• Title/Summary/Keyword: MR Head

Search Result 178, Processing Time 0.019 seconds

The evaluation of usefulness of the newly manufactured immobilization device (치료보조기구의 제작 및 유용성 평가)

  • Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.

  • PDF

Segmentation and Visualization of Head MR Image Based on Structural Approach (구조적인 기법을 이용한 머리 MR 단층 영상의 조직 분류 및 가시화)

  • 권오봉;김민기
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.283-290
    • /
    • 1999
  • Because MR(Magnetic Resonance) slice images have much information of functions about body organs, it is very effeclive for diagnoses lo analyze and visualize MR slice images. A visuahzation process is composed of medical image acquisition, preprocessmg, segmentation, inlerpolation, rendering. Segmentation and interpolation among thenl ,1re currenl hot topics because of MR slice image imperfections. This paper proposes a method for segmentalion, mlerpolation respectively and addresses 3 D-visualizmg of a head. We segmented head tissues uomg otructural knowledge of head studied by clinical experiments sequentially. We improved the dynamic elastic inlerpolation to Utilize in concave conlour. We compared the proposed segmentation method and the interpolation method with other methods.

  • PDF

Extraction of Brain Boundary and Direct Volume Rendering of MRI Human Head Data (MR머리 영상의 뇌 경계선 추출 및 디렉트 볼륨 렌더링)

  • Song, Ju-Whan;Gwun, Ou-Bong;Lee, Kun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.6
    • /
    • pp.705-716
    • /
    • 2002
  • This paper proposes a method which visualizes MRI head data in 3 dimensions with direct volume rendering. Though surface rendering is usually used for MRI data visualization, it has some limits of displaying little speckles because it loses the information of the speckles in the surfaces while acquiring the information. Direct volume rendering has ability of displaying little speckles, but it doesn't treat MRI data because of the data features of MRI. In this paper, we try to visualize MRI head data in 3 dimensions as follows. First, we separate the brain region from the head region of MRI head data, next increase the pixel level of the brain region, then combine the brain region with the increased pixel level and the head region without brain region, last visualizes the combined MRI head data with direct volume rendering. We segment the brain region from head region based on histogram threshold, morphology operations and snakes algorithm. The proposed segmentation method shows 91~95% similarity with a hand segmentation. The method rather clearly visualizes the organs of the head in 3 dimensions.

Clinical Usefulness of MR FLAIR Image in Mild Head Injuries (경증 두부외상 환자에서 MR FLAIR 영상의 임상적 유용성)

  • Kim, Sei-Yoon;Whang, Kum;Kim, Hun-Joo;Lee, Myoung-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1182-1186
    • /
    • 2001
  • Objectives : MR fluid-attenuated inversion recovery(FLAIR) image uses paired long inversion time and relaxation time that nulls the signal from CSF. With nulling of the CSF long echo time readout could be used to increase T2-weighting, hence improving the conspicuousness of most tissue lesions without the deleterious effects of CSF artifact seen on T2 weighted sequence. We examed the usefulness of FALIR image in the diagnosis of mild head injury. Methods : A total of 38 patients with mild head injury were examined by FLAIR image. We compared those images with CT scan and T1, T2-weighted images. Careful observation of MR images were done by two well-trained neuroradiologists. Each image was compared for conspicuousness and detectability of traumatic lesions might have shown abnormal signal intensities. The Wilcoxon signed ranks test was used for statistical evaluation. Results : The FLAIR image was significantly more sensitive than those of other images(p<0.001). T2 FFE(Fast Field Echo) image was more useful for detection of small petechial hemorrhages. Conclusion : FLAIR image is considered to be more sensitive than those of conventional MR images in the evaluation of mild head injuries.

  • PDF

Sensitivity and Rejection Capability of Thermal Asperity Induced by Sub-Micron Contamination Particles (미세 입자에 의한 thermal asperity의 민감도 해석 및 감소 방안)

  • 좌성훈
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.6
    • /
    • pp.310-317
    • /
    • 2000
  • With use of (G)MR head, thermal asperity (TA) has been a big concern in drive industry. In this study, we investigated several factors of heads and disks which affects the TA sensitivity of the drive. TA experiments were conducted by introducing the particles on the drives using a particle injection chamber. It was found that the slider ABS shape can help to reduce TA or contamination in the head/media interface. However, TA sensitivity of the drive mainly depend on the intrinsic property of (G)MR sensor. GMR head is much less sensitive to TA compared with MR head. However, in case that the same bias current was applied for both of MR and GMR head, TA sensitivity of GMR head became almost identical to that of MR head. Therefore it was found that the bias current is a dominant factor in determining TA sensitivity of the head. TA sensitivity of different types of disks was also studied. The scratch resistance of the carbon overcoat layer is the one of the main factors which influence TA rejection capability of the disks.

  • PDF

Optimization of Flip Angle at Head & Neck MR Angiography using Gadoteridol (Gadoteridol을 이용한 Head & Neck MR Angiography에서의 적정 Flip Angle)

  • Jeong, Hyunkeun;Kim, Mingi;Song, Jaejun;Nam, Kichang;Choi, Hyunsung;Jeong, Hyundo;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.151-159
    • /
    • 2016
  • In this research, we tried to suggest moderate FA(Flip Angle) for CE(Contrast Enhnaced)-Head&Neck MR Angiography with Gadoteridol. For this study, we did test MR phantom and clinical study according to FA change. After that, quantitative analysis was progressed. The results of MR phantom study were as follow: RSP(Reaction Starting Point)was recorded within 300~400 mmol. MPSI(Max Peak Signal Intensity) was 2,086, 3,705, 5,109, 6,194, 7.096, 7,192 [a.u]. MPP(Max Peak Point) was shown at 30, 50, 50, 40, 50, 40 mmol. IRMPSI(Increase Rate of MPSI) was 77.6%, 37.9%, 21.2%, 14.6%, 1.4% as increasing of FA. The results of clinical study were as follow SICB(Signal Intensity of Carotid artery Bifurcation) was recorded respectively 392.5, 4165.2, 4270, 3502.2, 3263.7, 3119.6 [a.u]. ORA(Occurence Rate of Artifact) was increased as 0, 0, 20, 40, 50, 70%. According to this research, we are not only able to assure that increase of FA can be effect on H1 spin's SI(Signal Intensity) which was combined with gadolinium agent, but also be effect on artifact rate in blood vessel. In clinical field, we expect that CE-Head&Neck MR Angiography can be performed in a practical way with this research.

Micromagnetic Modeling of Spin-valve MR Head with Synthetic Antiferromagnet (SyAF)

  • Tahk, Y.W;Lee, K.J;Lee, T.D
    • Journal of Magnetics
    • /
    • v.7 no.2
    • /
    • pp.55-58
    • /
    • 2002
  • MR transfer behaviors of the permanent magnet biased spin valve MR sensors with SyAF (synthetic antiferromagnet) layers were studied by micromagnetics modeling. For narrow track MR heads, various height to width ratios were considered together with strength of permanent magnets which stabilities the free layed As the MR sensor width is reduced to $0.12 \mu{m}$, sensor height less than 0.09 ${\mu}{\textrm}{m}$ is needed to show good linearity and the Mr.t of permanent magnets smaller than 0.2 memu/$cm^2$ is sufficient for the domain stabilization. The conditions for single domain behavior of the free layer were also investigated through optimizing the biasing strength of permanent magneto the shield gap and the aspect ratio of MR sensor.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Major Characteristics Affecting the Sensory Quality of Rice Marketed in Korea

  • Jang, Eun-Hee;Kim, Qui-Woung;Kim, Hoon;Kim, Dong-Chul;Lee, Se-Eun;Kim, Sang-Sook
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.66-71
    • /
    • 2008
  • A total of 284 milled rice (MR) marketed in Korea were analyzed for grading characteristics (head rice, broken kernels, chalky kernels, and damaged kernels%), color characteristics (L-, a-, b-values, and whiteness), protein content (%), and the cooked rice (CR) sensory quality to investigate the key characteristics affecting the overall sensory quality of rice marketed in Korea. Relatively high correlation with the overall sensory quality of the CR was found in color characteristics such b-value of the CR (r=-0.779) and MR (r=-0.545), the a-value of the CR (r=0.513), and the whiteness (r=0.298) of the MR, compared to protein (r=-0.150), and the moisture (r=0.158) contents of the MR and the percentage of head rice (r=0.195). Partial least squares (PLS) regression of the CR b-value with various characteristics of the MR showed that CR b-value was increased with MR b-value effectively, followed by protein content, damaged kernels, chalky kernels, and colored kernels of MR while it was decreased with whiteness and moisture content for the MR.

Extraction of the Femoral Heads in MR Images and Measurement of the Parameters for the Diagnosis of the Avascular Necrosis (MR 영상에서 대퇴골두 영역의 추출과 무혈성 괴사의 진단에 필요한 인자의 측정)

  • Lee, Kyung-Su;Lee, Sung-Kee
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.8
    • /
    • pp.846-854
    • /
    • 2000
  • In this paper, we propose effecient methods to extract the femoral head region in MR images. The femoral head area in MRI is approximated using Hough transform and the anatomical features of the femoral heads. Then, modified region growing method is applied to extract the femoral head region. We measured the parameters for the diagnosis of the avascular necrosis of the femoral heads from the segmented femoral head region. The proposed methods are proved very effective to extract the femoral head of healthy volunteer and of the patient having heavy avascular necrosis. The measured parameters can be used very efficiently for the quantitative analysis and the diagnosis of the avascular necrosis of the femoral heads.

  • PDF