• Title/Summary/Keyword: MR Image

Search Result 653, Processing Time 0.026 seconds

A Study on the Character Type and Image-telling in Drama (<미스터 션샤인>의 인물유형과 이미지텔링)

  • Jo, Mi-Sook
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.5
    • /
    • pp.73-85
    • /
    • 2020
  • This paper analyzes the types of characters in the drama by applying Gremas's Actantial model and Enneagram's character typology and examines how they are shaped. As the Korean Wave is important, it is necessary to study the type of characters and how to describe them. Character is the most important factor in the influence of drama. As a result of applying to the Actantial model, and the following results were obtained. The main subjects are Yu-jin Choi and Ko Ae-sin, the Helpers are many people helping the subject, the opponent is the pro-Japanese figures, the Sender is Gojong, and the recivers are the people of Joseon. Analysis results by personality type of Enneagram, it was found that the subjects are 3 and 5 type, the Helpers are various types, the opponent is 3 type, the Sender is 5 type, and the receivers all types. In the method of describing the subject, internal description (direct description) is used, and the other is only formed by indirect description. Some of the Helpers and the Sender are used an image-telling method to show the inside. However, the opponent is image-telling only to show indirectly. As a result, it was possible to confirm the differences and effects on the method of image-telling by character type.

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Evaluation of UTE Signal Acquisition Efficacy in Molecular MRI (분자 MR영상에서 UTE 신호의 효용성 평가)

  • Lee, Sang-Bock;Choi, Gui-Rack
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.305-311
    • /
    • 2012
  • This study compares the TE and UTE is to evaluate. We was programming by DWT of Matlab Tool-box for evaluation. M-program used feature value extract between TE Images and UTE Images. Two images using the extracted feature values were compared. Comparison of similar features two images phase was found to have value.

Comparison of Active Contour and Active Shape Approaches for Corpus Callosum Segmentation

  • Adiya, Enkhbolor;Izmantoko, Yonny S.;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.9
    • /
    • pp.1018-1030
    • /
    • 2013
  • The corpus callosum is the largest connective structure in the brain, and its shape and size are correlated to sex, age, brain growth and degeneration, handedness, musical ability, and neurological diseases. Manually segmenting the corpus callosum from brain magnetic resonance (MR) image is time consuming, error prone, and operator dependent. In this paper, two semi-automatic segmentation methods are present: the active contour model-based approach and the active shape model-based approach. We tested these methods on an MR image of the human brain and found that the active contour approach had better segmentation accuracy but was slower than the active shape approach.

Development of Image Post-processing System for the Cerebral Perfusion Information Mapping of MR Image (MR영상의 뇌관류 정보 Mapping을 위한 영상후처리 시스템개발)

  • 이상민;강경훈;장두봉;김광열;김영일;신태민
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • This paper works on development of an algorithm for mapping of cerebral perfusion parameters using the gamma-variate curve fitting. The signal intensity variate curve according to time measured in each pixel of perfusion MRI is nonlinear, and various hemodynamic parameters are not computed accurately. Levenberg-Marquardt algorithm(LMA), nonlinear optimum algorithm with high convergent speed and stability, is used to compute them. That is, the signal intensity variate curve is fitted by the gamma-variate function. Various hemodynamic parameters - Cerebral Blood Volume(C.B.V), Mean Transit Time(M.T.T), Cerebral Blood Flow(C.B.F), Time-to-Peak(T.T.P), Bolus Arrival Time(B.A.T), Maximum Slope(M.S) - are computed using LMA.

  • PDF

Neuroactivation studies using Functional Brain MRI (기능적 자기공명영상을 이용한 뇌활성화 연구)

  • Chung, Kyung-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.63-72
    • /
    • 2003
  • Functional MRI (fMRI) provides an indirect mapping of cerebral activity, based on the detection of the local blood flow and oxygenation changes following neuronal activity (Blood Oxygenation Level Dependent). fMRI allows us to study noninvasively the normal and pathological aspects of functional cortical organization. Each fMRI study compares two different states of activity. Echo-Planar Imaging is the technique that makes it possible to study the whole brain at a rapid pace. Activation maps are calculated from a statistical analysis of the local signal changes. fMRI is now becoming an essential tool in the neurofunctional evaluation of normal volunteers and many neurological patients as well as the reference method to image normal or pathologic functional brain organization.

Morphologic Assessment of Corpus Callosum in the Patient of Alzheimer Disease using Magnetic Resonance Imaging

  • Seoung, Youl-Hun;Choe, Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.13 no.2
    • /
    • pp.84-95
    • /
    • 2009
  • The purpose of this study was to evaluate the usefulness of the measurement of corpus callosum (CC) size in the Alzheimer patient by using magnetic resonance (MR) midsagittal image. We performed MR scanning in 20 normal high age group, and in 20 mild cognitive impairment (MCI) group, and in 20 Alzheimer disease (AD) group. The following parameters were employed in AD group: TRITE/FA 6650ms/66ms/$90^{\circ}$, NEX 2, Thickness/Gap 2/0, FOV 220mm. The magnetic field strength was used at 3.0 Tesla. We selected midsagittal image of the brain by using view forum program, measured CC size, which were anteroposterior length, diameter of genu, body, narrowing portion, and splenium. The present study demonstrates that CC size of Alzheimer disease can be useful for clinical assessment concerning the diameter of genu, body, and splenium.

Intramedullary Spinal Cord Lipoma Extending from the Cervicomedullary Junction to the Upper Thoracic Cord

  • Lee, Deok-Gu;Yoon, Seok-Mann;Shim, Jai-Joon;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.1
    • /
    • pp.71-73
    • /
    • 2005
  • A case of intramedullary spinal cord lipoma is presented. A one month-old male infant presented with irritability and weakness on his upper extremities. A magnetic resonance[MR] image of the cervical spine demonstrated a well defined, high signal intensity lesion on both T1 and T2-weighted MR images and suppression on the fat saturation sequence. The tumor mass extended from the foramen magnum to T2 vertebra level. Ventral displacement of the spinal cord with kinking of the cervico-medullary junction was evident on the T2-weighted sagittal image. Partial resection of the tumor mass through laminoplastic laminotomy from C1 to T2 resulted in improved motor weakness on his upper extremities.

Usefulness of Superparamagnetic Iron Oxide (SPIO) as a Negative Oral Contrast Agent in MR Cholangiopancreatography (자기공명 담관췌장초영술에서 음성 경구 조영제로 사용한 초상자성 산화철 제재의 유용성)

  • 이정민;송원규;이종덕
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.49-56
    • /
    • 2001
  • Purpose : To evaluate value of superparamagnetic iron oxide (SPIO) as a negative oral contrast agent in MR cholangiopancreatography (MRCP). Materials and methods : Forty-eight patients with suspected biliary tract or pancreatic diseases and six healthy volunteers were enrolled in this study. All MR images were obtained using a 1.5 T MR unit. MR-CP using fat-suppressed half-Fourier acquisition single-shot turbo spin echo (HASTE) and turbo spin echo (TSE) techniques were performed and reconstructed with maximal intensity projection (MIP). To determine the most optimal concentration of SPIO to obliterate the high signal intensity of water, a phantom experiment was conducted with various concentrations of SPIO-water mixture. Two radiologists evaluated pre- and postcontrast MRCPS. The contrast enhancement was assessed on the basis of loss of signal intensity in the stomach and duodenum. Results : In the phantom experiment, a significant increase of percentage of signal intensity loss (PSIL) occurred in concentration of 22.4 ugFe/ml (Feridex1 ml diluted with water 500 ml). Postcontrast MRCP showed an improved image quality compared with precontrast images. The rate of improvement in the diagnosis of diseases of the common bile duct and pancreatic duct was 25% (12/48). Conclusion : In patients with suspected biliary tract and pancreatic diseases, the SPIO is useful as a negative oral contrast agent for MRCP and provides an improvement of image quality.

  • PDF