• Title/Summary/Keyword: MR parameter

Search Result 73, Processing Time 0.029 seconds

Evaluation of Cardiac Ejection Fraction using Cardiac MRI (Cardiac MRI를 이용한 심박출계수의 평가)

  • Eun, Sung-Jong;Kook, Jin-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.289-294
    • /
    • 2011
  • The aim of this study is to evaluate the differences of ejection fraction of left ventricle through the quantitative analysis of diastolic and systolic volumes according to slices selected using cardiac MR imaging. A total of 12 volunteers (7 normal, 1 myocardium bridge, and 4 arrhythmia) underwent cardiac MRI on a MR scanner(Magnetom Trio, Siemens, Germany). Ejection fractions for quantitative analysis were calculated at single slice of center of left ventricle, 3, 5, and 6-7 slices extending from the center of left ventricle. Average values were analyzed for evaluating differences of ejection fraction according to the number of slices selected. Mean value of normal person of ejection fraction were 67.14% at single slice of center of left ventricle, 66.24% at 3 slices, 65.63% at 5 slices, and 65.29% at 6-7 slices. While ejection fraction obtained from a patient with 61.74% at single slice of center of left ventricle, 60.92% at 3 slices, 60.89% at 5 slices, and 61.89% at 6-7 slices. There was no significant differences by the number of slices selected. This study demonstrates that ejection fraction obtained from single slice of center of left ventricle may represent a optimum parameter for cardiac function, instead of the value calculated on the variable slices selected.

Inter-basin water transfer modeling from Seomjin river to Yeongsan river using SWAT (SWAT을 이용한 섬진강에서 영산강으로의 유역간 물이동 모델링)

  • Kim, Yong Won;Lee, Ji Wan;Woo, So Young;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.57-70
    • /
    • 2020
  • This study is to establish the situation of inter-basin transfer from Seomjin river basin to Yeongsan river basin using SWAT (Soil and Water Assessment Tool). Firstly, the SWAT modeling was conducted for each river basin. After, the inter-basin transfer was established using SWAT reservoir operating parameters WURESN (Water Use Reservoir Withdrawn) and inlet function from Juam dam of Seomjin river basin to Gwangju stream of Yeongsan river basin respectively. Each river basin was calibrated and validated using 13 years (2005~2017) data of Seomjin- Juam dam reservoir storage (JAD), release, transfer and Yeongsan-Mareuk (MR) stream gauge station. The results of root mean square error RMSE, Nash-Sutcliffe efficiency NSE, and determination coefficient R2 of JAD were 2.22 mm/day, 0.62 and 0.86 respectively. The RMSE, NSE, and R2 of MR were 1.38 mm/day, 0.69 and 0.84 respectively. To evaluate the downstream effects by the transferred water, the water levels of 2 multi-function weirs (SCW, JSW) in Yeongsan river basin and the Gokseong (GS) and Gurye (GR) stream gauge stations in Seomjin river basin were also calibrated. The RMSE, NSE, and R2 of SCW, JSW, GS and GR were 1.49~2.49 mm/day, 0.45~0.76, 0.81~0.90 respectively.

Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography (조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가)

  • Gweon, Hye-Mi;Chung, Tae-Sub;Suh, Sang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • Purpose : To evaluate the cause of internal jugular vein (IJV) obstruction on contrast enhanced 3D MR angiography (CE-MRA) using contrast enhanced computed tomography (CE-CT). Materials and Methods : A total number of 30 patients were enrolled, who underwent both head and neck CE-MRA and CE-CT from 2005 to 2008. We defined obstruction group which had IJV obstruction and control group which had no IJV obstruction on CE-MRA. The following parameters were measured from axial images of CE-CT: 1) diameter of IJV; 2) distance between the styloid process and ipsilateral lateral mass of the atlas; 3) maximum area of lateral mass of the atlas. Each parameter was compared between obstruction group and control group. Results : The diameter of IJV and distance between the styloid process and lateral mass of the atlas at IJV obstruction side in obstruction group were $1.6{\pm}1.0\;mm$ and $4.1{\pm}2.1\;mm$ respectively, which resulted in statistical significance (p<0.01). The maximum area of lateral mass of the atlas at IJV obstruction side in obstruction group was $103.4{\pm}25.3\;mm^2$ which is significantly larger than in control group (p<0.05). Conclusion : We found that the cause of IJV obstruction on CE-MRA could be narrow space between the styloid process and the lateral mass of the atlas, which was related with asymmetric larger area of lateral mass of atlas.

Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

  • Lee, Jung-Woo;Choe, Bo-Young;Choi, Chi-Bong;Huh, Soon-Nyoung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.1
    • /
    • pp.48-60
    • /
    • 2005
  • Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-image of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators wes evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR image of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the image of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40~80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.

  • PDF

An experimental study for the prediction of combustion performance of the Unlike Impinging Quadlet Injector (충돌형 Quadlet 인젝터의 연소성능 예측에 관한 실험적 연구)

  • Kim, J.W.;Park, H.H.;Han, J.S.;Kim, S.J.;Kim, Y.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.44-50
    • /
    • 1999
  • For the prediction of combustion performance of the Unlike Impinging Quadlet Injector (OOOF type), mixing efficiency, mixing characteristic velocity, and efficiency of mixing characteristic velocity were obtained from the cold test. Water/kerosene were used for simulants, The momentum ratio of oxidizer and fuel were mixing correlating parameter. Orifice discharge coefficient, spray pattern and mass distribution were measured. As a result, invasion-depth had strong effect on mixing efficiency, mixing characteristic velocity, and efficiency of mixing characteristic velocity. Mixing efficiency and efficiency of mixing characteristic velocity showed maximum value for momentum ratio 1.67(TMR = 2.5), and fuel rich state showed larger decreasing ratio than oxidizer rich state.

  • PDF

A Study on the Effect Analysis Influenced on the Advanced System of Moving Object (이동물체가 정밀 시스템에 미치는 영항분석에 관한 연구)

  • Shin, Hyeon-Jae;Kim, Soo-In;Choi, In-Ho;Shon, Young-Woo;An, Young-Hwan;Kim, Dae-Wook;Lee, Jae-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.87-95
    • /
    • 2007
  • In this paper, we analyzed the mr detection and the stability of the object tracking system by an adaptive stereo object hacking using region-based MAD(Mean Absolute Difference) algorithm and the modified PID(Proportional Integral Derivative)-based pan/tilt controller. That is, in the proposed system, the location coordinates of the target object in the right and left images are extracted from the sequential stereo input image by applying a region-based MAD algorithm and the configuration parameter of the stereo camera, and then these values could effectively control to pan/tilt of the stereo camera under the noisy circumstances through the modified PID controller. Accordingly, an adaptive control effect of a moving object can be analyzed through the advanced system with the proposed 3D robot vision, in which the possibility of real-time implementation of the robot vision system is also confirmed.

Development of Self-Adaptive Meta-Heuristic Optimization Algorithm: Self-Adaptive Vision Correction Algorithm (자가 적응형 메타휴리스틱 최적화 알고리즘 개발: Self-Adaptive Vision Correction Algorithm)

  • Lee, Eui Hoon;Lee, Ho Min;Choi, Young Hwan;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.314-321
    • /
    • 2019
  • The Self-Adaptive Vision Correction Algorithm (SAVCA) developed in this study was suggested for improving usability by modifying four parameters (Modulation Transfer Function Rate, Astigmatic Rate, Astigmatic Factor and Compression Factor) except for Division Rate 1 and Division Rate 2 among six parameters in Vision Correction Algorithm (VCA). For verification, SAVCA was applied to two-dimensional mathematical benchmark functions (Six hump camel back / Easton and fenton) and 30-dimensional mathematical benchmark functions (Schwefel / Hyper sphere). It showed superior performance to other algorithms (Harmony Search, Water Cycle Algorithm, VCA, Genetic Algorithms with Floating-point representation, Shuffled Complex Evolution algorithm and Modified Shuffled Complex Evolution). Finally, SAVCA showed the best results in the engineering problem (speed reducer design). SAVCA, which has not been subjected to complicated parameter adjustment procedures, will be applicable in various fields.

Laplacian-Regularized Mean Apparent Propagator-MRI in Evaluating Corticospinal Tract Injury in Patients with Brain Glioma

  • Rifeng Jiang;Shaofan Jiang;Shiwei Song;Xiaoqiang Wei;Kaiji Deng;Zhongshuai Zhang;Yunjing Xue
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.759-769
    • /
    • 2021
  • Objective: To evaluate the application of laplacian-regularized mean apparent propagator (MAPL)-MRI to brain glioma-induced corticospinal tract (CST) injury. Materials and Methods: This study included 20 patients with glioma adjacent to the CST pathway who had undergone structural and diffusion MRI. The entire CSTs of the affected and healthy sides were reconstructed, and the peritumoral CSTs were manually segmented. The morphological characteristics of the CST (track number, average length, volume, displacement of the affected CST) were examined and the diffusion parameter values, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD), mean squared displacement (MSD), q-space inverse variance (QIV), return-to-origin probability (RTOP), return-to-axis probabilities (RTAP), and return-to-plane probabilities (RTPP) along the entire and peritumoral CSTs, were calculated. The entire and peritumoral CST characteristics of the affected and healthy sides as well as those relative CST characteristics of the patients with motor weakness and normal motor function were compared. Results: The track number, volume, MD, RD, MSD, QIV, RTAP, RTOP, and RTPP of the entire and peritumoral CSTs changed significantly for the affected side, whereas the AD and FA changed significantly only in the peritumoral CST (p < 0.05). In patients with motor weakness, the relative MSD of the entire CST, QIV of the entire and peritumoral CSTs, and the AD, MD, RD of the peritumoral CST were significantly higher, whereas the RTPP of the entire and peritumoral CSTs and the RTOP of the peritumoral CST were significantly lower than those in patients with normal motor function (p < 0.05 for all). In contrast, no significant changes were found in the CST morphological characteristics, FA, or RTAP (p > 0.05 for all). Conclusion: MAPL-MRI is an effective approach for evaluating microstructural changes after CST injury. Its sensitivity may improve when using the peritumoral CST features.

Classification of a Volumetric MRI Using Gibbs Distributions and a Line Model (깁스분포와 라인모델을 이용한 3차원 자기공명영상의 분류)

  • Junchul Chun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.58-66
    • /
    • 1998
  • Purpose : This paper introduces a new three dimensional magnetic Resonance Image classification which is based on Mar kov Random Field-Gibbs Random Field with a line model. Material and Methods : The performance of the Gibbs Classifier over a statistically heterogeneous image can be improved if the local stationary regions in the image are disassociated from each other through the mechanism of the interaction parameters defined at the local neighborhood level. This usually involves the construction of a line model for the image. In this paper we construct a line model for multisignature images based on the differential of the image which can provide an a priori estimate of the unobservable line field, which may lie in regions with significantly different statistics. the line model estimated from the original image data can in turn be used to alter the values of the interaction parameters of the Gibbs Classifier. Results : MRF-Gibbs classifier for volumetric MR images is developed under the condition that the domain of the image classification is $E^{3}$ space rather thatn the conventional $E^{2}$ space. Compared to context free classification, MRF-Gibbs classifier performed better in homogeneous and along boundaries since contextual information is used during the classification. Conclusion : We construct a line model for multisignature, multidimensional image and derive the interaction parameter for determining the energy function of MRF-Gibbs classifier.

  • PDF

Quantitative Evaluation of Regional Cerebral Blood Flow by Visual Stimulation in $^{99m}Tc-HMPAO$ Brain SPECT ($^{99m}Tc-HMPAO$ 뇌 SPECT에서 시각자극에 의한 국소 뇌 혈류변화의 정량적 검증)

  • Juh, Ra-Hyeong;Suh, Tae-Suk;Kwark, Chul-Eun;Choe, Bo-Young;Lee, Hyoung-Koo;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.166-176
    • /
    • 2002
  • Purpose: The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of $^{99m}Tc-HMPAO$ (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. Materials and Methods: The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and $^{99m}Tc-HMPAO$ SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the legion of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). Results: The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was $32.50{\pm}5.67%$. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Conclusion: Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.