• Title/Summary/Keyword: M.I.V

Search Result 2,505, Processing Time 0.032 seconds

A Clinical Report on 30 Cases with H.I.V.D by Scalp Acupuncture (두침(頭鍼)을 시행한 요추간판탈출증 환자 30례에 대한 임상고찰(臨床考察))

  • Jang, Suk-geun;Kim, Young-wha;Kang, Jae-hui;Kim, Jung-ho;Yim, Yun-kyoung;Lee, Hyun;Lee, Byung-ryul
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.252-260
    • /
    • 2003
  • Objective : The purpose of this report is to examine the effects of Scalp Acupuncture therapy in the H.I.V.D patients. Methods : We investigated 30 patients suffering from low back pain with sciatica which were admitted to Cheonan O. M. hospital from Aug. 1, 2001 to Jan. 31. 2002. 30 patients had a diagnosis of herniated lumbar intervertebral disc by Lumbar-C.T or Lumbar-M.R.I. we treated 30 patients by Scalp Acupuncture therapy. Results : 1. We operated Scalp Acupuncture on the foot-motion sensory area(족운동감각구), the sensory area(감각구) 2. In the result of treatment due to clinical symptoms, leg radiating pain was more effective than any other clinical symptoms. 3. The efficacy of Scalp Acupuncture therapy was 83.3%(when we set a standard things more than fair) and 63.3%(when we set a standard things more than good). Conclusions: The Scalp Acupuncture therapy is effective of H.I.V.D patients, but we thought that it needed to prove effects of Scalp Acupuncture therapy for efficient application by more clinical reports.

  • PDF

Study on Economical M&V Methoodology for the Lighting Control System (조명제어시스템 경제적인 실적확인 기법 연구)

  • Choi, Kyung-Shik;Han, Seung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.163-167
    • /
    • 2009
  • Although the domestic electric power consumption of lighting have shared 20${\sim}$30 % of the national electric power consumption, the spread of lighting control system which can reduce the electric power consumption have been insignificant. The government have set the demonstration project and given the incentive to promote the spread of lighting control system since 2008. The M&V (Measurement and Verification) methodology for lighting control system have not been set yet in our country, but the direct measurement was suggested in US. The direct measurement methodology can increase the accuracy of measurement, but it cost much money to burden a customer. This study have suggested a new M&V methodology which cost low and is simple relatively. I had measured the amount of electric consumption through both the direct measurement and the new M&V program computation, and have analyzed the deviation. The amount of electric consumption measured by the new M&V program computation have agreed with one by the direct measurement within the error range of the instrumentation in case of lab scale test, and the 4${\sim}$8 % deviation have existed in case of field evaluation.

  • PDF

Determining Potassium Bromate in the Inhalable Aerosol Fraction in Workplace Air with Ion Chromatography

  • Kowalska, Joanna;Lis, Monika;Biesaga, Magdalena
    • Safety and Health at Work
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2021
  • Background: The article presents the results of studies performed in order to develop a new method of airborne potassium bromate(V) determination at workplaces. Methods: The method is based on a collection of the inhalable fraction of potassium bromate(V) using the IOM Sampler, then extraction of bromates with deionized water and chromatographic analysis of the obtained solution. The analysis was performed using ion chromatography with conductometric detection. The tests were performed on a Dionex IonPac®AS22 analytic column (250 × 4 mm, 6 ㎛) with AG22 precolumn (50 × 4 mm 11 ㎛). Results: The method provides for potassium bromate(V) determination within the concentration range of 0.043 ÷ 0.88 mg/m3 for an air sample of 0.72 m3 in volume, i.e., 0.1-2 times the exposure limit value as proposed in Poland. The method was validated in accordance with PN-EN 482. The obtained validation data are as follows: measuring range: 3.1-63.4 ㎍/mL, limit of detection (LOD) = 0.018 ㎍/mL and limit of quantification (LOQ) = 0.053 ㎍/mL. The developed method has been tested in the work environment, on laboratory employees having contact with potassium bromate(V). Conclusion: The analytical method allowed the determination of the inhalable fraction of airborne potassium bromate(V) at workplaces and can be used to assess occupational exposure.

Characteristics of the 2-D SSIMT using a CMOS Process (CMOS 공정을 이용한 2차원 SSIMT의 특성)

  • Song, Youn-Gui;Ryu, Ji-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.697-700
    • /
    • 2007
  • A novel 2-Dimensional Suppressed Sidewall Injection Magnetotransistor (SSIMT) with high linearity has been fabricated on the standard CMOS technology and experimentally verified. The novel 2-Dimensional SSIMT overcomes the restriction of the standard CMOS technology. Experimental results of the fabricated 2-Dimensional SSIMT show that the variation of each collector output currents are extremely linear as a function of magnetic field from -200mT to 200mT at $I_B = 1 mA,\;V_{CE} = 5 V\;and\;V_{SE} = 5 V$. The relative sensitivity shows up to 13 %/T. The measured nonlinearity of the fabricated device is about 0.9%.

Impact of Expanded Small Alkyl-Binding Pocket by Triple Point Mutations on Substrate Specificity of Thermoanaerobacter ethanolicus Secondary Alcohol Dehydrogenase

  • Dwamena, Amos K.;Phillips, Robert S.;Kim, Chang Sup
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.3
    • /
    • pp.373-381
    • /
    • 2019
  • Site-directed mutagenesis was employed to generate five different triple point mutations in the double mutant (C295A/I86A) of Thermoanaerobacter ethanolicus alcohol dehydrogenase (TeSADH) by computer-aided modeling with the aim of widening the small alkyl-binding pocket. TeSADH engineering enables the enzyme to accept sterically hindered substrates that could not be accepted by the wild-type enzyme. The underline in the mutations highlights the additional point mutation on the double mutant TeSADH introduced in this work. The catalytic efficiency ($k_{cat}/K_M$) of the ${\underline{M151A}}$/C295A/I86A triple TeSADH mutant for acetophenone increased about 4.8-fold higher than that of the double mutant. A 2.4-fold increase in conversion of 3'-methylacetophenone to (R)-1-(3-methylphenyl)-ethanol with a yield of 87% was obtained by using ${\underline{V115A}}$/C295A/I86A mutant in asymmetric reduction. The ${\underline{A85G}}$/C295A/I86A mutant also produced (R)-1-(3-methylphenyl)-ethanol (1.7-fold) from 3'-methylacetophenone and (R)-1-(3-methoxyphenyl)-ethanol (1.2-fold) from 3'-methoxyacetophenone, with improved yield. In terms of thermal stability, the ${\underline{M151A}}$/C295A/I86A and ${\underline{V115A}}$/C295A/I86A mutants significantly increased ${\Delta}T_{1/2}$ by $+6.8^{\circ}C$ and $+2.4^{\circ}C$, respectively, with thermal deactivation constant ($k_d$) close to the wild-type enzyme. The ${\underline{M151A}}$/C295A/I86A mutant reacts optimally at $70^{\circ}C$ with almost 4 times more residual activity than the wild type. Considering broad substrate tolerance and thermal stability together, it would be promising to produce (R)-1-(3-methylphenyl)-ethanol from 3'-methylacetophenone by ${\underline{V115A}}$/C295A/I86A, and (R)-1-phenylethanol from acetophenone by ${\underline{M151A}}$/C295A/I86A mutant, in large-scale bioreduction processes.

Measurement of $^{93}Nb(n,n{\alpha})^{89m}Y$, $^{93}Nb(n,{\alpha})^{90m}Y$ and $^{93}Nb(n,2n)^{92m}Nb$ Cross Sections for 14 MeV Neutrons ($^{93}Nb(n,n{\alpha})^{89m}Y$, $^{93}Nb(n,{\alpha})^{90m}Y$$^{93}Nb(n,2n)^{92m}Nb$ 반응의 14 MeV 중성자 반응 단면적 측정)

  • Kim, Y.S.;Kim, N.B.;Chung, K.H.;Bak, H.I.
    • Nuclear Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.92-96
    • /
    • 1986
  • The $^{93}Nb(n,n\alpha)^{89m}Y$, $^{93}Nb(n,{\alpha})^{90m}Y$ and $^{93}Nb(n,2n)^{92m}Nb$ cross sections at a neutron energy of 14.6 MeV have been measured relative to the $^{27}Al(n,p)^{27}Mg$ and $^{27}Al(n,{\alpha})^{24}Na$ cross sections. A small accelerator utilizing $T(D,n)^4He$ reaction was used as a neutron source and the neutron energy spread is about 0.4MeV at the sample. All induced activities were measured with a 70cc HPGe detector in the same geometry.

  • PDF

I-V characteristics of ground electrode fabricated using an aluminium scrap (알루미늄 스크랩을 이용하여 제작한 접지 전극의 전압-전류 특성)

  • 이우선;정용호;박진성
    • Electrical & Electronic Materials
    • /
    • v.9 no.8
    • /
    • pp.806-812
    • /
    • 1996
  • I-V characteristics of ground electrode fabricated using an aluminium scrap are presented. We fabricated several shapes of aluminium scraps and aluminium electrodes. The results show that the current of aluminium electrode increased linearly by the voltage increase. AC breakdown voltage of copper plate electrode was higher than that of aluminium electrode. AC breakdown current of aluminium electrode was higher than that of copper plate electrode. As applied voltage increased, grounding resistance of aluminum electrode decreased linearly.

  • PDF

MEASUREMENT OF LINE PROFILE STEEPNESS AS A POSSIBLE TOOL FOR DEDUCING A TOTAL MAGNETIC FLUX NEAR A NEUTRAL LINE

  • GRIGORYEV V. M.;KOBANOV N. I.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.233-234
    • /
    • 1996
  • For obtaining estimates of a total magnetic flux, we propose to use measurements of ${\partial}I/{\partial}{\lambda}$. obtained by a modulation method which is formally identical to Stokes V-parameter measurements. In this case the polarization is not analyzed. It is advisable to use in measurements two parts of the spectral line wing.

  • PDF

ISOTOPIC-SPECTRAL DETERMINATION OF CARBON IN HIGH PURITY INORGANIC MATERIALS

  • Lee, V.N.;Nemets, V.M.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.477-480
    • /
    • 1995
  • Isotopic-spectral method [I] was applicated for determination of carbon in silicate materials (pure silica, guartz glasses, geological probs etc.). Isotopic heterogeneous balancing of carbon in gaseous phase and solid samples was carried out at the temperature of $1500-1900^{\circ}K$. Spectroscopic measuring of isotope concentration in a balanced gas was made using the electron-vibrational band heads of CO molecules excited in HF discharge. Limits of detection of carbon concentrations appear to be $n^*10^{-6}$.

  • PDF

OLED용 Al 음전극 제작 및 I-V 특성

  • Geum Min-Jong;Gwon Gyeong-Hwan
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.09a
    • /
    • pp.102-105
    • /
    • 2005
  • In this study Al electrode for OLED was deposited by FTS(Facing Targets Sputtering) system which can deposit thin films with low substrate damage. The Al thin films were deposited on the cell (LiF/EML/HTL/Bottom electrode) as a function of working gas such as Ar, Kr or mixed gas. Also Al thin films were prepared with working gas pressure (1, 6 mTorr ). The film thickness and I-V curve of Al/cell were evaluated by $\alpha$-step and semiconductor parameter (HP4156A) measurement.

  • PDF