• Title/Summary/Keyword: MCNP코드

Search Result 83, Processing Time 0.033 seconds

Calculations of Radiation Measurement-Related Correction Factors (방사선 측정관련 보정인자 계산)

  • Shin, Hee-Sung;Ro, Seung-Gy;Kim, Ho-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • The self-attenuation factor for an $^{198}Au$ sample and the 0.412 MeV gamma-ray penetration ratio in the circular Al-cover of the radiation detector have been determined using an analytical solution and MCNP code. The results show that the self-attenuation factors obtained from the analytical solution coincide with those of MCNP code for all but the Au sample with the relatively larger radius. Then the maximum difference between the two methods appears to be 9 % in the Au sample of 1.5 mm radius. It also is revealed that the analytical solutions of the 0.412 MeV gamma-ray penetration ratio in the Al-cover of 7.62 cm radius are consistent with those of the MCNP code within the standard deviation.

MCNP-4A와 CASMO-3를 이용한 CE 16$\times$16 핵연료집합체 임계도 및 봉출력 분포 해석

  • 김교윤;김강석;박찬오
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.79-84
    • /
    • 1995
  • 핵연료집합체 연소도 계산용 전산코드인 CASMO-3를 도입하여 한국고유핵설계체계를 개발하기 위해서는 CE형 핵연료집합체의 핵적특성을 파악하는 것은 필수적이다. 따라서, CASMO-3와 몬테칼로 전산코드인 MCNP-4A를 이용하여 CE형 16$\times$16 핵연료집합체에 대한 $K_{inf}$ 및 봉출력 분포를 비교 분석하였다. $K_{inf}$ 의 경우는 CASMO-3에 의한 계산 결과가 0.5% 이내에서 MCNP-4A의 계산 결과와 일치하였으며, 봉출력분포의 경우도 제어봉 주변이나 Gd$_2$O$_3$ 독봉을 제외하고는 CASMO-3에 의한 계산 결과가 MCNP-4A의 계산 결과와 거의 일치하는 것으로 나타났다.

  • PDF

MCNP코드를 이용한 영광3호기 방사선관리구역에서의 중성자 스펙트럼 계산

  • 한치영;김종경;조찬희;신상운;송명재
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.115-120
    • /
    • 1997
  • 영광3호기 방사선관리구역에 대한 중성자선량률을 정확히 평가하기 위하여 MCNP4A 전산코드를 이용, 방사선관리구역에서의 중성자 스펙트럼 계산을 수행하였다. 영광3호기에 대한 보다 정확하고 정밀한 3차원 몬테칼로 모델을 구축하기 위하여 핵연료집합체 구성요소 및 원자로심을 둘러싸고 있는 baffle, barrel,압력용기 등을 정확하게 묘사하였으며, 특히 방사선관리구역 주위의 구조물에 대해서도 3자원 MCNP 모델을 구축함으로써 원자로심부터 방사선관리구역까지 완전한 몬테칼로 모사(full-scope Monte Carlo simulation)를 이용한 계산을 수행하였다. 계산결과는 에너지 구간에 따른 중성자속 스펙트럼으로 나타내었으며 이 결과를 바탕으로 중성자속에 대한 선량률 환산인자를 고려하여 중성자선량률을 계산할 수 있다.

  • PDF

A Study on the Comparison of HPGe Detector Response Data for Low Energy Photons Using MCNP, EGS, and ITS Codes (MCNP, EGS, ITS코드를 이용한 고순도 게르마늄 검출기의 저에너지 광자에 대한 반응 비교연구)

  • Kim, Soon-Young;Kim, Jong-Kyung;Kim, Jong-Oh;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.125-129
    • /
    • 1996
  • The energy response of HPGe detector for low energy Photons was determined by using three Monte Carlo codes. MCNP4A. EGS4, and CYLTRAN in ITS3. In this study. bare HPGe detector$(100 mm^2{\times}10mm)$ was used and a pencil beam was incident perpendicularly on the center of the detector surface. The photopeak efficiency, $K_{\alpha}$ and $K_{\beta}$ escape fractions were calculated as a function of incident X-ray energies ranging from 12 to 60 keV in 2-keV increments. Since the Compton. elastic. ana penetration fraction were negligible in this energy range. they were ignored in the calculation. Although MCNP. EGS, and CYLTRAN codes calculated slightly different energy response of HPGe detector for low energy Photons, it appears that the three Monte Carlo codes can Predict the low energy Photon scattering Processes accurately. The MCNP results, which are generally known as to be less accurate at low energy ranges than the EGS and ITS results. are comparable to the results of EGS and ITS and are applicable to the calculation of the low energy response data of a detector.

  • PDF

Application of the HELIOS-MASTER Code System on the Criticality Analysis for the SMART-P Spent Fuel Storage (SMART연구로 사용후 연료 저장조의 임계해석에 HELIOS-MASTER계산체계의 적용)

  • Kim, Ha-Yong;Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.61-67
    • /
    • 2005
  • The criticality analysis method using HELIOS-MASTER code system, which is the nuclear core analysis code system, was developed for the spent fuel storage of SMART-P reactor. We generated the macroscopic cross section of the geometric model with HELIOS and estimated the criticality of the 3-dimensional model with MASTER for SMART-P spent fuel storage. The validity of criticality analysis method for SMART-P spent fuel storage with the HELIOS-MASTER code system by 3-D MCNP calculation was also verified. The result of the criticality analysis with the HELIOS-MASTER code system is more conservative than that with the MCNP and the accuracy of this result is within the range of an allowable error. Because HELIOS-MASTER can perform the 3-D depletion calculation lot a spent fuel storage, it will be useful to perform the criticality analysis including a burnup credit in future.

몬테칼로모사를 이용한 고리 1 호기 감시?슐에서의 핵반응단면적 및 고속중성자플루언스 계산

  • 김종오;김종경
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.45-52
    • /
    • 1996
  • 고리 1 호기 원자로 감시?슐에서의 고속중성자 플루언스를 계산하기 위하여 MCNP코드로 3차원 모델링을 하였다. 중성자선원은 MCNP에 의해 계산된 핵연료봉출력분포를 사용하였고 원자로심부터 원자로 압력용기 밖까지 1 MeV이상의 중성자를 수송시켰다. 감시?슐은 실제의 같은 크기로 모델링하였고 감시?슐안의 시편은 원자로 압력용기와 같은 재질의 직육면체로 가정하였다. 그리고 MCNP에 의해 감시시편내의 방사화 시료의 핵반응단면적을 계산하였다. 또한 MCNP에 의해 이론적으로 계산된 감시?슐에서 중성자 플루언스와 기존의 감시시험에서 측정된 포화방사능으로 부터 계산된 실험적 감시?슐 중성자 플루언스를 비교하였다. 이론적 ?슐플루언스와 실험적 ?슐플루언스의 비는 대체로 1.0에서 크게 벗어나지 않았으나 감시시험과 시편에 따라 크게 벗어나는 경우도 있었다. MCNP에 의한 유효반응단면적의 계산방법이 기존의 방법보다 모델링 및 계산의 불확실성을 최소화 할 수 있으므로 이번 연구에서 고려하지 못한 원자로심의 연소도를 고려한다면 매우 신뢰성이 높은 결과를 얻을 수 있다.

  • PDF

Evaluation on the Radiological Shielding Design of a Hot Cell Facility (핫셀시설의 방사선 안전성 평가)

  • 조일제;국동학;구정회;정원명;유길성;이은표;박성원
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • The hot cell facility for research activities related to the lithium reduction of spent fuel, which is designed to permit safe handling of source materials with radioactivity levels up to 1,385 TBq, is planned to be built. To meet this goal, the facility is designed to keep gamma and neutron radiation lower than the recommended dose-rate in normally occupied areas. The calculations peformed with QAD-CGGP and MCNP-4C are used to evaluate the proposed engineering design concepts that would provide acceptable dose-rates during a normal operation in hot cell facility. The maximum effective gamma dose-rates on the surfaces of the facility at operation area and at service area calculated by QAD-CGGP are estimated to be $2.10{\times}10^{-3}, 2.97{\times}10^{-3} and 1.01{\times}10{-1}$ mSv/h, respectively. And those calculated by MCNP-4C are $1.60{\times}10^{-3}, 2.99{\times}10^{-3} and 7.88{\times}10^{-2}$ mSv/h, respectively, The dose-rates contributed by neutrons are one order of magnitude less than that of gamma sources. Therefore, it is confirmed that the radiological design for hot cell facility satisfies the Korean criterion of 0.01 mSv/h for the operation area and 0.15 mSv/h for the service (maintenance) area.

  • PDF