• Title/Summary/Keyword: MR comparative study

Search Result 52, Processing Time 0.031 seconds

Response of Shewanella oneidensis MR-1 to Longterm Exposure with Toxic Ionic Liquid: Comparative Studies on MR-1 and SH-1, an Acclimated Strain (유독 이온성 액체의 장기 노출에 대한 Shewanella oneidensis MR-1의 반응: MR-1과 순응된 균주 SH-1의 비교 연구)

  • Han, Sang Hyun;Kang, Chang-Ho;Kwak, Dae Yung;Ha, Sung Ho;Koo, Yoon-Mo;So, Jae-Seong
    • KSBB Journal
    • /
    • v.28 no.2
    • /
    • pp.146-150
    • /
    • 2013
  • In this study, we investigated the effects of longterm exposure to ionic liquid (IL) on Shewanella oneidensis MR-1 (MR-1). MR1 was acclimated through repeated exposure to IL. The acclimated strain was named as S. oneidensis SH-1 (SH-1) and compared with MR-1 in various aspects including morphology, cell surface hydrophobicity (CSH), motility, and fatty acid. Compared to the MR-1, SH-1 showed elongated cell shape on scanning electron microscopy. Upon exposure to IL, hydrophobicity of SH-1 (28.2%) was higher that of MR-1 (3.3%). In contrast, motility of SH-1 (7 mm) was lower than that also of MR-1 (22 mm), and branched chain fatty acid of SH-1 was lower than that of MR-1, 27.6% and 41.1%, respectively.

A Study on Aspheric Optics Research for Improving the Luminous Efficiency of the LED MR16 (LED MR16의 광효율 향상을 위한 비구면 광학계 연구)

  • Yoo, Sook-Chul;Yoo, Kyung-Sun;Hyeon, Dong-Hun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.480-487
    • /
    • 2013
  • In this study, we researched the LED source MR16,which maintains the strong points of an ordinary MR16 while compensating for its weak points. The optical system composition of the LED MR16 includes four aspherical lens per sheet and a patterned reflector. The aspherical optical system and reflector were designed using optical software, and the performance was estimated using a lighting simulation program. Finally, a prototype was manufactured after analyzing the simulation data, and the reliability of the simulation results was estimated using a comparative analysis of the designed data and measured data.

A study on the scene directing and overacting character expressions in accordance with creating actual comedy movie into animation Focusing on TV animation Mr. Bean (희극적 실사의 애니메이션화에 따른 장면 연출과 캐릭터 과장연기 표현 연구 - TV애니메이션 Mr.bean을 중심으로)

  • Park, Sung-Won
    • Cartoon and Animation Studies
    • /
    • s.49
    • /
    • pp.143-167
    • /
    • 2017
  • The purpose of this study is to analyze the characteristics that appear when actual comedy movie is made into animation, from the singularities which arise from producing remake of existing media contents into animation. Animation and slapstick comedy movies possess a similarity in that they both evoke laughter from the viewer via exaggerated motion, expression and action. In the case of live action film, people must carry out the acting and there exists spatial limitations, whereas animation does not have such limits, which allows the comic animation to materialize spatial scene directing and acting which are different from that of live action comic films, despite the fact that they share elements of the same genre. Accordingly, this study performs comparative analysis of and which is based on the contents of the same event, from the English comedy TV program and the , the TV animation which is a remake animated version of the original series, to conduct comparative analysis the character acting and the scene directing in accordance with the live action movie and animation. The result of studying the point that makes it easy to create comic genre into animation and the advantages possessed by the media of animation, through analyzing two works that deal with the same character and the same event, were as follows. It was proven through the analysis that comedic directing with doubled composure and amusement is possible through the anticipation of exaggerated directing in the acting through expression and action, and diversity of the episodes with added imagination in the story, as well as the estrangement effect of the slapstick expression and etc.

Comparative Study on the Power Transfer Efficiency of Magnetic Resonance and Radio Frequency Wireless Power Transmission

  • Kim, Ye-Chan;Choi, Bo-Hee;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.232-234
    • /
    • 2016
  • In this paper, the power transfer efficiencies (PTEs) of magnetic resonance (MR) wireless power transmission (WPT) and radio frequency (RF) WPT are compared as a function of the distances between resonators (or antennas). The PTE of the C-loaded loop resonators during MR WPT was theoretically calculated and simulated at 6.78MHz, showing good agreement. The PTE of the patch antennas, whose area is the same as the C-loaded loop resonator during MR WPT, was theoretically calculated using the Friis equation and the equation by N. Shinohara and simulated at 5.8 GHz. The three results from the Friis equation, the equation by N. Shinohara, and from a full wave simulation are in strong agreement. The PTEs, when using the same size resonators and antennas are compared by considering the distance between the receiver and transmitter. The compared results show that the MR WPT PTE is higher than that of the RF WPT PTE when the distance (r) between the resonators (or antennas) is shorter. However, the RF WPT PTE is much higher than that of the MR WPT PTE when the distance (r) between the resonators (or antennas) is longer since the RF WPT PTE is proportional to $r^{-2}$ while the MR WPT PTE is proportional to $r^{-6}$.

A Study of the Hydraulic Circuit Model for a Magnetorheological Damper Analysis (MR 댐퍼 해석을 위한 유압회로 모델에 대한 연구)

  • Chang, Moon Suk;Byeon, Woo Jin;Kim, Soo Tae;An, Chae Hean
    • Journal of Drive and Control
    • /
    • v.14 no.1
    • /
    • pp.8-13
    • /
    • 2017
  • This paper proposes a hydraulic circuit for a Magnetorheological (MR) damper that can be used for semi-active and active controls. Methods are presented for obtaining reliable damping force displacement and velocity data, and hysteresis loop data corresponding to applied current. In order to get reliable data, analysis using electric and electronic software, a series of tests. and comparative evaluations are required. A hydraulic circuit model is proposed that can be applied to analyze a MR damper without any assumptions where the yield stress data according to the applied current are known. Analysis results of the proposed hydraulic circuit are confirmed by experimental results within acceptable tolerance. This hydraulic circuit model can be applied to various MR dampers and systems.

RADIOGRAPHIC COMPARATIVE STUDY OF FACIAL SKELETAL ASYMMETRY IN CRANIOMANDIBULAR DISORDER PATIENTS (두개하악장에 환자의 안면골 비대칭성에 관한 방사선사진상 비교분석)

  • Park Won-Kyl;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.291-304
    • /
    • 1994
  • The purpose of this study was to analyze the facial asymmetry of the patients with the craniomandibular disorder. In this study, 50 patients, who have joint clicking and pain, mouth opening limitation, and 40 dental students, Chosun University, who did not posses any restoration and orthodontic treatment, joint clicking and pain, mouth opening limitation, were selected as the control group. Both the control group and the patient group were takened skull P-A, submento-vertex radiogram by standized methods. After that, the deviation and facial asymmetry were measured and analyzed. The results of the this study were as follows: 1. In the Skull P-A radiogram, the width difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 3.35㎜, patient group were 4.51㎜ (P<0.05), the △Cg-Zy-Go: control group were 1.83㎜, patient group were 3.27㎜(P<0.001). 2. In the Skull P-A radiogram, the height difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 131.85㎜, patient group were 188.45㎜(P<0.05), the △Cg-Zy-Go: control group were 1.58㎜, patient group were 2.68㎜(P<0.00l). 3. In the Skull P-A radiogram, the area difference of control group and patient group measured that the △ Cg-Go-Cl: control group were 120.76㎟, patient group were 185.49㎟(P<0.05), the △Cg-Zy-Go: control group were 2.29㎟, patient group were 3.37㎟(p<0.05). 4. In the submento-vertex radiogram, the width difference of control group and patient group measured that the △Mr-Cl-Ia: control group were 1.50㎜, patient group were 2.35㎜(P<0.05), the △Mr-Cm-Ia: control group were 1.75㎜, patient group were 3.17㎜(P<0.05), the △Mr-Go-Ia: control group were 1.96㎜, patient group were 3.24㎜(P<0.001), the △Mr-Cp-Co: control group were 1.74㎜, patient group were 2.73㎜(P<0.05). 5. In the submento-vertex radiogram, the height difference of control group and patient group measured that the △Mr-Cp-Ia: control group were 1.68㎜, patient group were 2.46㎜P<0.05), the △Mr-CI-Ia: control group were 2.38㎜, patient group were 3.74㎜(P<0.05), the △Mr-Co-Ia: control group were 1.63㎜, patient group were 2.80㎜(P<0.05), the △Mr-Cm-Ia: control group were 1.45㎜, patient group were 3.12㎜(P<0.001). 6. In the submento-vertex radiogram, the area difference of control group and patient group measured that the △ Mr-Cp-Ia: control group were 73.17㎟, patient group were 110.16㎟(P<0.05), the △Mr-Cl-Ia: control group were 105.09㎟, patient group were 180.87㎟(P<0.001), the △Mr-Co-Ia: control group were 103.31㎟, patient group were 148.48㎟(P<0.05), the △Mr-Cm-Ia: control group were 97.01㎟, patient group were 167.83㎟(P<0.05), the △Mr-Go-Ia: control group were 104.24㎟, patient group were 205.90㎟(P<0.05).

  • PDF

Comparative Analysis between Directly Measured Diameter in 2D Angiography and Cross-Sectional Area-Converted Diameter in MR Image (2D 혈관조영술에서 직접 측정한 혈관 직경과 MR 영상에서 단면적 기반 환산 직경의 비교 분석)

  • Ki-Baek Lee;Mi-Hyeon Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.427-433
    • /
    • 2023
  • This study aimed to quantitatively compare the diameters measured directly from the coronal plane or sagittal plane of 2D digital subtraction angiography (DSA) and the cross-sectional area-converted diameters calculated from contrast-enhanced MR (CE-MR) imaging. A retrospective analysis was conducted on 20 patients who underwent both 2D DSA and CE-MR imaging. Firstly, the venous diameters of the superior sagittal sinus (SSS) and transverse sinus (TS) were directly measured from 2D DSA. Subsequently, the axial planes for SSS diameter and the sagittal plane for TS in CE-MR imaging were utilized to calculate cross-sectional area-based converted diameters. The numerical values obtained from 2D DSA and CE-MR imaging were compared pairwise at each location. For SSS, the diameter measured by 2D DSA was 27% larger than the conversion-based diameter from CE-MR imaging (9.8±1.4 mm vs. 7.1±1.3 mm, P<0.05). Similarly, for the right TS, the difference was 16% (8.8±3.2 mm vs. 7.4±2.0 mm, P<0.05), and for the left TS, the difference was 22% (8.4±2.8 mm vs. 6.6±1.3 mm, P<0.05). In conclusion, the diameter measured directly in conventional 2D DSA may be larger than the diameter converted based on the cross-sectional area. Therefore, when selecting the size of the stent, it is crucial to make precise determinations while keeping this fact in mind.

Identification of Breakdown Structure for Infrastructure Maintenance, Repair, and Rehabilitation Technologies using Comparative Case Study (비교사례 연구를 통한 인프라 유지관리 기술 분류체계 도출)

  • Kim, Du Yon;Cha, Yongwoon;Park, Wonyoung;Park, Taeil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.248-258
    • /
    • 2020
  • This study proposed a breakdown structure for maintenance and management technologies under the concept of comprehensive asset management at the life cycle level of infrastructure based on benchmarking with other developed countries. For this purpose, a comparative case study was performed to review and analyze the existing definitions and hierarchies for infrastructure maintenance, repair, and rehabilitation (MR&R) systems under major industrialized countries and South Korea. In accordance with the ratio of maintenance costs to GDP, the U.S., U.K, and Japan were selected to review their systems. The classifications and definitions of MR&R technologies under the laws were analyzed. The result showed that most developed countries differentiate maintenance and repair from improvement and constitute a system centered on preventive maintenance activities. On the other hand, Korea's system for facility management is not definitely classified and still focused on reactive structures, which need to be improved. In this study, as proposed, a breakdown structure established the concept of Maintenance and Management, Maintenance & Repair, and Performance Improvement. Consequently, this study could be used as the basis for the implementation of preventive MR&R activities and reasonable resource allocations from an asset management point of view.