• Title/Summary/Keyword: MS scheme

Search Result 163, Processing Time 0.025 seconds

Improved TOA-Based Localization Method with BS Selection Scheme for Wireless Sensor Networks

  • Go, Seungryeol;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.37 no.4
    • /
    • pp.707-716
    • /
    • 2015
  • The purpose of a localization system is to estimate the coordinates of the geographic location of a mobile device. The accuracy of wireless localization is influenced by nonline-of-sight (NLOS) errors in wireless sensor networks. In this paper, we present an improved time of arrival (TOA)-based localization method for wireless sensor networks. TOA-based localization estimates the geographic location of a mobile device using the distances between a mobile station (MS) and three or more base stations (BSs). However, each of the NLOS errors along a distance measured from an MS (device) to a BS (device) is different because of dissimilar obstacles in the direct signal path between the two devices. To accurately estimate the geographic location of a mobile device in TOA-based localization, we propose an optimized localization method with a BS selection scheme that selects three measured distances that contain a relatively small number of NLOS errors, in this paper. Performance evaluations are presented, and the experimental results are validated through comparisons of various localization methods with the proposed method.

Blind Channel Estimation based on Hadamard Matrix Interstream Transmission for Multi-Cell MIMO Networks (다중 셀 MIMO 네트워크를 위한 Hadamard 행렬 Interstream 전송 기반 Blind 채널 추정)

  • Yang, Jae-Seung;Hanif, Mohammad Abu;Park, Ju-Yong;Lee, Moon-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.119-125
    • /
    • 2015
  • In this paper, we introduce a Hadamard matrix interstream transmission based blind channel estimation for multi-cells multiple-input and multiple-output (MIMO) networks. The proposed scheme is based on a network with mobile stations (MS) which are deployed with multi cells. We assume that the MS have the signals from both cells. The signal from near cell are considered as desired signal and the signals from the other cells are interference signal. Since the channel is blind, so that we transmit Hadamard matrix pattern pilot stream to estimate the channel; that gives easier and fast channel estimation for large scale MIMO channel. The computation of Hadamard based system takes only complex additions, and thus the complexity of which is much lower than the scheme with Fourier transform since complex multiplications are not needed. The numerical analysis will give perfection of proposed channel estimation.

QoS-based Optimal Timeslot Allocation for MF-TDMA Broadband Satellite Systems (MF-TDMA 광대역 위성시스템을 위한 QoS 기반 최적 타임슬롯 할당 체계)

  • Chang Kun-Nyeong;Lee Ki-Dong;Park You-Jin
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.29 no.4
    • /
    • pp.141-157
    • /
    • 2004
  • In this paper, we consider broadband satellite systems using MF-TDMA(Multi-Frequency Time Division Multiple Access) scheme. First, we analyze return link, superframe structure, and QoS( Quality of Service) parameters in broadband satellite systems, and mathematically formulate the QoS-based optimal timeslot allocation problem as a nonlinear integer programming problem for broadband satellite systems with clear-sky and rain-fade satellite terminals, and multiple data classes. Next, we modify the proposed problem to solve it within in a fast time, and suggest the QoS-based optimal timeslot allocation scheme. Extensive simulation results show that the proposed scheme finds an optimal solution or a near optimal solution within 5ms at Pentium IV PC.

Performance Improvement of AODV Routing Algorithm Using Timestamp (Timestamp를 이용한 AODV 라우팅 알고리즘의 성능 개선)

  • Lee Jae-Suk;Park Hae-Ryeon;Lee Kee-Hyun;Suk Jung-Bong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.8A
    • /
    • pp.830-836
    • /
    • 2006
  • One of the seminal operation parameters of AODV is the node-to-node travel time of data, which is currently set to fixed value of 40 ms in the RFC3561 and widely used to compute other parameters such as the expected round-trip time of the connection setup message, etc. We have naturally thought the network performance could be improved by dynamically varying the node-to-node travel time with respect to the traffic condition in the networt rather than using the fixed value, which motivates this work. To this end, we apply the idea of using timestamp; every node places the current time in the message before sending it out, and the receiver node computes the node travel time based on the moving average algorithm by considering not only the current value but also the previous ones in an accumulated and exponentially decreasing fashion with time. We evaluate the performance of the proposed scheme in respect of the number of RREQ messages generated, throughput, and delay as a function of traffic load and node mobility, and compare the result with the original AODV scheme. The results show that the proposed scheme presents noticeable performance improvements, expecially under the condition of high node mobility and high traffic load.

A Seamless Voice Call Handover Scheme for the 3G LTE System (3G LTE 시스템을 위한 끊김없는 음성 호 핸드오버 방법)

  • Kim, Kyung-Min;Jung, Hyun-Duk;Lee, Jai-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2A
    • /
    • pp.174-185
    • /
    • 2010
  • A seamless handover between the 3G LTE and legacy 3G system is required for the smooth deployment of the 3G LTE system which is the next generation cellular network system. Especially on voice call handover, the service interruption time is very sensitive for user's satisfaction and therefore, a seamless voice call handover scheme is necessarily required. However, handover between the 3G LTE and the 3G CS system is hard to be achieved due to the lack of interface between two systems and the restriction of radio resource. In this paper, a new network entity called SCSE is proposed and inter-working between the 3G LTE and the 3G CS systems is enabled. Also contributed to the feature of the SCSE, the handover procedure is simplified and the service interruption time is minimized as a consequence. The evaluation result shows that the proposed SCSE scheme exclusively meets the service interruption time requirement which is smaller than 300 ms.

A 12b 100MS/s 1V 24mW 0.13um CMOS ADC for Low-Power Mobile Applications (저전력 모바일 응용을 위한 12비트 100MS/s 1V 24mW 0.13um CMOS A/D 변환기)

  • Park, Seung-Jae;Koo, Byeong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.56-63
    • /
    • 2010
  • This work proposes a 12b 100MS/s 0.13um CMOS pipeline ADC for battery-powered mobile video applications such as DVB-Handheld (DVB-H), DVB-Terrestrial (DVB-T), Satellite DMB (SDMB), and Terrestrial DMB (TDMB) requiring high resolution, low power, and small size at high speed. The proposed ADC employs a three-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. A single shared and switched op-amp for two MDACs removes a memory effect and a switching time delay, resulting in a fast signal settling. A two-step reference selection scheme for the last-stage 6b FLASH ADC reduces power consumption and chip area by 50%. The prototype ADC in a 0.13um 1P7M CMOS technology demonstrates a measured DNL and INL within 0.40LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 60.0dB and a maximum SFDR of 72.4dB at 100MS/s, respectively. The ADC with an active die area of 0.92 $mm^2$ consumes 24mW at 1.0V and 100MS/s. The FOM, power/($f_s{\times}2^{ENOB}$), of 0.29pJ/conv. is the lowest of ever reported 12b 100MS/s ADCs.

Tandem Mass Spectrometric Analysis for Disorders in Amino, Organic and Fatty Acid Metabolism : 2 Years of SCL Experience in Korea

  • Yoon, Hye-Ran;Lee, Kyung Ryul
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.3 no.1
    • /
    • pp.86-93
    • /
    • 2003
  • Background : The SCL began screening of newborns and high risk group blood spots with tandem mass spectrometry (MS/MS) in April 2001. Our goal was to determine approximate prevalence of metabolic disorders, optimization of decision criteria for estimation of preventive effect with early diagnosis. This report describes the ongoing effort to identify more than 30 metabolic disorders by MS/MS in South Korea. Methods : Blood spot was collected from day 2 to 30 (mostly from day 2 to 10) after birth for newborn. Blood spot of high risk group was from the pediatric patients in NICU, developmental delay, mental retardation, strong family history of metabolic disorders. One punch (3.2 mm ID) of dried blood spots was extracted with $150{\mu}L$ of methanol containing isotopically labelled amino acids (AA) and acylcarnitines (AC) internal standards. Butanolic HCl was added and incubated at $65^{\circ}C$ for 15 min. The butylated extract was introduced into the inlet of MS/MS. Neutral loss of m/z 102 and parent ion mode of m/z 85 were set for the analyses of AA and AC, respectively. Diagnosis was confirmed by repeating acylcarnitine profile, urine organic acid and plasma amino acid analysis, direct enzyme assay, or molecular testing. Results : Approximately 31,000 neonates and children were screened and the estimated prevalence (newborn/high risk group), sensitivity, specificity and recall rate amounted to 1:2384/1:2066, 96.55%, 99.98%, and 0.73%, respectively. Confirmed 28 (0.09%) multiple metabolic disorders (newborn/high risk) were as follows; 13 amino acid disorders [classical PKU (3/4), BH4 deficient-hyperphenylalaninemia (0/1), Citrullinemia (1/0), Homocystinuria (0/2), Hypermethioninemia (0/1), Tyrosinemia (1/0)], 8 organic acidurias [Propionic aciduria (2/1), Methylmalonic aciduria (0/1), Isovaleric aciduria (1/1), 3-methylcrotonylglycineuria (1/0), Glutaric aciduria type1 (1/0)], 7 fatty acid oxidation disorders [LCHAD def. (2/2), Mitochondrial TFP def. (0/1), VLCAD def. (1/0), LC3KT def. (0/1). Conclnsion : The relatively normal development of 10 patients with metabolic disorders among newborns (except for the expired) demonstrates the usefulness of newborn screening by MS/MS for early diagnosis and medical intervention. However, close coordination between the MS/MS screening laboratory and the metabolic clinic/biochmical geneticists is needed to determine proper decision of screening parameters, confirmation diagnosis, follow-up scheme and additional tests.

  • PDF

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF

Method and proficiency test for analysis of toxic metals in livestock products by ICP/MS (ICP/MS를 이용한 축산물의 유해중금속 분석방법 및 숙련도 검증)

  • Jang, Jung-Hee;Kim, Dong-Gyu;Kwon, Hyun-Jeong;Lim, Chae-Mi;Son, Seong-Wan;Kim, MeeKyung
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • The analytical method of trace toxic metals in livestock products was confirmed and validated through certified reference material (CRM) and the international proficiency tests. There are some difficulties to determine low levels of toxic metals in livestock products because of interferences due to the matrix. The recoveries of CRM (NIST 1577c) ranged from 73.9 to 119% for lead and from 86.4 to 111% for cadmium in bovine liver. The international proficiency tests were carried out with the milk powder and cocoa powder samples including metals provided by Food Analysis Performance Assessment Scheme (FAPAS$^{(R)}$, UK). The test samples were prepared by microwave digestion using solution of $HNO_3:H_2O_2:H_2O$ (v/v/v = 5 : 2 : 4) and analyzed by ICP/MS. The analytical result of cadmium in milk powder was $121{\mu}g/kg$ with -0.3 of the z-score compared to the assigned value of $131{\mu}g/kg$ by FAPAS$^{(R)}$. The analytical results of lead and cadmium in cocoa powder were $29.2{\mu}g/kg$ and $97.6{\mu}g/kg$, respectively, which satisfied the assigned values of $34.2{\mu}g/kg$ for lead and $126{\mu}g/kg$ for cadmium by FAPAS$^{(R)}$. It is verified that the analytical method is accurate and reliable to determine trace lead and cadmium in livestock products by microwave digestion and ICP/MS.

Novel Impulsive Driving Schemes for 120Hz LCD Panels

  • Nam, Hyoung-Sik;Oh, Jae-Ho;Shin, Byung-Hyuk;Oh, Kwan-Young;Berkeley, Brian H.;Kim, Nam-Deog;Kim, Sang-Soo
    • Journal of Information Display
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Two new impulsive driving technologies for 120Hz liquid crystal display (LCD) panels are proposed to improve moving picture quality. One technology generates the dark frame using an adder and a shifter simply without using any look up tables (LUTs). It results in a cost effective impulsive scheme with motion picture quality comparable to that of high speed driving. The other is a backlight flashing method designed to avoid ghost images. The issue of ghost images caused by the slow response time of liquid crystal (LC) is solved by means of 120Hz overdriving and 120Hz backlight flashing. Using the perceived blur edge time (PBET) metric, measured moving picture response time (MPRT) values were 10.8ms and 4.4ms, respectively, while that of 120Hz high speed driving was 10.1ms.