Design of 1 MVA Single Phase HTS Transformer with Pancake Windings Cooled by Natural Convection of Sub-cooled Liquid Nitrogen

  • Kim, Woo-Seok;Kim, Sung-Hoon;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Lee, Don-Kun;Park, Yeon-Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.34-37
    • /
    • 2003
  • A 1 MVA single-phase high temperature superconducting (HTS) transformer with BSCCO-2223 wire was designed in this paper. The rated voltages of each sides of the transformer are 22.9 kV and 6.6 kV respectively. Double pancake HTS windings arranged reciprocally will be used for the transformer windings, because of the advantages of insulation and distribution of surge voltage in case of a large power and high voltage transformer. Single HTS wire was used for the primary windings and four parallel wires were used for the secondary windings of the transformer with transposition. A core of the transformer was designed as a shell type core separated with the windings by a cryostat made of GFRP with a room temperature bore. The operating temperature of the HTS windings will be about 65K with sub-cooled liquid nitrogen. A cryogenic cooling system using a GM-cryocooler for this HTS transformer by natural convection of liquid nitrogen was designed. This type of cooling system can be a good option for compactness, efficiency, and reliability of the HTS transformer.

Electromagnetic Force Calculation of Internet Winding Fault in A Distribution Power Transformer by using A Numerical Program (수치해석을 이용한 배전용 변압기 권선 고장시의 전자력 계산방법 연구)

  • Shin, Pan-Seok;Ha, Jung-Woo;Chung, Hee-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.60-67
    • /
    • 2007
  • In this paper, a simulation method of the internal winding fault is proposed to calculate winding current and electromagnetic force in a distribution power transformer by suing FEM program. The model of the transformer is a single phase, 60[Hz], 1[MVA], 22.9[kV]/220[V], cable-type winding. The short-circuit current and electromagnetic force are calculated by FEM(Finite Element Method) program(Flux2D) and the results we verified with theoretical formula and PSPICE program. The simulation results are fairly good agreement with the other verified methods within 5[%] error rate. The turn-to-turn short-circuit current is 500 times of the rated current and the electromagnetic force is about $20{\sim}200times$. The method presented in this study may serve as one of the useful tools in the electromagnetic force analysis of the transformer winding behavior under the short circuit condition for design of the structure.

Psychosocial Outcome after Head Injury (두부외상후 심리사회적 예후)

  • Park, Ki-Chang;Kim, Hun-Joo
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.196-202
    • /
    • 2000
  • Objective : This study was designed to evaluate the relationship between the initial neurosurgical or psychosocial factors and the psychosocial outcome. Patients and Methods : We analyzed 123 head-injured patients who were referred to the department of psychiatry for the evaluation of psychosocial function. We analyzed initial neurosurgical variables such as Glasgow Coma scale(GCS) score, skull fracture, CT finding, and psychosocial outcomes with regards to psychosis, personality change, depression, anxiety and IQ on Intelligence Scale. Results : Patients with mild head injury(GCS score 13-15, N=94, 76.4%) had better recovery rate on Glasgow Outcome Scale(GOS), less personality change than those with moderate or severe head injury. However, depression, anxiety and intelligence were not significantly different between two groups. The skull fracture(N=37, 30.1%) did not influence on the psychosocial outcome with reference to personality change, depression, anxiety and intelligence. The patients with abnormal CT findings(N=64, 52%) had lower recovery rate on GOS, more frequent tendency in psychosis, personality change and severe depression, less frequent in anxiety and mild depression, than patients with normal CT finding. However, levels of intelligence were not different between two groups. The patients with industrial accidents(IA) had lower educational level, milder head injury, more delay for the psychiatric evaluation (longer treatment period) than those with motor vehicular accidents(MVA). The psychosocial outcome with reference to personality change, depression, anxiety, intelligence were not different between two groups. Conclusion : These findings indicate that the more severe initial trauma, the poorer psychosocial outcome. However, it was frequently observed that patients with mild head injury suffered from mild anxiety and depression. Therefore mild head injury appeared to be more complicated by psychosocial stressors. The patients with IA, despite the fact that initial head injury was mild, required longer treatment period than MVA.

  • PDF

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

A Tuning Method for the Power System Stabilizer of a Large Thermal Power Plant and Its Application to Real Power System : Part I-Selection of Parameters by Off-line Simulation (대형 화력발전기 전력계통 안정화장치의 정수선정 기법과 실계통 적용 : PART I-오프라인 해석을 통한 PSS 정수 선정)

  • Shin, Jeong-Hoon;Lee, Jae-Gul;Nam, Su-Chul;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.191-200
    • /
    • 2009
  • This paper, which consists of two parts, dealt with the parameter tuning of the power system stabilizer for a 612[MVA] thermal power plant in KEPCO system and its validation in field test. In Part 1 of the paper, the selection of parameters such as lead-lag time constants for phase compensation, system gain was optimized by using linear & eigenvalue analyses and they were verified through the time-domain transient stability analysis. In part 2, the performance of PSS was finally verified by the generator's on-line field test. Through the comparisons of simulation results and measured data before and after tuning of the PSS, the models of generator and its controllers including AVR, Governor and PSS used in the simulation are validated and confirmed.

Incidence and management of mandibular fractures in a low-resource health facility in Ghana

  • Frimpong, Paul;Nguyen, Truc Thi Hoang;Sodnom-Ish, Buyanbileg;Nimatu, Edinam Salia;Dampare, Nana Yaa Asantewaa;Rockson, Roberta;Awuah, Samuel Baffour;Amponsah, Emmanuel Kofi;Newton, Cardinal;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.6
    • /
    • pp.432-437
    • /
    • 2021
  • Objectives: The mandible and other parts of the maxillofacial region suffer significant morbid injuries following road traffic accidents. Our study gives epidemiological description of mandibular fractures in Ghana and also evaluates the relevance of closed reduction and indirect fixation for managing mandibular fractures in low-resource health facilities in low-income countries like Ghana. Patients and Methods: This is a retrospective study involving 268 patients who reported to the Department of Oral and Maxillofacial Surgery of the Sunyani Regional Hospital with mandibular fractures from January 2010 to December 2019. Patient medical records were assessed for information on age, sex, fracture etiology, anatomic location of fracture, time of day of road traffic accident, and other associated injuries. Results: A total of 268 patients were included in this study (males, 216 [80.6%]; females, 52 [19.4%]). Motor vehicular accident (MVA) was the leading cause of mandibular fractures (202 injuries, 75.4%). Other etiologies included assault (39, 14.6%), gunshot (13, 4.9%), falls (12, 4.5%), and industrial accidents (2, 0.7%). Of the 161 male cases caused by MVA, 121 (75.2%) occurred at night and in the evening while the remaining 40 (24.8%) occurred in the morning and afternoon. Among all managed 222 patients, 212 (79.1%) were treated with closed reduction and indirect fixation technique while 10 (3.7%) were treated with open reduction and direct fixation. Conclusion: Closed reduction with indirect fixation could successfully be used to manage mandibular fractures in low resourced health facilities, especially in low-income countries. The poor lightening system on roads in Ghana is a major contributory factor to motor vehicular accidents.

Propulsion Control of Railway Vehicle using Semiconductor Transformer and Switched Reluctance Motor (반도체 변압기 및 스위치드 릴럭턴스 전동기(SRM)를 적용한 철도차량 추진제어)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.127-132
    • /
    • 2022
  • Among the electrical components mounted on railroad cars, the largest load is the main transformer, which has a low power density of 0.2~0.4 MVA/ton due to the low operating frequency(60Hz), which is an important factor for weight reduction. Therefore, research on molded transformers, semiconductor transformers, etc. is being actively conducted at Domestic and foreign in order to improve the main transformer for railway vehicles. Meanwhile, attempts are being made to apply a permanent magnet synchronous motor (PMSM) to replace an induction motor as a traction motor that is mostly applied to domestic and foreign railway vehicles. Permanent magnet synchronous motors (PMSMs) can secure higher power density and efficiency compared to induction motors, but have disadvantages in that the materials required for manufacturing are expensive and design is somewhat difficult compared to induction motors. Considering these problems, in this paper, we suggest that a small and lightweight semiconductor transformer is applied, and a simple structure, high torque, low cost SRM can be applied in accordance with the requirements such as weight reduction and high efficiency of railroad vehicles. content.

Analysis of Power Supply System for 8.5 MVA Magnetic Power Supply Using EI (EMTDC를 이용한 8.5 MVA급 Magnetic Power Supply의 전력공급 시스템 분석)

  • Jeong, Yong-Hoo;Nho, Eui-Cheol;Kim, In-Dong;Choi, Jung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1114-1116
    • /
    • 2002
  • The characteristics of voltage drop and THD for parallel operating 11 PCRs (Phase Controlled Rectifiers) are analysed. The PCRs are used to drive high current (1.6 kA ${\sim}$ 3.7 kADC) electromagnetic coils for electromagnets. All the PCRs operate simultaneously in pulsed mode, and the pulse shot occurs every 150 seconds. During the pulse operation the PCR output current ramps up for 4 seconds, and then keeps flat top state for 2 seconds, and finally ramps down for 4 seconds. For the flat top mode a severe voltage drop and distortion appear in the power system because transformers for the PCRs are designed considering pulsed mode operation. It is expected that the analysis method can be applied to improve the system performance including power factor and design of high power pulsed mode operating power supply systems.

  • PDF

STATCOM research for the efficient operation linked of wind power (풍력 발전시스템의 효율적인 연계운전을 위한 1MVA급 STATCOM 개발)

  • Lee, Chung-Woo;Oh, Seung-Hun;Lee, Yun-Jae;Choi, Eun-Sik;Kang, Byung-Kwan;Ryu, Kang-Yeul;Kim, Hee-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.119-120
    • /
    • 2013
  • Wind turbines as a power distribution system linked to the driving operation according to the characteristics of the distribution system can be adversely affected by a change of circumstances, depending on Distribution Systems with driving characteristics of a wind turbine can be affected. Thus according to the grid-tied wind turbines and transient suppression of the distribution lines and distribution lines outside of the accident in order to maintain stable power supply to supply reactive power efficient system is necessary to keep the voltage constant. In this paper, we substantiated in Jeju Hangwon 12 Unit Level 1MVA STATCOM system configuration, control, configure, and test results will be introduced.