• Title/Summary/Keyword: M2M architecture

Search Result 1,827, Processing Time 0.027 seconds

M&S PlugIn-Based Architecture Framework Development (M&S PlugIn-Based Architecture Framework 개발)

  • Won, Garng-Yun;Choi, Sang-Yeong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.2
    • /
    • pp.53-59
    • /
    • 2009
  • Simulation Based Acquisition(SBA) which pursues to use M&S in manner of integrated collaboration is being applied in defense acquisition. To accomplish SBA efficiently, reusability, reconfiguration and scalability of M&S components are important factors. To avoid constraints caused by coupling of components, PBA is designed to add and configure components easily by enabling independent interface and interaction among the components and provides common development infrastructure also. And PBA framework is implemented to support the development of a simulator which uses the PBA. It is expected that deployment of PBA framework as common development infrastructure can raise efficiency of M&S works.

A Study on the Evaluation of Thermal Performance of Aluminium Alloy Window Frame considering 2D Steady-state Heat Transfer applied to Educadtional Facility (2차원 정상전열해석을 통한 교육시설의 알루미늄 창호 열성능 평가에 관한 연구)

  • Kang, Jung-Hun;Kwak, Young-Kuhn;Noh, Seung-Uk;Park, Dae-Ho;Lee, Ju-Ho;Hong, Wan-Pyo;Hwang, In-Kyu;Park, Tong-So
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.122-125
    • /
    • 2011
  • 본 연구에서는 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열성능 평가를 수행하였다. 교육시설의 주요 창호재료로 적용된 알루미늄은 열전도율이 $175 \;Kcal/m^2h^{\circ}C$ 정도로 플라스틱 소재와 비교하여 매우 불리하여 기존 시설에 설치된 알루미늄 창호는 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 합금 창호의 열성능 평가에 관한 연구를 수행하여 다음과 같은 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물의 에너지절약설계기준의 [별표 6] 중부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 [별표 7]의 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 해석한 결과 열관류율은 알루미늄 합금 창호는 $U=9.631 \;W/m^2K$, 복층유리 $U= 2.382 \;W/m^2K$로 여름철과 겨울철 동일한 해석결과치가 산출되었다. (2) 산출된 열관류율 해석결과를 건축물의 에너지절약설계기준 [별표 3] 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반복층창 성능기준인 $4.0 \;W/m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열량이 손실됨을 보여 주고 있다.

  • PDF

A New Multiplication Algorithm and VLSI Architecture Over $GF(2^m)$ Using Gaussian Normal Basis (가우시안 정규기저를 이용한 $GF(2^m)$상의 새로운 곱셈 알고리즘 및 VLSI 구조)

  • Kwon, Soon-Hak;Kim, Hie-Cheol;Hong, Chun-Pyo;Kim, Chang-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12C
    • /
    • pp.1297-1308
    • /
    • 2006
  • Multiplications in finite fields are one of the most important arithmetic operations for implementations of elliptic curve cryptographic systems. In this paper, we propose a new multiplication algorithm and VLSI architecture over $GF(2^m)$ using Gaussian normal basis. The proposed algorithm is designed by using a symmetric property of normal elements multiplication and transforming coefficients of normal elements. The proposed multiplication algorithm is applicable to all the five recommended fields $GF(2^m)$ for elliptic curve cryptosystems by NIST and IEEE 1363, where $m\in${163, 233, 283, 409, 571}. A new VLSI architecture based on the proposed multiplication algorithm is faster or requires less hardware resources compared with previously proposed normal basis multipliers over $GF(2^m)$. In addition, we gives an easy method finding a basic multiplication matrix of normal elements.

An Study on Demand Estimation for Lifetime Sports Facilities (생활체육시설의 수요에측에 관한 연구)

  • Min, Young-Gi
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.2
    • /
    • pp.30-38
    • /
    • 2003
  • The purpose of this study was to analyze the demand estimation erection of lifetime sports facilities for making an accurate estimate of its demand on the basis of the rate of the people participating in lifetime sports activities. Participation rate was determined on the basis of the fact-finding survey [by the Ministry of Culture and Tourism(2000)] as a basis research on facilities demand, and its demand was calculated by making an estimate of facilities demand. An estimate of facilities demand was made in the equation by participation population, facilities demand for each person, sports space area for each person, time of sports, cycle of sports, possible time to use of sports space. Facilities demand for each person by sports event is the following: $swimming;0.03m^2$, $basketball;0.045m^2$, martial arts(taekwondo, judo, korean fencing);0.003 $75m^2$, $aerobics;0.0289m^2,\;health;0.00326m^2,\;badminton;0.00323m^2,\;tennis;0.01429m^2,\;soccer;0.1112m^2,\;squash;0.01323m^2$.

  • PDF

(Design of New Architecture for Simultaneously Computing Multiplication and Squaring over $GF(2^m)$ based on Cellular Automata) ($GF(2^m)$상에서 셀룰러 오토마타를 이용한 곱셈/제곱 동시 연산기 설계)

  • Gu, Gyo-Min;Ha, Gyeong-Ju;Kim, Hyeon-Seong;Yu, Gi-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.3
    • /
    • pp.211-219
    • /
    • 2002
  • In this paper, a new architecture that can simultaneously process modular multiplication and squaring on GF(2$^{m}$ ) in m clock cycles by using the cellular automata is presented. This can be used efficiently for the design of the modular exponentiation on the finite field which is the basic computation in most public key crypto systems such as Diffie-Hellman key exchange, EIGamal, etc. Also, the cellular automata architecture is simple, regular, modular, cascadable and therefore, can be utilized efficiently for the implementation of VLSI.

A New Systolic Array for LSD-first Multiplication in $CF(2^m)$ ($CF(2^m)$상의 LSD 우선 곱셈을 위한 새로운 시스톨릭 어레이)

  • Kim, Chang-Hoon;Nam, In-Gil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4C
    • /
    • pp.342-349
    • /
    • 2008
  • This paper presents a new digit-serial systolic multiplier over $CF(2^m)$ for cryptographic applications. When input data come in continuously, the proposed array produces multiplication results at a rate of one every ${\lceil}m/D{\rceil}$ clock cycles, where D is the selected digit size. Since the inner structure of the proposed array is tree-type, critical path increases logarithmically proportional to D. Therefore, the computation delay of the proposed architecture is significantly less than previously proposed digit-serial systolic multipliers whose critical path increases proportional to D. Furthermore, since the new architecture has the features of regularity, modularity, and unidirectional data flow, it is well suited to VLSI implementations.

Estimation of Appropriate Infiltration Rate and the Effects of the Flowerbed Type Infiltration System (화단형 침투시설의 단위설계침투량 산정 및 효과분석)

  • Han, Young-Hae;Lee, Tae-Goo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.140-147
    • /
    • 2012
  • This study developed a flowerbed type infiltration system that could control the amount of runoff discharge under a certain level estimated its proper design infiltration rate, and analyzed the effects of its implementation. Analyzing the performance of infiltration system is the one of the essential processes that should be under review to predict its effects after implementation when a rainwater infiltration system is included in a district-based plan. To estimate the unit design infiltration rate of this system, the runoff decrease effect was analyzed by varying the unit infiltration rate of the system applied to the parking lot adjacent to the Korea Institute of Construction Technology laboratory building by using a water balance analysis program. After varying the unit design infiltration to $0.1{\sim}3m^3/m^2.day$ to analyze the variation in the rate of runoff, 80% of the runoff was infiltrated at $1.0m^3/m^2.day$, and the unit infiltration design rate at the time was 0.0416(m3/m2.hr). It was also found that the unit design infiltration rate obtained from a field infiltration test of the developed system was about $0.045m^3/hr$. Based on this study, it was possible that infiltration rate is estimated to consider the economic scale and environmental effect. It is significant to apply the spatial plan of rainwater infiltration system as green infrastructure.

Low Complexity GF(2$^{m}$ ) Multiplier based on AOP (회로 복잡도를 개선한 AOP 기반의 GF(2$^{m}$ ) 승산기)

  • 변기영;성현경;김흥수
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2633-2636
    • /
    • 2003
  • This study focuses on the new hardware design of fast and low-complexity multiplier over GF(2$\^$m/). The proposed multiplier based on the irreducible all one polynomial (AOP) of degree m, to reduced the system's complexity. It composed of Cyclic Shift, Partial Product, and Modular Summation Blocks. Also it consists of (m+1)$^2$2-input AND gates and m(m+1) 2-input XOR gates. Out architecture is very regular, modular and therefore, well-suited for VLSI implementation.

  • PDF

아파트 외부공간에 따른 블록포장의 하자 연구

  • Park, Geun-Hye;Jang, Cheol-Gyu;Lee, U-Seong;Jeong, Seong-Gwan
    • Proceedings of the Korean Institute of Landscape Architecture Conference
    • /
    • 2017.10a
    • /
    • pp.103-105
    • /
    • 2017
  • 대구광역시 동구에 위치한 'A'아파트를 중심으로 진입로, 보도, 보차도, 휴게공간, 체육공간의 점토벽돌블록포장, 소형고압블록포장, 인조화강석블록포장에 대해서 발생 하자를 조사하였다. 먼저 하자분석을 위해 하자유형 및 종류를 정의하여 현장조사표를 개발하였으며, 이를 바탕으로 각 공간 및 블록종류에 따른 하자를 조사 분석하였다. 그 결과 진입로의 소형고압블록은 16.14개/$m^2$, 보도의 소형고압블록은 12.04개/$m^2$, 점토벽돌블록포장은 9.55개/$m^2$, 인조화강석블록은 3.66개/$m^2$로 나타났다. 보차도의 소형고압블록은 10.82개/$m^2$, 인조화강석블록은 2.59개/$m^2$, 휴게공간과 체육공간의 점토벽돌블록은 각각 13.64개/$m^2$, 6.02개/$m^2$개의 하자가 발생하였다. 다음으로 블록별 발생하자 종류를 살펴보면, 소형고압블록에서는 골재분리, 인조화강석블록에서는 얼룩이 가장 많았고, 점토벽돌블록은 보도에서는 침하가, 휴게공간과 체육공간에서는 얼룩의 발생량이 많았다. 마지막으로 하자발생부위별로 살펴보면 진입로, 보도, 보차도에서는 경계부의 하자가 많이 발생했으며, 휴게공간에서는 중앙부의 하자가 많이 나타났다. 반면 체육공간에서는 중앙부와 경계부의 차이가 거의 나지 않은 것으로 분석되었다.

  • PDF

Clustering Scheme for (m,k)-Firm Streams in Wireless Sensor Networks

  • Kim, Ki-Il
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.2
    • /
    • pp.84-88
    • /
    • 2016
  • As good example of potential application-specific requirement, (m,k)-firm real-time streams have been recently introduced to deliver multimedia data efficiently in wireless sensor networks. In addition to stream model, communication protocols to meet specific (m,k)-firm real-time streams have been newly developed or extended from existing protocols. However, since the existing schemes for an (m,k)-firm stream have been proposed under typical flat architecture, the scalability problem remains unsolved when the number of real-time flows increases in the networks. To solve this problem, in this paper, we propose a new clustering scheme for an (m,k)-firm stream. The two different clustering algorithms are performed according to either the (m,k)-firm requirement or the deadline. Simulation results are presented to demonstrate the suitability of the proposed scheme under hierarchical architecture by showing that its performance is acceptable irrespective of the increase in the number of flows.