• Title/Summary/Keyword: MCG

Search Result 160, Processing Time 0.021 seconds

Anti-inflammatory Effects of MeOH Extract of Corylopsis gotoana Uyeki (히어리의 항염증 효능)

  • Lee, Ha Na;Cha, Dong Seok;Jeon, Hoon
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.2
    • /
    • pp.165-171
    • /
    • 2016
  • Corylopsis gotoana (Hamamelidaceae) has been used as a traditional medicine for the treatment various diseases including cold, edema and vomiting. However, previous studies regarding component analysis and pharmacological actions of C. gotoana are extremely limited until now. In this study, we investigated anti-inflammatory activities of the methanolic extract of the twigs of Corylopsis gotoana (MCG) both in vitro and in vivo. MCG effectively inhibited excessive NO production in IFN-${\gamma}$ and LPS-stimulated mouse peritoneal macrophages without notable cytotoxicity. In addition, we also found that MCG could attenuate the expression of inflammatory mediators such as inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2). We further tested in vivo anti-inflammatory activity of MCG using paw edema mouse model. Herein, MCG demonstrated significant suppression on the paw edema induced by both of trypsin and carrageenan. These results indicated that MCG has potent anti-inflammatory potential and may be useful for prevention and treatments of inflammatory diseases.

The Effect of Lidocaine Dose and Pretreated Diazepam on Cardiovascular System and Plasma Concentration of Lidocaine in Dogs Ansthetized with Halothane-Nitrous Oxide (Diazepam 전투여와 Lidocaine 투여용량이 혈중농도 및 심혈역학적 변화에 미치는 영향)

  • Lee, Kyeong-Sook;Kim, Sae-Yeon;Park, Dae-Pal;Kim, Jin-Mo;Chung, Chung-Gil
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.451-474
    • /
    • 1993
  • Lidocaline if frequently administered as a component of an anesthetic : for local or regional nerve blocks, to mitigate the autonomic response to laryngoscopy and tracheal intubation, to suppress the cough reflex, and for antiarrythmic therapy. Diazepam dectease the potential central nervous system (CNS) toxicity of local anesthetic agents but may modify the sitmulant action of lidocaine in addition to their own cardiovascular depressant. The potential cardiovascular toxicity of local anesthetics may be enhanced by the concomitant administration of diazepam. This study was designed to investigate the effects of lidocaine dose and pretreated diazepam to cardiovascular system and plasma concentration of lidocaine. Lidocaine in 100 mcg/kg/min, 200 mcg/kg/min, and 300 mcg/kg/min was given by sequential infusion to dogs anesthetized with halothane-nitrous oxide (Group I). And in group II, after diazepam pretreatment, lidocaine was infused by same way when lidocaine was administered in 100 mcg/kg/min, the low plasma levels ($3.97{\pm}0.22-4.48{\pm}0.36$ mcg/ml) caused a little reduction in cardiovascular hemodynamics. As administered in 200 mcg/kg/min, 300 mcg/kg/min, the higher plasma levels ($7.50{\pm}0.66-11.83{\pm}0.59$ mcg/ml) reduced mean arterial pressure (MAP), cardiac index (CI), stroke index (SI), left ventricular stroke work index (LVSWI), and right ventricular stroke work index (PVSWI) and increased pulmonary artery wedge pressure (PAWP), central venous pressure (CVP), systemic vascular resistance index (SVRI), but was associated with little changes of heart rate (HR), mean pulmonary artery pressure (MPAP), and pulmonary vascular resistance index (PVRI). When lidocaine with pretreated diazepam was administered in 100 mcg/kg/min, the low plasma level, the lower level than when only lidocaine administered, reduced MAP, but was not changed other cardiovascular hemodynamics. While lidocaine was infused in 200 mcg/kg/min, 300 mcg/kg/min in dogs pretreated diazepam, the higher plasma level ($7.64{\pm}0.79-13.79{\pm}0.82$ mcg/ml) was maintained and was associated with reduced CI, SI, LVSWI and incresed PAWP, CVP, SVRI but was a little changes of HR, MPAP, PVRI. After $CaCl_2$ administeration, CI, SI, SVRI, LVSWI was recovered but PAWP, CVP was rather increased than recovered. The foregoing results demonstrate that pretreated diazepam imposes no additional burden on cardiovascular system when a infusion of large dose of lidocaine is given to dogs anesthetized with halothanenitrous oxide. But caution may be advised if the addition of lidocaine is indicated in subjects who have impared autonomic nervous system and who are in hypercarbic, hypoxic, or acidotic states.

  • PDF

Comparison of Magnetocardiogram Parameters Between a Ischemic Heart Disease Group and Control Group (정상군 및 허혈성 심질환 환자군에서의 심자도 파라미터 비교)

  • Park, Jong-Duk;Huh, Young;Jin, Seung-oh;Jeon, Sung-chae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.11
    • /
    • pp.680-688
    • /
    • 2005
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. We have analyzed the possibility and characteristics of MCG parameters for diagnosis of ischemic heart disease. A technique for automatic analysis of MCG signals in time domain was developed. The methods for detecting the position, the interval, the amplitude ratio, and the direction of single current dipole were examined in the MCG wave. The position and interval parameters were obtained by calculating the gradients of a envelope curve which could be formed by the difference between the maximum and minimum envelope of multi-channel MCG signals. We show some differences of the frequency contour map between the normal MCG and the abnormal (ischemic heart disease) MCG. The direction of single current dipole can be defined by rotating the magnetic field according to Biot-Savart's law at each point of MCG signals. In this study, we have examined the direction of single current dipole from searching for the centroids of positive and negative magnetic fields. The amplitude ratio parameters for measuring 57 deviation consisted of A$_{T}$/A$_{R}$ and other ratios. and We developed a new analysis method, which is based on the frequency contour map of electromagnetic field. Using theses parameters, we founded significant differences between normal subjects and ischemic patients in some parameters.

Application of 40-channel SQUID Gradiometer System for the Comparison of Magnetocardiograms from Healthy Subjects and Patients with WPW syndrome and DCM (40 채널 SQUID 미분계 시스템을 이용한 정상인과 WPW 증후군 및 확장성 심근증 환자의 심자도 비교)

  • 정용석;권혁찬;김기웅;이용호;강찬석;김진목;박용기;김기영;박기락
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • The aim of this study is to confirm clinical usefulness of magnetocardiogram (MCG) by analyzing MCG data of health subjects and patients with Wolff-Parkinson-White (WPW) syndrome and dilated cardiomyopathy (DCM). Measurement of MCG signals was done with a home-made 40-channel SQUID system. MCG signals of 30 healthy subjects were measured as the reference of MCG signals. Among the DCM patients, 7 patients showed abnormal the direction of T wave vector. For a WPW syndrome patient, we measured the MCG signals before and after the surgery. and compared the difference. From the measured magnetic field distribution, current vector map was obtained to show the myocardium current activity. By comparing the MCG signals and current maps, we showed the differences in the analysis results between the healthy subjects and patients with heart diseases.

  • PDF

Mountain-cultivated ginseng protects against cognitive impairments in aged GPx-1 knockout mice via activation of Nrf2/ChAT/ERK signaling pathway

  • Bao Trong Nguyen;Eun-Joo Shin;Ji Hoon Jeong;Naveen Sharma;Ngoc Kim Cuong Tran;Yen Nhi Doan Nguyen;Dae-Joong Kim;Myung Bok Wie;Yi Lee;Jae Kyung Byun;Sung Kwon Ko;Seung-Yeol Nah;Hyoung-Chun Kim
    • Journal of Ginseng Research
    • /
    • v.47 no.4
    • /
    • pp.561-571
    • /
    • 2023
  • Background: Escalating evidence shows that ginseng possesses an antiaging potential with cognitive enhancing activity. As mountain cultivated ginseng (MCG) is cultivated without agricultural chemicals, MCG has emerged as a popular herb medicine. However, little is known about the MCG-mediated pharmacological mechanism on brain aging. Methods: As we demonstrated that glutathione peroxidase (GPx) is important for enhancing memory function in the animal model of aging, we investigated the role of MCG as a GPx inducer using GPx-1 (a major type of GPx) knockout (KO) mice. We assessed whether MCG modulates redox and cholinergic parameters, and memory function in aged GPx-1 knockout KOmice. Results: Redox burden of aged GPx-1 KO mice was more evident than that of aged wild-type (WT) mice. Alteration of Nrf2 DNA binding activity appeared to be more evident than that of NFκB DNA binding activity in aged GPx-1 KO mice. Alteration in choline acetyltransferase (ChAT) activity was more evident than that in acetylcholine esterase activity. MCG significantly attenuated reductions in Nrf2 system and ChAT level. MCG significantly enhanced the co-localization of Nrf2-immunoreactivity and ChAT-immunoreactivity in the same cell population. Nrf2 inhibitor brusatol significantly counteracted MCG-mediated up-regulation in ChAT level and ChAT inhibition (by k252a) significantly reduced ERK phosphorylation by MCG, suggesting that MCG might require signal cascade of Nrf2/ChAT/ERK to enhance cognition. Conclusion: GPx-1 depletion might be a prerequisite for cognitive impairment in aged animals. MCG-mediated cognition enhancement might be associated with the activations of Nrf2, ChAT, and ERK signaling cascade.

Review of Magnetocardiography Technology based on SQUIDs (SQUID를 이용한 심자도 기술의 개발동향)

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Kim, K.;Yu, K.K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

Effect of the Sensor Location on Magnetocardiography (심자도 센서의 위치 효과에 대한 연구)

  • Lim, Hyun-Kyoon;Kim, Ki-Woong;Kwon, Hyuk-Chan;Lee, Yong-Ho
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Magnetocardiography (MCG) is a non-contact, non-invasive, and harmless diagnostic tool to detect the abnormal electrical conductivities of the heart caused by the various coronary artery disease or cardiac muscular disease. The purpose of this study is to identify whether MCG signals and MCG parameter values vary depending on the location of sensor assembly. It will be an important reference for the standard measurement. Four healthy male subjects (33.3$\pm$6.3 years) participated in this study. Basal recording was made at 20 mm apart from the chest surface. All subjects were requested to take a regular breathe while MCG was taken. The gap between the chest surface and the bottom of the sensor assembly was 20, 40, 60, and 80 mm. Recording was made using 64 channel MCG system (Axial type, first order gradiometer) developed by Korea Research Institute of Standards and Science (KRISS). After resting for two minutes in a supine position on the bed in magnetically shielded room, MCG were recorded for 30 s. As the sensor location is getting away from the chest surface signal, the amplitude of R and T wave peak decreases to 70% (at 40 mm gap), 50% (at 60 mm), and 37% (at 80 mm) of the reference strength measured (y = $1.3903e^{-0.0169x}$, $R^2$ = 0.99; where y=amplitude remained after reduction, x=distance between chest surface and sensor location). The regression equations may be used as a good reference to calculate how much strength will be decreased by the distance. In MCG parameters, most values of parameters were decreased as the gap was increased. As an example, the current moment at T-wave peak reduced to 52% (at 40 mm gap), 33% (at 60 mm), and 19% (at 80 mm). However, the difference caused by the gap could be reduced by considering the distance when the MCG parameters were calculated. The study results can be used as a useful reference to design the baseline and the sensor location.

  • PDF

Magnetic Noise Reduction in MCG Using Spatial Filters (공간 필터를 이용한 심자도 신호에서의 자기잡음 제거)

  • Lee, Hana;Kim, Ki-Wang;Lee, Soo-Yeol;Cho, Min-Hyung;Heo, Young
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.287-292
    • /
    • 2003
  • Even though MCG has many advantages over ECG, MCG signa)s are easily corrupted by external magnetic noises Since multi-channel MCG signals are recorded simultaneously at many spatial positions, it is effective to apply spatial fitters as well as the conventional temporal filters to remove external magnetic noises. The spatial filters can be designed by utilizing the fact that the noise signals caused by external noise sources are more spatially correlated than the original MCG signals. In this paper, we introduce a spatial filtering method for the noise reduction in MCG based on the principal component analysis. Healthy volunteer study results obtained with a 61-channel MCG system are presented.

Magnetocardiogram Measurement of Laboratory Rat (백서를 이용한 심자도 신호 측정)

  • Kim, I.S.;Ahn, San;Kwon, H.C.;Song, J.H.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.147-151
    • /
    • 2010
  • We have developed a high-$T_c$ SQUID magnetocardiogram (MCG) system for small laboratory animals. White noise of the measurement system was about 30 fT/$Hz^{1/2}$ when measured in a magnetically shielded room. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 30 pT. We could observe well defined P-, QRS-, and T-waves from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of the heart disease model by using a laboratory rat.

Development of magnetocardiograph system using YBCO SQUID magnetometers (YBCO SQUID 자력계를 이용한 자기심장검사장치 개발)

  • Kim, I.S.;Oh, S.H.;Lim, H.K.;Lee, Y.H.;Lee, S.G.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.158-163
    • /
    • 2007
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal junctions have been fabricated for magnetocardiograph (MCG) measurements. We could fabricate YBCO SQUID magnetometers having magnetic field noise of about $20fT/Hz^{1/2}$ at white noise region. We have developed an MCG system employing the high performance SQUID magnetometers. The lightweight MCG system, requiring liquid nitrogen as a coolant, consists of 6-channel SQUID sensors, an adjustable patient bed with sliding motion, and data analyses software. The MCG system could record quite clear MCG signals in a room with moderate magnetic shielding. In normal operation with multi-position MCG measurements, we could obtain clear 48-point mappings of magnetic field map and current source map with high enough signal qualities far clinical trials.

  • PDF