of refraction, thus beam intensity was changed. The waveguide were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The fabrication of PS-MZI optical waveguide sensor was performed by a conventional planar lightwave circuit (PLC) fabrication process. The PS-MZI optical waveguide that was fabricated to be applied as a biosensor revealed a low insertion loss and a low polarization-dependent loss. After having etched the over-clad at the sensor part in the MZI optical waveguide that was fabricated, Ti deposition was made on the adhesion layer, and then Au thin-film deposition was carried out thereon. In addition, its optical properties were measured by having changed the index of refraction oil at the sensing part of the MZI. To apply the planar type PS-MZI optical waveguide as a biosensor, a detection test for Staphylococcus aureus was conducted according to changes in concentration, having adopted Ti-alkoxide as ligand. The detection result of the S. aureus by the PS-MZI optical waveguide sensor was possible to the level of $10^1$ CFU/ml.

  • PDF

Effect of Partition within Opening on Helium-Air Exchange Flow (개구부에 삽입한 수직평판이 헬륨.공기치환류에 미치는 영향)

  • Tae-il Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.797-805
    • /
    • 2003
  • This paper describes experimental investigations of helium-air exchange flow through single opening and partitioned opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with the opening, for partition ratios H_p/H$_1$$ in the range 0 to 1. where H_p$ and H$_1$ are partition length and height of the opening. respectively. In the case of H_p/H$_1$$ of 0, flow passages of upward flow of the helium and downward flow of the air within the opening are unseparated (bidirectional), and the two flows interfere within the opening. The unseparated flow increases strength of flow resistance and therefore, the exchange flow rate is minimum through range of the partition ratios. Two flow zones, i.e., separated (unidirectional) flow zone and unseparated (bidirectional) flow zone, exist with increasing the partition length. The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at H_p/H$_1$$ of 1. As a result of comparison of the exchange flow rates by changing the partition ratio, the fluids Interference in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

Effect of Opening Partition Length on Helium-Air Exchange Flow (개구부 삽입부의 길이가 헬륨 및 공기의 치환류에 미치는 영향)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.192-200
    • /
    • 1999
  • This paper describes experimental investigations of helium-air exchange flow through parti-tioned opening. Such exchange flow may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with partitioned opening for parti-tion rations $H_p/H_1$ in the range 0 to 1 where $H_p$ and $H_1$ are partition length and height of the open-ing respecticely. In the case of $H_p/H_1$ of 0 flow passages of upward flow of the helium and down-ward flow of the air within the opening are unseparated (bidirectional) and the two flows interact exchange flow rate is minimum through range of the partition ratios, Two flow zones i.e. separat-ed(unidirectional)flow zone and unseparated(bidirectional) flow zone exist with increasing the partition. length, The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at $H_p/H_1$ of 1. As a result fo comparison of the exchange flow rates by changing the partition ration the fluids interaction in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

  • PDF

Development of Wideband Frequency Modulated Laser for High Resolution FMCW LiDAR Sensor (고분해능 FMCW LiDAR 센서 구성을 위한 광대역 주파수변조 레이저 개발)

  • Jong-Pil La;Ji-Eun Choi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1023-1030
    • /
    • 2023
  • FMCW LiDAR system with robust target detection capabilities even under adverse operating conditions such as snow, rain, and fog is addressed in this paper. Our focus is primarily on enhancing the performance of FMCW LiDAR by improving the characteristics of the frequency-modulated laser, which directly influence range resolution, coherence length, and maximum measurement range etc. of LiDAR. We describe the utilization of an unbalanced Mach-Zehnder laser interferometer to measure real-time changes of the lasing frequency and to correct frequency modulation errors through an optical phase-locked loop technique. To extend the coherence length of laser, we employ an extended-cavity laser diode as the laser source and implement a laser interferometer with an photonic integrated circuit for miniaturization of optical system. The developed FMCW LiDAR system exhibits a bandwidth of 10.045GHz and a remarkable distance resolution of 0.84mm.