18-FDG EXTERNAL RADIATION DOSE RATES IN DIFFERENT BODY REGIONS OF PET-MRI PATIENTS

  • Han, Eunok;Kim, Ssangtae
    • Journal of Radiation Protection and Research
    • /
    • 제38권3호
    • /
    • pp.157-165
    • /
    • 2013
  • To determine the factors affecting the external radiation dose rates of patients undergoing PET-MRI examinations and to assess the trends of these differences, we measured the changes in the dose rates of $^{18}F$-FDG during a set period of time for each body region. Consistent with theoretical predictions, the dose rate decreased over time in patients undergoing PET-MRI examinations. Furthermore, immediately after the $^{18}F$-FDG injection, the dose rate in the chest region was the highest, followed by the abdominal region, the head region, and the foot region. The dose rate decreased drastically as time passed, by 2.47-fold, from $339.23{\pm}74.70mSv\;h^{-1}$ ($6.73{\pm}5.79$ min) at the time point immediately after the $^{18}F$-FDG injection to $102.71{\pm}26.17mSv\;h^{-1}$ ($136.11{\pm}25.64$ min) after the examination. In the foot region, there were no significant changes over time, from $32.05{\pm}20.23mSv\;h^{-1}$ ($6.73{\pm}5.79$ min) at the time point immediately after the $^{18}F$-FDG injection, to $23.89{\pm}9.14mSv\;h^{-1}$ ($136.11{\pm}25.64$ min) after the examination. The dose rate is dependent on the individual characteristics of the patient, and differed depending on the body region and time point. However, the dose rates were higher in patients who had a lower body weight, shorter stature, fewer urinations, lower fluid intake, and history of diabetes mellitus. To decrease radiation exposure, it is difficult or impossible to change factors inherent to the patient, such as sex, age, height, body weight, obesity, and history of diabetes mellitus. However, factors which can be changed, such as the $^{18}F$-FDG dose, fasting time, fluid intake, number of urinations, and contrast agent dose can be controlled to minimize the external radiation exposure of the patient.

Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가 (In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant)

  • 연규진;김현수;이승근;이태수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.19-25
    • /
    • 2017
  • 본 연구는 1.5 T와 3.0 T Magnetic Resonance Imaging에서 Bone-Anchored Hearing Aid (BAHA) implant의 수평인력, 회전력, 그리고 자화감수성 인공물의 크기를 표준측정 방법에 의해 측정하여 MR 안전성을 평가하였다. BAHA implant의 고정장치와 지지대는 0.5%의 철(iron)이 포함 된 티타늄으로 만들어졌으며, 길이는 10 mm (고정장치 4 mm, 지지대 6 mm), 최대 직경은 7.0 mm이다. 수평인력 측정장치와 자화감수성 인공물 측정장치는 각각 American Society for Testing and Materials (ASTM) F2052-06, F2119-07을 참조하여 아크릴을 이용해 제작했으며, 회전력 측정은 원형 플라스틱 용기를 이용한 측정장치를 사용하였다. 자기유도에 의한 BAHA implnat의 수평인력은 주자장이 가장 큰 지점인 96 cm지점에서 최대 변위각을 측정하였고, 회전력은 원형용기 내부의 $45^{\circ}$간격의 실선 위에 놓았을 때 나타난 회전형태를 정성적 평가기준으로 측정하였다. 자화감수성 인공물은 황산구리($CuS0_4$) 용액이 채워진 용기의 중앙에 BAHA implant를 매달아 영상을 획득한 후 Susceptibility Artifact Measurement (SAM) software를 이용해 크기를 측정하였다. 측정결과 수평인력은 1.5 T와 3.0 T에서 변위각과 변위력은 모두 0으로 나타났다. 회전력은 1.5 T에서는 0(no torque), 3.0 T에서는 +1(mild torque)로 나타났다. 자화감수성 인공물은 최소 13.20 mm, 최대 38.91 mm의 크기로 나타났다. 따라서 1.5 T, 3.0 T의 MR 환경에서 BAHA implant는 환자에게 안전하다.

뉴로-퍼지를 이용한 스펙클 제거 (Speckle Reduction based on Neuro-Fuzzy Technique)

  • 길세기;전유용;오형석;서촌민박;권장우;이상민
    • 전기전자학회논문지
    • /
    • 제12권3호
    • /
    • pp.158-166
    • /
    • 2008
  • 의용 초음파 장비는 X-Ray, CT, MRI 등 다른 의료 장비보다 휴대성과 안전성면에서는 장점이 있지만 진단 시 해상도와 화질 저하를 유발하는 스펙클이 생기는 단점이 있다. 그러나 단순한 스펙클 잡음의 제거는 경계선 정보의 손실을 발생시킬 수도 있다. 이에 본 논문에서는 효과적인 스펙클 제거와 손실 없는 경계선 검출을 위해 뉴럴네트워크와 퍼지 클러스터링을 이용한 뉴로-퍼지 스펙클 제거 방법을 제안하였다. 제안된 방법은 입력된 의용 초음파 영상에 대해 먼저 퍼지 클러스터링을 적용하여 세 영역으로 나누고 이후 각 영역별로 별도의 뉴럴 네트워크를 적용하는 방법이다. 실제 실험 및 기존 방법들과의 정성적?정량적 비교 분석을 통해 제안 방법의 유용성을 검증하였다.

  • PDF

A Minimally Invasive Rabbit Model of Progressive and Reproducible Disc Degeneration Confirmed by Radiology, Gene Expression, and Histology

  • Kwon, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권6호
    • /
    • pp.323-330
    • /
    • 2013
  • Objective : To develop a simple, reproducible model of disc degeneration in rabbits through percutaneous annular puncture and to confirm the degree of degeneration over time. Methods : Fifteen New Zealand white rabbits (4 to 5 months old and weighing approximately 3 to 3.5 kg each) underwent annular puncture of the L2-L3, L3-L4, and L4-L5 discs. Rabbits were sacrificed at 4, 8, or 20 weeks after puncture. For a longitudinal study to assess changes in disc height over time, serial X-rays were performed at 0, 2, 4, 8, and 20 weeks for rabbits in the 20-week group. Upon sacrifice, the whole spinal column and discs were extracted and analyzed with magnetic resonance imaging (MRI), real time reverse transcriptase-polymerase chain reaction, and histological staining. Results : The X-rays showed a slow, progressive decrease in disc height over time. Significant disc space narrowing compared to preoperative disc height was observed during the time period (p<0.001). The MRI grade, aggrecan, and matrix metalloprotease-13 mRNA expression and hematoxylin and eosin/safranin O/anti-collagen II staining were consistently indicative of degeneration, supporting the results of the X-ray data. Conclusion : Percutaneous annular puncture resulted in slow, reproducible disc degeneration that was confirmed by radiology, biochemistry, and histology. This in vivo model can be used to study and evaluate the safety and efficacy of biologic treatments for degenerative disc disease.

성인에서의 병적 위치 변형이 없는 아킬레스건 종골 후방 부착부의 특징: 자기공명영상 계측 연구 (Characteristics of Achilles Tendon Insertion on Posterior Aspect of the Calcaneus without Pathological Deformity in Adults: A Magnetic Resonance Imaging Study)

  • 곽희철;정대원;박형택;하동준;곽재용;김의철
    • 대한족부족관절학회지
    • /
    • 제20권3호
    • /
    • pp.112-115
    • /
    • 2016
  • Purpose: We aimed to investigate the safety zone for Achilles tendon insertion in the posterior aspect of the calcaneus via the use of magnetic resonance imaging (MRI) when planning for insertional Achilles tendinopathy. Materials and Methods: This study included 95 patients. The MRI of midsagittal plane of the ankle joint was used to measure the proximal and distal insertion point for the Achilles tendon in the posterior aspect of the calcaneus. Patients were divided into three groups according to the proportion of the distal insertion point out of the entire calcaneal length: the proximal, middle, and distal insertion groups. Results: The mean proximal and distal insertion points for the Achilles tendon were measured as 1.05 cm (0~2.11 cm) and 2.36 cm (1.60~2.93 cm), respectively. When the posterior aspect of the calcaneus was used as the reference plane, none of the patients was in the proximal insertion group, while 75 and 20 patients were in the middle and distal insertion groups, respectively. The insertion portion was longer in the distal insertion group ($1.47{\pm}0.25cm$) than in the middle insertion group ($1.27{\pm}0.35cm$). Statistically significant differences with respect to the length of the insertion portion were observed between the two groups (p=0.008). Conclusion: Removal of more than 1 cm below the superior margin of the posterior calcaneus may be dangerous. An MRI study on the Achilles tendon of patients without hindfoot deformity or tendinopathy revealed various insertional characteristics. Preoperative MRI evaluation is safer than relying solely on the simple radiological assessment when planning for insertional Achilles tendinopathy.

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

Single Stage Circumferential Cervical Surgery (Selective Anterior Cervical Corpectomy with Fusion and Laminoplasty) for Multilevel Ossification of the Posterior Longitudinal Ligament with Spinal Cord Ischemia on MRI

  • Son, Seong;Lee, Sang-Gu;Yoo, Chan-Jong;Park, Chan-Woo;Kim, Woo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권4호
    • /
    • pp.335-341
    • /
    • 2010
  • Objective : Anterior cervical corpectomy with fusion (ACF) or laminoplasty may be associated with substantial number of complications for treating multilevel cervical ossification of the posterior longitudinal ligament (OPLL) with significant cord compression. For more safe decompression and stabilization in multilevel cervical OPLL with prominent cord compression, we propose circumferential cervical surgery (selective ACF and laminoplasty) based on our favorable experience. Methods : Twelve patients with cervical myelopathy underwent circumferential cervical surgery and all patients showed multilevel OPLL with Signal change of the spinal cord on magnetic resonance imaging (MRI). A retrospective review of clinical, radiological. and surgical data was conducted. Results : There were 9 men and 3 women with mean age of 56.7 years and a mean follow up period of 15.6 months. The average corpectomy level was 1.16 and laminoplasty level was 4.58. The average Japanese Orthopedic Association score for recovery was 5.1 points and good clinical results were obtained in 11 patients (92%) (p < 0.05). The average space available for the cord improved from 58.2% to 87.9% and the average Cobb's angle changed from 7.63 to 12.27 at 6 months after operation without failure of fusion (p < 0.05). Average operation time was 8.36 hours, with an estimated blood loss of 760 mL and duration of bed rest of 2.0 days. There were no incidences of significant surgical complications, including wound infection. Conclusion : Although the current study examined a small sample with relatively short-term follow-up periods, our study results demonstrate that circumferential cervical surgery is considered favorable for safety and effectiveness in multilevel OPLL with prominent cord compression.

Clinical Outcomes of Percutaneous Plasma Disc Coagulation Therapy for Lumbar Herniated Disc Diseases

  • Kim, Sang-Hyun;Kim, Sung-Chul;Cho, Ki-Hong
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권1호
    • /
    • pp.8-13
    • /
    • 2012
  • Objective : This is prospective study of clinical outcomes of percutaneous plasma disc coagulation Therapy (PDCT) in patients with herniated lumbar disc disease (HLD) to evaluate the safety and efficacy in its clinical application and usefulness as a reliable alternative to microscopic discectomy. Methods : Forty-six patients were enrolled in this study from April 2006 to June 2010. All patients had one-level HLD. Disc degeneration was graded on routine T2-weighted magnetic resonance Image (MRI) using the Pfirrmann's grading system and all index levels were grade 3 and grade 4. Indications for surgery were radiculopathy caused by disc protrusion with soft consistency. MRI was done at one month after the procedure in all patients to check post-PDCT change. The clinical outcomes were evaluated using Visual Analog Scales (VAS) score and MacNab's criteria. Results : This study was approved by the Institutional Review Board of our institution. The age of the study population ranged from 16 to 59 years with a mean age of 37.2 years. There were 29 males and 17 females in this study. The mean period of clinical follow-up was 21 months. The average preoperative VAS score for radiculopathy was $7.4{\pm}1.4$, while the final follow-up VAS score was $1.4{\pm}0.7$ (p<0.001). In MacNab's criteria, 41 patients (89.1%) had achieved favorable improvement (excellent and good) until later follow-up. There were one patient from infection and two patients who needed to convert to open discectomy. Conclusion : PDCT is a safe and efficient treatment modality in a selective patient with HLD.

Safety of Administering Intravenous CT Contrast Agents Repeatedly or Using Both CT and MRI Contrast Agents on the Same Day: An Animal Study

  • Heejin Bae;Hyewon Oh;Ga Bin Park;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • 제25권3호
    • /
    • pp.257-266
    • /
    • 2024
  • Objective: To investigate molecular and functional consequences of additional exposures to iodine- or gadolinium-based contrast agents within 24 hours from the initial intravenous administration of iodine-based contrast agents through an animal study. Materials and Methods: Fifty-six Sprague-Dawley male rats were equally divided into eight groups: negative control, positive control (PC) with single-dose administration of CT contrast agent, and additional administration of either CT or MR contrast agents 2, 4, or 24 hours from initial CT contrast agent injection. A 12 µL/g of iodinated contrast agent or a 0.47 µL/g of gadolinium-based contrast agent were injected into the tail vein. Serum levels of blood urea nitrogen, creatinine, cystatin C (Cys C), and malondialdehyde (MDA) were measured. mRNA and protein levels of kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL) were evaluated. Results: Levels of serum creatinine (SCr) were significantly higher in repeated CT contrast agent injection groups than in PC (0.21 ± 0.02 mg/dL for PC; 0.40 ± 0.02, 0.34 ± 0.03, and 0.41 ± 0.10 mg/dL for 2-, 4-, and 24-hour interval groups, respectively; P < 0.001). There was no significant difference in the average Cys C and MDA levels between PC and repeated CT contrast agent injection groups (Cys C, P = 0.256-0.362; MDA, P > 0.99). Additional doses of MR contrast agent did not make significant changes compared to PC in SCr (P > 0.99), Cys C (P = 0.262), and MDA (P = 0.139-0.771) levels. mRNA and protein levels of KIM-1 and NGAL were not significantly different among additional CT or MR contrast agent groups (P > 0.05). Conclusion: A sufficient time interval, probably more than 24 hours, between repeated contrast-enhanced CT examinations may be necessary to avoid deterioration in renal function. However, conducting contrast-enhanced MRI on the same day as contrast-enhanced CT may not induce clinically significant kidney injury.