Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.78-78
    • /
    • 2002
  • Purpose: The purpose of this study is to describe a distributed circuit approach to high frequency volume coil design illustrated with specific coils built accordingly and results obtained from animal studies at 3.0 tesla. Method: All experiments were conducted on 3T MRI system (Medinus Co., Ltd. Korea). The tuned TEM resonator measures 15cm outer diameter. by 10cm inside diameter by 30cm in length. The inside diameter and length were determined by animals body or head size (eg. rats or small dogs, etc.) while the outer diameter was chosen for compactness with some sacrifice of the optimal coil Q predicted for a larger cavity. A spin echo sequence with a TR/TE/flip angle=500/12.4ms/$75^{\circ}$was used to check image qualities with phantom. The breed of rat which used for animal images was Sprague-dawley(SD) and was anesthetic using ketamin hydrochloride 75mg/kg.

  • PDF

동일한 조건의 자기공명검사에서 코일의 채널수 변화에 따른 신호강도의 평가 (Comparative Study of a Multi-Channel Coils of Magnetic Resonance Imaging(MRI) Signal Intensities under Identical Parameters)

  • 손순룡
    • 한국콘텐츠학회논문지
    • /
    • 제19권6호
    • /
    • pp.418-423
    • /
    • 2019
  • 본 연구는 동일한 조건과 동일한 부위에 채널수가 다른 코일을 적용하여 신호강도를 비교함으로써 신호강도를 향상시키는데 채널수의 관련성을 알아보고자 하였다. 연구방법은 8 채널과 16 채널의 Knee 코일에 전용 팬텀을 장착한 후 T1, T2 강조영상을 획득하여 코일의 채널수에 따라 영상의 신호강도가 어느 정도 차이가 있는지 비교하였다. 연구결과 T1, T2 강조영상 모두 8채널 보다 16 채널 코일을 사용하였을 때 영상의 신호강도가 유의하게 증가하였다. 결론적으로 채널수가 적은 코일 보다는 많은 코일을 사용하는 것이 신호강도를 증가시킬 수 있었으므로 임상적용에 유용성이 크다고 판단된다.

자기공명영상촬영을 위한 Phased-Array Quadrature RF 코일 (Phased-Array Quadrature RF Coil for Magnetic Resonance Imaging)

  • 김선경;양윤정;이덕래;안창범;이흥규;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.227-229
    • /
    • 1997
  • A new phased-array quadrature RF coil for one or two RF acquisition channels is developed for spine MR imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by $"\sqrt{2}"$ using two orthogonal RF coils in combination [1]. More recently, the phased-array RF coil has been proposed for more improvement of SNR by using an array of RF coil elements with a reduced size and coverage for each element. Two new schemes are proposed for the new phased-array quadrature RF coil as follows : (1) Proper overlapping of two quadrature RF coils thus removing the mutual inductance and (2) Attaching preamplifiers right after the coil section and combining the signal with proper phase delays. The coil has been implemented for receive- only mode. It has been tested through phantom and volunteer imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구 (Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;한지현;이시내;한송이;김기원;김현수;손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가 (Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

다양한 MRI 시스템에서 사용가능한 의료용 리드선 (A New Medical Lead for Various MRI Systems)

  • 김홍준;유형석
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.429-432
    • /
    • 2015
  • Radio Frequency (RF) coils in Magnetic Resonance Imaging (MRI) systems interact with a patient's tissues, resulting in the absorption of RF energy by the tissues. The presence of an electrically conducting medical implant may concentrate the RF energy and causes tissue heating near the implant devices. Here we present a novel design for a medical lead to reduce this undesired heating. Specific Absorption Rate (SAR), an indicator of heating, was calculated. Remcom XFdtd software was used to calculate the peak SAR distribution (1g and 10 g) in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T MRI), 128 MHz (3 T MRI) and 300 MHz (7 T MRI) using a model of an MR birdcage body coil. Our results demonstrate that, our proposed design of adding nails to the medical lead can significantly reduce the SAR for different MRI systems.

1.5T 자기공명영상을 이용한 물리적 영상 특성에 대한 연구 (Study on the Physical Imaging Characteristics by Using Magnetic Resonance Imaging 1.5T)

  • 민정환;정회원;한지현;이시내;박장호;김기원;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.329-334
    • /
    • 2019
  • This study was purpose to quantitative evaluation of noise power spectrum(NPS) and studied the quantitative evaluation and characteristics of modulation transfer function(MTF) by obtain the optimal edge image by using Coil in magnetic resonance imaging(MRI) equipment through Fujita theory using edge method. The MRI equipment was used (Tim AVANTO 1.5T, Siemense healthcare system, Germany) and the head matrix coil were 12channels(elements) receive coil. The NPS results of showed the best value of 0.004 based on the T2 Nyquist frequency of $1.0mm^{-1}$, and the MTF results of showed that the T1 and T2 values were generally better than the T1 CE and T1 CE FC values. The characteristics of this study were to explain the characteristic method of image quality evaluation in general. To present the quantitative evaluation process and results in the evaluation of MRI image characteristics in radiology.

3T MR Imaging에 적합한 RF Surface Coil의 개발: 피부 미세구조에 대한 예비 연구

  • 윤성익;이정우;최보영;이형구;서태석
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.73-73
    • /
    • 2003
  • 목적: 피부조직과 같은 미세 인체구조 연구를 위해 고해상도 3T MRI 시스템에 적합한 고분해능의 RF surface coil을 개발하고 있다. In vivo 연구를 위한 여러 parameter를 최적화하여 기능영상에도 부합된다. 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준으로 향상되어 질병의 정확한 진단이 가능해지게 될 것이다.

  • PDF