• Title/Summary/Keyword: MCM2

Search Result 219, Processing Time 0.027 seconds

Comparison of automatic and manual chamber methods for measuring soil respiration in a temperate broad-leaved forest

  • Lee, Jae-Seok
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.272-277
    • /
    • 2018
  • Background: Studying the ecosystem carbon cycle requires analysis of interrelationships between soil respiration (Rs) and the environment to evaluate the balance. Various methods and instruments have been used to measure Rs. The closed chamber method, which is currently widely used to determine Rs, creates a closed space on the soil surface, measures $CO_2$ concentration in the inner space, and calculates Rs from the increase. Accordingly, the method is divided into automatic or manual chamber methods (ACM and MCM, respectively). However, errors of these methods and differences in instruments are unclear. Therefore, we evaluated the characteristics and difference of Rs values calculated using both methods with actual data. Results: Both methods determined seasonal variation patterns of Rs, reflecting overall changes in soil temperature (Ts). ACM clearly showed detailed changes in Rs, but MCM did not, because such small changes are unknown as Rs values are collected monthly. Additionally, Rs measured using MCM was higher than that using ACM and differed depending on measured plots, but showed similar tendencies with all measurement times and plots. Contrastingly, MCM Rs values in August for plot 4 were very high compared with ACM Rs values because of soil disturbances that easily occur during MCM measurements. Comparing Rs values calculated using monthly means with those calculated using MCM, the ACM calculated values for monthly averages were higher or lower than those of similar measurement times using the MCM. The difference between the ACM and MCM was attributed to greater or lesser differences. These Rs values estimated the carbon released into the atmosphere during measurement periods to be approximately 57% higher with MCM than with ACM, at 5.1 and $7.9C\;ton\;ha^{-1}$, respectively. Conclusion: ACM calculated average values based on various Rs values as high and low for measurement periods, but the MCM produced only specific values for measurement times as representative values. Therefore, MCM may exhibit large errors in selection differences during Rs measurements. Therefore, to reduce this error using MCM, the time and frequency of measurement should be set to obtain Rs under various environmental conditions. Contrastingly, the MCM measurement is obtained during $CO_2$ evaluation in the soil owing to soil disturbance caused by measuring equipment, so close attention should be paid to measurements. This is because the measurement process is disturbed by high $CO_2$ soil concentration, and even small soil disturbances could release high levels into the chamber, causing large Rs errors. Therefore, the MCM should be adequately mastered before using the device to measure Rs.

Interconnect Characterization for High Speed MCM Application (High Speed MCM 적용을 위한 Interconnect Characterization 에 대한 연구)

  • 이경환
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.4 no.2
    • /
    • pp.25-32
    • /
    • 1997
  • 대용량, 고속 정보처리가 요구되는 System의 모듈은 Data 처리의 고속성 및 회로의 고집적이 가능한 MCM의 형태로 구현되어 ATM, GPS 및 PCS 등의 분야에 광범위하게 응 용되고 있다. 위와 같은 High Speed 응용분야에서의 System 성능은 Interconnect Line의 전달지연, 임피던스 부정합에 의한 신호 반사 손실. 신호선 간의 Crosstalk, Ground Bounce 등의 현상에 대한 최적화 여부에 결정적인 영향을 받는다. 그러나 Interconnect의 특성상 정 형이 존재하지 않으므로 추상적인 Library를 구축하는 형식으로 접근할 수밖에 없으며 이를 위하여 여러기본 구조를 정의한후 각 Dimension을 변수로 두고 해석 결과를 합성하여 Database화하는 접근방식이다. 본 논문에서는 MCM-D 공정을 이용하여 Interconnect Line 특성을 분석하고 Database화 하기 위한 Test Pattern을 구현하고 Time Domain reflectometry(TDR)을 이용하여 그특성들을 측정 분석하였다. Test pattern 제작은 MCM-D 공정으로 최소선폭 27$\mu$m, Via Hole 75$\mu$m으로 형성하였고 2 Layer Signal과 GND로 총 3Layer를 구현하였다. 특성분석을 위해 TDR장비와 모데링 및 Simulation S/W인 IPA 510 을 사용하였다. 이를 통해 MCM-D를 이용한 공정에서 Interconcet Line의 고주파 특성을 측정하고 정량화하여 LIbrary를 제작할수 있었다.

Optimization of Synthetic Parameters for Mesoporous Molecular Sieve MCM-41 Using Surfactant CTAC1

  • 박동호;Cheng, Chi Feng;Jacek Klinowski
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.4
    • /
    • pp.379-384
    • /
    • 1997
  • High quality MCM-41 is prepared from a gel of molar composition SiO2:0.20 CTACl:0.18 TMAOH:25 H2O aged at 20 ℃ for 24 hours before crystallization lasting for 48 hours. The (110) and (200) peaks of XRD pattern of high quality MCM-41 are unusually well resolved and the FWHM (full-width-at-half-maximum) of the (100) peak is 0.13° for as-prepared MCM-41 and 0.21° for calcined one, which indicate well-developed crystals. The properties of the crystal depend on the source and concentration of the reactants and the gel aging time. There is no induction period in the course of the synthesis, which is conveniently monitored by pH measurement. Gel aging, during which a spatial distribution of silicate polyanions and micellar cations is established, is essential for preparing high quality MCM-41. Surfactants with the same cationic organic group but different counteranions change the crystallization behavior. Highly basic gel (pH=12.6) favours the lamellar product; the quality of MCM-41 is lower as insufficient TMAOH is available to dissolve the silica.

The Effects of C2F6 Plasma Cleaning on Via Formation in MCM-D Substrate using photosensitive BCB (감광성 BCB를 사용한 MCM-D 기판에서 C2F6 플라즈마 clcaning 이 비야형성에 미 치는 영향)

  • 이영민
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.2
    • /
    • pp.7-12
    • /
    • 1998
  • 감광성 BCB를 사용한 MCM-D기판에 신뢰성있는 비아형성을 위하여 BCB의 공정 특성과 C2F6를 사용한 플라즈마 cleaning 영향을 분석하였다. 절연막, 금속배선재료로 각각 감광성 BCB, Cu를 사용하여 MCM-D 기판을 제작 분석한 결과 BCB는 soft bake 후 초기 두께의 50%정도 두께 손실이 있었으며 해상도는 15um이었다. BCB층에 비아 형성후 C2F6 가스로 플라즈마 cleaning 하고 AES로 비아표면을 분석한 결과 유기물 C는 검출되지 않은 반면 플라즈마 cleaning을 하지 않은 비아를 분석한 결과 유기물 성분의 C가 많이 검출되었 고 Ar 스퍼터에 의해서도 완전히 제거되지 않았다. 따라서 감광성 BCB를 절연막으로 사용 한 MCM-D 기판 제작공정에서 비아 형성후 C2F6를 이용한 플라즈마 cleaning의 필요성을 확인하였다.

The Study on Testability of high Speed and High Integrated Multichip Module (고속, 고집적 Multichip Module의 시험성 확보에 관한 고찰)

  • 김승곤
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.5 no.2
    • /
    • pp.21-26
    • /
    • 1998
  • 대용량, 고속데이터 처리가 요구되는 System 개발은 이들의 복잡하고 고기능의 회 로 구현이 가능하냐에 달려 있고 또한 이들고기능 요구를 가장 잘 만족할수 있는 패키지는 MCM 이라 할 수있다. 시스템의 고속화, 소형화는 회로의 복잡성을 요구하는 있는 이를 패 키지로 구현하는 MCM은 시험성 확보에 심각한 문제점으로 나타나고 있다. 본 논문에서는 고밀도 구조의 MCM 기판에 대한 Interconnetion Line 시험검증을 위한 Flying Prober의 적 용 및 모듈 패키징 공정에 대한 조립성 검증을 위한 BST에 대해 설명한다. 연구에 사용된 MCM 모듈은 MCM-D 공정으로 제작되었으며 31um 신호선폭, 50um Via Hole Dia. 5신호 선층 5절연층 및 455 Net의 기판으로절연층은 Dow chemical의 BCB-4024/4026을 적용하였 다. 조립은 3 ASIC, 24소자 실장 및 2000 Wire Bonding으로 이루어지며 패키지는 방열특성 을 고려한 BGA(491 I /O,50mil pitch)를 개발하여 사용하였다. MCM 기판의미세패턴으로 구성된 Interconnection Line에 대해 Fine Ptich Probing이 가능한 Flying Prober를 사용하 여 평가하였으며 BST를 이용하여 실장소자의 KGD평가 및 능동, 수동소자가 실장된 MCM Package의 조립시험성을 확보할수 있었다.

Iron(III) removal from aqueous solution using MCM-41 ceramic composite membrane

  • Basumatary, Ashim Kumar;Kumar, R. Vinoth;Pakshirajan, Kannan;Pugazhenthi, G.
    • Membrane and Water Treatment
    • /
    • v.7 no.6
    • /
    • pp.495-505
    • /
    • 2016
  • Mesoporous MCM-41 was deposited on an inexpensive disk shaped ceramic support through hydrothermal technique for ultrafiltration of $Fe^{3+}$ from aqueous solution. The ceramic support was fabricated using uni-axial compaction technique followed by sintering at $950^{\circ}C$. The characteristics of MCM-41 powder as well as the composite membrane were examined by X-ray diffraction (XRD), thermogravimetric analysis (TGA), field emission scanning electron microscope (FESEM), porosity and pure water permeation test. The XRD result revealed the good crystallinity and well-resolved hexagonally arranged pore geometry of MCM-41. TGA profile of synthesized MCM-41 zeolite displayed the three different stepwise mechanisms for the removal of organic template. The formation of MCM-41 on the porous support was verified by FESEM analysis. The characterization results clearly indicated that the accumulation of MCM-41 by repeated coating on the ceramic disk directs to reduce the porosity and pore size from 47% to 23% and 1.0 to $0.173{\mu}m$, respectively. Moreover, the potential of the fabricated MCM-41 membrane was investigated by ultrafiltration of $Fe^{3+}$ from aqueous stream at various influencing parameters such as applied pressure, initial feed concentration and pH of solution. The maximum rejection 85% was obtained at applied pressure of 276 kPa and the initial feed concentration of 250 ppm at pH 2.

Preparation and Characterization of Cu/MCM-41 Mesoporous Catalysts for NO Removal (Cu/MCM-41 메조포러스 촉매 제조 및 NO 제거 특성)

  • Park, Soo-Jin;Cho, Mi-Hwa;Kim, Seok;Kwon, Soo-Han
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.737-741
    • /
    • 2005
  • In this study, the effect of copper content on the NO removal efficiency by Cu/MCM-41 has been investigated. MCM-41 was prepared by hydrothermal synthesis using a gel mixture of colloidal silica solution and cetyltrimethylammonium. Cu/MCM-41 was manufactured with copper content (5, 10, 20, and 40%) in Cu(II) acetylacetonate. The surface properties of MCM-41 were investigated by using pH, XRD, and FT-IR analyses. $N_2/77K$ adsorption isotherm characteristics, including the specific surface area and micropore volume were studied by BET's equation and Boer's t-plot methods. NO removal efficiency was confirmed by gas chromatography technique. From the experimental results, the MCM-41 was analyzed to have the surface functional groups of Si-OH and Si-O-Si and the characteristic diffraction lines (100), (110), (200), and (210) corresponding to a hexagonal arrangement structure. The copper content supported on MCM-41 appeared to increase the NO removal efficiency in spite of decreasing the specific surface areas or micropore volumes. Consequently, it was found that the copper content in Cu/MCM-41 played an important role in improving the NO removal efficiency, which was mainly attributed to the catalytic reactions.

Knoevenagel Condensation Reaction Using Amine-functionalized MCM-41 Base Catalysts (아민고정화 MCM-41 염기촉매를 이용한 Knoevenagel 축합반응)

  • Choi, Jung-Sik;Ahn, Wha-Seung
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • A series of amine functionalized MCM-41 catalysts were prepared by aminopropyltrimethoxysilane grafting and their catalytic performance in Knoevenagel reaction of selected substrates was investigated. Water resistant and catalytically active amine grafted MCM-41 was prepared by post-synthetic silylation using methyltrimethoxysilane ; hydrogen bonding of the water molecules formed during the condensation reaction to the active N group was suppressed, which led to high TON of the reaction. Amine functionalized MCM-41 prepared by coating method produced high conversion, but the TON of the catalyst was much lower than that of the amine grafted MCM-41; pore volume of the functionalized MCM-41 decreased substantially and large portion of the immobilized amine is believed to be hydrogen bonded to each other, which can result in decrease in the basicity of the N group. A secondary amine group was prepared by room temperature condensation between aminopropylsilane and chloropropylsilane, and the MCM-41 grafted with the secondary amine group demonstrated the highest catalytic activity among the catalysts prepared.

Impregnation of Ibuprofen on MCM-41 using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 MCM-41에의 Ibuprofen 함침)

  • Kim, Hong-Lyong;Kim, Jung-Teag;Chun, Jae Kee;Lee, Seok Hee;Hong, Seong-Soo;Ju, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.248-253
    • /
    • 2006
  • In order to develope an efficient drug delivery system, experimental researches on the supercritical impregnation of ibuprofen onto mesoporous silica, MCM-41,and its drug release characteristics were performed. Supercritical carbon dioxide was adapted as an alternative solvent as it is harmless and able to avoid defects of organic solvents in drug manufacturing processes. The procedure was composed of three steps, that is, as hydrothermal synthesis of MCM-41, supercritical impregnation of ibuprofen onto MCM-41 and release of impregnated ibuprofen. Supercritical impregnation reached equilibrium within 2 h for all cases of this research and the amount of equilibrium impregnation increased with solubility of ibuprofen in supercritical carbon dioxide. Release profiles of impregnated ibuprofen showed a similar behavior for all MCM-41 with different impregnated ibuprofen.

Monte Carlo Simulation on Adsorption Properties of Benzene, Toluene, and p-Xylene in MCM-41

  • Moon, Sung-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.8
    • /
    • pp.2553-2559
    • /
    • 2012
  • The adsorption properties of benzene, toluene, p-xylene in MCM-41 with heterogeneous and cylindrical pore were studied using grand canonical ensemble Monte Carlo simulation. The simulated isotherms were compared with experimental ones, and the different adsorption behaviors in MCM-41 with pore diameters of 2.2 and 3.2 nm were investigated. The simulated adsorption amounts above the capillary-condensation pressure agreed with the experimental ones. The simulation results showed that most molecular planes were nearly parallel to the pore axis. This orientation was not affected by the molecular position in the pore. The molecular planes were nearly parallel to the pore surface for the adsorbate molecules close to the pore wall, and the molecules in the MCM-41 with the pore diameter of 3.2 nm were ordered along the pore axis.