• Title/Summary/Keyword: MR, experimental

Search Result 292, Processing Time 0.029 seconds

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

A semi-active mass damping system for low- and mid-rise buildings

  • Lin, Pei-Yang;Lin, Tzu-Kang;Hwang, Jenn-Shin
    • Earthquakes and Structures
    • /
    • v.4 no.1
    • /
    • pp.63-84
    • /
    • 2013
  • A semi-active mass damping (SMD) system with magnetorheological (MR) dampers focusing on low- and mid-rise buildings is proposed in this paper. The main purpose of this study is to integrate the reliable characteristics of the traditional tuned mass damper (TMD) and the superior performance of the active mass damper (AMD) to the new system. In addition, the commonly seen solution of deploying dense seismic dampers throughout the structure nowadays to protect the main structure is also expected to switch to the developed SMD system on the roof with a similar reduction performance. In order to demonstrate this concept, a full-size three-story steel building representing a typical mid-rise building was used as the benchmark structure to verify its performance in real life. A numerical model with the interpolation technique integrated was first established to accurately predict the behavior of the MR dampers. The success of the method was proven through a performance test of the designated MR damper used in this research. With the support of the MR damper model, a specific control algorithm using a continuous-optimal control concept was then developed to protect the main structure while the response of the semi-active mass damper is discarded. The theoretical analysis and the experimental verification from a shaking table test both demonstrated the superior mitigation ability of the method. The proposed SMD system has been demonstrated to be readily implemented in practice.

MR Imaging and Histological Findings of Experimental Cerebral Fat Embolism in Cats

  • Park Byung-Rae;Ko Seong-Jin;Kim Hwa-Gon
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.285-291
    • /
    • 2004
  • To determine the magnetic resonance (MR) imaging findings and natural history of cerebral fat embolism in a cat model, and to correlate the MR imaging and histologic fmdings. Intemel carotid artery of 11 cats was injected with 0.1 ml of triolein. T2-weighted, T1-weighted and Gd-enhanced T1-weighted images were obtained serially for 2 hours, 1 days, 4 days, 1 week, 2 weeks and 3 weeks after embolization. Any abnormal signal intensity was evaluated. After MR imaging at 3 weeks, brain tissue was obtained for light microscopic (LM) examination using hematoxylin-eosin (HE) and Luxol fast blue staining, and for electron microscopic examination. The LM examination with HE staining revealed normal histological findings in the greater part of an embolized lesion. Cystic change was observed in the gray matter of 8 cats, while in the gray and white matter of 3 cats. At LM examination, Luxol fast blue, staining demonstrated demyelination around the cystic change occurring in the white matter, and EM examination of the embolized cortex revealed sporadic intracapillary fat vacuoles (n=11) and disruption of the blood-brain barrier (n=4). Most lesions were normal, however, and perivascular interstitial edema and cellular swelling were mild compared with the control side. The greater part of an embolized lesion showed reversible findings at MR and histological examination. Irreversible focal necrosis was, however, observed in gray and white matter at weeks 3.

  • PDF

Data Sampling-based Angular Space Partitioning for Parallel Skyline Query Processing (데이터 샘플링을 통한 각 기반 공간 분할 병렬 스카이라인 질의처리 기법)

  • Chung, Jaehwa
    • The Journal of Korean Association of Computer Education
    • /
    • v.18 no.5
    • /
    • pp.63-70
    • /
    • 2015
  • In the environment that the complex conditions need to be satisfied, skyline query have been applied to various field. To processing a skyline query in centralized scheme, several techniques have been suggested and recently map/reduce platform based approaches has been proposed which divides data space into multiple partitions for the vast volume of multidimensional data. However, the performances of these approaches are fluctuated due to the uneven data loading between servers and redundant tasks. Motivated by these issues, this paper suggests a novel technique called MR-DEAP which solves the uneven data loading using the random sampling. The experimental result gains the proposed MR-DEAP outperforms MR-Angular and MR-BNL scheme.

Analysis of Material Removal Rate of Glass in MR Polishing Using Multiple Regression Design (다중회귀분석을 이용한 BK7 글래스 MR Polishing 공정의 재료 제거 조건 분석)

  • Kim, Dong-Woo;Lee, Jung-Won;Cho, Myeong-Woo;Shin, Young-Jae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.2
    • /
    • pp.184-190
    • /
    • 2010
  • Recently, the polishing process using magnetorheological fluids(MR fluids) has been focused as a new ultra-precision polishing technology for micro and optical parts such as aspheric lenses, etc. This method uses MR fluid as a polishing media which contains required micro abrasives. In the MR polishing process, the surface roughness and material removal rate of a workpiece are affected by the process parameters, such as the properties of used nonmagnetic abrasives(particle material, size, aspect ratio and density, etc.), rotating wheel speed, imposed magnetic flux density and feed rate, etc. The objective of this research is to predict MRR according to the polishing conditions based on the multiple regression analysis. Three polishing parameters such as wheel speed, feed rates and current value were optimized. For experimental works, an orthogonal array L27(313) was used based on DOE(Design of Experiments), and ANOVA(Analysis of Variance) was carried out. Finally, it was possible to recognize that the sequence of the factors affecting MRR correspond to feed rate, current and wheel speed, and to determine a combination of optimal polishing conditions.

Efficient Experimental Design for Measuring Magnetic Susceptibility of Arbitrarily Shaped Materials by MRI

  • Hwang, Seon-ha;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.3
    • /
    • pp.141-149
    • /
    • 2018
  • Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The $B_0$ maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled $B_0$ map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MR-visible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.

First Wall Design of ITER Test Blanket Module(TBM) based on RCC-MR Code (RCC-MR 코드에 기반한 ITER 시험증식블랑켓 일차벽 설계)

  • Shin, Kyu In;Lee, Dong Won
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.14-19
    • /
    • 2012
  • The Helium cooled ceramic reflector(HCCR) test blanket module(TBM) has been designed and developed to participate the ITER(International Thermonuclear Experimental Reactor) test blanket program in Korea. The TBM was one of the main objectives for developing ITER for proving the tritium self-sufficiency and the heat transfers to produce the electricity with the breeding blanket concept. Among the TBM components, the first wall(FW) was the most important component in safety since it was directly faced a high level of a heat and fast neutrons from the plasma side and could protect the others components inside TBM. In this paper, the FW has been designed through the thermo-mechanical analysis considering ITER operation conditions. With the developed simple models, the stress limit analysis based on RCC-MR code which is the nuclear power plant design codes in France was evaluated for the allowable design criteria. The results showed that the designed FW model satisfied $1.5S_m$ or $3S_m$ of the allowable stress($S_m$) in RCC-MR code at the maximum stress region in the FW.

Making Cache-Conscious CCMR-trees for Main Memory Indexing (주기억 데이타베이스 인덱싱을 위한 CCMR-트리)

  • 윤석우;김경창
    • Journal of KIISE:Databases
    • /
    • v.30 no.6
    • /
    • pp.651-665
    • /
    • 2003
  • To reduce cache misses emerges as the most important issue in today's situation of main memory databases, in which CPU speeds have been increasing at 60% per year, and memory speeds at 10% per year. Recent researches have demonstrated that cache-conscious index structure such as the CR-tree outperforms the R-tree variants. Its search performance can be poor than the original R-tree, however, since it uses a lossy compression scheme. In this paper, we propose alternatively a cache-conscious version of the R-tree, which we call MR-tree. The MR-tree propagates node splits upward only if one of the internal nodes on the insertion path has empty room. Thus, the internal nodes of the MR-tree are almost 100% full. In case there is no empty room on the insertion path, a newly-created leaf simply becomes a child of the split leaf. The height of the MR-tree increases according to the sequence of inserting objects. Thus, the HeightBalance algorithm is executed when unbalanced heights of child nodes are detected. Additionally, we also propose the CCMR-tree in order to build a more cache-conscious MR-tree. Our experimental and analytical study shows that the two-dimensional MR-tree performs search up to 2.4times faster than the ordinary R-tree while maintaining slightly better update performance and using similar memory space.

In-vivo $^1H$ MR Spectroscopy in Abscessess Induced in Rabbit Thighs: Evaluation of Treatment Effect (토끼 대퇴부에 유발한 농양의 생체내 수소 자기공명분광법: 치료효과 평가)

  • 구진모;장기현;이경호;한문희;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.31-38
    • /
    • 2003
  • Purpose : To analyze the serial changes of proton magnetic resonance (MR) spectra in the abscess and to determine the effect of the antibiotic treatment on the metabolite patterns. Materials and Methods : MR imaging and MR spectroscopy of an experimentally induced abscess were performed sequentially for four weeks at interval of one week in both the control group (n=5) and the antibiotic treatment group (n=5). On MR imaging, the shape and the size of the abscess were analyzed. On MR spectroscopy, the resonance peaks of metabolites were assigned on the basis of reported peaks in the literature. The metabolite ratios measured by using N-acetyl alanine as an external reference and by using lipid as an internal reference were compared in both the control and treatment g roups. Results : The abscesses were seen as cystic masses on MR imaging. On MR spectroscopy, the variable peaks of acetate, succinate and various amino acids, which are the metabolites of infection, were identified in the control and antibiotic treatment groups. The most frequent peak was that of acetate at 1.92ppm (70%). Both the peak ratios of acetate to lipid and acetate to external reference tended to decrease in the treatment group while the ratios did not change significantly in the control group. Conclusion : MR spectroscopy is useful not only for the diagnosis of abscess but also for monitoring the evolution of the abscess by using the acetate peak.

  • PDF

The Growth and EPA Synthesis of Shewanella oneidensis MR-1 and Expectation of EPA Biosynthetic Pathway

  • Jeong, Young-Su;Song, Sang-Kyu;Lee, Su-Jin;Hur, Byung-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.2
    • /
    • pp.127-133
    • /
    • 2006
  • Shewanella oneidensis MR-1 has the ability to inhale certain metals and chemical compounds and exhale these materials in an altered state; as a result, this microorganism has been widely applied in bioremediation protocols. However, the relevant characteristics of cell growth and biosynthesis of PuFAs have yet to be thoroughly investigated. Therefore, in this study, we have attempted to characterize the growth and fatty acid profiles of S. oneidensis MR-1 under a variety of temperature conditions. The fastest growth of S. oneidensis MR-1 was observed at $30^{\circ}C$, with a specific growth rate and doubling time of $0.6885h^{-1}\;and\;1.007 h$. The maximum cell mass of this microorganism was elicited at a temperature of $4^{\circ}C$. The eicosapentaenoic acid (EPA) synthesis of S. oneidensis MR-1 was evaluated under these different culture temperatures. S. oneidensis MR-1 was found not to synthesize EPA at temperatures in excess of $30^{\circ}C$, but was shown to synthesize EPA at temperatures below $30^{\circ}C$. The EPA content was found to increase with decreases in temperature. We then evaluated the EPA biosynthetic pathway, using a phylogenetic tree predicted on 16s rRNA sequences, and the homology of ORFs between S. oneidensis MR-1 and Shewanella putrefaciens SCRC-2738, which is known to harbor a polyketide synthase (PKS)-like module. The phylogenetic tree revealed that MR-1 was very closely related to both Moritella sp., which is known to synthesize DHA via a PKS-like pathway, and S. putrefaciens, which has been reported to synthesize EPA via an identical pathway. The homology between the PKS-like module of S. putrefaciens SCRC-2738 and the entire genome of S. oneidensis MR-1 was also analyzed, in order to mine the genes associated with the PKS-like pathway in S. oneidensis MR-1. A putative PKS-like module for EPA biosynthesis was verified by this analysis, and was also corroborated by the experimental finding that S. oneidensis MR-1 was able to synthesize EPA without the expression of $dihomo-{\gamma}-linoleic$ acid (DGLA) and arachidonic acid (AA) formed during EPA synthesis via the FAS pathway.