• 제목/요약/키워드: MM-estimates

검색결과 114건 처리시간 0.027초

Predicting the stiffness of shear diaphragm panels composed of bridge metal deck forms

  • Egilmez, Oguz O.
    • Steel and Composite Structures
    • /
    • 제24권2호
    • /
    • pp.213-226
    • /
    • 2017
  • The behavior of building industry metal sheeting under shear forces has been extensively studied and equations have been developed to predict its shear stiffness. Building design engineers can make use of these equations to design a metal deck form bracing system. Bridge metal deck forms differ from building industry forms by both shape and connection detail. These two factors have implications for using these equations to predict the shear stiffness of deck form systems used in the bridge industry. The conventional eccentric connection of bridge metal deck forms reduces their shear stiffness dramatically. However, recent studies have shown that a simple modification to the connection detail can significantly increase the shear stiffness of bridge metal deck form panels. To the best of the author's knowledge currently there is not a design aid that can be used by bridge engineers to estimate the stiffness of bridge metal deck forms. Therefore, bridge engineers rely on previous test results to predict the stiffness of bridge metal deck forms in bracing applications. In an effort to provide a design aid for bridge design engineers to rely on bridge metal deck forms as a bracing source during construction, cantilever shear frame test results of bridge metal deck forms with and without edge stiffened panels have been compared with the SDI Diaphragm Design Manual and ECCS Diaphragm Stressed Skin Design Manual stiffness expressions used for building industry deck forms. The bridge metal deck form systems utilized in the tests consisted of sheets with thicknesses of 0.75 mm to 1.90 mm, heights of 50 mm to 75 mm and lengths of up to 2.7 m; which are representative of bridge metal deck forms frequently employed in steel bridge constructions. The results indicate that expressions provided in these manuals to predict the shear stiffness of building metal deck form panels can be used to estimate the shear stiffness of bridge metal deck form bracing systems with certain limitations. The SDI Diaphragm Design Manual expressions result in reasonable estimates for sheet thicknesses of 0.75 mm, 0.91 mm, and 1.21 mm and underestimate the shear stiffness of 1.52 and 1.90 mm thick bridge metal deck forms. Whereas, the ECCS Diaphragm Stressed Skin Design Manual expressions significantly underestimate the shear stiffness of bridge metal deck form systems for above mentioned deck thicknesses.

Distribution of the intraosseous branch of the posterior superior alveolar artery relative to the posterior maxillary teeth

  • Carsen R. McDaniel;Thomas M. Johnson;Brian W. Stancoven;Adam R. Lincicum
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.121-127
    • /
    • 2024
  • Purpose: Preoperative identification of the intraosseous posterior superior alveolar artery (PSAA) is critical when planning sinus surgery. This study was conducted to determine the distance between the cementoenamel junction and the PSAA, as well as to identify factors influencing the detection of the PSAA on cone-beam computed tomography (CBCT). Materials and Methods: In total, 254 CBCT scans of maxillary sinuses, acquired with 2 different scanners, were examined to identify the PSAA. The distance from the cementoenamel junction (CEJ) to the PSAA was recorded at each maxillary posterior tooth position. Binomial logistic regression and multiple linear regression were employed to evaluate the effects of scanner type, CBCT parameters, sex, and age on PSAA detection and CEJ-PSAA distance, respectively. P-values less than 0.05 were considered to indicate statistical significance. Results: The mean CEJ-PSAA distances at the second molar, first molar, second premolar, and first premolar positions were 17.0±4.0 mm, 21.8±4.1 mm, 19.5±4.7 mm, and 19.9±4.9 mm for scanner 1, respectively, and 17.3±3.5 mm, 16.9±4.3 mm, 18.5±4.1 mm, and 18.4±4.3 mm for scanner 2. No independent variable significantly influenced PSAA detection. However, tooth position (b=-0.67, P<0.05) and scanner type (b=-1.3, P<0.05) were significant predictors of CEJ-PSAA distance. Conclusion: CBCT-based estimates of CEJ-PSAA distance were comparable to those obtained in previous studies involving cadavers, CT, and CBCT. The type of CBCT scanner may slightly influence this measurement. No independent variable significantly impacted PSAA detection.

시뮬레이션을 통한 다양한 로버스트 회귀추정량의 비교 연구 (A comparison study of various robust regression estimators using simulation)

  • 장수희;윤정연;전희주
    • 응용통계연구
    • /
    • 제29권3호
    • /
    • pp.471-485
    • /
    • 2016
  • 회귀모형의 대표적인 추정법인 최소제곱법은 오차항의 분포가 정규분포를 따르고 이상치가 없는 상황에서는 최적이지만, 자료가 회귀모형의 가정을 만족하지 않을 경우 또는 이상치를 포함하는 경우와 같이 자료가 오염된 상황에서는 왜곡된 추정 결과를 준다. 따라서 이상치에 민감한 최소제곱법의 단점을 보완하기 위해 다양한 로버스트 추정방법이 제안되었다. 본 논문에서는 MLE를 기반으로 제안된 M 추정량, 순서형 통계량을 기반으로 제안된 L 추정량, 잔차의 순위를 기반으로 제안된 R 추정량 계열에서 높은 붕괴점 또는 높은 효율을 갖는 대표적인 추정량들을 다양한 모의실험을 통해 비교 연구하였다. 추정량의 성능을 비교하는데 효율성 뿐만 아니라 편의, 분산을 포함한 분포를 살펴보았다. 그 결과 실제 데이터 적용에는 MM 추정량과 GR 추정량이 좋은 성능을 가진 것으로 보였다.

166Ho-chitosan 복합체의 복강 내 투여를 위한 베타선 흡수선량 평가 (Beta Dosimetry in Intraperitoneal Administration of 166Ho-chitosan Complex)

  • 김은희;임상무;박경배
    • 대한핵의학회지
    • /
    • 제32권1호
    • /
    • pp.99-108
    • /
    • 1998
  • Intraperitoneal administration of radioisotopes is suggested to treat the metastatic ovarian cancer in the peritoneal cavity. Administering beta-emitting radioisotopes into the peritoneal cavity allows the maximum energy delivery to the cancerous cells of the peritoneal wall surface while sparing the normal cells located in deep site of the peritoneal wall. In this study, dose estimates of the peritoneal wall are provided to be used for prescribing the amount of $^{166}Ho$-chitosan complex administered. The $^{166}Ho$-chitosan complex diffused in the peritoneal fluid may attach to the peritoneal wall surface. The attachment fraction of $^{166}Ho$-chitosan complex to the peritoneal wall surface is obtained by simulating the ascites with Fischer rats. Both volume source in the peritoneal fluid and the surface source over the peritoneal wall surface are counted for the contribution to the peritoneal wall dose. The Monte Carlo code EGS4 is used to simulate the energy transfer of the beta particles emitted from $^{166}Ho$. A plane geometrical model of semi-infinite volume describes the peritoneal cavity and the peritoneal wall. A semi-infinite plane of $10{\mu}m$ in thickness at every 1 mm of depth in the peritoneal wall is taken as the target in dose estimation. Greater than 98 percents of attachment fraction has been observed from the experiments with Fischer rats. Given $1.3{\mu}Ci/cm^2$ and $2.4{\mu}Ci/ml$ of uniform activity density, absorbed dose is 123 Gy, 8.59 Gy, 3.00 Gy, 1.03 Gy, and .327 Gy at 0 mm, 1 mm, 2 mm, 3 mm, and 4 mm in depth to the peritoneal wall, respectively.

  • PDF

심폐소생술에서 두 개의 가속도 센서를 활용한 흉부 압박 깊이 추정 (Estimation of Chest Compression Depth using two Accelerometers during CPR)

  • 송영탁;오재훈;서영수;지영준
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.407-411
    • /
    • 2010
  • During the cardiopulmonary resuscitation (CPR), the correct chest compression depth and period are very important to increase the resuscitation possibility. For the feedback of chest compression depth, the depth monitoring device based on the accelerometer is developed and widely used. But this method tends to overestimate the compression depth on the bed. To overcome this limitation, the chest compression depth estimation method using two accelerometers is suggested With the additional accelerometer between the patient and mattress on the bed, the compression of the mattress is also measured and it is used to compensate the overestimation error. The experimental results show that the single accelerometer estimates as 61.4mm for the actual compression depth of 43.6mm on the mattress. The depth estimation with the dual accelerometer was 44.6mm which is close to the actual depth. With the automatic zeroing in every single compression, the integration error for the depth can be reduced. The dual accelerometer method is effective to increase the accuracy of the chest compression depth estimation.

SLA를 이용한 쾌속조형시 성형오차와 보정 (Forming Error and Compensation in RP Using SLA)

  • 박상량;박동삼
    • 한국정밀공학회지
    • /
    • 제19권3호
    • /
    • pp.152-159
    • /
    • 2002
  • SLA (Stereolithography Apparatus) it a process used to rapidly produce polymer components directly from a computer representation of the part. Though SLA is being recognized as an innovative technology, it still cannot be used to fully practical application since it lacks of dimensional accuracy compared to conventional process. If the shrinkage were perfectly uniform and no distortion took place, excellent part accuracy could still be achieved through and appropriate scaling factor when generating the build file. However, in certain geometries involving intersecting thick and thin sections, nonuniform retrain shrinkage becomes the engine of part distortion. In order to improve the part accuracy of SLA, this paper evaluates how largely each parameter of SLA contributes to the part accuracy and estimates the optimal set of parameter which minimizes the dimension error of the test part, "Slab (100mm$\times$100mm$\times$2mm)"and "scale bar"part. Three control parameters such as critical exposure, generation depth and fill cure depth are used.

동화지구 절계 수문량 재추정 (Reestimation of Hydrologic Design Data in Donghwa Area)

  • 권순국;이재형;정재성;전일권;김민환;이경도
    • 한국농공학회논문집
    • /
    • 제46권6호
    • /
    • pp.3-10
    • /
    • 2004
  • The fundamental study of hydrologic redesign of Donghwa area located in a sccond tributary of Seomjin river was performed. The amounts of hydrologic design were estimated using the available cumulated hydrology data provided by Korea Agricultural and Rural Infrastructure Corporation (KARICO). The management status of The water resources in Donghwa area was also widely surveyed. The probability rainfalls, probable maximum precipitation (PMP) and probability floods were estimated and subsequently their changes analyzed. The amount of 200 year frequency rainfall with l day duration was 351.1 mm, 2.5 % increased from the original design value, and The PMP was 780.2 mm. The concentration time was reestimated as 2.5 hours from existing 2.4 hours. Soil Conservation Service(SCS) method was used to estimate effective rainfall- The runoff curve number was changed from 90 to 78, therefore the maximum potential retention was 71.6 mm, 154 % increased from the original value. The Hood estimates using SCS unit hydrograph showed 8 % increase from original value 623 $m^3$/s to 674 $m^3$/s and The probable maximum Hood was 1,637 $m^3$/s. Although the Row rate at the dam site was increased, the Hood risk at the downstream river was decreased by the Hood control of the Donghwa dam.

증발량 산정을 위한 증발접시계수 산정모형 개발: 서울지점을 중심으로 (Development of pan coefficient model for estimating evaporation: focused on Seoul station)

  • 임창수
    • 한국수자원학회논문집
    • /
    • 제53권7호
    • /
    • pp.557-567
    • /
    • 2020
  • 서울지역에 대해서 6개의 증발접시계수 산정모형들로부터 산정된 증발접시계수를 측정된 증발접시 증발량과 FAO Penman-Monteith 기준증발산량으로부터 산정된 증발접시계수와 비교함으로서 증발접시계수 산정모형들의 활용 적합성을 평가하였다. 적용된 6개의 모형은 Cuenca 모형, Snyder 모형, Pereira 등의 모형, Allen 등의 모형, Orang 모형, 그리고 Raghuwanshi와 Wallender 모형이다. 또한 산정된 증발접시계수를 이용하여 산정된 증발량을 관측된 증발량과 비교분석하였으며, 비교결과를 바탕으로 서울지역에 대해서 증발접시계수 산정모형을 개발하였다. 연구결과에 의하면 기존에 연구자들에 의해서 제안된 6개 증발접시계수 산정모형을 10 m, 15 m 그리고 20 m의 풍역대 거리로 설정하여 적용하는 경우 모든 풍역대 거리에서 Snyder에 의해서 제안된 증발접시계수가 가장 양호한 증발접시계수 산정값을 보였다. 반면에 Pereira 등의 모형으로부터 산정된 증발접시계수 값이 관측값과 가장 큰 차이를 보였다. 따라서 서울지역을 대상으로 Snyder모형을 수정한 증발접시계수 산정모형을 유도하였다. 본 연구에서 제시한 모형을 적용하는 경우 모든 풍역대 거리(10 m, 15 m, 20 m) 조건에서 산정된 월평균 증발량은 동일하게 92.1 mm이고 관측된 월평균 증발량은 91.9 mm로서 다른 모형들과 비교하여 가장 근사한 결과를 보였다.

전기로 산화 슬래그 골재를 사용한 콘크리트의 횡 구속 거동에 관한 실험적 연구 (Experimental Study on Behavior of Confined Concrete with Electric Arc Furnace Oxidizing Slag Aggregates)

  • 김상우;이정미;이용준;정유진;김길희
    • 콘크리트학회논문집
    • /
    • 제23권2호
    • /
    • pp.195-201
    • /
    • 2011
  • 이 연구에서는 나선 철근으로 횡 구속된 전기로 산화 슬래그 골재를 사용한 콘크리트의 구조적 성능을 평가한다. 전기로 산화 슬래그는 철강 산업의 부산물로서, 그동안 유리석회와 유리마그네슘의 팽창성질 때문에 저부가가치적인 용도로만 이용되어 왔지만 최근 제강 기술의 발달에 힘입어 안정화된 전기로 산화 슬래그 골재의 생산이 가능하여 졌다. 구조용 콘크리트에 대한 전기로 산화 슬래그 골재의 적용성을 검증하기 위하여, 직경이 150 mm이고 높이가 300 mm인 실린더형 실험체를 총 27개 제작하고 횡 구속 실험을 수행하였다. 실험 변수는 골재의 종류와 나선 철근의 항복 강도로 하였다. 실험 결과, 전기로 산화 슬래그 골재를 사용한 실험체의 구조적 성능이 천연골재를 사용한 횡 구속된 콘크리트와 비교하여 동등 이상인 것을 확인할 수 있었다.

Thermal and uplift histories of Mesozoic granites in Southeast Korea: new fission track evidences

  • Shin, Seong-Cheon;Susumu Nishimura
    • 암석학회지
    • /
    • 제2권2호
    • /
    • pp.104-121
    • /
    • 1993
  • Fission track (FT) thermochronological analyses on Mesozoic granites provide new information about cooling and uplift histories in Southeast Korea. Twenty-nine new FT sphene, zircon and apatite ages and seven track length measurements are presented for eleven granite samples. Measured mineral ages against assumed closure temperatures yield cooling rates for each sample. Relatively rapid (7-$15^{\circ}C$/Ma) and simple cooling patterns from the middle Cretaceouss (ca. 90-100 Ma) granites are caused mainly by a high thermal contrast between the intruding magma and country rocks at shallow crustal levels (ca. 1-2.5 km-depths). On the contrary, a slow overall cooling (1-$4^{\circ}C$/Ma) of the Triassic to Jurassic granites (ca. 250-200 Ma), emplaced at deep depths (>>9 km), may mainly depend upon very slow denudation of the overlying crust. The uplift history of the Triassic Yeongdeog Pluton in the Yeongyang Subbasin, west of the Yangsan Fault, is characterized by a relatively rapid uplift (~0.4 mm/a) before the total unroofing of the pluton in the earliest Cretaceous (~140 Ma) followed by a subsidence (~0.2mm/a) during the Hayang Group sedimentation. Stability of original FT zircon ages (156 Ma) and complete erasure of apatite ages suggest a range of 3 to 5.5 km for the basin subsidence. Since 120 Ma up to present, the Yeongyang Subbasin has been slowly uplifted (~0.04 mm/a). The FT age patterns of Jurassic granites both from the northeastern wing of the Ryeongnam Massif and from the northern edge of the Pohang-Kampo Block indicate that the two geologic units have been slowly uplifted with a same mean rate (~0.04 mm/a) since early Cretaceous. Estimates of Cenozoic total uplifts since 100 Ma are different: Ryeongnam Massif (~6 km)=Pohang-Kampo Block (~6 km)>Yeongyang Subbasin(~4 km).

  • PDF