1MVA 전력용 변압기의 단락특성 해석 (Analysis of Short Circuit Characteristics for 1MVA Power Transformer)

  • 이벽진;안현모;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1109-1110
    • /
    • 2011
  • 본 논문에서는 선간단락 시 단락전류에 의한 전력용 변압기의 단락특성을 해석하였다. 변압기 사양은 1[MVA], 6,600/660[V] 단상 내철형 배전용 변압기를 사용하였으며, 변압기에 유입되는 단락전류를 회로방정식을 이용해 계산하였다. 단락전류에 의해 발생되는 누설자속 밀도는 유한요소법을 이용해 계산하였고, 계산된 단락전류와 누설자속 밀도에 의해 권선에서 발생하는 축 방향과 반경방향 단락전자력을 계산하였다.

  • PDF

다중입력 PSS 튜닝 방법과 612 MVA 화력기 적용: Part 2-현장 튜닝시험 및 성능검증 (Tuning of Dual-input PSS and Its Application to 612 MVA Thermal Plant: Part 2-Field Testing and Performance Verification)

  • 김동준;문영환;김성민;김진이;황봉환;조종만
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.665-670
    • /
    • 2009
  • The second paper, Part 2, describes the field testing of IEEE type PSS2A EX2000 excitation in the Dangjin 612 MVA T/P #4. The final PSS gain, $K_s$, was determined by inputting 2%-step signals into AVR at a loading of 500MW and increasing $K_s$, from 0 to 15 in increments of 3. After the field testing, the measured data was also analyzed by Discrete Fourier Transformation(DFT) analysis, and the model parameters of generation system were verified by replicating the measured data with the transient stability program.

다중입력 PSS 튜닝 방법과 612 MVA 화력기 적용: Part 1-IEEE PSS2A 튜닝 방법 (Tuning of Dual-input PSS and Its Application to 612 MVA Thermal Plant: Part 1-Tuning Methology of IEEE Type PSS2A Model)

  • 김동준;문영환;김성민;김진이;황봉환;조종만
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.655-664
    • /
    • 2009
  • This paper, Part 1, describes the effective dual-input PSS parameter design procedure for the IEEE Type PSS2A against the Dangjin 612 MVA thermal plant's EX2000 excitation system. The suggested tuning technique used the model-based PSS tuning method and consisted of three steps: 1) generation system modeling; 2) determination of PSS2A model parameters using linear, time-domain transient and 3-phase simultaneous analyses, and 3) field testing and verification, which are described in Part 2. The effective PSS2A model parameters of EX2000 system in the Dangjin T/P #4 were designed according to the suggested procedure, and verified by using three analyses.

2[MVA] 배전용 몰드변압기의 과도전계해석에 관한 연구 (A Study on the Transient Analysis of 2[MVA] Mold Transformer for Electric Field)

  • 전문호;김창업
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.171-176
    • /
    • 2010
  • This paper presents the electric field for 22.9[kV]/380[V], 2[MVA] mold transformer are analysed using FEM(finite element method). The electric field was calculated for the voltage applied to the transformer. Then, it is analysed that the maximum electric field occurred between high voltage turns. Capacitance is calculated with energy method. Surge impulse test simulation is studied by modeling circuit with capacitance and inductance. This paper obtain the result that is about influence of electric field in distribution mold transformer adopted.

154 kv/5 MVA 고온 초전도 변압기의 권선구조에 따른 교류손실 (AC Losses of 154 kV/5 MVA HTS Transformer by winding structures)

  • 최지훈;이승욱;김우석;박명진;이지광;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.41-42
    • /
    • 2007
  • 초전도 변압기의 권선에서 발생하는 교류손실은 시스템의 효율과 안정성에 큰 영향을 미친다. 본 논문에서는 고온 초전도 변압기의 권선 구조에 따른 교류손실과 % 임피던스 특성을 살펴보았다. 변압기 철심의 형태가 내철형과 의철형인 경우에 대하여 설계를 하였으며 각 형태에 따른 교류손실과 % 임피던스를 계산하였다. 154 kV/5 MVA 고온 초전도 변압기의 두 가지 철심 형태의 해석을 통해 각각의 특성을 비교하였다.

  • PDF

비선형 부하 이차 고조파 발생 실증사례 분석 및 임피던스 변동 기법을 통한 이차 고조파 저감 기법 (Case Study of Second Harmonic Generation under Nonlinear Load and Second Harmonic Elimination Method Based on Impedance Variation Scheme)

  • 방희균;김시경
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.604-611
    • /
    • 2013
  • This paper presents an second harmonic elimination method based on the impedance variation scheme. Through the power quality analysis from the nonlinear loads connected on the power system, the second harmonic problems have been analyzed with a case study analysis and the experiments. In the paper, the second Harmonic generation was simulated with a single phase SCR rectifier and the analytical model is proposed for the second harmonic generation. A novel impedance variation scheme is proposed and analyzed to eliminate the second harmonic. The experiment has been performed on the 60(MVA) industry manufacturing plant. The experimental result demonstrates the proposed impedance variation scheme successfully operate on the 60(MVA) industry manufacturing plant.

강진 UPFC 운전 실적 (The operation results of Kangjin UPFC)

  • 김수열;전영수;이재욱;박상호;이재청;유현호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.774-777
    • /
    • 2004
  • 한국전력공사에서는 전압원 인버터형 FACTS 기기인 UPFC를 전남 강진군 강진변전소에 설치 (2003. 5. 23준공) 운전하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병렬인버터, 40MVA 직렬인버터로 구성되어 총 80MVA 용량이다. 현재 병렬인버터는 강진 모선전압 제어, 직렬 인버터는 강진-장흥간의 조류제어에 기여하며, 상용운전 중이다. 본 논문에서는 강진 UPFC 준공 1년여를 맞이하여, 그 동안에 발생한 이벤트 및 운전실적을 분석하였다.

  • PDF

UPFC GTO VTE(Valve Test Equipment) 개발 (Development of UPFC GTO Valve Test Equipment)

  • 김수열;장병훈;윤종수;김용학;백두현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.440-442
    • /
    • 2008
  • 한국전력공사는 강진변전소에 FACTS 설비인 80MVA UPFC를 (주)효성과 공동으로 개발하여 2003. 5월 준공하였다. 강진 UPFC는 40MVA 병렬인버터와 40MVA 직렬인버터로 구성되어 있으며, 대용량 인버터 핵심기술은 지멘스와의 기술제휴로 개발되었다. 한국전력공사는 UPFC 운영을 통하여 확보된 기술을 기반으로 제어기술을 국산화하고 있으며, 현재 유지보수용으로 GTO 밸브 시험 장비를 개발하였다. 본 설비는 기존 수작업에 의한 GTO 밸브의 건전성 시험을 자동화하고, 자료를 체계적으로 이력 관리함으로써, UPFC 설비의 신뢰성 향상에 도움을 줄 것으로 기대된다.

  • PDF

3상 90 MVA 단시간전류시험 설비 구축 (The construction of 3-phase 90 MVA short-time withstand current testing facilities)

  • 서윤택;김용식;윤학동;김맹현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.700-702
    • /
    • 2005
  • The most electrical apparatus should be able to withstand short-time current and peak current during a specified short time until circuit breakers have interrupted fault current. It defines the short-time withstand ability of electric a apparatus to be remain for a time interval under high fault current conditions. It is specified by both dynamic ability and thermal capability. KERI(Korea Electrotechlology Research Institute) recently constructed the new short-time current and low voltage short circuit testing facilities. This paper shows short- circuit calculation of transformer and describes high current measuring system, and evaluate the result of short-time withstand test used in $3{\phi}$ 90MVA short-time current testing facilities.

  • PDF

한전계통의 전압안정도 향상 및 과부하 해소를 위한 80MVA UPFC(Unified Power Flow Controller) 설치 (Installation of 80MVA UPFC(Unified Power Flow Controller) for improving voltage stability and reducing heavy load in KEPCO power systems)

  • 오관일;장병훈;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.262-265
    • /
    • 2001
  • 최근 전력계통의 과부하, 전압안정도 등의 문제에 대한 해결책으로 FACTS (Flexible AC Transmission Systems)가 대두되고 있다. FACTS 설비에는 TCSC (Thyristor-Controlled Series Capacitor), SSSC (Static Synchronous Series Capacitor)와 같은 직렬 기기와 SVC(Static Var Compensator), STATCOM(STATic COMpensator) 와 같은 병렬기기 그리고, 본 논문에서 다루는 UPFC와 같은 직 병렬기기로 나누어진다. UPFC는 SSSC와 STATCOM을 결합한 형태로 유 무효전력을 동시에 보상할 수 있는 FACTS 기기이다. 본 논문에서는 한전 계통의 전압안정도 향상과 과부하 해소를 위해 강진S/S에 설치예정인 80MVA UPFC의 하드웨어 특성과 주변계통의 특성을 소개하고, UPFC와 한전 계통의 연계방안과 시험방안을 설명한다.