• Title/Summary/Keyword: MM

Search Result 35,933, Processing Time 0.071 seconds

Electrochemical Characteristic on Hydrogen Intercalation into the Interface between Electrolyte of the 0.1N H2SO4and Amorphous Tungsten Oxides Thin Film Fabricated by Sol-Gel Method (졸-겔법으로 제조된 비정질의 텅스텐 산화물 박막과 황산 전해질 계면에서 일어나는 수소의 층간 반응에 대한 전기화학적 특성)

  • Kang, Tae-Hyuk;Min, Byoung-Chul;Ju, Jeh-Beck;Sohn, Tae-Won;Cho, Won-Il
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1078-1086
    • /
    • 1996
  • The peroxo-polytungstic acid was formed by the direct reaction of tungsten powder with the hydrogen peroxide solution. Peroxo-polytungstic powder were prepared by rotary evaporator using the fabricated on to ITO coated glass as substrate by dip-coating method using $2g/10mL(W-IPA/H_2O)$ sol solution. A substrate was dipped into the sol solution and after a meniscus had settled, the substrate was withdrawn at a constant rate of the 3mm/sec. Thicker layer could be built up by repeated dipping/post-treatment 15 times cycles. The layers dried at the temperature of $65{\sim}70^{\circ}C$ during the withdrawn process, and then tungsten oxides thin film was formed by final heating treatment at the temperature of $230{\sim}240^{\circ}C$ for 30min. A linear rotation between the thickness of thin film and the number of dipping/post-treatment cycles for tungsten oxides thin films made by dip-coating was found. The thickness of thin film had $60{\AA}$ after one dipping. From the patterns of XRD, the structure of tungsten oxides thin film identified as amorphous one and from the photographs of SEM, the defects and the moderate cracks were observed on the tungsten oxides thin film, but the homogeneous surface of thin films were mostly appeared. The electrochemical characteristic of the $ITO/WO_3$ thin film electrode were confirmed by the cyclic voltammetry and the cathodic Tafel polaization method. The coloring bleaching processes were clearly repeated up to several hundreds cycles by multiple cyclic voltammetry, but the dissolved phenomenon of thin film revealed in $H_2SO_4$ solution was observed due to the decrease of the current densities. The diffusion coefficient was calculated from irreversible Randles-Sevick equation from the data obtained by the cyclic voltammetry with various scan rates.

  • PDF

Antimicrobial Effect of Red Ginseng Against Major Food Poisoning Microorganisms Including Staphylococcus aureus (황색포도상구균을 포함한 식중독 미생물들에 대한 홍삼의 항균효과)

  • Kwak, Yi-Seong;Jung, Myung-Gyun;Jang, Kyoung-Hwa;Han, Min-Woo;Yu, Byeung-Il
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.382-390
    • /
    • 2020
  • This study was carried out to evaluate the antimicrobial effect of red ginseng (Panax ginseng C.A. Meyer) against several foodborne pathogens including Staphylococcus aureus, Escherichia coli, Candida albicans and Aspergillus niger. The antimicrobial effect was determined by agar diffusion method using red ginseng extract, crude saponin and non-water-soluble fractions. Red ginseng extract showed antimicrobial effect against S. aureus, but not C. albicans or A. niger. The extract showed anti-bacterial activity at concentration above 30% against S. aureus, which cause both food poisoning and atophic dermatitis. Crude saponin showed antibacterial activity above 7.5% against the bacterium. However, the ginsenosides purified from crude saponin showed no antimicrobial activities at 100-200 ㎍/mL. To investigate the mode of growth inhibition, red ginseng extract and crude saponin were added to 0.85% NaCl solution containing S. aureus and then incubated at 35℃ for 12 h. The results showed that viable cells were rapidly reduced in above 10% concentration of red ginseng extract and above 2% of crude saponin, respectively. However, the crude saponin and red ginseng extract did not inhibit the bacterial cells completely at those same concentrations. On the other hand, whereas all non-water-soluble fractions showed inhibition zones above 10 mm against S. aureus, they showed no inhibition effects against E. coli, C. albicans or A. niger. The methanol fraction-1 (MF-1) showed the highest antibacterial activity against S. aureus, and the MIC (minimal inhibitory concentration) was 0.625 mg/mL. These results suggest that red ginseng extract, crude saponin and non-water-soluble fractions show selective antibacterial activity against S. aureus, and non-water-soluble fractions might be used as natural antibacterial agents.

Effect of Root Zone Warming by Hot Water on Fruit Characteristics and Yield of Greenhouse- Grown Oriental Melon (Cucumis melo L.) (온수 지중가온이 참외의 과실특성 및 수량에 미치는 영향)

  • 신용습;이우승;연일권;최성국;최부술
    • Journal of Bio-Environment Control
    • /
    • v.6 no.2
    • /
    • pp.110-116
    • /
    • 1997
  • This experiment was conducted to investigate the effects of root zone warming on fruit yield of oriental melon (Cucumis melo L. var. Makuwa) in winter season. Root zone was warmed by hot water flowing through pipe set at 35cm depth from the ridge. Treatments of minimum soil temperature at 20cm depth were 17, 21, $25^{\circ}C$ and non-warming from Jan. 18 to Apr. 18. The results are summarized as follows. 1. The blooming of female flower was faster 1 days in 17$^{\circ}C$ plot, 6 days in 21$^{\circ}C$ plot, and 7 days in $25^{\circ}C$ plot than in control plot and the days from blooming to harvesting were shorter 5 days in 17$^{\circ}C$ plot, 11 days in 21$^{\circ}C$ plot, and 12 days in $25^{\circ}C$ plot than in control plot. 2. Mean fruit weight was the highest in 21$^{\circ}C$ plot, followed $25^{\circ}C$, 17$^{\circ}C$ and control plots, respectively, and flesh thickness was the highest in $25^{\circ}C$ plot, followed by 21, 17$^{\circ}C$ and control plots, respectively. 3. Early and middle-phase yield was the highest in $25^{\circ}C$ plot, followed by 21$^{\circ}C$, 17$^{\circ}C$ and control plots but late yield was the highest in 17$^{\circ}C$ plot, followed by control, 21, and $25^{\circ}C$ plots. Total yield per 10a was higher 33% in 17$^{\circ}C$ plot, 49% in 21$^{\circ}C$ plot, and 37a in $25^{\circ}C$ plots than in control plot, harvested 1, 490kg per 10a. 4. Total yield was highest in 21$^{\circ}C$ plot, followed by $25^{\circ}C$, 17$^{\circ}C$, and control plots. Malformed and fermented fruit rates were the highest in control, followed by 17, 25, and 21$^{\circ}C$ plots and marketable fruit rate was 21, 25, 17$^{\circ}C$, and control plot in order.

  • PDF

Evaluation of shear-bond strength between different self-adhesive resin cements with phosphate monomer and zirconia ceramic before and after thermocycling (인산염계 기능성 단량체가 첨가된 수종의 자가 접착 레진시멘트와 지르코니아 세라믹 사이 열순환 전후 전단결합강도 비교)

  • Lee, Ji-Hun;Kim, Min-Kyung;Lee, Jung-Jin;Ahn, Seung-Geun;Park, Ju-Mi;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.318-324
    • /
    • 2015
  • Purpose: This study compared shear bond strengths of five self-adhesive cements with phosphate monomer to zirconium oxide ceramic with and without airborn particle abrasion. Materials and methods: One hundred zirconia samples were air-abraded ($50{\mu}mAl_2O_3$). One hundred composite resin cylinders were fabricated. Composite cylinders were bonded to the zirconia samples with either Permacem 2.0 (P), $Clearfil^{TM}$ SA Luting (C), $Multilink^{(R)}$ Speed (M), $RelyX^{TM}$ U200 Automix (R), G-Cem $LinkAce^{TM}$ (G). All bonded specimens were stored in distilled water ($37^{\circ}C$) for 24 h and half of them were additionally aged by thermocycling ($5^{\circ}C$, $55^{\circ}C$, 5,000 times). The bonded specimens were loaded in shear force until fracture (1 mm/min) by using Universal Testing Machine (Model 4201, Instron Co, Canton, MA, USA). The failure sites were inspected under field-emission scanning electron microscopy. The data was analyzed with ANOVA, Tukey HSD post-hoc test and paired samples t-test ($\alpha$=.05). Results: Before and after thermocycling, $Multilink^{(R)}$ Speed (M) revealed higher shear-bond strength than the other cements. G-Cem $LinkAce^{TM}$ (G) showed significantly lower bond strengths after thermocycling than before treatment (P<.05), but the other groups were not significantly different (P>.05). Conclusion: Most self-adhesive cements with phosphate monomer showed high shear bond strength with zirconia ceramic and weren't influenced by thermocycling, so they seem to valuable to zirconia ceramic bonding.

EFFECT OF SOFT-START LIGHT CURING ON THE POLYMERIZATION AND THE CONTRACTION STRESS OF COMPOSITE RESIN (완속기시(Soft-start) 광조사 방식이 복합레진의 중합 및 수축응력에 미치는 효과)

  • Wee, You-Min;Oh, You-Hyang;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.332-343
    • /
    • 2005
  • The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at $400\;mw/cm^2$, plasma arc light curing for 6 seconds at $1300\;mW/cm^2$ and LED light curing for 10 seconds at $7The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at . For the soft-start curing method ; 2 seconds light exposure at $650\;mW/cm^2$ followed by 3 seconds at $1300\;mW/cm^2$ and exponential increase with 5 seconds followed by 10 seconds at $700\;mW/cm^2$ were used. Contraction stress was measured using strain gauge method and Vickers hardness was measured 24 hours after polymerization at the top and bottom of specimens. Resin-acrylic interfaces were observed using a scanning electron microscope(SEM). The results of present study can be summarized as follows: 1. Contraction stresses at 10 min after polymerization were significantly reduced with the soft-start curing both in plasma and LED light sources(P<0.05). 2. Plasma light curing with soft-start resulted in not only the lowest contraction stress, but also the lowest hardness(P<0.05) 3. LED light curing with soft-start showed lower contraction stress than the one-step continuous halogen and LED light curing(P<0.05). 4. Microhardness of specimens cured by LED light with soft-start was equivalent to that of cured by the one-step continuous halogen and LED light(P>0.05). 5. Curing by LED light with soft-start and conventional halogen light resulted in better marginal sealing than plasma light and one-step LED light curing.

  • PDF

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

The Effect of Surface Treatment on the Shear Bond Strength of Resin Cement to Zirconia Ceramics (표면처리가 지르코니아와 레진 시멘트의 전단결합강도에 미치는 효과)

  • Jung, Seung-Hyun;Kim, Kye-Soon;Lee, Jae-In;Lee, Jin-Han;Kim, Yu-Lee;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.83-94
    • /
    • 2009
  • The aim of this study was to investigate the shear bond strength between zirconia ceramic and resin cement according to various surface treatments. The surface of each zirconia ceramic was subjected to one of the following treatments and then bonded Rely X Unicem or Rely X ARC resin cement; (1) Rocatec system and $50{\mu}m$ surface polishing, (2) No treatment and $50{\mu}m$ surface polishing, (3) Rocatec system and $1{\mu}m$ surface polishing, (4) No treatment and $1{\mu}m$ surface polishing. Each of eight bonding group was tested in shear bond strengths by universal testing machine(Z020, Zwick, Ulm, Germany) with crosshead speed of 1mm/min. The results were as follows; 1. Rocatec treatment groups showed greater bonding strengths than No Rocatec groups. There was significant difference of among groups(P<0.001) 2. For Rocatec groups, $50{\mu}m$ surface roughness groups showed greater bonding strengths than $1{\mu}m$ surface roughness groups.(P<0.001) But for No Rocatec groups, There was no significant difference of among groups(P>0.05) 3. Rely X Unicem groups showed greater bonding strengths than Rely X ARC groups. There was significant difference of among groups(P<0.01) Within the conditions of this study, Rocatec treatment was an effective way of increasing zirconia bonds to a resin cement, even in the case of self-adhesive resin cement.

COPD Patients with Hypercapnic Respiratory Failure : Response to Therapy and Determinant of Intubation (만성폐쇄성폐질환 환자의 고탄산혈증성 호흡부전 : 치료 반응 및 기도삽관의 결정인자)

  • Song, So-Hyang;Kim, Chi-Hong;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.462-472
    • /
    • 2001
  • Background : The determinants of intubation and the response to therapy in COPD patients with hypercapnic respiratory failure were retrospectively reviewed. Methods : This study involved a review of 132 episodes of hypercapnic respiratory failure($PaCO_2\;{\geq}\;50\;mmHg$ and $pH\;{\leq}\;7.35$). The time frame for resolution or the time to intubation of patients who were admitted between 1996 and 1999 was analyzed. Results : Out of 132 hypercapnic episodes, 49(37%) required intubation. A comparison was made with the 83 cases that responded to treatment. Patients requiring intubation had a greater severity of illness, which included a higher APACHE II (Acute Physiology and Chronic Health Evaluation II) score ($20{\pm}5$ vs $14{\pm}4$ ; p<0.01), a higher WBC, a higher serum BUN, and greater acidosis (pH, $7.23{\pm}0.11$ vs $7.32{\pm}0.04$ ; p<0.01). Those with the most severe acidosis(pH<7.20) had the highest intubation rate(87%) and shortest time to intubation($2{\pm}3\;h$). Conversely, those with an initial pH 7.31 to 7.35 were less likely to be intubated(20%), and had a longer time to intubation($97{\pm}121\;h$). The patients with a pH 7.21 to 7.25($4.1{\pm}2.9$ day) required longer period of time to respond to medical treatment than patients with a pH of 7.31 to 7.35($2.2{\pm}3.1$ day). Of those patients requiring intubation, half(55%) were intubated within 8 h of admission, and most (75%) within 24 h. Of those patients responding to treatment medical therapy, half(52%) recovered within 24 h and most (78%) recovered within 48 h. Conclusion: Respiratory acidosis at the initial presentation is associated with an increased likelihood of intubation. This should assist in deciding help with the decision whether to treat patients medically, institute noninvasive ventilation, or proceed to intubation.

  • PDF

Clinical and Radiographic Characteristics of 12 Patients with Mycobacterium abscessus Pulmonary Disease (Mycobacterium abscessus 폐질환 환자 12명의 임상적, 방사선학적 특징)

  • Koh, Won-Jung;Kwon, O Jung;Kang, Eun Hae;Jeon, Ik Soo;Pyun, Yu Jang;Ham, Hyoung Suk;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Han, Daehee;Kim, Tae Sung;Lee, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.1
    • /
    • pp.45-56
    • /
    • 2003
  • Background : Mycobacterium abscessus is the most common respiratory pathogen in rapidly growing mycobacteria and is resistant to all of the first-line antituberculosis drugs. This report describes the clinical and radiographic characteristics in patients with pulmonary disease caused by M. abscessus. Materials and Methods : Twelve patients with pulmonary disease caused by M. abscessus who fulfilled the 1997 American Thoracic Society diagnostic criteria for a nontuberculous mycobacterial pulmonary infection were observed over a five-and-a-half year period. The clinical characteristics and chest radiographic findings were analyzed, retrospectively. Results : The patients were predominantly female(11/12, 92%) and nonsmokers(12/12, 100%). Coughing (10/12, 83%), sputum(10/12, 83%) and hemoptysis(10/12, 83%) were the common symptoms and they had prolonged periods from the onset of symptoms to the diagnosis of their disease(median 6.5 years). Eleven (92%) patients had a previous history of being treated for pulmonary tuberculosis. The sputum specimens were acid-fast bacilli smear-positive in all patients. All patients were administered antituberculosis drugs. Six (50%) patients were treated with second-line antituberculosis drugs on account of persistent smear-positive sputum specimens. The chest radiographs showed that reticulonodular opacities(11/12, 92%) were the most common pattern of abnormality, followed by cavitary lesions(5/12, 42%). The computed tomography findings suggested bronchiolitis from the centrilobular nodules with a tree-in-bud appearances(9/10, 90%) and bronchiectasis (9/10, 90%) were the most common, followed by well-defined nodules smaller than 10-mm in diameter(7/10, 70%). Conclusions : M. abscessus pulmonary disease should be recognized as a cause of chronic mycobacterial lung disease, and respiratory isolates should be assessed carefully.