• Title/Summary/Keyword: MG paper

Search Result 1,083, Processing Time 0.032 seconds

Carboxylic Acids Produced from Hydrothermal Treatment of Organic Wastes (유기성 폐기물의 고온고압수 반응에 의한 카르복시산 생성)

  • 강길윤;오창섭;김용하
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.228-233
    • /
    • 2004
  • This paper reports production of low-molecular weight carboxylic acids from the hydrothermal treatment of representative organic wastes and compounds with or without oxidant (H$_2$O$_2$). Organic acids such as acetic, formic, succinic and lactic acids were obtained. This result increased to 42mg/g dry waste fish entrails in the presence of H$_2$O$_2$. Experiments on glucose representing cellulosic wastes were also carried out, getting acetic acid of about 29mg/g glucose. Studies on temperature dependance of formation of organic acids showed thermal stability of acetic acid, whereas, formic acid decomposed readily under hydrothermal conditions. In general. results demonstrated that the presence of oxidants favored formation of organic acids with acetic acid being the major product.

An Empirical Study on Autonomous Operation in Emergency Situation of Microgrids (마이크로그리드의 비상상황시 자율 대처 운전 방안에 관한 실증적 연구)

  • Hong, Ji-Song;Kim, Hyun-Woo;Ahn, Seon-Ju;Choi, Joon-Ho;Yun, Sang-Yun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1595-1601
    • /
    • 2018
  • The biggest obstacle to the commercialization of small and medium size microgrid (MG) is the reliability and economics of MG operation and maintenance. In this paper, we propose an autonomous operation method that is implemented as an application program installed in the MG operating system in emergency situations. The proposed algorithm consists of four steps of distinction, recognition, determination and control of emergency situations that can occur in MG. A fuzzy-based situation decision algorithm has been proposed to eliminate the barriers of autonomous operation in actual emergency situation such as occurrence of bad data and communication delay. In addition, countermeasures have been suggested for cases where multiple emergency situations have occurred in combination. The proposed algorithm was tested in a 500kW actual microgrid site of a university. Through the test, the validity of the proposed method and its applicability to practical MG operation are verified.

Effect of Ce0.9Gd0.1O1.95 as a promoter upon the oxygen transfer properties of MgMnO3-δ-Ce0.9Gd0.1O1.95 composite oxygen carrier materials for chemical looping combustion

  • Hwang, Jong Ha;Lee, Ki-Tae
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.1
    • /
    • pp.18-23
    • /
    • 2019
  • Chemical looping combustion (CLC) is a promising carbon capture and storage (CCS) technology whose efficiency and cost primarily relies on the oxygen carrier materials used. In this paper, gadolinium-doped ceria (GDC, Ce0.9Gd0.1O1.95) was added as a promoter to improve the oxygen transfer rate of MgMnO3-δ oxygen carrier materials. Increasing GDC content significantly increased the oxygen transfer rate of MgMnO3-δ-GDC composites for the reduction reaction due to an increase in the surface adsorption of CH4 via oxygen vacancies formed on the surface of the GDC. On the other hand, the oxygen transfer rate for the oxidation reaction decreased linearly with increasing GDC content due to the oxygen storage ability of GDC. Adsorbed oxygen molecules preferentially insert themselves into oxygen vacancies of the GDC lattice rather than reacting with (Mg,Mn)O to form MgMnO3-δ during the oxidation reaction.

Feasibility Study of the Introduction of Hydrogen System and Plus DR on Campus MG

  • Woo, Gyuha;Park, Soojin;Yoon, Yongbeum
    • New & Renewable Energy
    • /
    • v.18 no.1
    • /
    • pp.35-45
    • /
    • 2022
  • The renewable energy based MG is becoming one of the prominent solutions for greenhouse gas and constructing less power lines. However, how to procure the economics of MG considering the CO2 emission and utility network impact is one of major issues as the proportion of renewable resource increases. This paper proposes the feasibility study scheme of campus MG and shows that the LCOE and CO2 emission can be reduced by utilizing the excess power and introducing hydrogen system and plus DR. For this, the three cases: (a) adding the PV and selling excess power to utility, (b) producing and selling hydrogen using excess power, and (c) participating in plus DR are considered. For each case, not only the topology and component capacity of MG to secure economic feasibility, but also CO2 emission and utility network effects are derived. If an electrolyzer with a capacity of 400 kW participates in plus DR for 3,730hours/year, the economic feasibility is securable if plus DR settlement and hydrogen sale price are more than 7.08¢/kWh and 8.3USD/kg or 6.25¢/kWh and 8.6USD/kg, respectively. For this end, continuous technical development and policy support for hydrogen system and plus DR are required.

Estimation of Phosphorus Adsorption Capacity of Alum-amended and Composted Paper Mill Sludge (제지슬러지에 대한 alum 처리 및 퇴비화에 따른 인 흡착능 변화)

  • Lee, In-Bog;Chang, Ki-Woon;Park, Jin-Myeon
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.2
    • /
    • pp.124-130
    • /
    • 2007
  • Excess application of paper mill sludge (PMS) in field can limit phosphorus uptake by crops because aluminum presented in the sludge can fix or adsorb available phosphorus which is necessary for crop growth. To investigate phosphorus (P) adsorption characteristics of PMS, we examined P adsorption maximum $(X_m)$ using Langmuir isotherm and P adsorption energy constant $(K_f)$ using Freundlich isotherm for PMS without alum, PMS with alum, and composted PMS with alum through a laboratory incubation test. The maximum P adsorption capacities were 800 ${\mu}g\;g^{-1}$ in soil, 47 $mg\;g^{-1}$ in PMS without alum and 61 $mg\;g^{-1}$ in PMS with alum. P adsorption capacity with alum treatment for PMS increased by 30%. That of PMS compost was 68 $mg\;g^{-1}$ and showed that composting increases 11% of P adsorption. Freundlich constant $K_f$ was 22 in check soil, while $K_f$ values in PMS without alum and in PMS with alum were 398 and 426, respectively. After composting, $K_f$ value of PMS compost significantly increased as 1,819. In conclusions, p adsorption capacity for PMS were increased by alum treatment or composting and therefore excess or continuous land application of alum-amended or composted PMS can limit P uptake for crops by reducing available P in sell.

Antimicrobial Effect of Ethanol Extract of Dryopteris crassirhizoma Nakai on Propionibacterium acnes (관중(Dryopteris crassirhizoma Nakai) 추출물의 Propionibacterium acnes에 대한 항균 효과)

  • Yoon, Chang-Soon;Kim, Hyun-Ju;Lim, Hye-Won;Choi, Shin-Wook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.3 s.58
    • /
    • pp.201-208
    • /
    • 2006
  • Propionibacterium acnes have been recognized as pus-forming bacteria triggering an inflammation in acne. The present study was conducted to evaluate antimicrobial activities of Dryopteris crassirhizoma Nakai against these etiologic agents of acne vulgaris and application possibility as a cosmetic resource. D. crassirhizoma crude extract and hexane fraction was prepared and its anti-acne effect against Propionibacterium acnes was investigated with minimum inhibitory concentration (MIC) and paper disk diffusion method. The MIC of D. crassirhizoma crude extract and hexane fraction was 0.008 mg/mL and 0.001 mg/mL, respectively. This implies that D. crassirhizoma extract may be an efficient anti-acne ingredient for cosmetics, as a crude extract. The paper disk diffusion assay showed that its anti-acne effect was similar to that of triclosan. The cytotoxic effect of D. crassirhizoma extract was determined by a colorimetric MTT assay using HaCaT cell line and D. crassirhizoma extract exhibited lower cytotoxic effects. Finally, we examine the stability of D. crassirhizoma extract to temperature and pH. The D. crassirhizoma extract was very stable to high temperatures ($25{\sim}121^{\circ}C$) and to wide pH range ($pH\; 2{\sim}11$), suggesting its utilization for cosmetics.

Assessment of Technology Based Industrial Wastewater Effluent Limitation and Standards for the Domestic Industry Category (III) : The Evaluation of TBEL's Applicability for Domestic Industry Categories (Case-study : Pulp, Paper, Paperboard Category) (처리기술에 근거한 산업폐수 배출허용기준 국내 적용성 연구(III) : 국내 적용방안 및 사례 연구 (펄프·종이 및 종이제품 제조시설))

  • Kim, Kyeongjin;Son, Daehee;Heo, Jin;Kim, Kwangin;Kim, Sanghun;Kim, Jaehun;Yeom, Icktae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.377-386
    • /
    • 2010
  • Introduction of TBELs into Korean environmental regulatory system for wastewater may require very careful considerations and appropriate modifications of the TBELs applied in US. The Korean regulations for wastewater are based on uniform regulatory criteria for wastewater effluent discharge and are quite different from the individual permit system in US. In addition, the toxic pollutants regulated in Korea are much less than those in US. Therefore, the effects of TBELs application on the pollutants reduction and the economic feasibility should be carefully assessed for different categories of wastewater sources. In this study, the applicability of TBELs for the industrial categories of Korea was discussed. The TBELs were derived for a sample category, the pulp paper paperboard manufacture, based on the previously reported analytical data from 52 facilities of the domestic pulp paper paperboard manufacture in Korea. It was suggested that the BAT effluent limitations were BOD 30 mg/L, $COD_{Mn}$ 40 mg/L, SS 40 mg/L, T-N 30 mg/L and T-P 4 mg/L and that the allowable effluent loads were $0.31{\sim}1.75kgCOD_{Mn}/ton$-products. Due to the limitation of insufficient data, there were difficult to obtain the important factors to derive more systematic and accurate limitation standards for the pollutants such as the 'Long Term Average (LTA)', the 'Product Normalized Discharge Flow (PNDF)', and the 'Variability Factor (VF)'. However, as the first trial of TBELs determination based on the all available analytical data reported, the procedure and the outcome of the study may provide valuable insight on application of TBELs in Korea.

Electrical Insulation Properties of Nanocomposites with SiO2 and MgO Filler

  • Jeong, In-Bum;Kim, Joung-Sik;Lee, Jong-Yong;Hong, Jin-Woong;Shin, Jong-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.6
    • /
    • pp.261-265
    • /
    • 2010
  • In this paper, we attempt to improve the electrical characteristics of epoxy resin at high temperature (above $80^{\circ}C$) by adding magnesium oxide (MgO), which has high thermal conductivity. Scanning electron microscopy (SEM) of the dispersion of specimens with added MgO reveals that they are evenly dispersed without concentration. The dielectric breakdown characteristics of $SiO_2$ and MgO nanocomposites are tested by measurements at different temperatures to investigate the filler's effect on the dielectric breakdown characteristics. The dielectric breakdown strength of specimens with added $SiO_2$ decreases slowly below $80^{\circ}C$ (low temperature) but decreases rapidly above $80^{\circ}C$ (high temperature). However, the gradient of the dielectric breakdown strength of specimens with added MgO is slow at both low and high temperatures. The dielectric breakdown strength of specimens with 0.4 wt% $SiO_2$ is the best among the specimens with added $SiO_2$, and that of specimens with 3.0 wt% and 5.0 wt% MgO is the best among those with added MgO. Moreover, the dielectric strength of specimens with 3.0 wt% MgO at high temperatures is approximately 53.3% higher than that of specimens with added $SiO_2$ at $100^{\circ}C$, and that of specimens with 5.0 wt% of MgO is approximately 59.34% higher under the same conditions. The dielectric strength of MgO is believed to be superior to that of $SiO_2$ owing to enhanced thermal radiation because the thermal conductivity rate of MgO (approximately 42 $W/m{\cdot}K$) is approximately 32 times higher than that of $SiO_2$ (approximately 1.3 $W/m{\cdot}K$). We also confirmed that the allowable breakdown strength of specimens with added MgO at $100^{\circ}C$ is within the error range when the breakdown probability of all specimens is 40%. A breakdown probability of up to 40% represents a stable dielectric strength in machinery and apparatus design.

Recycled packed-bed reactor for efficient denitrification (재순환 충전탑식 반응기를 이용한 효율적 탈질)

  • 김성홍;송승훈;박재연;유영제
    • KSBB Journal
    • /
    • v.19 no.2
    • /
    • pp.154-158
    • /
    • 2004
  • Recycled packed-bed reactor emploring immobilized microorganism was suggested in this paper for efficient denitrification. In the batch reactor, the effects of initial oxidation-reduction potential and nitrate concentration on denitrification were investigated. As the initial oxidation-reduction potential was decresed to -70 mV from +40 mV, the removal rate of nitrate was increased to 3.33 from 1.25 m9 NO$_3$$\^$-/-N/min under the experimental conditions. As the initial nitrate-N concentraion was increased to 200 mg/l, the removal rate of nitrate was proportional to the concentration of nitrate. When the concentration of nitrate-N was 400 mg/min, nitrite was detected, and when the initial nitrate-N concentration was reached at 1,000 mg/l, it took longer time for the complete nitrate removal. In order to decrease the initial oxidation-reduction potential and the nitrate-N concentration in the feed stream, the effluent was recycled to the influent stream in the packed-bed reactor. In the case of recycling, the initial oxidation-reduction potential was decreased to 30 mV from 150 mV, and the initial nitrate concentration could be decreased to 85 from 120 mg NO$_3$$\^$-/-N/l. As the result of recycling, the removal rate of nitrate was increased to 91.7% from 49.2%.

ANALYSIS OF THE LiF:Mg,Cu,Si TL AND THE LiF:Mg,Cu,P TL GLOW CURVES BY USING GENERAL APPROXIMATION PLUS MODEL

  • Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul;Oh, Mi-Ae;Chung, Ki-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.155-164
    • /
    • 2009
  • In this paper, we used computerized glow curve deconvolution (CGCD) software with several models for the simulation of a TL glow curve which was used for analysis. By using the general approximation plus model, parameters values of the glow curve were analyzed and compared with the other models parameters (general approximation, mixed order kinetics, general order kinetics). The LiF:Mg,Cu,Si and the LiF:Mg,Cu,P material were used for the glow curve analysis. And we based on figure of merits (FOM) which was the goodness of the fitting that was monitored through the value between analysis model and TLD materials. The ideal value of FOM is 0 which represents a perfect fit. The main glow peak makes the most effect of radiation dose assessment of TLD materials. The main peak of the LiF:Mg,Cu,Si materials has a intensity rate 80.76% of the whole TL glow intensity, and that of LiF:Mg,Cu,P materials has a intensity rate 68.07% of the whole TL glow intensity. The activation energy of LiF:Mg,Cu,Si was analyzed as 2.39 eV by result of the general approximation plus(GAP) model. In the case of mixed order kinetics (MOK), the activation energy was analyzed as 2.29 eV. The activation energy was analyzed as 2.38 eV by the general order kinetics (GOK) model. In the case of LiF:Mg,Cu,P TLD, the activation energy was analyzed as 2.39 eV by result of the GAP model. In the case of MOK, the activation energy was analyzed as 2.55 eV. The activation energy was analyzed as 2.51 eV by the GOK model. The R value means different ratio of retrapping-recombination. The R value of LiF:Mg,Cu,Si TLD main peak analyzed as $1.12\times10^{-6}$ and $\alpha$ value analyzed as $1.0\times10^{-3}$. The R of LiF:Mg,Cu,P TLD analyzed as $7.91\times10^{-4}$, the $\alpha$ value means different ratio of initial thermally trapped electron density-initial trapped electron density (include thermally disconnected trap electrons density). The $\alpha$ value was analyzed as $9.17\times10^{-1}$ which was the difference from LiF:Mg,Cu,Si TLD. The deep trap electron density of LiF:Mg,Cu,Si was higher than the deep trap electron density of LiF:Mg,Cu,P.