• Title/Summary/Keyword: MFL

Search Result 92, Processing Time 0.024 seconds

A Study on the Measurement of Axial Cracks in the Magnetic Flux Leakage NDT System (자기누설 비파괴 검사 시스템에서 축방향 미소결함 측정에 관한 연구)

  • Kim, Hui-Min;Park, Gwan-Soo;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu;Koo, Sung-Ja
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • From among the NDT (Non-Destructive Testing) methods, the MFL (Magnetic Flux Leakage) PIG (Pipeline Inspection Gauge) is especially suitable for testing pipelines because the pipeline has high magnetic permeability. MFL PIG showed high performance in detecting the metal loss and corrosions. However, MFL PIG is difficult to detect the crack which occured by exterior-interior pressure difference in pipelines and the shape of crack is very long and narrow. Therefore, the new PIG is needed to be researched and developed for detecting the cracks. The CMFL (Circumferential MF) PIG performs magnetic fields circumferentially and can maximize the magnetic flux leakage at the cracks. In this paper, CMFL PIG is designed and the distribution of the magnetic fields is analyzed by using 3 dimensional nonlinear finite element method (FEM). By Simulating and Measuring the magnetic leakage field, it is possible to detect of axial cracks in the pipeline.

Development of a Novel Medium with Chinese Cabbage Extract and Optimized Fermentation Conditions for the Cultivation of Leuconostoc citreum GR1 (폐배추 추출물을 이용한 Leuconostoc citreum GR1 종균 배양용 최적 배지 및 배양 조건 개발)

  • Moon, Shin-Hye;Chang, Hae-Choon;Kim, In-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.7
    • /
    • pp.1125-1132
    • /
    • 2013
  • In the kimchi manufacturing process, the starter is cultured on a large-scale and needs to be supplied at a low price to kimchi factories. However, current high costs associated with the culture of lactic acid bacteria for the starter, have led to rising kimchi prices. To solve this problem, the development of a new medium for culturing lactic acid bacteria was studied. The base materials of a this novel medium consisted of Chinese cabbage extract, a carbon source, a nitrogen source, and inorganic salts. The optimal composition of this medium was determined to be 30% Chinese cabbage extract, 2% maltose, 0.25% yeast extract, and $2{\times}$ salt stock (2% sodium acetate trihydrate, 0.8% disodium hydrogen phosphate, 0.8% sodium citrate, 0.8% ammonium sulfate, 0.04% magnesium sulfate, 0.02% manganese sulfate). The newly developed medium was named MFL (medium for lactic acid bacteria). After culture for 24 hr at $30^{\circ}C$, the CFU/mL of Leuconostoc (Leuc.) citreum GR1 in MRS and MFL was $3.41{\times}10^9$ and $7.49{\times}10^9$, respectively. The number of cells in the MFL medium was 2.2 times higher than their number in the MRS media. In a scale-up process using this optimized medium, the fermentation conditions for Leuc. citreum GR1 were tested in a 2 L working volume using a 5 L jar fermentor at $30^{\circ}C$. At an impeller speed of 50 rpm (without pH control), the viable cell count was $8.60{\times}10^9$ CFU/mL. From studies on pH-stat control fermentation, the optimal pH and regulating agent was determined to be 6.8 and NaOH, respectively. At an impeller speed of 50 rpm with pH control, the viable cell count was $11.42{\times}10^9(1.14{\times}10^{10})$ CFU/mL after cultivation for 20 hr - a value was 3.34 times higher than that obtained using the MRS media in biomass production. This MFL media is expected to have economic advantages for the cultivation of Leuc. citreum GR1 as a starter for kimchi production.

Implementation of High Magnetization System for Performance Enhancement of Magnetic Flux Leakage Tool

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Kim, Dong-Ku;Park, Dae-Jin;Rho, Yong-Woo;Seo, Kang;Park, Gwan-Soo;Choi, Doo-Hyun;Song, Sung-Jin
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.199-203
    • /
    • 2010
  • This paper discusses the effectiveness of high magnetization saturation in ILI (In-Line Inspection) using an MFL (Magnetic Flux Leakage) tool, and introduces a practical method for improving the magnetization level together with the piggability. Thin steel plates, replacing the conventional wire brushes were used as conductors to transfer the magnetic flux to the pipe wall. The newly designed MFL tool was compared with the conventional version by means of FEM (Finite Element Method) analysis and full-scale experiments. In the results, the newly developed magnetization system obtained a stronger MFL signal amplitude, specially 2.7 times stronger, than that obtained by the conventional magnetization system for the same defect dimensions.

Magnetic Flux Leakage based Damage Quantification of Steel Bar (누설자속기법을 이용한 강봉의 손상 정량화 기법)

  • Park, Jooyoung;Kim, Ju-Won;Yu, Byoungjoon;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • In this paper, a magnetic flux leakage(MFL) based steel bar damage detection was first researched to quantify the signals from damages on the wire rope. Though many researches inspecting damages using a MFL method was proceeded until the present, the researches are at the level that diagnose whether damages are or not. This has limitation to take measures in accordance with the damage level. Thus, a MFL inspection system was modeled using a finite element analysis(FEM) program dealing with electromagnetism problems, and a steel bar specimen was adopted as a ferromagnetic object. Then, an experimental study was also carried out to verify the simulation results with a steel bar which has same damage conditions as the simulation. The MFL signals was nearly not affected by the increase of the inspection velocity, and the magnitudes of the signals are not identical according to the change of the defect width even the defects have same depth. On the basis of the analysis, the signal properties from the damages were extracted to classify the type of damages, and it could be confirmed that classification of damages using extracted signal properties is feasible.

Suppression of IgE and GATA-3-dependent Th2 Cell Regulation by PM-E and PM-70M Isolated Polygonum Multiflorum (하수오에서 분리한 PM-E와 PM-70M이 GATA-3의존성 Th2세포 조절과 IgE 억제 효과)

  • Choi, Eun-Young
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.8
    • /
    • pp.274-281
    • /
    • 2019
  • This study examined the effects of GATA-3-dependent Th2 cells and IgE inhibition by using PM-E and PM-70M isolated from Sasao. It was analyzed that the 70 % methanol layer contained adsorbed chromatograms of the fraction of sodium hypochlorite that inhibited GATA-3 transcription factor activity. As a result, PM-70 %MFL fraction seems to have an antiallergic effect by inhibiting GATA-3 which regulates Th2 cytokine. PM-30A, PM-70A, and PM-30A layers by inhibiting IgE secretion in B cells by co-culturing the fractions with anti-CD40/rmIL-6 and TNF-${\alpha}$ mRNA and IgE were not different from control. However, expression of IL-6 and TNF-${\alpha}$ mRNA was $0.69{\pm}0.058$ (p<0.001) and $0.72{\pm}0.58$ (p<0.05), respectively. The amount of IgE secretion was $94.6{\pm}16.0$, which was significantly decreased by 45.6% (p<0.01) compared with the control group. This study suggests that the PM-70% MFL layer in the fraction of Sasao contains the components that inhibit the differentiation and activity of B cells.

Study on the Distortion of Detecting Signals with the Multi-Defects in Magnetic Flux Leakage System (자기누설탐상시스템에서 밀집된 다수의 결함에 의한 탐상 신호 왜곡에 관한 연구)

  • Seo, Kang;Kim, Dug-Gun;Han, Jea-Man;Park, Gwan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.876-883
    • /
    • 2007
  • The magnetic flux leakage(MFL) type nondestructive testing(NDT) method is widely used to detect corrosion, defects and mechanical deformation of the underground gas pipelines. The object pipeline is magnetically saturated by the magnetic system with permanent magnet and yokes. Hall sensors detect the leakage fields in the region of the defect. The defects are sometimes occurred in group. The accuracy of the detecting signals in this defect cluster become lowered because of the complexity of the defect cluster. In this paper, the effects of the multi -defects are analyzed. The detecting signals are computed by 3-dimensional finite element method and compared with real measurement. The results say that, rather than the size of the defects, the effects of the relative position of the multi-defects are very important on the detecting signals.