• Title/Summary/Keyword: MTF1

Search Result 207, Processing Time 0.026 seconds

Analysis of Athemalization for F/l.0 Optical System in Long Wavelength Infrared (장파장 적외선영역에서 F/1.0 광학계의 비열화 분석)

  • 김현수;이동한;김현규
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.142-143
    • /
    • 2003
  • 제조기술이 발전함에 따라 회절 복합 렌즈(diffractive hybrid lens)를 사용한 광학계 설계에 대한 많은 연구가 보고 되고 있다. 본 연구에서는 회절 복합 렌즈를 사용한 F/l.0인 광학계를 설계하여 비열화 특성을 분석하였다. 성능조건으로는 MTF가 50% 일 때 사용된 영상센서의 Nyquist 주파수인 11.11cys/mm로 하였다. 사용된 검출기 사양은 픽셀 크기 45um, 픽셀 수 320$\times$240 이며, fill factor 는 무시하였다. 광학계의 유효초점거리는 171.73mm 이다. (중략)

  • PDF

Correction Method of Wiener Spectrum (WS) on Digital Medical Imaging Systems (디지털 의료영상에서 위너스펙트럼(Wiener spectrum)의 보정방법)

  • Kim, Jung-Min;Lee, Ki-Sung;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.17-24
    • /
    • 2009
  • Noise evaluation for an image has been performed by root mean square (RMS) granularity, autocorrelation function (ACF), and Wiener spectrum. RMS granularity stands for standard deviation of photon data and ACF is acquired by integration of 1 D function of distance variation. Fourier transform of ACF results in noise power spectrum which is called Wiener spectrum in image quality evaluation. Wiener spectrum represents noise itself. In addition, along with MTF, it is an important factor to produce detective quantum efficiency (DQE). The proposed evaluation method using Wiener spectrum is expected to contribute to educate the concept of Wiener spectrum in educational organizations, choose the appropriate imaging detectors for clinical applications, and maintain image quality in digital imaging systems.

  • PDF

Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass (칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작)

  • Oh, Seung Eun;Lee, Sun Kyu;Choi, Joong Kyu;Song, Kook Hyun;Baek, Jong Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • In this paper, for low cost infrared optical equipment, we design and fabricate an infrared optical system for an uncooled detector using PGM(Precision Glass Molding) lenses. The designed infrared optical system has a good athermalization, and the material of all of its lenses is a chalcogenide glass suitable for the PGM method. In addition, we also fabricate the same infrared optical system using SPDT(Single Point Diamond Turning) lenses in order to measure the optical performance of PGM lenses. We measure the MTF(Modulation Transfer Function) of the two infrared optical systems which use the PGM lenses and the SPDT lenses. And then we compare and analyze the images of them both. As a result, we find that they have only a very small difference in optical performance. If the use of PGM lenses increases, we expect to reduce the cost of infrared optical equipment.

Retrieval of Spherical Ocean Wave Parameters Using RADARSAT-2 SAR Sensor Observed at Chukk, Micronesia

  • Chaturvedi, Sudhir Kumar;Yang, Chan-Su;Song, Jung-Hwan;Ouchi, Kazuo;Shanmugam, P.
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.213-223
    • /
    • 2011
  • The purpose of this study is to estimate the spherical wave parameters that appears in synthetic aperture radar (SAR) image acquired over the coast of Chukk, Micronesia. The retrieval of ocean wave parameters consists of two main stages: the first is to determine the dominant wavelengths by Fast Fourier Transform (FFT) over 16 sub-image areas and the second is to estimate wave slopes and heights using dispersion relationship under various water wave conditions. It is assumed that the spherical waves are linear and progressive. These type of waves have the range and azimuth components traveling in radial directions. The azimuth travelling waves are more affected by the velocity bunching mechanism and it is difficult to estimate the wave parameters for these affected areas in SAR imagery. In order to compensate these effects, the velocity bunching ratio (VBR) based on modulation transfer function (MTF) was compared with the intensity ratio for neighbor area in the radial direction in order to assign the spherical wave properties for azimuthally travelling waves. Dispersion relation provides the good estimates for the wave heights for all the selected sub-image areas in the range of 1m to 2m. VBR based on MTF was found to be 0.78 at wave height of 1.36m, while the intensity-based VBR was 0.69 which corresponds to the height of 1.75m. It can be said that the velocity bunching accounts for azimuthally travelling spherical waves and the difference results from the sea-bottom effects.

Performance Criterion of Bispectral Speckle Imaging Technique (북스펙트럼 스펙클 영상법의 성능기준)

  • 조두진
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.28-35
    • /
    • 1993
  • In the case of an imaging system affected by aberrations which are not precisely known, the effect of aberrations can be minimized and near-diffraction-limited images can be restored by introducing artificial random phase fluctuations in the exit pupil of the imaging system and using bispectral speckle imaging. In order to determine the optimum value of the correlation length for Gaussian random phase model, computer simulation is performed for 50 image frames of a point object in the presence of defocus, spherical aberration, coma, astigmatism of 1 wave, respectively. In terms of the criterion of performance, the FWHM of the point spread function, normalized peak intensity, MTF and visual inspection of the restored object are employed. The optimum value for the rms difference $\sigma$ of aberration on the exit pupil in the interval of Fried parameter ${\Upsilon}_0$ is given by 0.27-0.53 wave for spherical aberration, and 0.24-0.36 wave for defocus and astigmatism, respectively. It is found that the bispectral speckle imaging technique does not give good results in the case of coma.

  • PDF

Data Compression Capable of Error Control Using Block-sorting and VF Arithmetic Code (블럭정렬과 VF형 산술부호에 의한 오류제어 기능을 갖는 데이터 압축)

  • Lee, Jin-Ho;Cho, Suk-Hee;Park, Ji-Hwan;Kang, Byong-Uk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.5
    • /
    • pp.677-690
    • /
    • 1995
  • In this paper, we propose the high efficiency data compression capable of error control using block-sorting, move to front(MTF) and arithmetic code with variable length in to fixed out. First, the substring with is parsed into length N is shifted one by one symbol. The cyclic shifted rows are sorted in lexicographical order. Second, the MTF technique is applied to get the reference of locality in the sorted substring. Then the preprocessed sequence is coded using VF(variable to fixed) arithmetic code which can be limited the error propagation in one codeword. The key point is how to split the fixed length codeword in proportion to symbol probabilities in VF arithmetic code. We develop the new VF arithmetic coding that split completely the codeword set for arbitrary source alphabet. In addition to, an extended representation for symbol probability is designed by using recursive Gray conversion. The performance of proposed method is compared with other well-known source coding methods with respect to entropy, compression ratio and coding times.

  • PDF

Evaluation of image acquisition using synchrotron radiation in CMOS sensor. (Synchrotron Radiation을 이용한 CMOS sensor image 획득평가)

  • Kim, D.H.;Park, J.K.;Choi, J.Y.;Chang, G.W.;Youn, G.J.;Moon, C.W.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.396-399
    • /
    • 2003
  • In this paper, the purpose is to develop imaging technique of synchrotron radiation using CMOS image sensor. The detector using hybrid method to be research in this lab was used, in order to increase image signal. We made experiments with 1B2 Whitebeam/microprobe beamline in PAL (Pohang Accelerator Laboratory). Phosphor materials such as ZnS:(Ag,Li), ZnS:(Cu,Al), $Y_2O_2S:Eu$ were produced by spin coating on glass. Synchrotron radiation images were acquired and evaluated from monochromatic light from monochromoator in PAL 1B2line. From obtained object and phantom, MTF was 0.15 in ZnS:(Ag,Li) phosphor, and 0.178 in ZnS:( Cu,Al) at 151p/mm. MTFs were unsystematic because thickness of phosphor and uniformity of surface were not optimized. It's expected to improve MTF and the qualify of images as uniformity's optimized.

  • PDF

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Design Anamorphic Lens Thermal Optical System that Focal Length Ratio is 3:1 (초점거리 비가 3:1인 아나모픽 렌즈 열상 광학계 설계)

  • Kim, Se-Jin;Ko, Jung-Hui;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.409-415
    • /
    • 2011
  • Purpose: To design applied anamorphic lens that focal length ratio is 3:1 optical system to improve detecting distance. Methods: We defined a boundary condition as $50^{\circ}{\sim}60^{\circ}$ for viewing angle, horizontal direction 36mm, vertical direction 12 mm for focal length, f-number 4, $15{\mu}m{\times}15{\mu}m$ for pixel size and limit resolution 25% in 33l p/mm. Si, ZnS and ZnSe as a materials were used and 4.8 ${\mu}m$, 4.2 ${\mu}m$, 3.7 ${\mu}m$ as a wavelength were set. optical performance with detection distance, narcissus and athermalization in designed camera were analyzed. Results: F-number 4, y direction 12 mm and x direction 36 mm for focal length of the thermal optical system were satisfied. Total length of the system was 76 mm so that an overall volume of the system was reduced. Astigmatism and spherical aberration was within ${\pm}$0.10 which was less than 2 pixel size. Distortion was within 10% so there was no matter to use as a thermal optical camera. MTF performance for the system was over 25% from 33l p/mm to full field so it was satisfied with the boundary condition. Designed optical system was able to detect up to 2.9 km and reduce a diffused image by decreasing a narcissus value from all surfaces except the 4th surface. From sensitivity analysis, MTF resolution was increased on changing temperature with the 5th lens which was assumed as compensation. Conclusions: Designed optical system which used anamorphic lens was satisfied with boundary condition. an increasing resolution with temperature, longer detecting distance and decreasing of narcissus were verified.