• Title/Summary/Keyword: MR, experimental

Search Result 293, Processing Time 0.03 seconds

Design Analysis and Experimental Evaluation of an MR Fluid Clutch (자기장 및 유동 해석을 이용한 자기유변 클러치의 성능 예측 및 검증)

  • Lee, U-Seop;Kim, Tae-Gyun;Heo, Nam-Geon;Jeon, Do-Yeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.2143-2150
    • /
    • 2000
  • An MRC(Magneto-rheological Clutch) has a great potential of application because of its good transmissibility, little wear-out and fast response to electrical control signal. Though many MRCs have been developed for years, there has not been an research on the method to predict the performance of MRC except the simplified mathematical models. But the simplified mathematical models do not fit well since their performance has close relations with shapes of clutches and viscosity distribution throughout the fluids caused by applied magnetic fields. in this study, the CFD and FEM analyses were applied to various shape of MRC and the methods were examined in experiments.

Hyperpolarization: Sensitivity Boost in Magnetic Resonance Spectroscopy and Imaging

  • Ko, Hyeji;Gong, Gyeonghyeon;Jeong, Gijin;Choi, Ikjang;Seo, Hyeonglim;Lee, Youngbok
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Hyperpolarization methods are the most emerging techniques in the field of magnetic resonance (MR) researches since they make a contribution to overcoming sensitivity limitation of MR spectroscopy and imaging, leading to new fields of researches, real-time in vivo metabolic/molecular imaging and MR analysis of chemical/biological reactions in non-equilibrium conditions. Make use of enormous signal enrichments, it becomes feasible to investigate various chemical and biochemical systems with low ${\gamma}$ nuclei in real-time. This review deals with the theoretical principals of common hyperpolarization methods and their experimental features. In addition, more detailed theories, mechanisms, and applications of dissolution dynamic nuclear polarization (D-DNP) are discussed.

Experimental Evaluation on Shear Modulus of MRE due to MRP Coating and Induced Current (Magnetic Reactive Particle 코팅 및 인가전류에 따른 Magnetorheological Elastomer 의 전단계수 측정)

  • Oh, Jae-Eung;Jeong, Un-Chang;Kim, Jin-Su;Yoon, Jung-Min;Roh, Jeong-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.927-929
    • /
    • 2014
  • MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation). Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced current. As induced magnetic field intensity increased and coated with MRP, increment of MR effect was observed.

  • PDF

Improvement of SNR in DANTE Fast MR Imaging (MR DANTE 고속 영상에서 SNR의 개선에 관한 연구)

  • 정성택
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.87-96
    • /
    • 1997
  • A pixel profile in the conventional DANTE sequence is so poor that the excited area by DANTE sequence is a small portion of a pixel. This causes poor signal to noise ratio in DANTE image. In this paper, a frequency modulated(FM) DANTE imaging sequence is proposed to improve pixel profile in DANTE image. A DANTE pulse train is shaped by an FM function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on the sweep in FM signal. Computer simulations and experimental result obtained using a 7.0 T NMR imaging system are presented.

  • PDF

The controllable damper for micro vibration suppression (미세 진동 흡수를 위한 가변형 댐퍼)

  • Kim, Ki-Duck;Sim, Won-Chul;Jeon, Do-Young;Choi, Bum-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3289-3291
    • /
    • 1999
  • The vibration and impact hinders the movement of micro dynamic system. The controllable micro damper is a solution for this problem. In this paper, the controllable micro damper for MR(Magneto - Rheological) Fluid is designed and fabricated using bulk micromachining process and organic bonding technique. The damping constant of micro MR damper changes according to input magnetic field. The response of the micro MR damper is measured and the experimental results are compared.

  • PDF

A Variational Model For Longitudinal Brain Tissue Segmentation

  • Tang, Mingjun;Chen, Renwen;You, Zijuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.11
    • /
    • pp.3479-3492
    • /
    • 2022
  • Longitudinal quantification of brain changes due to development, aging or disease plays an important role in the filed of personalized-medicine applications. However, due to the temporal variability in shape and different imaging equipment and parameters, estimating anatomical changes in longitudinal studies is significantly challenging. In this paper, a longitudinal Magnetic Resonance(MR) brain image segmentation algorithm proposed by combining intensity information and anisotropic smoothness term which contain a spatial smoothness constraint and longitudinal consistent constraint into a variational framework. The minimization of the proposed energy functional is strictly and effectively derived from a fast optimization algorithm. A large number of experimental results show that the proposed method can guarantee segmentation accuracy and longitudinal consistency in both simulated and real longitudinal MR brain images for analysis of anatomical changes over time.

The Detection of Intracranial Calcification by MR : Experimental Model (실험적 모델을 이용한 자기공명영상에서 석회화의 인지)

  • 박승진
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.3-12
    • /
    • 1994
  • Purporse : It is known that detection of calcification by MRI is difficulty in intracranial calcified lesions, but author tried to evaluate the signal intensity image of calcification by MR with experimental model. Subjects & Methods : Author analyzed and compared with values of calcium carbonate and hydroxyapatite phantoms by each concentration (10, 20, 30, 40, 50%) and size(1-10mm), measured ROI attenuating from CT and MRI(TlWI & T2WI). Results : The high concentration of calcium carbonate is, the lower the signal intensity of calcium carbonate phantom is both T1 & T2WI. For concentration of Hydroxyapatite of up to 30% by weight the signal intensity on standard T1 weighted images increased but subsequently decreased. Hyperintensity does not preclude calcification as a cause of the signal alteration-an observation that all radiologists interpreting MR images need to be aware of. Conclusion: The signal intensity of intracranial calcification is various on MR imaging in concerning with components, concentration, & size of calcification, and especially high signal intensity of intracranial calcification noted differencial diagnosis.

  • PDF

Analysis of Control Performance in Gap Size of MR Damper (MR Damper의 Gap Size에 따른 제어성능 분석)

  • Heo, Gwang Hee;Jeon, Seung Gon;Seo, Sang Gu;Kim, Dae Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.41-50
    • /
    • 2021
  • In this study, the flow path width (Gap Size), which is the flow path of fluid, was selected differently among various factors that determine the Ccontrol Force of MR damper, and the change of Control Force was confirmed accordingly. For this purpose, two MR dampers with a Gap Size of 1.0mm and 1.5mm were fabricated, respectively, and dynamic load experiments were conducted according to changes in applied current and vibration conditions The experimental results showed that the minimum Control Force was 3.2 times higher than 1.5mm in the case of 1.0mm Gap Size, and the maximum Control Force was 2.3 times higher than 1.5mm in the case of 1.0mm Gap Size. In addition, the increased width of the Control Force according to applied current was 34N for Gap Size 1.0mm, and 12.7N for Gap Size 1.5mm. As the gap Size increased, the overall Control Force and the increase in the Control Force by the applied current decreased. Next, the dynamic range, which is a performance evaluation index of the semi-active Control device, was 2.3 on average under 1.0mm condition and 2.8 on average under 1.5mm condition, confirming the possibility of utilization as a semi-active Control device.

Effect of asymmetric magnetic fields on the interface shape in Czochralski silicon crystals (Cz 실리콘 단결정에서 비대칭 자기장이 고액 계면에 미치는 영향)

  • Hong, Young-Ho;Shim, Kwang-Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.4
    • /
    • pp.140-145
    • /
    • 2008
  • Silicon single crystals are grown by Czochralski (CZ) method in different growing conditions. The different shapes of the crystal-melt interface are obtained with various magnetic fields. Effects of zero-Gauss plane (ZGP) shape and magnetic intensity (MI) on the crystal-melt interface in the crystal experimentally are investigated. The shape of ZGP is not only flat but also parabolic, which is due to magnetic ratio (MR) of the lower to upper current densities in the configurations of the cusp-magnetic fields. As the MR increases, the crystal-melt interface becomes more concave. It means that the hot melt can be easily transported to the crystal-melt interface with increasing the MR. Effective shape of the crystal-melt interface is found to depend on the magnetic field in cusp-magnetic CZ method. The experimental results are compared with other studies and discussed.

Automatic Segmentation of the meniscus based on Active Shape Model in MR Images through Interpolated Shape Information (MR 영상에서 중간형상정보 생성을 통한 활성형상모델 기반 반월상 연골 자동 분할)

  • Kim, Min-Jung;Yoo, Ji-Hyun;Hong, Helen
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1096-1100
    • /
    • 2010
  • In this paper, we propose an automatic segmentation of the meniscus based on active shape model using interpolated shape information in MR images. First, the statistical shape model of meniscus is constructed to reflect the shape variation in the training set. Second, the generation technique of interpolated shape information by using the weight according to shape similarity is proposed to robustly segment the meniscus with large variation. Finally, the automatic meniscus segmentation is performed through the active shape model fitting. For the evaluation of our method, we performed the visual inspection, accuracy measure and processing time. For accuracy evaluation, the average distance difference between automatic segmentation and semi-automatic segmentation are calculated and visualized by color-coded mapping. Experimental results show that the average distance difference was $0.54{\pm}0.16mm$ in medial meniscus and $0.73{\pm}0.39mm$ in lateral meniscus. The total processing time was 4.87 seconds on average.