• Title/Summary/Keyword: MR Image

Search Result 652, Processing Time 0.027 seconds

Extended JPEG Progressive Coding for Medical Image Archiving and Communication (확장 JPEG 표준을 이용한 점진식 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yeon
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.175-182
    • /
    • 1994
  • The international standard for digital compression and coding of continuous-tone still image known as JPEG (Joint Photographic Experts Group) standard is investigated for medical image archiving and communication. The JPEG standard has widely been accepted in the areas of electronic image communication, computer graphics, and multimedia applications, however, due to the lossy character of the JPEG compression its application to the field of medical imaging has been limited. In this paper, the JPEG standard is investigated for medical image compression with a series of head sections of magnetic resonance (MR) images (256 and 4096 graylevels, $256 {\times}256$size). Two types of Huffman codes are employed, i. e., one is optimized to the image statistics to be encoded and the other is a predetermined code, and their coding efficiencies are examined. From experiments, compression ratios of higher than 15 were obtained for the MR images without noticeable distortion. Error signal in the reconstructed images by the JPEG standard appears close to random noise. Compared to existing full-frame bit-allocation technique used for radiological image compression, the JPEG standard achieves higher compression with less Gibb's artifact. Feature of the progressive image build-up of the JPEG progressive coding may be useful in remote diognosis when data is transmitted through slow public communication channel.

  • PDF

Noisy Image Segmentation via Swarm-based Possibilistic C-means

  • Yu, Jeongmin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.35-41
    • /
    • 2018
  • In this paper, we propose a swarm-based possibilistic c-means(PCM) algorithm in order to overcome the problems of PCM, which are sensitiveness of clustering performance due to initial cluster center's values and producing coincident or close clusters. To settle the former problem of PCM, we adopt a swam-based global optimization method which can be provided the optimal initial cluster centers. Furthermore, to settle the latter problem of PCM, we design an adaptive thresholding model based on the optimized cluster centers that yields preliminary clustered and un-clustered dataset. The preliminary clustered dataset plays a role of preventing coincident or close clusters and the un-clustered dataset is lastly clustered by PCM. From the experiment, the proposed method obtains a better performance than other PCM algorithms on a simulated magnetic resonance(MR) brain image dataset which is corrupted by various noises and bias-fields.

Optimal Shoulder Position for Visualization of SLAP Ⅱ lesion on MR-Arthrography (SLAP Ⅱ 병변의 진단을 위한 관절 조영 자기 공명 영상에서 견관절 위치에 따른 비교)

  • Lee Young-Soo;Shin Dong-Bae;Park Soo-Jin;Kim Jin-Yong;Kim Hee-Sang;Ha Du-Hae
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.2
    • /
    • pp.95-101
    • /
    • 2000
  • Purpose : The purpose of this study was to evaluate the efficacy of oblique coronal MR images, oblique axial images of neutral, internal rotation and external rotation positions in the diagnosis of SLAP Ⅱ lesion. Materials and Methods: MR arthrography of the glenohumeral joint was evaluated retrospectively in 16 patients(16 shoulders) who underwent arthroscopic surgery(mean age; 38 years old, Male; 13, Female; 3). Oblique coronal fat-suppressed Tl-weighted spin echo images were performed with each shoulder in the neutral position of the arm and oblique axial images were performed in neutral, internal and external rotations of the arm respectively. The preoperative findings of MR were classified as definite tear, possible tear and no tear. Arthroscopic findings were correlated with MR findings of several different position of the arm. Results: Arthroscopic surgery revealed 8 SLAP Ⅱ lesion, 2 SLAP I lesion, and 6 normal superior labrum respectively. The accuracy of diagnosis in the 8 SLAP Ⅱ lesion were high on oblique axial image in external rotation which were interpreted as 8 definite tear, to compare with oblique axial images in neutral position which were interpreted as 4 definite tear, 3 possible tear, 1 no tear. The 6 normal superior labrum lesion were interpreted as no tear in all three position. The 2 SLAP I lesion were interpreted as 1 definite tear, 1 no tear on oblique axial image in neutral position and 1 definite tear, 1 possible tear on oblique axial image in external rotation. Conclusion: This study showed that axial MR images in external rotation of the arm combined with oblique coronal images have proved to be effective to detect SLAP Ⅱ lesion, and should be considered in imaging protocol for MR arthrography of the SLAP Ⅱ lesion.

  • PDF

Analysis of skin movement using MR images (자기공명 영상을 이용한 피부 움직임 분석에 관한 연구)

  • ;Natsuki Miyata;Makiko Kouchi;Masaaki Mochimaru
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.719-722
    • /
    • 2003
  • This paper describes a novel experiment that measures the skin movement of a hand based on MR (magnetic resonance) images in conjunction with surface modeling techniques. The proposed approach consists of 3 phases: (1) MR scanning of a hand with surface makers, (2) 3D reconstruction from the MR images. and (3) registration of the 3D models. The results of registration are used to trace the skin movement with respect to underlying bone motions by measuring the positions of the surface markers.

  • PDF

Individual approach in the recanalization treatment of the acute ischemic brain stroke according to the various MR findings in hyperacute stage

  • Y. Jang;Lee, D.;Kim, H.;Lee, J.;Park, C.G.;Lee, H.K.;Kim, S.;D. Suh
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.98-98
    • /
    • 2003
  • We will present various MR findings of hyperacute ischemic stroke with our own experiences in the management of the patients according to the findings. 대상 및 방법: A total of 441 patients were underwent 'acute stroke MR' imaging protocol between Mar. 2001 and Jun. 2003. The protocol included initial T2-weighted image (WI), diffusion WI (DWI, b=2000), time-of-flight (TOF) MR angiography (MRA), and pefusion WI(PWI), and follow-up T2WI, DWI, TOF MRA, and neck vessel contrast-enhanced MRA obtained three to five days after the insult. Among them, we retrospectively reviewed the MR findings and clinical courses of 193 patients with anterior circulation territorial infarction. Those ICA and MCA lesions were divided into six and five groups respectively according to the level and mechanism of the occlusion. PWI findings can be another factor in the management planning.

  • PDF

Modified Fermi Filter Design to Improve the MR Image of Knee in the Rheumatoid Arthritis Patient (류마티스 관절염 환자의 무릎 MR 영상 개선을 위한 변형된 Fermi 필터 설계)

  • Kim, Dong-Hyun;Ye, Soo-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.820-825
    • /
    • 2010
  • In this study, we intended to design the optimal Fermi filter to apply the k-space date that is knee image of the rheumatoid arthritis patient acquired from the MRI (magnetic resonance imaging) instrument. After deciding the suitable coefficient for the Fermi filter, the results were compared with modified Fermi filter and inverse Chebyshev filter, Chebyshev filter, Elliptic filter and Butterworth filter. Firstly, in comparison to the results, the radiologist confirmed that modified Fermi filter was best decision for boundary of the rheumatoid arthritis images. The number of the black voxels of the histogram showed the quantity of the results. At the proposed filter images, numbers of the blacks voxels were statistically decreased. That meant voxels only appeared the black color were changed to others voxels color. Because the number of the total voxels was fixed, the area appeared block color could be effected to the other areas. If the modified Fermi filter were used for rheumatoid arthritis patient, the result will be better than other filters.

Development and evaluation of MR compatible patch antenna for hyperthermia (온열치료를 위한 MR호환 평판가열안테나 개발 및 성능평가)

  • Kim, D.H.;Chun, S.I.;Jang, M.Y.;Yoon, M.S.;Kim, Y.B.;Jung, B.D.;Nam, S.H.;Mun, C.W.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.17-21
    • /
    • 2009
  • The thermal treatment have been combined with MRI which is able to acquire both an anatomical image with high-contrast and a thermal image, and have recently used for removing the tumor effectively. This study is to make a patch antenna which is designed to operate at 2.45GHz that has compatibility with MRI. The characteristic and specific absorption rate(SAR) were confirmed using computer simulation and confirmed a possibility of hyperthermia by performing experiment.

  • PDF

Fully Automatic Segmentation and Volumetry on Brain MRI of Coronal Section

  • Sung, Yun-Chang;Song, Chang-Jun;Noh, Seung-Moo;Park, Jong-Won
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.441-445
    • /
    • 2000
  • This study is to segment white matter, gray matter, and cerebrospinal fluid(CSF) on a brain MR image of coronal section and to calculate the volume of each. First, we segmented the whole region of a brain from a black colored background, a skull and a fat layer. Then, we calculated the partial volume of each component, which was present in scanning finite thickness, with the arithmetical analysis of gray value from the internal region of a brain showing the blurring effects on the basis of the MR image forming principle. Calculated partial volumes of white matter, gray matter and CSF were used to determine the threshold for the segmentation of each component on a brain MR image showing the blurring effects. Finally, the volumes of segmented white matter, gray matter, and CSF were calculated. The result of this study can be used as the objective diagnostic method to determine the degree of brain atrophy of patients who have neurodegenertive diseases such as Alzheimer’s disease and cerebral palsy.

  • PDF

Effective Gray-white Matter Segmentation Method based on Physical Contrast Enhancement in an MR Brain Images (MR 뇌 영상에서 물리기반 영상 개선 작업을 통한 효율적인 회백질 경계 검출 방법)

  • Eun, Sung-Jong;Whangbo, Taeg-Keun
    • Journal of Digital Contents Society
    • /
    • v.14 no.2
    • /
    • pp.275-282
    • /
    • 2013
  • In medical image processing field, object recognition is usually carried out by computerized processing of various input information such as brightness, shape, and pattern. If the information mentioned does not make sense, however, many limitations could occur with object recognition during computer processing. Therefore, this paper suggests effective object recognition method based on the magnetic resonance (MR) theory to resolve the basic limitations in computer processing. We propose the efficient method of robust gray-white matter segmentation by texture analysis through the Susceptibility Weighted Imaging (SWI) for contrast enhancement. As a result, an average area difference of 5.2%, which was higher than the accuracy of conventional region segmentation algorithm, was obtained.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF