• 제목/요약/키워드: MCE Membrane Filter

검색결과 4건 처리시간 0.019초

PVC 여과지를 이용한 금속 분석방법에 대한 정확도와 정밀도 평가 (Evaluation of Accuracy and Precision of Analysis of Metals with Polyvinyl Chloride Membrane Filters)

  • 변성욱;최상준
    • 한국산업보건학회지
    • /
    • 제26권1호
    • /
    • pp.48-57
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the accuracy and precision of airborne metal analysis using polyvinyl chloride(PVC) membrane filter by pretreatment methods. Methods: A total of 75 spiked PVC samples for Cr, Fe and Mn ranged from 6 ug/sample to 40 ug/sample were used to evaluate recovery rates for three pretreatment methods: acid extraction, hot plate ashing and microwave digestion. For Mn, an additional 75 spiked mixed cellulose ester(MCE) membrane filters were analysed to compare the recovery rates of PVC samples. All samples were analysed with an inductively coupled plasma optical emission spectrometer(ICP-OES) and manganese samples were additionally analyzed by atomic absorption spectrometer(AAS). Results: The overall mean recovery rates of PVC samples for Cr, Fe and Mn were 90% or higher regardless of pretreatment methods, but there were statistically significant differences in recovery rates for Cr(p<0.05) and Mn(p<0.01) samples by pretreatment methods. The biases and the coefficient variations of PVC samples for three metals pretreated with three kinds of pretreatment methods ranged from 1.7% to 4.7% and from 1.6% to 6.5%, respectively. The manganese PVC samples pretreated by microwave digestion and analyzed with ICP-OES had the lowest bias at 1.9% and also showed lower bias than the bias for MCE samples, 2.7%. Conclusions: In order to accurately analyze the metals sampled with PVC membrane filters, microwave digestion and ICP-OES can be recommended.

PBF 방식 금속 3D프린터로 제작된 환경DNA 필터 케이스의 내부 형상이 포집 성능에 미치는 영향 (Effect of the Internal Shape of eDNA Filter Case made by the PBF method Metal 3D Printer on Water Sampling Performance)

  • 이승민;박세현;곽인실;김형호;곽태수
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.74-79
    • /
    • 2021
  • This study focuses on designing a filter case using a water pump for application in eDNA filtering systems. Filter cases, channel type and net type were designed based on the flow field and made using a 3D printer for metal. Flow analysis was conducted for each filter case, and the results were consistent with the pressure experiment results. Furthermore, the water sampling performance test showed that the channel-type filter case exhibited a high flow rate and low pressure through the filter. The eDNA extraction experiment showed that the channel type exhibited improved capture ability compared to the net type.

도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가 (Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation)

  • 이병규;이지태;신용철
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

N-13 암모니아 주사액 제조 시 멸균필터의 흡착율 차이에 관한 비교 평가 (Studies on sterile filters in the preparation of N-13 ammonia injection)

  • 오창범;김시활;차민정;신진;지용기;최성욱
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.64-68
    • /
    • 2019
  • 기존에 Millex GS 멸균 필터를 사용하여 방사성 의약품 N-13 암모니아 주사액 제조 시 많은 양의 방사성 의약품이 멸균 필터에 흡착되어 있었다. 이에 Satorious의 Minisart 멸균 필터를 사용하여 흡착률의 차이를 확인하고 합성 수율을 증가시키고자 하였다. 실험 대상은 Millex GS 필터와 Satorious Minisart 필터를 대상으로 하였으며 제조된 N-13 암모니아를 각각의 멸균 필터에 통과시킨 후 선량계를 이용하여 흡착률을 구하였다(n=10). 그리고 품질 관리 시험을 시행하여 본원 기준에 적합한지 확인하였다. 실험 결과 Millex GS와 Sartorious Minisart 필터에 각각 $71.0{\pm}17.6%$$19.1{\pm}3.2%$ 흡착되었다. 필터를 제거한 product vial에는 Millex GS와 Sartorious 각각 $29.0{\pm}17.6%$$80.9{\pm}3.2%$ 여과되었다. 여과된 암모니아 주사액의 양은 GS 필터보다 Minisart 필터를 사용할 때 약 2.8배 더 많이 획득할 수 있었다. 각 멸균 필터를 통과한 N-13 암모니아 주사액의 방사화학적 이물, 화학적 이물, 이 핵종, pH, 엔도톡신, 무균 시험 등 품질 관리 시험 결과 본원 기준에 적합하였다. Millex GS 필터의 얇은 막은 mixed cellulous easter(MCE)로써 acetic acid, sulfic acid, anhydride에 추가로 Nitrocellulose가 약 80%의 비중을 차지하고 있는 필터이다. 때문에 Nitrocellulose가 포함되지 않은 CA계열인 Sartorious Minisart 필터보다 여과할 수 있는 성능은 Millex GS가 우수하나, 품질시험의 평가상 Satorious Minisart 필터를 사용하여도 문제가 없을 것이다. 따라서 N-13 암모니아 주사액 제조 시, Satorious Minisart 필터를 사용함으로써 필터 흡착으로 인한 손실을 최소화하고, 비용도 절감 할 수 있으며, 보다 안정적으로 N-13 암모니아 주사액을 제조 할 수 있을 것으로 생각한다.