• Title/Summary/Keyword: MM

Search Result 35,933, Processing Time 0.049 seconds

Optical Design of an Integrated Two-Channel Optical Transmitter for an HDMI interface (광 HDMI 인터페이스용 2채널 광송신기 광학 설계)

  • Yoon, Hyun-Jae;Kang, Hyun-Seo
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.5
    • /
    • pp.269-274
    • /
    • 2015
  • In this paper we design the optical system for an integrated two-channel TO-type optical transmitter to apply the HDMI interface using the code V simulator. The proposed integrated two-channel optical transmitter has two VCSELs attached in parallel on an 8-pin TO-CAN package, on top of which is a lens filter block ($1mm{\times}2mm{\times}4mm$) composed of hemispherical lenses and WDM filters. Considering two-channel transmitters manufactured with wavelength combinations of 1060nm/1270nm and 1330nm/1550nm, we obtain the optimum value of the diameter of the hemispherical lens as 0.6 mm for both combinations, and the distances L between the lens filter block and ball lens as 1.7 mm and 2.0 mm for the 1060nm/1270nm and 1330nm/1550nm wavelength combinations, respectively. At this time, the focal length f0 of the lens filter blocks for wavelengths of 1060, 1270, 1330, and 1550 nm are 0.351, 0.354, 0.355, and 0.359 mm, respectively, and the focal lengths F of light passing through the lens filter block and ball lens are 0.62 mm for 1060nm/1270nm and 0.60-0.66 mm for 1330nm/1550nm wavelength combinations.

Consideration of Standardized Uptake Value (SUV) According to the Change of Volume Size through the Application of Astonish TF Reconstruction Method (Astonish TF 재구성 기법의 적용을 통한 체적 크기의 변화에 따른 표준섭취계수(SUV)에 관한 고찰)

  • Lee, Juyoung;Nam-Kung, Sik;Kim, Ji-Hyeon;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2014
  • Purpose: In addition to improving the quality of the PET image, through much research, the development of various programs are performed. Astonish TF reconstruction techniques by Philips can confirm the improved contrast of the lesion. Also, It's image reconstruction of 2 mm is possible with rapid reconstruction rate than conventional. In this study, we compared and evaluated Standardized Uptake Value (SUV) in accordance with the 2 mm reconstruction techniques and traditional 4 mm from the $^{18}F-FDG$ PET whole body image. Materials and Methods: In the phantom experiment, NEMA IEC body phantom (sphere: 10, 13, 17, 22, 28, 37 mm) was used to obtain images by using GEMINI TF 64 PET/CT (Philips, Cleveland, USA). Also, In the clinical images, we performed $^{18}F-FDG$ PET/CT examination to 30 women (age: $55.1{\pm}11.3$, BMI: $24.1{\pm}2.9$) with a diagnosis of breast cancer. After that, we reconstructed images in 2 mm and 4 mm respectively. The region of interest was drawn to acquired images. Since then, we measured SUV and statistically analyzed with SPSS ver.18 by using EBW (Extended Brilliance Workstation) NM ver.1.0. Results: After analyzing the result of the phantom study, there was a tendency that the bigger hot sphere size, the higher SUV. If you compared the 2 mm reconstruction techniques to 4 mm, it increased 95.78% in 10 mm, 50.60% in 13 mm, 25.00% in 17 mm, 30.04% in 22 mm, 31.81% in 28 mm, and 27.84% in 37 mm. Through the result of the analysis of the 2 mm reconstruction techniques and 4 mm in clinical images, it appeared that SUV of 2 mm was higher than that of 4 mm. Also the smaller the volume was, the more the change rate increased. Conclusion: After analyzing the result of the clinical picture and phantom experiments applied by Astonish TF reconstruction techniques, as the size of the volume was small, the change rate of the SUV increased. Therefore, it was necessary to further research about the SUV correction for accurate and active utilization of 2 mm reconstruction techniques which had excellent lesion discrimination ability and contrast in clinic.

  • PDF

Direct Carrier System Based 300mm FAB Line Simulation (Direct 반송방식에 기반을 둔 300mm FAB Line 시뮬레이션)

  • Lee, Hong-Soon;Han, Young-Shin;Lee, Chil-Gee
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.2
    • /
    • pp.51-57
    • /
    • 2006
  • Production environment of semiconductor industry is shifting from 200mm wafer process to 300mm wafer process. In the new era of semiconductor industry, FAB (fabrication) Line Automation is a key issue that semiconductor industry is facing in shifting from 200mm wafer fabrication to 300mm wafer fabrication. In addition, since the semiconductor manufacturing technologies are being widely spread and market competitions are being stiffened, cost-down techniques became basis of growth. Most companies are trying to reduce average cycle time to increase productivity and delivery time. In this paper, we simulated 300mm wafer fabrication semiconductor manufacturing process by laying great emphasis on reduce average cycle time.

  • PDF

Evaluation of Detector Dependency on Collimator in SRS: Compared Detectors; CC01, CC13, SFD (뇌정위적 방사선수술 시 콜리메이터 크기 변화에 따른 검출기 의존성 평가)

  • Bae, Yong-Ki;Bang, Dong-Wan;Park, Byung-Moon;Kang, Min-Yeong;Kim, Yeon-Rye
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.109-113
    • /
    • 2008
  • Purpose: To evaluate the detector dependency in the various collimator size for Stereotactic Radiosugery (SRS). Materials and Methods: This study was performed with 6 MV photon beam (Varian 21EX, Varian, US) and the measurement detectors are used by ion chamber CC01, CC13 (Wellhofer, Germany) and stereotactic diode detector (SFD, Wellhofer, Germany). SRS collimator size was used by ${\varphi}$5, 10, 20, 30 mm (Brain Lab, Germany). Percentage depth dose (PDD) was measured at SSD 100 cm and field size 10×10 cm from individual detectors. Ouput factor was measured by using same setup of PDD and with maximum dose depth. Data was normalized at field size $10{\times}10\;cm$. Beam profile was measured at SSD 100 cm in SRS collimator ${\varphi}$10, 30 mm and field $10{\times}10\;cm$ and a comparison of FWHM (full width half maximum), penumbra width (20~80%). Results: The CC13 detector was overestimated 16% than other detectors from the PDD in the 5 mm collimator. Output factors were underestimated CC01 28%, CC13 72% in the 5 mm collimator and CC01 9.6%, CC13 25% in the 10 mm collimator than the SFD. Maximum difference was 3% at the FWHM of the dose profile in the 10 mm collimator and difference of the 30 mm collimator was 0% at the FWHM. Penumbra width was increased CC01 122%, CC13 194% in the 10 mm collimator and CC01 68%, CC13 185% in the 30 mm collimator than the SFD. Conclusion: It is very important for accurate dosimetry to select a detector in small field. The SFD was considered with the most accurate dosimeter for small collimator dosimetry in this study.

  • PDF

Intermediate Culture of the Spat of Arkshell, Scapharca broughtonii in Summer (피조개, Scapharca broughtonii 부착치패의 하계 중간양성)

  • Min, Kwang-Sik;Kim, Byoung-Hak;Lee, Seung-Ju;Park, Ki-Yeol;Kim, Byung-Goun
    • The Korean Journal of Malacology
    • /
    • v.20 no.2
    • /
    • pp.125-130
    • /
    • 2004
  • Arkshell, Scapharca broughtonii spats were placed in natural environmental condition for 30 days from July 28 to August 27, 2004, in order to estabilish intermediate culture technique. Growth and survival of the spats in different intermediate culture areas with various culture methods were measured. Water temperature of studied area ranged from 24.1 to 28.5$^{\circ}C$, salinity was 15.4 to 33.3 psu, dissolved oxygen was 3.92 to 12.6 mg/l. Scapharca broughtonii spats cultured in Yeosu developed the best, 10.15 ${\pm}$ 1.12 mm in average shell length, and the highest survival was recorded as 77% in Namhae. Shell lengths of the Scapharca broughtonii spats cultured in the water depths of 2, 5, and 10 m were 7.14 ${\pm}$ 1.14 mm, 6.98 ${\pm}$ 1.74 mm and 6.27 ${\pm}$ 1.33 mm, and the survivals showed 75.5%, 77.0% and 76.5%, respectively. When 1 mm, 2 mm, and 3 mm-sized spats were cultured for 30 days in water depth of 5 m, the shell length increased to 6.73 ${\pm}$ 1.46 mm, 6.98 ${\pm}$ 1.74 mm and 7.04 ${\pm}$ 1.19 mm, and survivals were 67.0%, 77.0% and 58.5%, respectively. The shell lengths of spat cultured for 30 days in mesh sizes of 1 ${\times}$ 1 mm, 2 ${\times}$ 2 mm and 3 ${\times}$ 3 mm, 5 m below the surface were 8.14 ${\pm}$1.23 mm, 8.26 ${\pm}$ 1.19 mm and 8.78 ${\pm}$ 1.16 mm, and survivals were 41.5%, 43.0% and 44.5%, respectively.

  • PDF

Changes in frictional resistance between stainless steel bracket and various orthodontic wires according to a change in moment (모멘트 변화에 따른 브라켓과 교정용 선재 사이의 마찰력 변화)

  • Jeong, Hye-Jin;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.137-149
    • /
    • 2007
  • Objective: The purpose of this study was to compare changes in frictional resistance between the bracket and wire under dry and wet conditions according to a change in moment. Methods: A stainless steel bracket of $0.022"{\times}0.028"$ slot, and $0.019"{\times}0.025"$ stainless steel, beta-titanium, and nickel-titanium wires were used. A 10 mm length lever was attached to the test (sliding) brackets to generate a moment. The experimental model was designed to allow tipping until contacts were established between the wire and the mesiodistal edges of the bracket slot. The moment was generated by suspending a 100 g or 200 g weight on the end of the lever. The moments applied were $1000g{\cdot}mm\;(100g{\times}10mm)\;and\;2000g{\cdot}mm\;(200g{\times}10mm)$. The test brackets were ligated with elastomeric ligature for a constant ligation force and the fixed brackets were ligated with stainless steel ligature. Brackets were moved along the wire by means of an universal testing machine, and maximum frictional resistances were recorded. Results: Stainless steel wire showed least frictional resistance and there was no significant difference between beta-titanium and nickel-titanium except at $2000g{\cdot}mm$ moment in wet conditions. Frictional resistance of all wires increased as the moment increased from $1000g{\cdot}mm\;to\;2000g{\cdot}mm$. Under wet conditions, the frictional resistance of stainless steel wires increased in both $1000g{\cdot}mm\;and\;2000g{\cdot}mm$ moment conditions, but frictional resistance of nickel-titanium and beta-titanium increased only in $2000g{\cdot}mm$ conditions. Conclusion: These results indicated that various conditions influence on frictional resistance. Therefore, laboratory studies of frictional resistance should simulate clinical situation.

Antimicrobial Activity of Extracts from Some Traditional Oriental Medicinal Plants against Dental Caries Bacteria (치아우식 원인균에 대한 한약재 추출물의 항균효과)

  • Lee, Hee-Woen;Lee, Pureunhaneul;Kwon, Hyun-Jung;Han, Kook-Il;Han, Man-Deuk
    • Journal of dental hygiene science
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2013
  • Antimicrobial activity of extract from some traditional oriental medicinal plants were evaluated for their antimicrobial activity against six oral pathogens, Streptococcus salivarius, Streptococcus oralis, Streptococcus mutans, Streptococcus sanguinis, Lactobacillus acidophilus and Lactobacillus casei, which are associated with caries disease. The antimicrobial activity was examined by determining the inhibition zone using the disc diffusion assay. In antibacterial activity test, extracts of Scutellaria baicalensis, Chrysanthemum indicum, Kochia scoparia, Hydnocarpus anthelmintica and Caesalpinia sappan showed inhibitory effects (40 mg/ml) against tested caries bacteria. Especially, the C. sappan extract showed the strongest activity on S. oralis (40 mm), L. casei (35 mm) and S. mutans (28 mm). Thus, this result suggests that C. sappan may be applicable to preventing dental caries.

ON THE MORPHOLOGY OF LARVAL STAGES OF LOPHIUS LITULON (JORDAN) (황아귀, Lophius litulon (Jordan)의 자어기의 형태)

  • KIM Yong Uk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.4
    • /
    • pp.273-280
    • /
    • 1976
  • Morphological changes of early larval stages of Lophius litulon (Jordan) are described based on 861 individuals collected at the intertidal zone at Haeundae, Busan, on the 20th of June, 1976. Particular emphasis is paid on the development of dorsal spinous rays, ventral fin rays, chromatophore patterns, alimentary canal, gills, branchiostegal rays and teeth. The premordial spinous fin ray of the first dorsal fin appears at the newly hatched larva of around 2.70mm in total length, the second spinous ray at around 5.82mm, and the third spinous ray at around 6.45 nm. Premordial fin rays which develope as a semicircle to cudgel form of the ventral fin appear posterior to the pectoral fin at the larva of around 2.70mm in total length. When the larvae grow up to 6.35mm in total length, the length of the ventral fin is more or less half of the total length of the body. In the early stages$(2.70\~3.75mm)$ melanophores are scattered irregularly on the tail . In the later stages(4.25mm) melanophores are aggregated to form three black spots on medio-lateral part of the tail. The newly hatched larvae have the premordial alimentary canal with mouth and intestine. With decreasing yolk mass the intestine appears more distinctly with curvature, and mouth seems to open. Gills appear at the larvae of 6.35mm in total length; branchiostegal rays appear at the larvae of 6.45mm. Teeth appear at the larvae of 6.25mm.

  • PDF

Characteristic of Coils According to Volume in Case of Embolization of Cerebral Aneurysm (뇌동맥류에 대한 색전술 시 체적에 따른 코일 특성)

  • Chae, Soo-In;Baek, Chang-Moo;Kim, Jeong-Koo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.247-254
    • /
    • 2012
  • This study presents the assessment results of coil length characteristics according to the volume of cerebral artery among the inpatients that received angiography and coil embolization following intracranial aneurysm from March, 2010 to September 2011. The volume rendering method was applied to the patients that received embolization to their cerebral arteries to obtain volume measurements. After coil embolization, the volume ratios were calculated with the volumes and lengths of coils. The embolic volume ratios were $43.11{\pm}3.11%$, $36.07{\pm}2.03%$, 40.91%, and 38.25% when the aneurysm sizes were 6mm or less, 6~10mm, 10~15mm and 20mm or more, respectively, being similar to the recommended volume ratios. Regardless of the types of aneurysm, the coil length according to volume was 0.65cm per $1mm^3$ of 20~$100mm^3$ when one type of 0.25mm diameter coil was used. They were 0.62cm per $1mm^3$ of 20~$150mm^3$ when one type of coil was used in the aneurysm volume of the saccular type and 0.60cm per $1mm^3$ of 20~$90mm^3$ when one type of coil was used in the aneurysm volume of the multi-lobulated type.

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF