• 제목/요약/키워드: MRI-guided

검색결과 84건 처리시간 0.022초

파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술 (Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease)

  • 이경진;손형선;박성찬;조경근;박해관;최창락
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권1호
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

영상 유도 수술의 환자 및 CT 데이터 좌표계 정렬을 위한 HK 곡률 기술자 기반 표면 정합 방법 (HK Curvature Descriptor-Based Surface Registration Method Between 3D Measurement Data and CT Data for Patient-to-CT Coordinate Matching of Image-Guided Surgery)

  • 권기훈;이승현;김민영
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.597-602
    • /
    • 2016
  • In image guided surgery, a patient registration process is a critical process for the successful operation, which is required to use pre-operative images such as CT and MRI during operation. Though several patient registration methods have been studied, we concentrate on one method that utilizes 3D surface measurement data in this paper. First, a hand-held 3D surface measurement device measures the surface of the patient, and secondly this data is matched with CT or MRI data using optimization algorithms. However, generally used ICP algorithm is very slow without a proper initial location and also suffers from local minimum problem. Usually, this problem is solved by manually providing the proper initial location before performing ICP. But, it has a disadvantage that an experience user has to perform the method and also takes a long time. In this paper, we propose a method that can accurately find the proper initial location automatically. The proposed method finds the proper initial location for ICP by converting 3D data to 2D curvature images and performing image matching. Curvature features are robust to the rotation, translation, and even some deformation. Also, the proposed method is faster than traditional methods because it performs 2D image matching instead of 3D point cloud matching.

Effects of steroid injection during rehabilitation after arthroscopic rotator cuff repair

  • Ha, Joong-Won;Kim, Hyunkyo;Kim, Seong Hun
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.166-171
    • /
    • 2021
  • Background: This study aims to compare the clinical outcomes of steroid injections during the rehabilitation period after arthroscopic rotator cuff repair (ACRC). Methods: Among patients who underwent ARCR, 117 patients who met the inclusion and exclusion criteria were enrolled. Pain and range of motion (ROM) recovery at the 3-, 6-, and 24-month follow-up visits and functional outcome at the 24-month follow-up were compared between 45 patients who received ultrasound-guided subacromial steroid injection at postoperative week 4 or 6 and 72 patients who did not. Functional outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) score and Constant score. Healing of the repaired tendon and retear were observed at the 6-month follow-up via magnetic resonance imaging (MRI) or computed tomography (CT) arthrography. Results: At the 3-month follow-up, the steroid injection group showed lower visual analog scale scores than the control group (p<0.05) and showed faster recovery of forward flexion and internal rotation (p<0.05). From the 6-month follow-up, the two groups did not show differences in pain and ROM, and the ASES score and Constant score also did not significantly differ at the 24-month follow-up. The two groups did not differ in retear rate as determined by MRI or CT arthrography at the 6-month follow-up. Conclusions: This study demonstrated that ultrasound-guided subacromial steroid injection at 4 or 6 weeks after ARCR leads to quick pain reduction and ROM recovery until 3 months after surgery. Therefore, subacromial steroid injection is speculated to be an effective and relatively safe method to assist rehabilitation.

Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma

  • Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1649-1654
    • /
    • 2013
  • Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.

Preliminary Application of Synthetic Computed Tomography Image Generation from Magnetic Resonance Image Using Deep-Learning in Breast Cancer Patients

  • Jeon, Wan;An, Hyun Joon;Kim, Jung-in;Park, Jong Min;Kim, Hyoungnyoun;Shin, Kyung Hwan;Chie, Eui Kyu
    • Journal of Radiation Protection and Research
    • /
    • 제44권4호
    • /
    • pp.149-155
    • /
    • 2019
  • Background: Magnetic resonance (MR) image guided radiation therapy system, enables real time MR guided radiotherapy (RT) without additional radiation exposure to patients during treatment. However, MR image lacks electron density information required for dose calculation. Image fusion algorithm with deformable registration between MR and computed tomography (CT) was developed to solve this issue. However, delivered dose may be different due to volumetric changes during image registration process. In this respect, synthetic CT generated from the MR image would provide more accurate information required for the real time RT. Materials and Methods: We analyzed 1,209 MR images from 16 patients who underwent MR guided RT. Structures were divided into five tissue types, air, lung, fat, soft tissue and bone, according to the Hounsfield unit of deformed CT. Using the deep learning model (U-NET model), synthetic CT images were generated from the MR images acquired during RT. This synthetic CT images were compared to deformed CT generated using the deformable registration. Pixel-to-pixel match was conducted to compare the synthetic and deformed CT images. Results and Discussion: In two test image sets, average pixel match rate per section was more than 70% (67.9 to 80.3% and 60.1 to 79%; synthetic CT pixel/deformed planning CT pixel) and the average pixel match rate in the entire patient image set was 69.8%. Conclusion: The synthetic CT generated from the MR images were comparable to deformed CT, suggesting possible use for real time RT. Deep learning model may further improve match rate of synthetic CT with larger MR imaging data.

IMAGING IN RADIATION THERAPY

  • Kim Si-Yong;Suh Tae-Suk
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.327-342
    • /
    • 2006
  • Radiation therapy is an important part of cancer treatment in which cancer patients are treated using high-energy radiation such as x-rays, gamma rays, electrons, protons, and neutrons. Currently, about half of all cancer patients receive radiation treatment during their whole cancer care process. The goal of radiation therapy is to deliver the necessary radiation dose to cancer cells while minimizing dose to surrounding normal tissues. Success of radiation therapy highly relies on how accurately 1) identifies the target and 2) aim radiation beam to the target. Both tasks are strongly dependent of imaging technology and many imaging modalities have been applied for radiation therapy such as CT (Computed Tomography), MRI (Magnetic Resonant Image), and PET (Positron Emission Tomogaphy). Recently, many researchers have given significant amount of effort to develop and improve imaging techniques for radiation therapy to enhance the overall quality of patient care. For example, advances in medical imaging technology have initiated the development of the state of the art radiation therapy techniques such as intensity modulated radiation therapy (IMRT), gated radiation therapy, tomotherapy, and image guided radiation therapy (IGRT). Capability of determining the local tumor volume and location of the tumor has been significantly improved by applying single or multi-modality imaging fur static or dynamic target. The use of multi-modality imaging provides a more reliable tumor volume, eventually leading to a better definitive local control. Image registration technique is essential to fuse two different image modalities and has been In significant improvement. Imaging equipments and their common applications that are in active use and/or under development in radiation therapy are reviewed.

Imaging Evaluation of Peritoneal Metastasis: Current and Promising Techniques

  • Chen Fu;Bangxing Zhang;Tiankang Guo;Junliang Li
    • Korean Journal of Radiology
    • /
    • 제25권1호
    • /
    • pp.86-102
    • /
    • 2024
  • Early diagnosis, accurate assessment, and localization of peritoneal metastasis (PM) are essential for the selection of appropriate treatments and surgical guidance. However, available imaging modalities (computed tomography [CT], conventional magnetic resonance imaging [MRI], and 18fluorodeoxyglucose positron emission tomography [PET]/CT) have limitations. The advent of new imaging techniques and novel molecular imaging agents have revealed molecular processes in the tumor microenvironment as an application for the early diagnosis and assessment of PM as well as real-time guided surgical resection, which has changed clinical management. In contrast to clinical imaging, which is purely qualitative and subjective for interpreting macroscopic structures, radiomics and artificial intelligence (AI) capitalize on high-dimensional numerical data from images that may reflect tumor pathophysiology. A predictive model can be used to predict the occurrence, recurrence, and prognosis of PM, thereby avoiding unnecessary exploratory surgeries. This review summarizes the role and status of different imaging techniques, especially new imaging strategies such as spectral photon-counting CT, fibroblast activation protein inhibitor (FAPI) PET/CT, near-infrared fluorescence imaging, and PET/MRI, for early diagnosis, assessment of surgical indications, and recurrence monitoring in patients with PM. The clinical applications, limitations, and solutions for fluorescence imaging, radiomics, and AI are also discussed.

Implementation of AAPM's TG-51 Protocol on Co-60 MRI-Guided Radiation Therapy System

  • Cho, Jin Dong;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in;Wu, Hong-Gyun;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.190-196
    • /
    • 2017
  • For the $ViewRay^{(R)}$ system (ViewRay Inc., Cleveland, OH, USA) which is representative of magnetic resonance (MR) guided radiotherapy machine, it is important to evaluate effectiveness of AAPM's TG-51 protocol and the effect of the magnetic field on absolute dosimetry. In order to measure the absolute dose, MR-compatible chamber and water phantom system manufactured in this study were used. The materials of the water phantom system were plastic of polymethyl methacrylate (PMMA) and non-ferrous materials. Due to the inherent feature of the $ViewRay^{(R)}$, all Co-60 sources are not located at gantry angle of $0^{\circ}$ while being located at gantry angle of $90^{\circ}$. For this reason, absolute dosimetry was performed based on the measurements in solid water phantom (SWP) and water which determine the SWP to water correction factor. For evaluation of output constancy with gantry angle, measurements were made with ionization chamber inserted in cylindrical water-equivalent phantom. For measured doses in water, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -0.27%, -0.45% and -0.22%, respectively. For measured doses in SWP, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -1.91%, -2.07% and -1.84%, respectively. All values of dose measured in SWP tended to be less than those measured in water by -1.63%. With the reference gantry angles of $0^{\circ}$ and $90^{\circ}$, the maximum values of deviation for Head 1, Head 2 and Head 3 were 0.48%, 1.06% and 0.40%, respectively. The measurement agreement is within the range of results obtainable for conventional treatment machines. The low strength of the magnetic field does not affect dose measurements. Using the SWP to water correction factor, absolute doses for $ViewRay^{(R)}$ system can be measured.

유두 종양의 자기공명 영상소견 (MR Findings of Papillary Neoplasms of the Breast)

  • 조예슬;김성헌;강봉주;최병길
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.43-51
    • /
    • 2014
  • 목적 : 유방암을 진단 받은 환자의 자기공명영상에서 추가적으로 발견된 유두상 병변의 자기공명영상 소견과 수술적 절제 후 상향화 비율을 알아보고자 한다. 대상 및 방법 : 본원에서 유방암 진단된 환자의 수술 전 자기공명영상 1729건에서 지표 종양 외에 악성 의심 조영증강을 보인 병변 중 초음파 유도하 핵생검에서 유두 종양으로 진단된 21명의 환자의 22개 병변을 대상으로 하였다. 이 중 수술적 절제를 시행한 병변은 핵생검 결과와 절제 생검 결과를 비교하였다. 또한 이 병변들의 자기공명영상 소견을 BI-RADS MRI lexicon에 따라 후향적으로 분석하여 특징을 알아보았다. 결과 : 자기공명영상에서는 종괴 8예, 비종괴 7예, 초점 7예로 관찰되었고 초점으로 나타난 병변은 병리 조직에서 모두 (100%) 양성 병변으로 진단되었고, 역동적 조영증강 검사에서 고원형과 세척형 양상을 보였다. 양성 유두종 1예 (11.1%), 비정형요소를 가진 유두 종양 3예 (100%), 유두 종양 3예 (60%)가 수술적 절제 후 관상피내암, 침윤성 관상피암, 침윤성 소엽암 등으로 상향화되었다. 결론 : 초음파 유도하 핵생검에서 유두상 병변으로 진단된 병변들의 자기공명영상 소견은 양성과 악성을 예측하기에 특징적인 차이점을 보이지 않아 영상소견만으로 양성과 악성을 구분할 수 없으며 다수에서 수술적 절제 후 조직학적 상향화를 보여 (41.2%, 7/17) 반드시 수술적 절제를 통한 확진이 필요할 것이다.

Surgical Management Options for Trigeminal Neuralgia

  • Lunsford, L. Dade;Niranjan, Ajay;Kondziolka, Douglas
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권6호
    • /
    • pp.359-366
    • /
    • 2007
  • Trigeminal neuralgia is a condition associated with severe episodic lancinating facial pain subject to remissions and relapses. Trigeminal neuralgia is often associated with blood vessel cross compression of the root entry zone or more rarely with demyelinating diseases and occasionally with direct compression by neoplasms of the posterior fossa. If initial medical management fails to control pain or is associated with unacceptable side effects, a variety of surgical procedures offer the hope for long-lasting pain relief or even cure. For patients who are healthy without significant medical co-morbidities, direct microsurgical vascular decompression [MVD] offers treatment that is often definitive. Other surgical options are effective for elderly patients not suitable for MVD. Percutaneous retrogasserian glycerol rhizotomy is a minimally invasive technique that is based on anatomic definition of the trigeminal cistern followed by injection of anhydrous glycerol to produce a weak neurolytic effect on the post-ganglionic fibers. Other percutaneous management strategies include radiofrequency rhizotomy and balloon compression. More recently, stereotactic radiosurgery has been used as a truly minimally invasive strategy. It also is anatomically based using high resolution MRI to define the retrogasserian target. Radiosurgery provides effective symptomatic relief in the vast majority of patients, especially those who have never had prior surgical procedures. For younger patients, we recommend microvascular decompression. For patients with severe exacerbations of their pain and who need rapid response to treatment, we suggest glycerol rhizotomy. For other patients, gamma knife radiosurgery represents an effective management strategy with excellent preservation of existing facial sensation.