• Title/Summary/Keyword: MSW RDF

Search Result 13, Processing Time 0.028 seconds

The Effect of the MSW-RDF Power Generation and Tipping Fee Sharing in RDF Project (RDF발전효과와 사업비 분담방안)

  • Choe, Gap-Seok;Choe, Yeon-Seok;Kim, Seok-Jun;Gwon, Yeong-Bae
    • 연구논문집
    • /
    • s.32
    • /
    • pp.5-13
    • /
    • 2002
  • This paper deals with the result of an analysis on the effect of the power generation by municipal solid waste(MSW)-refuse derived fuel(RDF) and the introduction of tipping fee sharing between RDF manufacturing and power generation project. As a model case for the MSW generated at small and medium cities in our country, an analysis of the RDF power generation and Tipping fee sharing shows that 1) MSW amount of 7,800* $10^3 $t/y could produce 1,950*$10^3$t/y of RDF 2) Electric power generated by MSW-RDF could supply 290,000 households/year and 98,548 C-t/y of $CO_2$ could be reduced. 3) Tipping Fee should be shared by the considering of the contents of project of both side between RDF Production and power generation.

  • PDF

An Economic Evaluation of MSW RDF Production Plant (생활폐기물 고형연료(RDF) 제조기술 경제성 평가)

  • Choi, Yeon-Seok;Choi, Hang-Seok;Kim, Seock-Joon
    • New & Renewable Energy
    • /
    • v.7 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • The waste treatment fee and energy production effect of Wonju city RDF plant, the first RDF manufacturing plant in Korea, were investigated in the study. All plant operation data, like total weight of received wastes, produced RDF and separated rejects in processes were fully recorded for mass balance calculation of the plant in 2009. Also all consumed oil and electricity were recorded for energy balance calculation. The results showed that the waste treatment fee not including the RDF sales price of 25,000 won/ton-RDF was 116,573 won/ton-MSW and it went down to 105,298 won when included the RDF price. Produced RDF was 40.2% of total received waste in weight. Three components analysis by mass balance calculation of total received waste showed that Wonju city's MSW was 32.4% of combustible, 37.5% of water and 30.1% of incombustible respectively. Energy effect was found that total amount of produced energy was about 4 times more than that of consumed energy.

RDF(Refuse Derived Fuel) Generation using MSW(Municipal Solid Waste) (생활폐기물을 이용한 RDF(Refuse Derived Fuel) 발전)

  • Jang, Jik-Sun;Jo, Jae-Beom
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.448-451
    • /
    • 2008
  • For resource Recycle society, the Ministry of Environment is recently propeling the introduction of MSW(Municipal Solid Waste) pretreatment facilities(MBT) from advanced country such as Germany. On the basis of this, The Ministry of Environment plans to expand all over the country after the adaption of wide area style(Sudokwon landfill : 200 ton/day), urban communities style(Bucheon City : 90 ton/day), Semi-urban(Gangreung City : 150 tons/a day), farm village style (Buan : 30 ton/day).

  • PDF

An Evaluation on the Effect of the MSW-RDF Power Generation on the Thermal Efficiency and $CO_2$ Reduction (RDF발전에 의한 열효율향상 및 $CO_2$삭감효과에 대한 평가)

  • Choe, Gap-Seok;Choe, Yeon-Seok;Kim, Seok-Jun;Gwon, Yeong-Bae
    • 연구논문집
    • /
    • s.31
    • /
    • pp.45-51
    • /
    • 2001
  • One of emerging technologies under development in the advanced countries is considered as RDF(Refuse Derived Fuel) power generation, which could meet both the requirement of an alternative energy resource utilization and $CO_2$ reduction. This paper deals with the effect to the thermal effiency and CO2 reduction of RDF firing power generation. The statistical data of domestic MSW generation in last year in small and medium cities for evaluating the merits of the RDF power generation were used. The analysis for RDF power generation compared to the existing incinerator w/o(or w/) power generation shows around 20.6%(10.0%) up in the total thermal efficiency and 57.0%(31.4%) up in the $CO_2$ reduction respectively.

  • PDF

An Economic Evaluation of MSW RDF production plant (생활폐기물고형연료(RDF) 제조기술 경제성 평가)

  • Choi, Yeonseok;Choi, Hangseok;Kim, Seockjoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.158.1-158.1
    • /
    • 2010
  • 국내 최초의 생활폐기물고형연료(RDF) 생산플랜트인 원주시 RDF플랜트의 2009년도 운영실적을 정리하여 폐기물 처리단가를 분석하였으며 에너지 생산 효과도 분석하였다. 실적분석에 사용된 자료는 원주 RDF플랜트 위탁운영업체가 운영비를 청구 및 정산하기 위해서 원주시에 상시 측정 및 보고하는 항목으로서, 내용은 트럭으로 플랜트에 반입되는 폐기물 전체량, RDF생산 전체량, 불순물 매립 전체량, 건조 및 탈취용 연료사용 전체량, 전기사용 전체량 등이다. 2009년도 원주시 RDF플랜트에 반입된 폐기물 량은 총 17,504톤이었고, RDF를 총 7,044톤 생산하였으며, 4,120톤의 불연물을 선별하였다. 1년간 사용한 건조 및 탈취용 연료는 총 596,268 리터였으며 연료인 부생유의 가격은 리터 당 평균 864.6원이었다. 사용한 전기량은 총 2,435,397 kWh였고, 이 중에서 성형공정에 사용된 전기량은 총 사용량의 19%였다. 이상의 기록자료들을 분석해 본 결과, 폐기물 1톤을 처리하는데 전기 비용이 14,334원이었고, 연료비가 29,452원이었다. 여기에 폐기물 1톤당 불연물 매립비 6,573원과 위탁인건비를 합하면 폐기물 1톤당 처리비용은 약 116,573원으로 나타났다. 현재 원주시 RDF는 톤당 25,000원에 판매되고 있으므로 이 비용을 감안하면 폐기물 1톤당 처리비용은 105,298원으로 산출되었다. 현재 알려진 유사 규모의 소각로 운영비가 폐기물 1톤당 136,736원인데, 이것은 RDF기술보다 31,438원/톤-폐기물 정도 처리비용이 비싸다. 따라서 100톤 이하 규모의 폐기물처리시설 설치를 할 경우에는 RDF 시설이 경제적으로 타당함을 나타낸다. 원주시 RDF플랜트의 물질수지를 분석해 본 결과, RDF생산 수율은 40.2%였으며 총 투입된 에너지는 8,0587 Gcal였다. 생산된 에너지 총량은 RDF발열량 4,500 kcal/kg으로 했을 때 31,699 Gcal로 나타났다. 투입대비 생산에너지 비율은 25.4%로 계산되었고, 전기의 발전효율을 40%로 감안했을 경우에는 35.3%로 계산되었다. 성형하는데 사용되는 총 에너지는 전체 투입에너지의 4.9%로 나타났고, 비용으로는 폐기물 1톤당 2,723원 이었다.

  • PDF

Quality Assessment by MSW Type for High-quality and Low-pollution RDF (고품질·저오염 RDF 생산을 위한 생활폐기물 성분평가)

  • Ham, Kwang-Joon;Oh, Geun-Chan;Park, Young-Han;Kim, Min-Su;Kim, Joon-Hyun
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.453-460
    • /
    • 2009
  • In order to provide fundamental data for developing high-grade(high-quality and low-pollution) Refuse Derived Fuel(RDF), we analyzed caloric value and HCl content by Municipal Solid Waste(MSW) type. The caloric value was analyzed using calorimeter and HCl content was analyzed using mercury(II) thiocyanate method. In case of paper type the caloric value was 3,060~3,608kcal/kg and the HCl content was 239~6,135ppm. In case of vinyl-plastics the caloric value was 5,946~9,888kcal/kg and the HCl content was 429~455,771ppm. According to the result of quality assessment by MSW type, the calroric value of vinyl-plastics type was showed higher than that of paper type and in case of HCl content the paper type was showed lower than vinyl-plastics type. So, We mixed paper and plastic wastes. The caloric value of mixed MSW(paper and plastics) was 5,046~9,125kcal/kg and the HCl content was 239~6,135ppm. Also, The caloric value of packaging waste(film-plastics) was 5,982~8,045kcal/kg. Therefore It is possible to develop high-grade Refuse Derived Fuel through suitable mixing of paper and plastic in municipal solid waste.

RDF Processing Equipment and Optimal Design of RDF Plants using RFTF method and Costs assessment (폐기물 전처리 공정 및 RFTF 법을 이용한 최적 공정 설계와 경제성 평가)

  • Lee, Sung-Joo;Cho, Hee-Chan;Ahn, Ji-Whan;Yoo, Kwang-Suk
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.05a
    • /
    • pp.103-108
    • /
    • 2005
  • 최근에 도시생활폐기물(MSW) 관리는 처리 기술에 관한 것뿐만 아니라 재활용 기술에서도 관심이 되고 있다. 그러므로 RDF(Refuse Derived Fuel)는 에너지 재활용 기술 부문에서 더욱더 중요성이 강조되고 있다. 본 연구에서는 RDF의 생산공정-전처리 과정의 기술적인 평가를 수행하였다. RFTF법을 이용하여 높은 발열량의 질 좋은 RDF를 생산하기 위한 최적 생산라인을 설계하는 시도를 하였다. 다양한 RDF 생산라인의 효율을 비교하기 위하여 컴퓨터 모델인 RFTF법을 이용하였는데 이 모델은 Diaz et al에 의하여 개발된 모델로서 RFTF(Recovery Factor Transfer Function)에 따른 물질수지의 계산을 하기 위하여 개발되었다. 결과적으로 년 연구를 통하여 최적의 RDF 전처리 공정라인을 추정할 수 있었고 경제성 평가를 수행하여 경제적인 공정라인을 제시하였다.

  • PDF

폐기물 연소 보일러의 튜브 손상 메카니즘

  • Baek, Se-Hyeon
    • 열병합발전
    • /
    • s.68
    • /
    • pp.9-13
    • /
    • 2009
  • 최근 국내에 MSW(Municipal Solid Waste), RDF(Refuse-Derived Fuel) 또는 석탄과 폐기물을 혼합 연소하는 Waste-To-Energy 보일러 대한 관심이 증대되고 있는바, EPRI(Electric Power Research Institute)의 연구자료를 인용하여 상기 보일러에 대한 튜브 손상 메카니즘에 대하여 설명하고자 한다.

  • PDF

The study of the Composition and Physico-chemcal Characteristics of MSW in urban and gangwon area (수도권 및 강원지역 도시고형폐기물의 조성과 물리·화학적 특성연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.3
    • /
    • pp.65-74
    • /
    • 2008
  • In this study, the composition and physico-chemical characteristics of municipal solid waste (MWS) which was treated in four different area were investigated. It is necessary to measure the characteristics of MSW to build a waste treatment and Refuse Derived Fuel (RDF) facility, the data-base and total managing of the landfill. It was found that the average density of solid wastes is in the range of $78.15-199.8kg/m^3$. This MSW was composed of 8.87% of food wastes, 38.8% of papers, 34.12% of plastics & vinyls, 7.16% of textiles, 0.96% of wood, 1.3% of rubber & leathers and others, respectively. Most of MSW are composed of food, paper and plastic waste and more than 94% was combustible waste. For three components, moisture is 17.38%, combustible component is 69.03% and ash is 6.24%. The chemical element has the high order of carbon, oxygen, hydrogen on the dry basis of wastes. And the low heating value of the MSW which is measured by calorimeter is calculated as 2973.8 kcal/kg and high heating value of the MSW is calculated as 5209.94 kcal/kg.

  • PDF

The Study of Physico-chemcal Characteristics of Municipal Solid Waste (MSW) in Gangwon Area (강원지역 도시폐기물의 물리·화학적 특성 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.2
    • /
    • pp.101-111
    • /
    • 2009
  • In this study, the physico-chemical characteristics of municipal solid waste (MWS) which was treated in gangwon area were investigated. It is necessary to measure the characteristics of municipal solid waste for build a waste treatment and RDF facility and for data-base and total managing of the landfill. It was found that the average density of solid wastes is in the range of $101.8{\sim}199.8kg/m^3$. This MSW was composed of 30.7% of food wastes, 36.3% of papers, 15.8% of plastics & vinyls, 1.9% of textiles, 3.2% of wood and 1.5% of rubber & leathers respectively. Most of MSW are composed of food, paper and plastic waste and the combustible waste is more than 90%. For three components, moisture is 44.6%, combustible component is 47.7% and ash is 7.7% respectively. The chemical elements are carbon, oxygen, and hydrogen on the dry basis of wastes. The low heating value of the MSW measured by calorimeter was obtained as 2,631 kcal/kg, and the high heating value of the MSW was obtained as 3,310 kcal/kg.

  • PDF