• 제목/요약/키워드: MH Lamp

검색결과 32건 처리시간 0.021초

오징어 채낚기어선용 LED 집어등의 어획성능 (Fishing efficiency of LED fishing lamp for squid jigging vessels)

  • 안영일
    • 수산해양기술연구
    • /
    • 제49권4호
    • /
    • pp.385-394
    • /
    • 2013
  • This study has conducted a comparative analysis on the fishing efficiency of LED fishing lamps by squid jigging vessels, the Yeongrak-ho (16 tons) and Somang-ho (9.77 tons), which operated during September and October 2010 and during October 2011, comparing with MH (Metal Halide) fishing lamp-equipped fishing vessels. This study has also examined vessel's fuel consumption level. The light powers of LED fishing lamps of the Yeongrak-ho and Somang-ho were 25.8kW and 32kW, respectively. Those of the MH fishing vessels, that is, the MH fishing lamp-equipped fishing vessels, were 105kW and 81kW, respectively. The average squid catch in number of an LED vessel, Yeongrak-ho, was 39.2% of the MH fishing lamp-equipped fishing vessels; however, that of the Somang-ho improved to 78.7% of the MH fishing lamp-equipped vessels. Average catch in number by Yeongrak-ho crew was 2.6 times more than catch in number by automatic jigging machines. Average catch in number by MH fishing vessel crew was 1.8 times more than that by automatic jigging machines. An LED vessel, Yeongrak-ho's fishing rate was 17.5%~152.2% of the MH fishing vessels, that is, 61.1% on average, in comparison of combined catch in number per automatic jigging machine and per crewmember. Somang-ho's fishing rate was 6.7%~127.6% of the MH fishing vessels, that is, 73.1% on average. The average fuel consumption level of the Somang-ho, throughout its departure from to arrival at the port, was 475.7l, and that during fishing hours was 109.6l, or 23.0% of the total fuel consumption level. Somang-ho's fuel consumption level per fishing hour was 9.7l on average.

방전램프의 광질에 따른 상추의 생장 및 파이토케미컬 분석 (Growth and Phytochemicals of Lettuce as Affected by Light Quality of Discharge Lamps)

  • 이재수;남상운;김용현
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.400-407
    • /
    • 2013
  • 본 연구는 식물공장용으로 방전램프로서 메탈할라이드램프(MH), 고압나트륨램프(HPS), 제논램프(XE)를 사용하고, 냉백색형광등(FL)을 대조구로 사용한 가운데 상추(Lactuca sativa L. cv. Jeokchima)의 생육 및 파이토케미컬의 특성을 분석하고자 수행되었다. 식물공장 내부의 환경조건은 광주기 16/8h, 광합성유효광양자속(photosynthetic photon flux, PPF) $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 기온 $22/18^{\circ}C$, 습도 70%, $CO_2$ 농도 $400{\mu}mol{\cdot}mol^{-1}$로 조절하였다. 각 램프의 분광 특성을 이용하여 PPF에 대한 청색광 영역(400~500nm), 녹색광 영역(500~600nm), 적색광 영역(600~700nm)의 비율을 계산하였다. MH램프의 청색광 영역은 23.0%로서 다른 처리구에 비해서 가장 높게 나타났다. 한편 HPS램프의 청색광 영역은 4.7%로서 가장 낮게 나타났으나, 적색광 영역은 38.0%로서 다른 처리구에 비해서 높게 나타났다. 정식 후 11일째와 21일째에 측정된 상추의 엽장, 엽폭, 엽면적, 지상부 생체중 및 건물중은 방전램프의 광질에 따른 유의차가 나타날 정도로 다르게 나타났다. HPS 처리구의 엽면적은 $143,486mm^2$로서 대조구의 $98,474mm^2$에 비해서 45.7% 크게 나타났으며, MH와 XE 처리구는 대조구에 비해서 각각 16.3%, 9.5%로 크게 나타났다. 이러한 결과는 지상부 생체중에서도 유사하게 나타났다. 적색광 영역의 비율이 높은 HPS 처리구에서는 상추의 잎 관련 생장 특성에서 최대치가 나타났으나, 청색광 영역의 비율이 높은 MH와 XE 처리구에서는 낮게 나타났다. 방전등 처리구에 따라 상추 잎에 축적된 아스코르빈산 함량은 대조구에 비해서 작게 나타났으며, 처리구 사이에 유의차가 인정되지 않았다. 상추 잎의 안토시아닌 함량은 MH 처리구에서 0.70mg/100g으로 최대치가 나타났으며, XE와 HPS 처리구는 대조구의 0.58mg/100g에 비해서 각각 79.3%, 8.6%수준이었다. 결과적으로 방전램프의 종류에 따라 상추의 생장 특성, 아스코르빈산 및 안토시아닌 함량이 다르게 나타났다. 따라서 식물공장용 인공광원으로서 방전램프를 효율적으로 활용하면서, 상추의 생장 및 파이토케미컬 함량을 증진시키기 위해서는 분광 특성이 상이한 방전램프의 병용 또는 단색광 LED의 추가 설치 등과 같은 방전램프의 광질 개선이 요구된다.

대용량 (360W급) LED 집어등의 오징어 어획성능 (Fishing efficiency of high capacity (360W) LED fishing lamp for squid Todarodes pacificus)

  • 안영일
    • 수산해양기술연구
    • /
    • 제50권3호
    • /
    • pp.326-333
    • /
    • 2014
  • This study was conducted to investigate the fishing efficiency of an improved LED fishing lamp for squids. A total of 31 fishing operations were carried out with six-crew commercial fishing vessel Haengbok-Ho (24 tons) on which 43.2kW LED was installed, along with 14 automatic jigging machines, from October 6 to November 16, 2012. The 19 fishing vessels with Haengbok-Ho were compared with a control subject was 24 tons or 29 tons. A total illuminating power of metal halide (MH) fishing lamps in the control fishing vessel was either 84kW or 120kW. The number of automatic jigging machines in the control vessels was 8-18 and the number of crews engaged for fishing operation was 3-13. Average fuel consumption of LED fishing vessels during fishing operation was 505.1l which led to an average fuel consumption of 42.7l per hour. LED fishing vessel and MH fishing vessel caught on an average 1,946 squids and 2,439 squids, respectively, during the study period. Crews (hand line and hand reel) caught about 2.2 times the automatic jigging machines for LED fishing vessel and about 2.1 times for MH fishing vessel. Meanwhile, catches by the fishing vessels with LED in the combined total number per one line of automatic jigging machine and per crew were 86.6% of that of the control fishing vessel with MH. Also, fishing vessels with LED per automatic jigging machine achieved 71.8% of catches of that with MH fishing lamp. The catches of squids per the fishing vessel with 1W LED fishing lamp were higher by more than 135.5% of that in the fishing vessel with MH, which showed a good fishing performance even with only the use of a LED fishing lamp.

프리볼트입력용 메탈핼라이드램프 전자식안정기 개발 (Development of Electronic Ballast for Metal Halide Lamp wilts Free Voltage Input)

  • 김기정
    • 조명전기설비학회논문지
    • /
    • 제16권1호
    • /
    • pp.20-26
    • /
    • 2002
  • 고압방전램프에는 고압수은램프, 고압나트륨램프와 메탈핼라이프램프가 있다. 메탈핼라이드램프는 가장 효율 좋을 램프들 중 하나이며 고효율, 고연색성과 집광능력이 좋다. 이 연구의 목적은 AC 100∼277의 프리볼트입력용 전자식안정기를 개발하여 메탈핼라이드(MH70W)를 점등시키는 것이다. 개발된 전자식안정기는 프리볼트입력용컨버터, 플라이백컨버터와 하프브리지인버터, 이그나이터와 보호기 그리고 제어기로 구성되어 있다. 실험 결과 개발된 전자식안정기는 프리볼트입력(AC 100∼277V)에 따라 메탈핼라이드램프(MH70W)가 매우 잘 점등되었다.

가로등 화재사고의 원인규명과 검증 (Cause Investigation and Verification of Fire Accidents for Road and Street Lighting)

  • 송길목;한운기;김종민;김영석;김명수;김혁수
    • 한국화재조사학회논문지
    • /
    • 제11권1호
    • /
    • pp.31-36
    • /
    • 2008
  • 본 연구는 현장에서 발생한 가로등 화재에 대한 원인을 규명하기 위한 것으로 검증실험과 다양한 분석을 수행하였다. 이물질이 부착된 250W 메탈할라이드등은 $410.4^{\circ}C$로 급격하게 온도가 상승하였다. 따라서 환기 및 방진에 대한 개선이 요구된다. MH 램프에 의한 열은 발광판에서 유리구, 등기구로 이어지며 확산되었다. 메탈할라이드등의 사고원인은 등기구 내부의 이물질이 침적되어 축열 및 화재로 이어진 것으로 추정되며, 등기구의 설계에 있어서 외부 이물질 또는 분진이 침적되지 않으면서 축열이 되지 않는 구조 개선이 요구된다.

  • PDF

Electronic Ballast with Constant Power Output Controller for 250W MH Lamp

  • Jung Dong-Youl;Park Jong-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.332-337
    • /
    • 2006
  • In this paper, an electronic ballast was developed to control a 250W metal halide lamp. To avoid acoustic resonance phenomenon, we calculated the acoustic resonance band and determined the driving frequency from 70kHz to 100kHz. Due to the switching loss of MOSFET, many problems are caused in the inverter circuit during lamp lighting, so we reduced the loss by connecting the capacitor that minimizes the magnitude of the impulsive voltage. In this paper, the main point of research is to find the methods to operate the lamp on the rated output power. After detecting the current and the voltage of the lamp, we changed the driving frequency by adjusting the DC voltage level of the VCO input.

고효율 펄스스타트 메탈핼라이드램프(MH200W)의 음향공명현상감소 (Reduction of Acoustic Resonance Phenomena in Pulse Start MetalHalide Lamp (MH200W))

  • 김기정
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.8-14
    • /
    • 2001
  • 메탈핼라이드램프는 고효율, 고연색성이며 집광능력이 좋다. 그러나 메탈핼라이드 램프의 단점은 아크튜브내에서 음향공명현상이 발생되는 것으로 알려져 있다. 이러한 음향공명은 점등상태의 불안정과 기체의 심한 파동을 일으킨다. 심한 파동과 불안정한 점등으로 아크가 소멸되는 부위는 전압이 상승되고, 방전관내벽에 근접된 아크는 국부의 과열로 튜브를 금가게한다. 이 연구의 목적은 펄스스타트 메탈핼라이드램프 MH200[W]의 아크튜브내에서 음향공명을 감소시키는 것이다. 음향공명현상을 감소시키기 위하여 전자식안정기가 84.6[kHz]에서 94.2[kHz] 대역내에 있는 89[kHz]의 단독주파수인 정현고주파를 램프에 공급하기 위하여 설계되었다. 실험결과 고효율 펄스스타트 MH200[W] 램프의 방전관내에 음향공명 현상이 없었다.

  • PDF

식물생장용 고압나트륨램프와 메탈할라이드램프의 분광 광강도 분석 (Analysis of Spectral Light Intensity of High Pressure Sodium and Metal Halide Lamps for Plant Growth)

  • 이혜인;김용현;김동억
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.413-419
    • /
    • 2010
  • Plant growth was greatly affected by the spectral distribution and light intensity of artificial lighting sources. In this study, the spectral characteristics of high power sodium (HPS) lamps and metal halide (MH) lamps produced by three different manufacturers were measured. Even though the spectral distribution of HPS lamps with lamp wattage of 250 W and 400 W was very similar, but the spectral light intensity by the manufacturers was different. Difference in the spectral light intensity of MH lamps by the manufacturers was increased with the increasing lamps wattage. Light intensity at the region of blue (B), green (G), red (R) and far-red (FR) light of HPS and MH lamps was also analyzed. HPS lamps showed the light intensity in order of R, FR, B and G light. The ratio of G, B, R and FR to photosynthetic photon flux (PPF) of HPS lamps with the lamp wattage of 250 W was 3.0-3.2%, 5.5-5.9%, 17.3-19.2% and 6.5-7.8%, respectively. For MH lamps, it showed the light intensity in order of R, FR, B, and G. The ratio of B, G, R, and FR to PPF of MH lamps with 250 W was 14.0-15.5%, 22.6-27.5%, 7.5-9.5% and 2.7-4.2%, respectively. HPS and MH lamps with 400 W had a relatively smaller ratio of R and FR to PPF than those with 250 W. HPS lamps showed that the ratio of light intensity of B and FR to R was 0.15-0.28 and 0.36-0.4, respectively. For MH lamps, the ratio of light intensity of B and FR to R was 1.26-2.72 and 0.27-0.56, respectively. From these results, it was concluded that the portion of blue light of MH lamps was higher than those of HPS lamps.

The Development of the Buck Type Electronic Dimming Ballast for 250W MHL

  • Jung, Dong-Youl;Park, Chong-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.496-502
    • /
    • 2006
  • In this paper, we studied the development of the electronic ballast for 250W MH (Metal-Halide) lamps. We were able to improve the input power factor by using a PFC IC. To provide the lamp with the rated voltage required, we used the buck-type dc-dc converter. The stress of the switching devices in the inverter could be reduced by this method. To eliminate the acoustic resonance phenomena of MH lamps, the voltage of the lamp added the high frequency sine-wave to the low frequency square-wave by using the full bridge typed inverter. We have developed a simple igniter using the L and C elements. We could control the dimness of the lamp by varying the output voltage of the buck converter. The buck converter output voltage could be controlled by using a microprocessor.

Ceramic 메탈 헬라이드 램프용 Dimming 전자식 안정기 개발 (Design of Dimmable electric ballast for the Ceramic metal halide lamp)

  • 임기승;최현희;신동석;박종연
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1947-1953
    • /
    • 2009
  • Metal halide (MH) lamps have been largely used due to high luminous efficiency, good color rendering, and long life. Since the metal halide lamps have problems of high ignition voltage and acoustic resonance. Thus, the design of ballast is very difficult for engineers. This paper proposes prototype of electric ballast in order to solve above two problems. The proposed electric ballast is consisted of EMI filter, full wave rectifier circuit, active PFC, DBI(Dual Buck Inverter), dimming circuit and ignitor circuit. The DBI supplies both rectangular voltage and current to the lamp. As the result of the experiment, the acoustic resonance was eliminated and the ignitor circuit was designed to generate high ignition voltage than 5kV. It makes the dimming circuit possible to control the lamp power in range between 230W and 350W.