• Title/Summary/Keyword: MTA1

Search Result 126, Processing Time 0.022 seconds

Effects of different calcium-silicate based materials on fracture resistance of immature permanent teeth with replacement root resorption and osteoclastogenesis

  • Gabriela Leite de Souza;Gabrielle Alves Nunes Freitas;Maria Tereza Hordones Ribeiro;Nelly Xiomara Alvarado Lemus;Carlos Jose Soares;Camilla Christian Gomes Moura
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.21.1-21.15
    • /
    • 2023
  • Objectives: This study evaluated the effects of Biodentine (BD), Bio-C Repair (BCR), and mineral trioxide aggregate (MTA) plug on the fracture resistance of simulated immature teeth with replacement root resorption (RRR) and in vitro-induced osteoclastogenesis. Materials and Methods: Sixty bovine incisors simulating immature teeth and RRR were divided into 5 groups: BD and BCR groups, with samples completely filled with the respective materials; MTA group, which utilized a 3-mm apical MTA plug; RRR group, which received no root canal filling; and normal periodontal ligament (PL) group, which had no RRR and no root canal filling. All the teeth underwent cycling loading, and compression strength testing was performed using a universal testing machine. RAW 264.7 macrophages were treated with 1:16 extracts of BD, BCR, and MTA containing receptor activator of nuclear factor-kappa B ligand (RANKL) for 5 days. RANKL-induced osteoclast differentiation was assessed by staining with tartrate-resistant acid phosphatase. The fracture load and osteoclast number were analyzed using 1-way ANOVA and Tukey's test (α = 0.05). Results: No significant difference in fracture resistance was observed among the groups (p > 0.05). All materials similarly inhibited osteoclastogenesis (p > 0.05), except for BCR, which led to a lower percentage of osteoclasts than did MTA (p < 0.0001). Conclusions: The treatment options for non-vital immature teeth with RRR did not strengthen the teeth and promoted a similar resistance to fractures in all cases. BD, MTA, and BCR showed inhibitory effects on osteoclast differentiation, with BCR yielding improved results compared to the other materials.

Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth

  • Maria Aparecida Barbosa de Sa;Eduardo Nunes ;Alberto Nogueira da Gama Antunes ;Manoel Brito Junior ;Martinho Campolina Rebello Horta ;Rodrigo Rodrigues Amaral;Stephen Cohen ;Frank Ferreira Silveira
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.53.1-53.11
    • /
    • 2021
  • Objectives: This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. Materials and Methods: A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. Results: The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). Conclusions: The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.

GENE EXPRESSION PROFILING IN HUMAN DENTAL PULP CELLS TREATED WITH MINERAL TRIOXIDE AGGREGATE (Mineral trioxide aggregate가 인간치수세포에서 유전자 발현에 미치는 영향)

  • Kim, Yong-Beom;Shon, Won-Jun;Lee, Woo-Cheol;Kum, Kee-Yeon;Baek, Seung-Ho;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.152-163
    • /
    • 2010
  • This study investigated the changes in gene expression when mineral trioxide aggregate (MTA) was applied in vitro to human dental pulp cells (HDPCs). MTA in a teflon tube (diameter 10 mm, height 2 mm) was applied to HDPCs. Empty tube-applied HDPCs were used as negative control. For microarray analysis, total RNA was extracted at 6, 24, and 72 hrs after MTA application. The results were confirmed selectively by performing reverse transcriptase polymerase chain reaction for genes that showed changes of more than two-fold or less than half. Of the 24,546 genes, 109 genes were up-regulated greater than twofold (e.g., FOSB, THBS1, BHLHB2, EDN1, IL11, FN1, COL10A1, and TUFT1) and 69 genes were down-regulated below 50% (e.g., SMAD6 and DCN). These results suggest that MTA, rather than being a bio-inert material, may have potential to affect the proliferation and differentiation of pulp cells in various ways.

SPECTROPHOTOMETRIC EVALUATION OF SEALING EFFECTS OF SEVERAL ROOT-END FILLING MATERIALS (분광광도법을 사용한 수종 역충전재의 근단부 폐쇄효과에 관한 연구)

  • Yi, Jin-Gyu;Park, Sang-Jin;Choi, Kyung-Kyu;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.449-456
    • /
    • 2003
  • The purpose of this study is to evaluate the sealing effect of several root-end filling materials using spectrophotometric analysis. 180 single root teeth with one canal were instrumented and canal filled. Root resected and root end preparation was made. Teeth were randomly classified to S experimental group(MTA, EBA, IRM, TCP, ZOE) and 1 control group according to root-end filling material MTA group used PRO ROOT MT A, EBA group used Super EBA. TCP group used NEW APATITE LINER TYPE II main component of which is ${\alpha}-tricalcium$ phosphate (TCP). According to manufacture's instruction experimental material was mixed and retrfilled. After 2% methylene blue solution penetration absorbance for each test sample was measured with spectrophotometer (JASCO UV-530, Japan). The mean absorbance of control and experimental group was as follows; MTA: 0.092, IRM: 0.226, Super EBA: 0.255, ZOE: 0.374, Control: 0.425, TCP: 0.501 and the result analyzed by Turkey test at P=0.05 level. Conclusions of this study are as follows; 1. The absorbance increase in following sequence MTA, IRM, Super EBA, ZOE, Control. TCP. 2. MTA showed the least leakage but was not significant with IRM or Super EBA and was significant with control or TCP(p<0.05). 3. TCP had the most leakage and was not significant with control group.

A COMPARISON STUDY OF ENDODONTIC FURCATION PERFORATION REPAIR WITH SUPER EBA, KETAC SILVER, MTA AND EMDOGAIN USING SURGICAL MICROSCOPE IN ADULT DOGS (성견에서 Super EBA, Ketac Silver, MTA와 Emdogain을 이용한 치근분지부 전공치유에 관한 연구)

  • Baek, Seung-Ho;Son, Ho-Hyun;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.159-169
    • /
    • 2000
  • The purpose of this study was to examine the tissue response to experimental furcation perforations immediately treated with Super EBA, Ketac Silver, MTA and Emdogain using surgical microscope. Forty experimental furcation perforations were created in the mandibular and maxillary premolars and molars of 4 adult dogs and immediately repaired with experimental materials. The animals were sacrificed after 16 weeks and radiographic and histologic results were evaluated. The results were as follows. 1 All materials tested in this experiment revealed a certain degree of extrusion of the filling materials and infiltration of inflammatory cells into the periodontal space. Except MTA group, epithelial down-growth of the surrounding gingiva was found in all experimental groups. 2. Both Ketac Silver and Emdogain group showed the greatest degree of inflammatory reaction and bone resorption. 3. Super EBA group showed moderate inflammation and newly bone formation under the perforation area. 4. MTA group showed minor inflammation, new bone regeneration toward restorative materials and partially cementum growth onto the surface of the material. This group demonstrated a favorable prognosis.

  • PDF

Biological assessment of a new ready-to-use hydraulic sealer

  • Francine Benetti ;Joao Eduardo Gomes-Filho ;India Olinta de Azevedo-Queiroz;Marina Carminatti;Leticia Citelli Conti;Alexandre Henrique dos Reis-Prado ;Sandra Helena Penha de Oliveira ;Edilson Ervolino ;Eloi Dezan-Junior ;Luciano Tavares Angelo Cintra
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.21.1-21.12
    • /
    • 2021
  • Objectives: This study compared the cytotoxicity, biocompatibility, and tenascin immunolabeling of a new ready-to-use hydraulic sealer (Bio-C Sealer) with MTA-Fillapex and white MTA-Angelus. Materials and Methods: L929 fibroblasts were cultivated and exposed to undiluted and diluted material extracts. Polyethylene tubes with or without (the control) the materials were implanted into the dorsa of rats. At 7 days and 30 days, the rats were euthanized, and the specimens were prepared for analysis; inflammation and immunolabeling were measured, and statistical analysis was performed (p < 0.05). Results: MTA-Fillapex exhibited greater cytotoxicity than the other materials at all time points (p < 0.05). The undiluted Bio-C Sealer exhibited greater cytocompatibility at 6 and 48 hours than white MTA-Angelus, with higher cell viability than in the control (p < 0.05). White MTA-Angelus displayed higher cell viability than the control at 24 hours, and the one-half dilution displayed similar results at both 6 and 48 hours (p < 0.05). At 7 days and 30 days, the groups exhibited moderate inflammation with thick fibrous capsules and mild inflammation with thin fibrous capsules, respectively (p > 0.05). At 7 days, moderate to strong immunolabeling was observed (p > 0.05). After 30 days, the control and MTA-Fillapex groups exhibited strong immunolabeling, the white MTA-Angelus group exhibited moderate immunolabeling (p > 0.05), and the Bio-C Sealer group exhibited low-to-moderate immunolabeling, differing significantly from the control (p < 0.05). Conclusions: Bio-C Sealer and white MTA-Angelus exhibited greater cytocompatibility than MTA-Fillapex; all materials displayed adequate biocompatibility and induced tenascin immunolabeling.

Comparative analysis of bond strength to root dentin and compression of bioceramic cements used in regenerative endodontic procedures

  • Maykely Naara Morais Rodrigues;Kely Firmino Bruno;Ana Helena Goncalves de Alencar;Julyana Dumas Santos Silva;Patricia Correia de Siqueira;Daniel de Almeida Decurcio;Carlos Estrela
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.59.1-59.14
    • /
    • 2021
  • Objectives: This study compared the Biodentine, MTA Repair HP, and Bio-C Repair bioceramics in terms of bond strength to dentin, failure mode, and compression. Materials and Methods: Fifty-four slices obtained from the cervical third of 18 single-rooted human mandibular premolars were randomly distributed (n = 18). After insertion of the bioceramic materials, the push-out test was performed. The failure mode was analyzed using stereomicroscopy. Another set of cylindrically-shaped bioceramic samples (n = 10) was prepared for compressive strength testing. The normality of data distribution was analyzed using the Shapiro-Wilk test. The Kruskal-Wallis and Friedman tests were used for the push-out test data, while compressive strength was analyzed with analysis of variance and the Tukey test, considering a significance level of 0.05. Results: Biodentine presented a higher median bond strength value (14.79 MPa) than MTA Repair HP (8.84 MPa) and Bio-C Repair (3.48 MPa), with a significant difference only between Biodentine and Bio-C Repair. In the Biodentine group, the most frequent failure mode was mixed (61%), while in the MTA Repair HP and Bio-C Repair groups, it was adhesive (94% and 72%, respectively). Biodentine showed greater resistance to compression (29.59 ± 8.47 MPa) than MTA Repair HP (18.68 ± 7.40 MPa) and Bio-C Repair (19.96 ± 3.96 MPa) (p < 0.05). Conclusions: Biodentine showed greater compressive strength than MTA Repair HP and Bio-C Repair, and greater bond strength than Bio-C Repair. The most frequent failure mode of Biodentine was mixed, while that of MTA Repair HP and Bio-C Repair was adhesive.

Metatitanic Acid를 광전극으로 적용한 페로브스카이트 태양전지

  • Pyo, Se-Yeong;Jeong, Seung-Gyu;Sin, Hyeon-Ho;Jeong, Hyeon-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.471.1-471.1
    • /
    • 2014
  • 염료감응형 태양전지(DSSC)는 다양한 태양전지 중, 가장 환경친화적이고, 생산단가도 낮을 뿐만 아니라 다양한 색상과 투광성을 확보할 수 있어 많은 연구가 진행되어왔다. 하지만 액체전해질을 사용하는 기존 염료감응형 태양전지는 높은 휘발성과 열 팽창 수축에 따른 전해질 누액의 문제점으로 인하여 최근에는 고체전해질을 이용한 염료감응형 태양전지의 개발이 활발히 이루어지고 있다. 또한 기존 염료보다 높은 흡광계수와 넓은 흡수스펙트럼을 지닌 페로브스카이트가 개발되어 현재 많은 관심이 주목되고 있다. 본 연구에서는 $TiO_2$ 제조상의 중간생성물인 Metatitanic acid (MTA)를 이용하여 광전극을 형성하고 열처리 온도에 따른 나노입자의 소성거동평가을 평가하였고 시차열중량 분석, 결정상 확인을 하고 염료감응 태양전지에 적용하였다. MTA 나노입자를 Field Emission Transmission Electron Microscopy (FE-TEM), Barrett-Joyner-Halenda (BJH pore size distribution)과 Brunauer-Emmet-Teller (BET) 분석을 통해 소성거동을 평가하고, Thermogravimetry and differential thermal analysis (TG-DTA)를 통해 열중량 측정을 하였으며, X-ray Diffraction (XRD) 분석을 통해 결정상을 확인하였다. 또한 Fourier-transform infrared (FT-IR) spectroscopy를 통해 MTA 나노입자의 표면분석을 하였다. 형성된 MTA 광전극을 페로브스카이트 염료에 적용하여 5%의 효율을 달성하였다.

  • PDF

A micro-computed tomography evaluation of voids using calcium silicate-based materials in teeth with simulated internal root resorption

  • Tek, Vildan;Turker, Sevinc Aktemur
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.1
    • /
    • pp.5.1-5.8
    • /
    • 2020
  • Objectives: The obturation quality of MTA, Biodentine, Total Fill BC root canal sealer (RCS), and warm gutta-percha (WGP) in teeth with simulated internal root resorption (IRR) was evaluated by using micro-computed tomography. Materials and Methods: Standardized IRR cavities were created using 40 extracted maxillary central incisor teeth and randomly assigned into 4 groups (n = 10). IRR cavities were filled with MTA, Biodentine, Total Fill BC RCS (bulk-fill form) and WGP + Total Fill BC RCS. Percentage of voids between resorptive cavity walls and obturation material (external void), and inside the filling materials (internal voids) were measured. Results: Total Fill BC sealer in the bulk-fill form presented significantly highest values of external and internal void percentages (p < 0.05). Biodentine showed a significantly lowest external void percentage (p < 0.05). WGP + Total Fill BC RCS presented significantly lower values of internal void percentages than all groups (p < 0.05), except Biodentine (p > 0.05). Conclusion: None of the filling materials were created void-free obturation in resorption cavities. Biodentine may favor its application in teeth with IRR over Angelus MTA and bulkfill form of Total Fill BC.

Physical properties of novel composite using Portland cement for retro-filling material (치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰)

  • Lee, Sang-Jin;Cho, Ok-In;Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.445-452
    • /
    • 2010
  • Objectives: The aim of this study was to compare apical sealing ability and physical properties of MTA, MTA - AH-plus mixture (AMTA) and experimental Portland cement - Epoxy resin mixture (EPPC) for a development of a novel retro-filling material. Materials and Methods: Forty-nine extracted roots were instrumented and filled with gutta-percha. Apical root was resected at 3 mm and the retro-filling cavity was prepared for 3 mm depth. Roots were randomly divided into 3 groups of 15 roots each. The retro-filling was done using MTA, AMTA, and EPPC as the groups divided. Four roots were used as control groups. After setting in humid condition for 24 hours, the roots were immersed in 1% methylene blue dye solution for 72 hours to test the apical leakage. After immersion, the roots were vertically sectioned and photos were taken to evaluate microleakage. Setting times were measured with Vicat apparatus and digital radiographs were taken to evaluate aluminum equivalent thickness using aluminum step wedge. The results of microleakage and setting time were compared between groups using one-way ANOVA and Scheffe's post-hoc comparison at the significance level of 95%. Results: AMTA and EPPC showed less microleakage than MTA group (p < 0.05). AMTA showed the highest radio-opacity than other groups and the novel EPPC showed 5 mm aluminum thickness radio-opacity. EPPC showed the shortest initial and final setting times than other groups while the MTA showed the longest (p < 0.05). Conclusions: Under the condition of this study, the novel composite using Portland cement-Epoxy resin mixture may useful for retro-filling with the properties of favorable leakage resistance, radio-opacity and short setting time.