Methyl ethyl ketone (MEK) and methyl isobutyl ketone (MIBK) have been widely used as solvents in various industries. Biodegradation of MEK and MIBK by Pseudomonas putida KT-3, which could utilize MEK or MIBK as a sole carbon source, was characterized, and the cosubstrate interaction in MEK/MIBK mixture was also studied. Within the range of initial MEK concentration (from 0.5 to 5.5 mM), an increased substrate concentration increased the specific degradation rate of MEK by P putida KT-3 (from 3.15 to 10.58 mmol/g DCW$\cdot$h), but the rate sightly increased at 11.0 mM of initial MEK concentation (11.28 mmol/g DCW$\cdot$h). The similar degradation rates of MIBK (4.69-4.92 mmol/g DCW$\cdot$h) were obtained at more than 3.0 mM of initial MIBK concentation. Kinetic analysis on the degradation of MEK/MIBK mixture by P. putida KT-3 showed that MEK or MIBK acted as a competitive inhibitor. Maximum degradation rate ($V_{max}$), saturation constant ($K_{m}$) and inhibition constant ($K_{1}$) were as follows: $V_{max,MEK}$=12.94 mmol/g DCW$\cdot$h; $K_{m,MEK}$=1.72 mmol/L; $K_{l,MEK}$=1.30 mmol/L; $V_{max,MIBK}$=5.00 mmol/g-DCW$\cdot$h; $K_{m,MIBK}$=0.42 mmol/L; $K_{l,MEK}$=0.77 mmol/L.
A method was presented for the analysis of trace metals in iron oxide ore. The method utilized ammonium pyrrolidinedithiocarbamate (APDC)-methyl isobutyl ketone (MIBK) extraction procedure and analysis by atomic absorption spectroscopy (AA). Citrate at pH $8{\sim}10$ for the determination of Co, Ni and Cu or tiron at pH $6{\sim}7$for the determination of Mn and Cu was added as a masking agent to prevent extraction of Fe(III) into the organic phase. Reduction of solubility of MIBK in water was achieved by addition of NaCl as a salting-out agent. Back extraction of the MIBK extracts with aqueous $HNO_3$ was also studied to increase the stability of metal extracts.
Kim, Ji-Hyeon;Yang, Tae-Yeong;Lee, Yun-Bok;Yun, Seok-Yeong;Park, Heung-Chae
Korean Journal of Materials Research
/
v.11
no.6
/
pp.519-526
/
2001
The effects of methyl isobutyl ketone(MIBK)/ethanol(EtOH) solvent mixtures on the dispension, particle size distribution and rheology of $Al_2$O$_3$/ZrO$_2$ nonaqueous suspensions were investigated by measuring sedimentation density and viscosity. The sedimentation density of $Al_2$O$_3$ and ZrO$_2$ particles increased in MIBK-rich($\geq$60 vol%) solvents with 'Hypermer' KD-1 as a dispersant. The ball-milled suspensions in 80MIBK/20EtOH(vol%) solvent exhibited the narrow and unimodal particle size distribution. Although all Suspensions exhibited the Pseduo-Plastic flow(Shear thinning) the shear thinning behavior was somewhat different depending on the mixture ratio of $Al_2$O$_3$/ZrO$_2$ and MIBK/EtOH. Under a given shear rate( <300 s$^{-1}$ for $Al_2$O$_3$; <3000 s$^{-1}$ for ZrO$_2$) the strongest shear thinning appeared in the $Al_2$O$_3$ and ZrO$_2$ suspensions with pure MIBK solvent. The shear thinning was nearly independable on the mixture ratio of $Al_2$O$_3$/ZrO$_2$ in case of using the identical solvent(80MIBK/20EtOH, vol%).
The optimum conditions for measuring cadmium content of less than 0.2ppm by flame atomic absorption spectrophotometry were investigated. The cadmium in urine was extracted by APDC-MIBK for the analysis by atomic absorption spectrophotometry after ashing them by a wet method. 1. Optimum conditions by APDC-MIBK and DDTC-MIBK extractions. The acidic aqueous solution was prepared with appropriate amount of 0.IN nitric acid, 5ml of 25% (W/V) sodium potasstum tartarate, 10ml of saturated ammonium sulfate, and 2ml of 2% APDC(or 1 ml of 5% DDTC) chelating agent. The total volume of solution was adjusted to 55 ml and pH to $2{\sim}10$ (or$7{\sim}10$). The aqueous solution was extracted with 10ml MIBK. Concentration of Triton X-100 did not effect the absorbance for APDC-MIBK extraction of cadmium, but absorbance decreased as the concentration increased for DDTC-MIBK extraction. The sensitivity and detection limits for the cadmium determination from APDC-MIBK extraction were 0.0038ppm and 0.0102, 0.0022ppm and 0.0116 for DDTC-MIBK, and 0.0132ppm and 0.0034 for 0.1N nitric acid. APDC-MIBK and DDTC-MIBK extractions were 3 times higher than 0.1N nitric acid for the sensitivity. 2. Excretion of cadmium in 24-hour urine by APDC-MIBK extraction. Determination of cadmium in urine by atomic absorption spectrophotometry of A.A. (Cd=2 mA) mode and B.C. (Cd=4 mA) mode and B.C. (Cd=4mA, $D_2=20mA$) mode showed some difference (p<0.05). The difference of cadmium determination and recovery according to method of standard additions and standard calibration curve method in urine was not significant (p>0.05, $93.48{\pm}11.78%,\;94.83{\pm}22.00%$). Excretion of cadmium in 24-hour urine collection from normal person and variance analysis within measurement variation was not significant (p>0.05), but between interindividual was significant (0.05). Determination of cadmium content by two different methods of flame atomic absorption spectrophotometry and dithizone colorimetry showed that the results from the two methods can be described by a regression line with a good correlation (y=1.0153x-0.2927, x=Cd by D.C., y=Cd by A.A.S., $r=0.8651^*$, p<0.01).
The 242.795 nm on ICP-AES for the gold analysis was the most sensitive wavelength which was also interfered severely by the spectra of other metal ions such as manganese, chromium, cobalt, and iron. In order to analyze the gold in ore, the gold must be separated from the interfering ions. The best solvent for separation of gold in ore solution was 10 % n-hexane contained MIBK mixed solvent. The gold recovery was 97.5 % from mixed metal solution contained about 2 M $HNO_3$ and 0.5 M HCl.
Solvent extraction of Li(I) from weak HCl solution was investigated by the mixture of TBP/MIBK with other neutral extractants such as Cyanex 923, TOPO and TOP. The TBP/MIBK organic phase was loaded with 0.1 M $FeCl_3$ at different HCl concentrations (1-9 M). Extraction of Li(I) from weak HCl solution is related to the stability of $FeCl_3$ in the organic mixture. As HCl concentration increased in preparing the loaded TBP phase, the stripping percentage of Fe(III) during the extraction of Li(I) became reduced and thus Li(I) could be extracted by ion exchange reaction with hydrogen ion in the organic. The concentration of TBP in the extractant mixture affected the stability of $FeCl_3$. Compared to TBP, Fe(III) was easily stripped from the loaded MIBK and thus no Li(I) was extracted by the mixture with MIBK. The nature of neutral extractant with TBP/MIBK showed little difference in the extraction of Li(I) and stripping of Fe(III).
In physical and reactive extraction of acrylic acid using various solvents the equilibrium characteristics of extraction were investigated. The degree of extraction in reactive extraction with Tri-n-octylamine(TOA) was 1.5~3 times than that in physical extraction. Distribution ratio was constant in methyl isobutyl ketone(MIBK) and n-butylacetate(n-BAc) but was increased with increasing the concentration of acrylic acid in benzene and chloroform. It can be explained by formation of dimers. Maximum extraction leadings of acrylic acid were three in benzene and were two in MIBK, chloroform and n-BAc, and it was found that acrylic acid was extracted as the form of $A_3$R In benzene and $A_2R$ in MIBK, chloroform and n-BAc. In effect of solvent, the degree of extraction was increased as he difference of solubility parameter of solvent and solute was decreased, and as dielectric constant of solvent was increased.
Journal of the Korea Academia-Industrial cooperation Society
/
v.5
no.2
/
pp.174-185
/
2004
Organic pollutants (Phenol, 2-Chlorophenol, Nitrobenzene) were separated from wastewater by nondispersive membrane solvent extraction, using a microporous hydrophobic hollow fiber module. The system was operated countercurrently and cocurrently with the aqueous phase flowing through the fiber lumens and the solvent flowing through the shell side. The distribution coefficients of several solvents (MIBK, IPAc, Hexane) were examined and MIBK was selected as an extracting solvent. Separation efficiency of countercurrent flow method was better than that of cocurrent flow method. Also, the overall mass transfer coefficients were determined.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.5
no.2
/
pp.200-211
/
1995
This study was designed to evaluate the effects of temperature and humidity on the sampling efficiency of mixed organic vapors of l,2-DCE, benzene, and MIBK by 3 different types of diffusion monitors. Independent variables used for the study were temperatures ($25^{\circ}C$, $35^{\circ}C$), humidities (30%, 80%), and vapor concentrations (low, medium, and high). In addition, vapor concentrations measured by the traditional charcoal tube method were used as reference values and were compared with those of by diffusion monitors. The results were as follows: 1. The desorption efficiencies(DE) of 1,2-DCE and benzene from charcoal tubes and from diffusion monitors ranged from 98% to 105%. In contrast, the DEs of MIBK from charcoal tubes and diffusion monitors except DM1 ranged from 71% to 85%. The DE of MIBK from DM1 was 98%. 2. No statistically significant differences of 1,2-DCE concentrations and the sampling efficiencies regardless of temperatures and humidities studied between charcoal tube and 3 diffusion monitors were found. 3. At 80% humidity, increasing frequencies of 1,2-DCE breakthrough at higher temperature and higher vapor concentration measured by charcoal tubes were observed. 4. No statistically significant difference of benzene concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly lower at all experimental conditions except the $35^{\circ}C$ and 30% humidity condition. 5. No statistically significant difference of MIBK concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly higher at higher humidity conditions regardless of temperature. Although statistically not significant, sampling efficiency of MIBK showed positive correlation with humidity while negative correlation with concentration was observed. 6. For sampling 1,2-DCE and benzene, no significant variations of concentrations among three diffusion monitors regardless of temperature and humidity conditions were found. For MIBK sampling, however, wide variations with increasing humidity among diffusion monitors were obtained. In conclusion, this study suggests that diffusion monitors will be a reasonables substitute for the traditional charcoal tubes for sampling non-polar organic vapors at temperature and humidity conditions studied. For polar organic vapors, use of an alternative desorption solution other than CS2 is recommended because of its low desorption efficiency. In addition, since variable among diffusion monitors for polar organic vapors particularly at higher humidity conditions were observed, further study is recommended of the effects of humidity on the performance of diffusion monitors.
Journal of Korean Society of Environmental Engineers
/
v.32
no.8
/
pp.747-753
/
2010
This study was performed to investigate the removal characteristics of volatile organic compounds (VOCs) in the gasphase biofilters, and to propose a stoichiometric analysis approach to characterize biological reaction through carbon mass balance. The VOCs studied were toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) as a single substrate for each biofilter. The critical loading rate was determined to be $46.9\;g/m^3{\cdot}hr$, $25.8\;g/m^3{\cdot}hr$, $96.3\;g/m^3{\cdot}hr$, and $66.5\;g/m^3{\cdot}hr$ for toluene, styrene, MEK, and MIBK, respectively. The obtained results indicated that the critical loading rate was well correlated the octanol-water partition coefficient. In the analysis of carbon mass balance, carbon recovery to $CO_2$ became relatively lower as substrate loadings increased, but higher for carbon recovery to biomass. Stoichiometric analysis revealed that biomass yield increased as substrate loadings increased, and its coefficient (g biomass/g substrate) varied from 0.31 to 0.57 for toluene, 0.29 to 0.57 for styrene, 0.08 to 0.56 for MEK, and 0.14 to 0.53 for MIBK.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.