• Title/Summary/Keyword: MO image

Search Result 437, Processing Time 0.027 seconds

Luminescence characteristics of bismuth and europium co-doped yttrium oxide red phosphor for white light emitting diodes (Bi와 Eu이 도핑된 yttrium oxide의 white LED용 적색 형광체 발광 특성)

  • Park, W.J.;Jung, M.K.;Yoon, S.G.;Yoon, D.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.3
    • /
    • pp.112-115
    • /
    • 2006
  • The red emission properties of $Bi^{3+}$ co-doped $Y_2O_3:Eu^{3+}$ prepared by the solid-state reaction was investigated, in order to verify its potential to act as the red emitting phosphor of white LEDs. The emission spectrum consisted of a weak band at 581, 587, 5931 and 599 nm, with maximum sharp peaks occurring at about 611 nm due to the $^5D_0{\rightarrow}^7F_2$ transition of $Eu^{3+}$, while the excitation spectrum exhibited a broad band between 290 and 430 mm with peaks occurring in the range of $310{\sim}390nm$. Also, SEM image of the sample containing 0.43 mol% $H_3BO_3$ and 2.08 mol% $BaCl_2{\cdot}2H_2O$ phosphor particles grew to achieve diameters of $700{\sim}800nm$.

Three-Dimensional Conversion of Two-Dimensional Movie Using Optical Flow and Normalized Cut (Optical Flow와 Normalized Cut을 이용한 2차원 동영상의 3차원 동영상 변환)

  • Jung, Jae-Hyun;Park, Gil-Bae;Kim, Joo-Hwan;Kang, Jin-Mo;Lee, Byoung-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.16-22
    • /
    • 2009
  • We propose a method to convert a two-dimensional movie to a three-dimensional movie using normalized cut and optical flow. In this paper, we segment an image of a two-dimensional movie to objects first, and then estimate the depth of each object. Normalized cut is one of the image segmentation algorithms. For improving speed and accuracy of normalized cut, we used a watershed algorithm and a weight function using optical flow. We estimate the depth of objects which are segmented by improved normalized cut using optical flow. Ordinal depth is estimated by the change of the segmented object label in an occluded region which is the difference of absolute values of optical flow. For compensating ordinal depth, we generate the relational depth which is the absolute value of optical flow as motion parallax. A final depth map is determined by multiplying ordinal depth by relational depth, then dividing by average optical flow. In this research, we propose the two-dimensional/three-dimensional movie conversion method which is applicable to all three-dimensional display devices and all two-dimensional movie formats. We present experimental results using sample two-dimensional movies.

Template-Based Object-Order Volume Rendering with Perspective Projection (원형기반 객체순서의 원근 투영 볼륨 렌더링)

  • Koo, Yun-Mo;Lee, Cheol-Hi;Shin, Yeong-Gil
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.7
    • /
    • pp.619-628
    • /
    • 2000
  • Abstract Perspective views provide a powerful depth cue and thus aid the interpretation of complicated images. The main drawback of current perspective volume rendering is the long execution time. In this paper, we present an efficient perspective volume rendering algorithm based on coherency between rays. Two sets of templates are built for the rays cast from horizontal and vertical scanlines in the intermediate image which is parallel to one of volume faces. Each sample along a ray is calculated by interpolating neighboring voxels with the pre-computed weights in the templates. We also solve the problem of uneven sampling rate due to perspective ray divergence by building more templates for the regions far away from a viewpoint. Since our algorithm operates in object-order, it can avoid redundant access to each voxel and exploit spatial data coherency by using run-length encoded volume. Experimental results show that the use of templates and the object-order processing with run-length encoded volume provide speedups, compared to the other approaches. Additionally, the image quality of our algorithm improves by solving uneven sampling rate due to perspective ray di vergence.

  • PDF

An Analysis of Emotional and Cognitive Factors on Acupuncture (침에 대한 정서와 인지요소 분석)

  • Chae, Youn-Byoung;Park, Hi-Joon;Kang, O-Seok;Lee, Jeong-Chan;Park, Kyung-Mo;Lee, Hye-Jung
    • Journal of Acupuncture Research
    • /
    • v.24 no.3
    • /
    • pp.215-229
    • /
    • 2007
  • Objectives : Placebo phenomena have been considered as a confounding factor of clinical trial. Expectancy and belief of acupuncture have not been evaluated quantitatively. The present study was performed to analyze the emotional and cognitive factor .of acupuncture and investigate whether the expectancy of acupuncture treatment is associated with the cognition of acupuncture. Methods : The expectancy and the perception of bodily sensation (PBS) of 22 participants were assessed using self-reported questionnaire. The subjects used the self assessment manikin (SAM) to rate each of the standard affective image of the international affective picture system (lAPS) and other acupuncture-related image. Based on the degree of expectancy, the high expectant (HE) and the low expectant (LE) group were classified. The thermal and pressure pain threshold was objectively evaluated using radiant-heat device and algometer. The degree of expected pain of acupuncture and the actual pain of painful stimulation was subjectively evaluated using facial pain scales (FPS). Results : Using SAlVI analysis, we identified the negative correlation between hedonic valence and arousal dimension on acupuncture-related visual cue. The degree of the PBS and general pain threshold did not show any significant difference between the HE and the LE group. The HE group rated the acupuncture images as more pleasant, more arousing, than the LE group. In addition, we also found that the higher expectancy marked the lower FPS of the expected pain of acupuncture, but not of the actual pain of painful stimulation. Conclusions : Our preliminary study identified the psychological dimensions of acupuncture-related visual cue. These findings indicate that the expectancy of acupuncture could affect the cognition of acupuncture.

  • PDF

ALVEOLAR BONE CHANGES AROUND THE NATURAL TEETH OPPOSING THE POSTERIOR IMPLANTS IN MANDIBLE (임플랜트로 수복된 하악 구치부에 대합되는 자연치 주변의 골변화)

  • Jung, Won-Mo;Kim, Dae-Gon;Yi, Yang-Jin;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.263-273
    • /
    • 2007
  • Statement of problem: Alteration of tooth function is assumed to be changed by stress/strain on the adjacent alveolar bone, producing changes in morphology similar to those described for other load-bearing bones. When teeth are removed, opposing teeth will not be functioned. When edentulous area is restored by implant prostheses, opposing teeth will be received physiologic mechanical stimuli. Purpose: The aim of this study was to evaluate the bone changes around the teeth opposing implant restoration installed mandibular posterior area. Material and method: Eight patients who had mandibular posterior edentulous area were treated with implants. Radiographs of the opposing teeth were taken at implant prostheses delivery(baseline), 3 months, and 6 months later. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of opposing teeth. Direct digital image was obtained. Gray values of region of interest at each digital image were measured and compared according to time lapse. Repeated measured analysis of variance and post-hoc Scheffe's test were performed at the 95% significance level. Results: Alveolar bone changes around the natural teeth opposing the posterior implant in mandible showed statistically significant difference compared to control group(P<0.05). And gray values of alveolar bone around the teeth opposing implants were increased. There were no statistically significant differences of alveolar bone changes between crestal group and middle group and between mesial group and distal group according to time lapse(P>0.05). There were no statistically significant differences of alveolar bone changes among mesial-crestal group, mesial-middle group, distal-crestal group, distal-middle group, and control group(P>0.05). Conclusion: Alveolar bone around the natural teeth opposing the implant prosthesis showed gradual bony apposition.

Effect of frontal facial type and sex on preferred chin projection

  • Choi, Jin-Young;Kim, Taeyun;Kim, Hyung-Mo;Lee, Sang-Hoon;Cho, Il-sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-117
    • /
    • 2017
  • Objective: To investigate the effects of frontal facial type (FFT) and sex on preferred chin projection (CP) in three-dimensional (3D) facial images. Methods: Six 3D facial images were acquired using a 3D facial scanner (euryprosopic [Eury-FFT], mesoprosopic [Meso-FFT], and leptoprosopic [Lepto-FFT] for each sex). After normal CP in each 3D facial image was set to $10^{\circ}$ of the facial profile angle (glabella-subnasale-pogonion), CPs were morphed by gradations of $2^{\circ}$ from normal (moderately protrusive [$6^{\circ}$], slightly protrusive [$8^{\circ}$], slightly retrusive [$12^{\circ}$], and moderately retrusive [$14^{\circ}$]). Seventy-five dental students (48 men and 27 women) were asked to rate the CPs ($6^{\circ}$, $8^{\circ}$, $10^{\circ}$, $12^{\circ}$, and $14^{\circ}$) from the most to least preferred in each 3D image. Statistical analyses included the Kolmogorov-Smirnov test, Kruskal-Wallis test, and Bonferroni correction. Results: No significant difference was observed in the distribution of preferred CP in the same FFT between male and female evaluators. In Meso-FFT, the normal CP was the most preferred without any sex difference. However, in Eury-FFT, the slightly protrusive CP was favored in male 3D images, but the normal CP was preferred in female 3D images. In Lepto-FFT, the normal CP was favored in male 3D images, whereas the slightly retrusive CP was favored in female 3D images. The mean preferred CP angle differed significantly according to FFT (Eury-FFT: male, $8.7^{\circ}$, female, $9.9^{\circ}$; Meso-FFT: male, $9.8^{\circ}$, female, $10.7^{\circ}$; Lepto-FFT: male, $10.8^{\circ}$, female, $11.4^{\circ}$; p < 0.001). Conclusions: Our findings might serve as guidelines for setting the preferred CP according to FFT and sex.

FLEXURE STRENGTH OF CAST-JOINED CONNECTOR WITH Ni-Cr-Be ALLOY (주조연결된 니켈-크롬-베릴리움 주조체의 굽힘강도에 관한 비교연구)

  • Jeong, Chang-Mo;Jeon, Young-Chan;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.858-866
    • /
    • 1998
  • Soldering is the usual method used to correct an unstable fixed partial denture framework at patient's try-in; However, presoldering base metal alloys is technique-sensitve and results are unstable because it is difficult to maintain uniform heat distribution and to prevent oxidation of an alloy. A cast-joining technique has been developed by Weiss and Munyon for repair, correction and addition to base metal framework. This joining technique eliminates the problem with presoldering of non-precious frameworks. The object of this study was to 1) compare the relative flexure strength and the joining effectiveness of Ni-Cr-Be cast in two pieces and 'pre-soldered' versus in two pieces and 'cast-joined'. 2) determine the effect of increasing the number of retentive grooves on the face of the cast and 3) determine the effect of the relative matched position of groove patterns on flexure strength. The joining effectiveness can be expressed by the ratio of the mean flexure stress of soldered or cast-joined specimens to that of one-piece cast. Resin rods 3mm in diameter were used as pattern of specimens for one-piece casted, presoldered, and cast-joined groups. Cast-joined specimens had two different patterns of retentive grooves on the joined faces. Type A had cross-shaped grooves 1mm in depth. 0.6mm in width. Type B was the same except for the addition of one more retentive groove. In the experiment connecting cast-joined specimens, half of specimens with type A pattern had their patterns on the faces of paired casts matched with each other as mirror image. With the rest pairs, it was proceeded that one of paired casts turned 45 degrees so that the patterns crossed. Half of specimens with type B pattern also had the patterns matched as mirror image; However, here, one of paired casts turned 90 degrees with the other pairs. Retentive groove in this study lacked the intentional undercuts, in contrast with the suggestion of Weiss and Munyon. The specimens were subjected to four-point flexural loading in an Instron testing machine. The midspan flexural stress was calculated at the point of initial plastic strain as determined from a strip-chart recorder or at the point of failure if this occured at a lower stress level. Within the scope of this study, the following results were obtained. 1. The presoldered group showed flexural strength at least 2 times higher than the cast-joined groups. Its joining effectiveness was 82%. 2. In cast-joined groups, the flexural strength of joints with type B patterns exhibited 1.5 times that of joints with type A patterns. Joining effectivenesses were 38% for type B patterns, 25-26% for type A patterns. 3. The relative matched position of groove patterns did not have any significant effect on flexural strength of the cast-joined specimens with either type A patterns or type B patterns(p>.05).

  • PDF

Diagnosis of Ictal Hyperperfusion Using Subtraction Image of Ictal and Interictal Brain Perfusion SPECT (발작기와 발작간기 뇌 관류 SPECT 감산영상을 이용한 간질원인 병소 진단)

  • Lee, Dong Soo;Seo, Jong-Mo;Lee, Jae Sung;Lee, Sang-Kun;Kim, Hyun Jip;Chung, June-Key;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.20-31
    • /
    • 1998
  • A robust algorithm to disclose and display the difference of ictal and interictal perfusion may facilitate the detection of ictal hyperfusion foci. Diagnostic performance of localizing epileptogenic zones with subtracted SPECT images was compared with the visual diagnosis using ictal and interictal SPECT, MR, or PET. Ietal and interictal Tc-99m-HMPAO cerebral perfusion SPECT images of 48 patients(pts) were processed to get parametric subtracted images. Epileptogenic foci of all pts were diagnosed by seizure free state after resection of epileptogenic zones. In subtraction SPECT, we used normalized difference ratio of pixel counts(ictal-interictal)/interictal ${\times}100%$) after correcting coordinates of ictal and interictal SPECT in semi-automatized 3-dimensional fashion. We found epileptogenic zones in subtraction SPECT and compared the performance with visual diagnosis of ictal and interictal SPECT, MR and PET using post-surgical diagnosis as gold standard. The concordance of subtraction SPECT and ictal-interictal SPECT was moderately good(kappa=0.49). The sensitivity of ictal-interictal SPECT was 73% and that of subtraction SPECT 58%. Positive predictive value of ictal-interictal SPECT was 76% and that of subtraction SPECT was 64%. There was no statistical difference between sensitivity or positive predictive values of subtraction SPECT and ictal-interictal SPECT, MR or PET. Such was also the case when we divided patients into temporal lobe epilepsy and neocortical epilepsy. We conclude that subtraction SPECT we produced had equivalent diagnostic performance compared with ictal-interictal SPECT in localizing epileptogenic zones. Additional value of these subtraction SPECT in clinical interpretation of ictal and interictal SPECT should be further evaluated.

  • PDF

Multi-focal Microscopic System Using a Fiber Bundle (광섬유 다발을 이용한 다초점 현미경)

  • Gu, Young-Mo;Ham, Hyo-Shick;Choi, Sung-Eul
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.354-360
    • /
    • 2009
  • We have constructed and analyzed the performance of a simple fiber bundle multi-focal microscope. The microscope had a fiber bundle substituted for micro-lens array that is the core part of MMM(multi-focal multi-photon microscope). The MMM is a type of confocal microscope. To analyze the performance and characteristics of the fiber bundle multi-focal microscope, three types of samples were used: a standard grating, USAF 1951(7, 3), and 1951(7, 6). Using two polarizers and a polarizing beam splitter, we eliminated noise and got clear images. We obtained the FWHM of fiber spot images with the standard grating using two different magnifier lenses which were 63X and 20X, and found an image of the sample as a distribution of fiber spot images. For this case we used the low magnification lens, which gives denser distribution, so that we could get clearer images. In order to test the resolution of the fiber bundle multi-focal microscopic system, we used the USAF 1951 sample which has a smaller line interval than that of the standard grating. The FWHM of the line width of the image coincides well with the real line width of the USAF 1951 sample. We confirmed the performance of a fiber bundle multi-focal microscopic system which is relatively simple but has submicron resolution and is able to get 1600 images at the same time.

Analysis on the utilization Pattern of a General Hospital - With Cases of General Hospital Inpatients in the Provincial Area - (종합병원 이용형태에 관한 분석 - 지방소재 종합병원 입원환자 중심 -)

  • Jung, Yong-Mo;Jun, Sun-Kyong;Lee, Yong-Chul
    • The Korean Journal of Health Service Management
    • /
    • v.3 no.1
    • /
    • pp.14-24
    • /
    • 2009
  • This study aims at deriving any useful information necessary to strengthen the competitiveness for growth through empirical analyses on general hospital located in a province in order to countermeasure the opening and competition of medical markets. The characteristics of user were identified on the basis of disease groups under KCD in the research method. In addition, the analysis on the expenses of diagnosis and treatment was divided into the treatment progress and degree of hospital resource utilization And the regression was carried out to identify the impacts of characteristics of inpatient users on the degree of hospital resource utilization. As a result of major research, the inpatient users of the general hospital located in the provincial area in consideration of inpatient users were formed around the inpatient disease groups representative for Korea(diseases of the respiratory system, injury and poisoning & certain other consequences of external causes). And it was understood that most of residents within a distance of 40 minute by the public transportation were using. And mostly were under the age of 9 or over 60, and the provision of medical features such as the degree of consultation and operational functions were inadequate. When we classify inpatient treatment cost for each resource application as the medical cost being the center of patient care function, the equipment and human resource application sector are constituted over half. Accordingly, the following suggestions are made as plans to strengthen the competitiveness for the growth of general hospitals located in the provincial areas on the basis of analytical results. First, it is necessary to have the characterization matching to the age and disease groups with a high frequency. Second, it is necessary to increase the degree of hospital resource utilization according to the characterization. Third, it is necessary to concentrate on public relations. The above suggestion, as a method for securing image improvement and competitive power as a general hospital, and through expansion of social function that a regional general hospital needs to secure not only as an individual institution but also as a general hospital, it can be seen that a general improvement of image as a regional general hospital is possible.

  • PDF