• 제목/요약/키워드: MRI artifact

검색결과 112건 처리시간 0.023초

EEG Current Source Imaging using VEP Data Recorded inside a 3.0T MRI Magnet

  • Han Jae Y.;Choi Young H.;Im Chang H.;Kim Tae-S.;Lee Soo Y.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권2호
    • /
    • pp.95-99
    • /
    • 2005
  • We have performed EEG current source imaging on the cortical surface using visual evoked potentials (VEPs) recorded inside a 3.0 T MRI magnet. In order to remove ballistocardiogram (BCG) artifacts in the VEPs, an improved BCG template subtraction technique is devised. Using the cortically constrained current source imaging technique and pattern-reversal visual stimulations, we have obtained current source maps from 10 subjects. To validate the EEG current source imaging inside the magnet, we have compared the current source maps to the ones obtained outside the magnet. The experimental results demonstrate that there is a strong correspondence between the current source maps, proving that current source imaging is feasible with the evoked potentials recorded inside a 3.0 T MRI magnet.

MRI 촬상단면내의 체동 아티팩트의 제거 (Cancellation of Motion Artifact in MRI Image Plane)

  • 김응규;권영도
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.1075-1078
    • /
    • 1999
  • In this study, a new algorithm for canceling MRI artifacts through the translational motion of image plane is presented. Bloating is often makes problems in a clinical diagnosis. Assuming that the head moves up and down due to breathing, rigid translational motions in only y(phase encoding axis) direction is treated. First, we notice that the x directional motion corresponds to a shift of the x directional spectrum of the MRI signal, and the non zero area of the spectrum just corresponds to x axis projected area of the density function. So the motion is estimated by tracing the edges of the spectrum, and the x directional motion is canceled by shifting the spectrum in inverse direction. Next, the y directional motion is canceled using a new constraint, with which the motion component and the true image component can be separated. Finally, the effectiveness of this algorithm is shown by using a phantom with simulated motions.

  • PDF

회전운동에 의한 MRI 아티팩트의 제거 (Cancellation of MRI Artifact due to Rotation Motion)

  • 김응규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2746-2748
    • /
    • 2002
  • MRI 스캔중 촬상 대상물의 화상평면내에서의 회전은 MRI 신호에 위상오차와 불균일 표본화를 일으킨다. 따라서, 아티팩트가 포함된 MR 화상의 화질열화를 개선하기 위하여 다음과 같은 방법들을 제안한다. 우선, 미리 주어진 회전파라메타로서 쌍일차 보간과 중첩특성을 이용해서 k공간 불균일 표본화 데이터를 수정하는 알고리즘과, 2차원 회전운동의 회전각은 이미 알려져 있고, 회전중심 위치가 미지인 경우에 대해 아티팩트를 보정하는 알고리즘을 제안한다. 이 때, 미지운동 파라메타를 예측하기 위해 촬상대상물의 경계바깥쪽에서 이상적인 MR 화상의 에너지는 최소가 되고, 촬상 대상물의 회전이 존재할 때 측정된 에너지가 증가한다는 성질을 이용했다. 이러한 성질을 이용해서 시뮬레이션 화상에 적용한 결과 제안한 방법에 대한 유효성을 확인하였다.

  • PDF

화상평면내 회전운동에 의한 MRI 아티팩트의 제거 (Cancellation of MRI Artifact due to Rotational Motion in Image Plane)

  • 김응규;이충호
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2002년도 봄 학술발표논문집 Vol.29 No.1 (B)
    • /
    • pp.601-603
    • /
    • 2002
  • MRI 스캔중 촬상 대상물의 화강평면내에서의 회전은 MRI 신호에 위상오차와 불균일 표본화를 일으킨다. 따라서, 아티팩트가 포함된 MR 화상의 화질열화를 개선하기 위하여 다음과 같은 방법들을 제안한다. 우선, 미리 주어진 회전파라메타써 쌍일처 보간과 중첩 특성을 이용해서 k 공간 불균일 표본화 데이터를 수정하는 알고리즘과, 2차원 회전운동의 회전각은 이미 알려져 있고, 회전중심 위치가 미지인 경우에 대해 위상보정에 기초한 아티팩트를 보정하는 알고리즘 및 회전중심과 각도가 모두 미지인 2차원 회전운동에 대해 아티팩느를 보정하는 알고리즘을 제안한다. 이 때, 미지운동 파라메타를 예측하기 위해 찰상대상물의 경계바깥쪽에서 이상적인 MR 화상의 에너지는 최소가 되고, 활상 대상물의 회전이 존재할 때 측정된 에너지가 증가한다는 성질을 이용했다. 이러만 성질을 이용해서 시뮬레이션 화상에 적용한 결과 제안한 방법에 대한 유효성을 확인하였다.

  • PDF

MRI내 회전운동에 기인한 아티팩트 제거 (Artifact Cancellation due to Rotational Motion in MRI)

  • 김응규;이수종
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.155-158
    • /
    • 2005
  • MRI 스캔시 화상평면내에서 촬상대상물체의 회전은 MRI 신호에 위상오차와 불균일 표본화를 일으킨다. MRI 신호의 위상오차와 불균일 표본화에 대한 문제의 모델은 화상평면내 임의 중심과 원점에 관한 회전운동에 의해 열화된 MRI 신호들사이에 위상차가 존재함을 나타낸다. 이에 아티팩트가 포함된 MR 화상의 화질을 개선하기위해서 다음과 같은 방법을 제안한다. 우선, 2차원 회전운동의 회전각은 이미 알려져 있고, 회전중심의 위치가 미지인 경우에 대해 위상보정에 기초한 아티팩트를 보정하는 알고리즘과, 다음으로, 회전중심과 각도가 모두 미지인 2차원 회전운동에 대해 아티팩트를 보정하는 알고리즘을 제안한다. 이때, 미지 운동 파라메타를 예측하기위해 촬상대상물체의 경계바깥쪽에서 이상적인 MR 화상의 에너지는 최소가 되고, 촬상대상물체의 회전이 존재할 때 측정된 에너지는 증가한다는 성질을 이용한다. 이러한 성질을 이용해서 각 위상부호화 단계에서 미지의 회전각 크기를 추정하기위한 평가함수가 도입된다. 최종적으로 시뮬레이션 화상 및 실제화상에 적용해서 제안한 본 방법의 유효성을 확인한다.

  • PDF

적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법 (Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter)

  • 박호동;장봉렬;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석 (Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique)

  • 이보우;박명철;이진회;김기진;배석환
    • 디지털융복합연구
    • /
    • 제12권10호
    • /
    • pp.385-390
    • /
    • 2014
  • 이 연구의 목적은 복부 MRI검사에 유용한 m-DIXON기법이 기존 e-THRIVE기법에 비해 임상적으로 유용한 검사인지 알아보기 위해 2013년 9월부터 2014년 2월까지 간 질환을 주소로 복부 MRI검사를 시행한 84명을 대상으로 분석하였다. 연구결과에서 SNR은 m-DIXON기법 $90.42{\pm}16.90$, e-THRIVE $60.42{\pm}11.54$로 나타났으며, CNR은 m-DIXON기법 $52.38{\pm}22.58$, e-THRIVE기법 $46.31{\pm}20.25$로 나타났다. 정성적 평가는 m-DIXON기법에서 영상의 질 $4.06{\pm}0.34$, 인공물 $3.64{\pm}0.22$, 지방소거 $4.16{\pm}0.15$로 나타났으며, e-THRIVE기법에서 영상의 질 $3.14{\pm}0.35$, 인공물 $3.06{\pm}0.38$, 지방소거 $3.14{\pm}0.30$으로 나타났다. 결론적으로 복부 MRI검사에서 m-DIXON기법은 e-THRIVE 기법에 비해 정량적 평가 및 정성적 평가에서 우수한 것으로 나타나, 향후 복부질환의 진단에 유용하게 활용할 것을 제안한다.

자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구 (Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study)

  • 김남영;김주희;임준;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.9-14
    • /
    • 2021
  • 방사선에 의한 피폭 없이 대조도가 우수한 영상의 획득이 가능한 자기공명영상은 진단에 필수적이지만 영상에서의 노이즈 발생은 불가피한 요소이기 때문에 이를 보완하기 위해 자기공명영상장치의 변수들을 조절하여 우수한 특성을 가진 영상을 획득할 수 있다. 이 중, 여기횟수 (NEX; number of excitation)는 추가적인 영상 특성의 저하 없이 우수한 특성의 영상을 획득할 수 있지만 scan time이 증가하여 motion artifact를 발생시킬 수 있고, scan time의 증가에 비례하여 영상의 특성이 향상되지 않기 때문에 적절한 NEX의 설정이 필요하다. 따라서, 본 연구에서는 MRiLab simulation program을 통해 자기공명영상의 모든 변수들을 고정시킨 후, NEX만을 조절하여 획득한 뇌 T2 강조 영상의 정량적 평가를 통해 NEX 변화에 따른 영상 특성의 경향성을 평가하고자 하였다. 획득한 영상의 노이즈 레벨 및 유사도 평가를 하기 위해 신호 대 잡음비 (SNR; signal to noise ratio), 대조도 대 잡음비 (CNR; contrast to noise ratio), 평균 제곱근 오차 (RMSE; root mean square error) 그리고 최대 신호 대 잡음비 (PSNR; peak signal to noise ratio)를 계산하였다. 결과적으로, 노이즈 레벨 및 유사도 평가 인자 모두 NEX가 증가함에 따라 개선된 값을 보였으나, 점차 증가폭이 감소함을 보였다. 따라서, 과도하게 큰 NEX는 장시간의 scan에 따른 motion artifact를 발생시켜 영상 특성을 저하시킬 수 있으므로, 적절한 NEX의 설정이 중요함을 확인하였다.

자장의 세기에 따른 유방 확장기 주위의 인공물 평가 (Evaluation of artifacts around the breast expander according to magnetic field strength)

  • 정동일;김재석
    • 한국정보통신학회논문지
    • /
    • 제24권9호
    • /
    • pp.1144-1149
    • /
    • 2020
  • 유방조직확장기의 Magnetic Valve는 MRI 검사 시 영상 인공물이 발생하여 MRI 검사가 제한적이다. MRI 검사가 필요한 유방조직확장기 삽입 환자에 대해 영상 인공물이 진단영역에 미치는 영향을 평가한다. 자체 제작한 팬텀과 실제 임상 조건을 이용하여 영상 인공물 측정을 실시하였다. 영상 인공물은 1.5 Tesla와 3.0 Tesla 환경에 따라 상이하게 측정되었으며, C-spine, L-spine 검사 시 영상 인공물의 영향이 T-spine에 비해 상대적으로 적었다. 유방암 전이로 인한 MRI 검사가 꼭 필요한 경우 주로 1.5 Tesla에서 Head & Neck 검사와 L-spine 아래 부위를 검사 할 수 있으나 일부 시퀀스에서는 영상 인공물로 인한 왜곡이 발생할 수 있다. 유방조직확장기 삽입 환자의 MRI 검사는 안전성 측면에서는 3.0T는 피하고 1.5T에서 조건부로 가능하다.

복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교 (Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2016
  • 본 연구의 목적은 복부 자기공명영상에서 주로 적용되고 있는 4 종류의 펄스시퀀스를 중심으로 1.5 T 와 3.0 T 기기의 자기장의 차이로 나타나는 자기장의 속성 및 인공물 발생 차이를 비교하기 위해 분석을 하였다. PACS network로 전송된 총 500 명의 데이터를 정량적으로 SNR 값을 분석하였고, MSA, CSA, DA을 3 단계로 구분하여 정성적 평가를 하였다. 정량적 평가에서 SNR 값은 1.5 T 값 보다 의미 있는 결과로 높은 값을 얻었지만(p<0.05), 영상의 인공물이 발생하여 영상의 질을 저하시키는 요인도 있었다(p<0.05). 1.5 T는 3.0 T 보다 인공물 발생이 적어 3.0 T 만큼에 영상의 질을 보상 할 수가 있었다(0.05). 결론적으로, 이러한 결과를 토대로 자기장의 차이에 따라 발생되는 자기장의 속성 및 인공물 발생 차이를 파악 할 수 있었으며 이에 따른 대처방안을 제공할 수 있었다. 향후 임상현장에서 두 기기를 이용하여 복부 자기공명영상을 검사 할 때 환자를 직접 검사하는 MRI 사용자에게 가이드라인이 될 것이다.