• 제목/요약/키워드: MDCT images

검색결과 54건 처리시간 0.024초

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • 제31권1호
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

Multidetector-Row Computed Tomography (MDCT) Coronary Agniography에서 Arrhythmia Correction이 영상의 질에 미치는 영향에 관한 연구 (Evaluation of the Effect of the Arrhythmia Correction for the Image Quality in the Multidetector-Row Computed Tomography (MDCT) Coronary Angiography)

  • 김현수;김긍식;김태훈;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권2호
    • /
    • pp.7-12
    • /
    • 2004
  • MDCT는 비침습적인 방법으로 관상동맥 질환을 검사하는데 유용하다고 알려져 있다. 하지만 영상의 질에 있어서 환자의 심장박동이 결정적인 영향을 주게 된다. 특히 심장박동이 불규칙하거나 조기 심실수축 환자일 경우 영상을 재구성하는데 있어 왜곡 현상이 증가하여 진단에 어려움을 초래한다. 최근 본원에서 심장박동이 불규칙한 환자에서 영상 재구성시 불규칙한 R-R 간격을 조정한 후 얻은 영상이 artifact가 감소하는 현상을 경험한 바 있다. 따라서 본 연구에서는 다양한 교정 방법(disable, inesrt, R-R interval 교정)이 영상의 질에 어떤 영향이 있는지를 알아보고자 한다. 심박동이 불규칙한 24명의 환자에서 교정방법에 따라 영상을 재구성한 결과 R-R Interval 조정에서 통계학적으로 유의한 결과를 얻을 수 있었다(p<0.05). 본 연구에서는 R-R Interval 조정에서 가장 우수한 영상을 얻을 수 있었으며, 향후 심장 질환의 진단에 도움을 줄 수 있는 기초연구로서 그 가치가 충분하리라 사료된다.

  • PDF

Prognostic factors for maxillary sinus mucosal thickening following Le Fort I osteotomy: a retrospective analysis

  • Iwamoto, Masashi;Watanabe, Miki;Yamamoto, Masae;Narita, Masato;Kamio, Takashi;Takaki, Takashi;Shibahara, Takahiko;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.12.1-12.5
    • /
    • 2019
  • Background: Le Fort I osteotomy is one of the surgical procedures now routinely and safely performed. It is possible to move the maxilla in three dimensions, but it is necessary to separate the bones around the maxillary sinus. Therefore, with surgery, maxillary sinus mucosal thickening occurs. By knowing the changes in the sinus mucosa after surgery and the factors affecting it, it is possible to better predict the outcomes of surgery and contribute to safer surgery. In this study, thickening of maxillary sinus mucosa before and after surgery in Le Fort I osteotomy was evaluated using multidetector-row computed tomography (MDCT) images, and the changes in mucosal thickening and the related factors were examined. Methods: Using MDCT images, the maxillary sinus mucosa of 125 patients who had undergone Le Fort I osteotomy was retrospectively evaluated before surgery, 1 month after surgery, and 1 year after surgery. On the MDCT images, the maxillary sinus was judged as mucosal thickening and classified into three grades according to the proportion occupying the maxillary sinus. In the evaluation of factors related to mucosal thickening, the following eight factors were examined: sex, age, diagnosis, operating time, amount of postoperative bleeding, with/without bone graft, with/without multisegmental osteotomy, and with/without macrolide therapy after surgery. Results: The mean age at the time of surgery was 25.6 ± 8 years. Of all 125 patients, 66 had bilateral thickening, 19 had unilateral thickening, and 40 had no thickening. Factors that were significantly related to mucosal thickening were the operative time for the maxilla, bone grafts, and macrolide therapy after surgery. Conclusions: Operative time for the maxilla, bone grafts, and macrolide therapy after surgery were found to be related to mucosal thickening. In addition, MDCT scanning 1 month after surgery was considered to be appropriate for evaluation of maxillary sinus mucosal thickening.

Edge Detection을 이용한 간 혈관 추출 (Hepatic Vessel Segmentation using Edge Detection)

  • 서정주;박종원
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권3호
    • /
    • pp.51-57
    • /
    • 2012
  • 간 혈관 구조는 간에 대한 질병을 판단하거나 간 수술 계획을 세우는 데 중요한 요소이다. 특히 생체간이식에서 간 혈관 구조는 기증자와 수혜자의 안전을 보장하기 위하여 수술 전 환자의 간 상태를 파악하고 좌우엽의 체적을 계산하는 중요한 근거로 활용된다. 본 연구는 조영제를 투여한 복부 MDCT 영상에서 추출된 간 영상으로부터 간 혈관을 자동추출하기 위하여 노이즈에 강한 Canny edge detection을 활용할 수 있는 방안을 제안한다. 환자마다 달라질 수 있는 간 영상의 밝기와는 독립적으로 간 내부의 혈관을 추출하기 위하여 간 영상의 히스토그램과 평균 픽셀값을 이용하여 Canny 알고리즘에 사용되는 최적의 파라미터들을 정의한다. 간 영상의 밝기에 따라 파라미터를 수동으로 조절하는 경우보다 시간을 절약할 수 있다. 찾아진 혈관의 경계선에서픽셀의 밝기를 이용하여 후보 혈관을 추출한다. 최종적으로 수평과 수직방향으로 연결된 혈관이나 고립된 혈관을 검색하는 시스템을 이용하여 추출에 실패한 혈관을 추가하고 노이즈를 제거한다. 그 결과로써 환자마다 나타나는 다양한 혈관 모양을 정확하게 3차원으로 재구성한다.

Variations in Entrance of Vertebral Artery in Korean Cervical Spine: MDCT-based Analysis

  • Shin, Hye Young;Park, Ji Kang;Park, Sun Kyung;Jung, Gyu Seo;Choi, Yun Suk
    • The Korean Journal of Pain
    • /
    • 제27권3호
    • /
    • pp.266-270
    • /
    • 2014
  • Background: Knowledge of the anatomical variation of the vertebral artery has clinical importance not only for the performance of interventional or surgical procedures itself but also to ensure their safety. We conducted a study of the anatomical variation by reviewing multi-detector computed tomography (MDCT) images of the cervical spine from 460 Korean patients. Methods: 16-row MDCT data from 460 patients were used in this study. We observed 920 vertebral arteries. Examination points included level of entrance of the artery into the transverse foramen of the cervical vertebra, origin site of the vertebral artery, course of a vertebral artery with aberrant entrance. Result: The vertebral artery in 2 (0.2%) cases in this study entered into the transverse foramen of the 7th cervical vertebra from the left. In 45 (4.9%) cases, the vertebral artery entered into the transverse foramen of the 5th cervical vertebra. Of these, the entrance was on the right in 15 (1.6%) and on the left in 30 (3.3%). We found 17 (1.8%) cases in which the artery entered into the transverse foramen of the 4th cervical vertebra, 10 (1.1%) on the right and 7 (0.7%) on the left side. As is commonly acknowledged, the 6th cervical vertebra was the most common site of entry; the vertebral artery entered the transverse foramen of the 6th cervical vertebra in the remaining 855 (93.0%) cases, on the right in 434 (47.2%) and on the left in 421 (45.8%). Conclusions: In conclusion, the possibility of an atypical course of the vertebral artery in segments V1 and V2 should be evaluated with magnetic resonance imaging (MRI) or CT images before carrying out procedures involving the anterior cervical vertebrae.

Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교 (Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography)

  • 유병규;이종석;장근조;전상환;김용수;권대철
    • Journal of Radiation Protection and Research
    • /
    • 제32권3호
    • /
    • pp.123-133
    • /
    • 2007
  • 하지 정맥류 질환 환자를 대상으로 하지 정맥조영술 MDCT 검사에서 환자의 피폭선량을 최소화 하면서 최적의 진단영상을 묘출하기 위해 고정 관전류 기법과 Z-축 자동 관전류 변동 제어를 이용하여 CTDIvol(CT dose index volume), DLP(dose length product) 산출을 통한 영상의 노이즈를 측정하여 비교하였다. Monte Carlo simulation으로 200, 250, 300 mA에서 CTDIw, CTDIvol, DLP를 계산하여 고정 관전류 기법과 비교하였다. 고정 관전류 기법의 대상 환자는 50명(평균 나이, 46세; 연령 범위, 35-61세)으로 남성30명, 여성 20명 이었고, 평균 체중은 62.4 kg 이었다. Z-축 자동 관전류 변동 제어 대상 환자는 50명(평균 나이, 43세; 범위, 37-63세)으로 남성25명, 여성 25명 이었고 평균 체중은 60.1 kg 이었다. 고정 관전류 기법은 200, 250, 300 mA를 기준으로 하고, Z-축 자동 관전류 변동 제어는 노이즈 지수 10, 11, 12 HU에서 관전류 $70{\sim}450\;mA$ 범위 내에서 자동으로 선택하였다. 고정 관전류 기법과 Monte Carlo simulation 비교에서 200 mA에서의 CTDIvol은 차이가 없었으나, 250 mA, 300 mA 에서의 Monte Carlo simulation는 높았고, DLP는 모든 관전류에서 Monte Carlo simulation이 높게 측정 되었다. 노이즈는 고정 관전류에서 최소 $9.8{\pm}0.9\;HU$, 최대 $12.5{\pm}0.7\;HU$ 이었고, Z-축 자동 관전류 변동 제어에서는 최소 $11.3{\pm}0.8\;HU$, 최대 $12.9{\pm}0.7\;HU$이었다. Z-축 자동 관전류 변동 제어에서 노이즈 지수가 증가하면 CTDIvol과 DLP가 감소하였으나 노이즈는 증가하였다. 생식부위를 포함하는 하지 정맥조영술에서 Z-축 자동 관전류 변동 제어 방법이 고정 관전류 기법에 비해 선량을 감소하는 효과가 있었다.

좌내흉동맥과 복재정맥편을 사용한 관상동맥우회로술 환자에서의 추적조사에서 MDCT의 유용성 (Effectiveness of MDCT for the Followup of CABG Patients with LIMA to LAD and Saphenous Veins to Others)

  • 강준규;김형태;박인덕;정영미;이철주
    • Journal of Chest Surgery
    • /
    • 제38권6호
    • /
    • pp.410-414
    • /
    • 2005
  • 관상동맥우회로술 시에 이식편으로 사용되는 혈관들의 조합은 다양하다. 또한 수술 후의 장기 추적조사에 침습적인 관상동맥조영술을 이용하는데는 제한이 되어왔다. 본 연구에서는 좌내흉동맥을 좌전하행지에, 나머지의 목표혈관에는 복재정맥편을 사용하는 고전적인 방법으로 수술한 환자들에서 외래에서 비침습적인 MDCT로 이식편의 개존유무를 수술자의 입장에서 확인하는 방법의 유용성을 평가하고자 하였다. 대상 및 방법: 아주대학교의료원 흉부외과에서 1995년부터 2003년 사이에 다중관상동맥질환으로 관상동맥우회로술을 받았던 환자들 중 외래추적조사에서 특별한 증세의 재발을 호소하지 않았던 환자들을 대상으로 환자의 동의 하에 16 Channel MDCT를 시행하였던 80명의 환자들을 대상으로 이식도관의 개존성을 분석하였다. 결과: 대상환자 중 남녀비는 61:19였으며 평균연령은 $58.9\pm8.9$세였다. MDCT의 촬영시점은 최소 수술 후 7일에서 수술 후 9년으로 중앙값은 6.5년이었다. 환자당 평균 $3.10\pm1.9$개의 도관이 이식되었다. 좌전하행지에 좌내흉동맥을 72명의 환자에 이식하였고, 나머지의 목표혈관에는 복재정맥편을 이식하였다. 복재정맥편의 목표혈관은 좌전하행지 8예, 우관상동맥에 47예, 둔각지에 61예, 대각지에 60예를 각각 이식하였으며, 이중 42예에서 연속문합을 시행하였다. 이식편의 5년개존율이 좌내흉동맥이 $93.1\%$였고 복재정맥괸이 $89.3\%$였다 복재정맥편의 목표혈관별 5년개존율은 대각지 $94.9\%$, 둔각지$92.1\%$, 그리고 우관상동맥이 $79.2\%$순이었다. 복재정맥편의 경우 단독문합의 페쇄율이 $5\~21.3\%$로 연속문합의 $4.8\%$에 비해 높았다. 걸론: 관상동맥우회로 술 후에 외래추적기간 중 시행한 MDCT는 이식도관의 개존을 확인하는데 효과적이었으며, 향후 영상의 해상도가 높아지면 관상동맥의 질환을 진단하는데도 크게 기여할 것으로 기대된다. 본 조사의 결과에 의하면 관상동맥우회로술시에 좌내흉동맥과 복재정맥편을 혼용한 수술의 결과는 만족한 것으로 판단된다.

복부 MDCT 영상으로부터 간혈관 자동 추출 알고리즘 (Auto-Segmentation Algorithm For Liver-Vessel From Abdominal MDCT Image)

  • 박성미;이유진;박종원
    • 한국멀티미디어학회논문지
    • /
    • 제13권3호
    • /
    • pp.430-437
    • /
    • 2010
  • 간이식 수술을 함에 있어서 간 내부의 혈관의 형태를 알고 시작하는 것이 수술의 성공률을 매우 높일 수 있다. 본 논문은 조영제를 투여한 정상 환자의 복부 MDCT를 이용하여 얻어진 영상을 다른 여러 장기부분은 제거하고 간 영상만을 추출한 후 간 내의 혈관들의 기본형태를 파악하여 몇몇 구조단위들을 만들고 Morphological filtering을 이용하여 주요 혈관인 좌, 우, 중간정맥을 찾아낸다. 중간정맥을 기준으로 간 실질을 절단하여 절단된 부분의 크기를 예측하고 수술전에 전체 상황을 파악하기 위한 연구이다. 간의 추출 방법은 명암값의 범위와 분포 샘플링 과정에 의한 명암값 분포비율을 가지고 배경과 근육층을 제거하였다. 간의 대략적인 위치 정보와 몸통의 위치정보를 이용하여 단위 매쉬영상과 일치되는 영상을 찾은 후 결과 영상을 조합하고 8방향 연결성을 이용하여 확장하고 화소간의 채우기 과정을 거쳐 최종적인 간영상을 추출하였다. 추출된 간 영상에서 간 영역의 특징적인 명암값과 다양한 구조단위를 가지고 Morpological Filtering을 수행 한 후 나타난 결과들을 조합하여 만들어진 영상에서 각 슬라이스 별로 크기순으로 큰 부분들을 남겨두어 굵은 혈관만을 추출하였다. 추출된 영상들을 3D로 구성 시 자연스럽게 보여지도록 인터폴레이션을 수행한 후 3D Reconstruction 을 수행하여 3D 형태의 간 혈관을 보고 중간 정맥을 파악하여 간 실질의 절단 위치를 예측하게 된다. 절단되어진 간 실질의 크기를 확인하고 계산에 의하여 수술 성공 가능성을 파악할 수 있다.

뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식 (Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.961-968
    • /
    • 2019
  • 본 연구는 CT를 이용한 뇌혈관 추출 검사에서 이중에너지 기법을 활용하여 각 에너지 준위별 뇌혈관 조영술의 유용성을 평가하였다. 방법은 CT 뇌혈관 조영술을 시행한 환자 15명의 DE 영상과 SE 영상을 대상으로 하였다. 영상의 분석은 MCA, 뇌실직 조직, Background에 ROI를 설정하여 평균값, 표준편차 및 SNR, CNR 값을 구하고, SE영상과 비슷하게 구현되는 에너지 영역을 알아보았다. Likert 5점 척도 육안평가를 병행한 결과 DE 40 keV와 SE 120 kVp에서 가장 선명한 MCA 영상을 확인 하였다(p>0.05). SE영상의 SNR 값은 DE영상의 40 keV에너지 준위값과 비슷하게 측정되었고, 40 keV와 50 keV의 저에너지 준위의 영상이 SNR이 높게 측정되어 고에너지 준위의 영상에 비해 대조도가 높아 뇌혈관질환을 유용하게 관찰할 수 있을 것으로 사료된다.