• Title/Summary/Keyword: M-B curve

Search Result 374, Processing Time 0.031 seconds

Evaluation of noise level in the training ship, Saehaerim (실습선 새해림호의 선내 소음도에 대한 평가)

  • HWANG, Bo-Kyu;KIM, Min-Son
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.57 no.1
    • /
    • pp.69-77
    • /
    • 2021
  • The noise environment was evaluated using the ISO recommended NR evaluation curve and PSIL (Preferred Sound Interference Level) in order to investigate the onboard educational environment according to the noise in the Motor Vessel Saehaerim, a fishing training ship under making way. As a result, NRNs were measured at 37-61 dB in accommodation areas, 44-56 dB in work areas, 37-57 dB in educational and conference areas, 83-103 dB in engine areas and 65.3 dB and 51.2 dB in the work and education areas respectively based on PSIL. The NRNs, which evaluated the cabin of the experimental ship according to the purpose, exceeded all of the indoor standard noise recommended by the ISO, and the PSIL had a generally short conversational distance within 0.25-2.3 m and 0.75-1.3 m for teaching and work areas.

Studies on Digitalis Receptor Desensitization in Rat Ventricle

  • Lee, Shin-Woong-;Jang, Tae-Soo
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.301-301
    • /
    • 1994
  • $^3$H〕Ouabain binding parameters(K$\_$D/ and B$\_$max/,) in homogenates prepared fpom control rat ventricular strip and Langendorff preparations which were not previously exposed to ouabain were compared to those in homogenates from ventricular strip and Langendorff preparations that had been first exposed to a complete ouabain dose-response curve(10$\^$-7/M to 10$\^$-4/ M). In rat ventricular strips and Langendorff perfused rat heart preparations, cumulative dose-response cruves of ouabain revealed biphasic positive inotropic effects, a "low-dose" and a "high-dose" effect with ED$\_$50/ values of 0.5${\mu}$M and 35${\mu}$M ouabain, respectively- The "low-dose" effect in rat ventricular strips disappeared or was diminished significantly when the ouabain dose-response curve wag repeated after the washout of the effects of the first curve, whereas the maximal "high-dose" effect was identical in both exposures to oubain. However, there was no change in the "low-dose" effects in both sets of the Langendorff perfused hearts. The contractile activity of the pre-exposed strips did not indicate the presence of residual ouabain since their basal contractile force was decreased 10% compared to initial control. 〔$^3$H〕Ouabain binding parameters, K$\_$D/ and B$\_$max/, were not changed comparing homogenate of control ventricular strips with that of strips pre-exposed to ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site(${\alpha}$$_2$ isoform).

  • PDF

Studies on Digitalis Receptor Desensitization in Rat Ventricle (쥐 심실에서 Digitalis Receptor Desensitization에 관한 연구)

  • 이신웅;이정수;장태수
    • Biomolecules & Therapeutics
    • /
    • v.2 no.2
    • /
    • pp.114-119
    • /
    • 1994
  • [$^3$H]Ouabain binding parameters ( $K_{D}$ and $B_{max}$) to control rat ventricular strips and Langendorff preparations which were not previously exposed to ouabain were compared with those to both preparations that had been first exposed to a complete ouabain dose range of dose-response curve (10$^{-8}$ to 10$^{4}$M). In rat ventricular strips and Langendorff perfused heart preparations, cumulative dose-response curves of ouabain revealed biphasic positive inotropic effects, a "low-dose" effect and a "high-dose" effect with E $d_{50}$ values of 0.5 $\mu$M and 35 $\mu$M ouabain, respectively. The "low-dose" effect in ventricular strip disappeared or was diminished significantly when the ouabain dose-response curve was repeated after the washout of the effects of the first dose-response curve, whereas there were no significant differences in the maximal "high-dose"effect in both exposures to oubain. However, both of the control and ouabain-preexposed Langendorff perfused hearts revealed the same low-dose effects. The $K_{D}$ value for [$^3$H] ouabain binding and the ouabain binding site concentration ( $B_{max}$) estimated by [$^3$H]ouabain displacement assay in control preparations were 230 nM and 2 pmol/mg protein, respectively. [$^3$H]Ouabain binding parameters were not changed by repeated exposure to high concentrations of ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site ($\alpha$$_2$isoform).).).).).

  • PDF

3-Dimensional Free Form Design Using an ASMOD (ASMOD를 이용한 3차원 자유 형상 설계)

  • 김현철;김수영;이창호
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.5
    • /
    • pp.45-50
    • /
    • 1998
  • This paper presents the process generating the 3-dimensional free f o r m hull form by using an ASMOD(Adaptive Spline Modeling of Observation Data) and a hybrid curve approximation. For example, we apply an ASMOD to the generation of a SAC(Sectiona1 Area Curve) in an initial hull form design. That is, we define SACS of real ships as B-spline curves by a hybrid curve approximation (which is the combination method of a B-spline fitting method and a genetic algorithm) and accumulate a database of control points. Then we let ASMOD learn from the correlation of principal dimensions with control points and make the ASMOD model for SAC generation. Identically, we apply an ASMOD to the generation of other hull form characteristic curves - design waterline curve, bottom tangent line, center profile line. Conclus~onally we can generate a design hull form from these hull form characteristic curves.

  • PDF

Contrast-Detail Phantom을 이용한 CR에서 Image Plate의 사용 횟수에 따른 Contrast-Detail Curve의 변화

  • Lee, Seung-Cheol;Park, Jang-Heum;Kim, Jae-Dong;Park, Chang-Hyeon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.7-13
    • /
    • 2005
  • Purpose : Image plate (IP) is substituted for film in computed radiography. This study is to investigate into a variation of contrast and detail by the number used of image plate in computed radiography. Materials and Methods : A Contrast-Detail(CD)-RAD 2.0 phantom(Nijmegen hospital, The Netherlands) was used for this study. The computed radiography(CR) CD-RAD phantom images were acquired at 40 kVp, 160 mA, 1.6 mAs, and small focus with the Shimadzu general radiography UD-150B-10 system and Fuji FCR 5000 image process system with speed of 200. The IP used including once, 5000 times, and 10000 times also was used. The numerical value of image quality figures (IQF) was produced by CD-RAD analyser(the program is installed in the directory), and then contrast-detail curve was drawn. Results : In this study, the value of IQF was 3.53 in IP used once, 3.40 in 5000 times, and 3.22 in 10000 times. Conclusions : There was a variation of contrast-detail curve by the number used of IP with contrast-detail phantom in computed radiography. Therefore, it is necessary that the IP with lower IQF and a shift of contrast-detail curve to the lower left part is used.

  • PDF

TENSOR PRODUCT SURFACES WITH POINTWISE 1-TYPE GAUSS MAP

  • Arslan, Kadri;Bulca, Betul;Kilic, Bengu;Kim, Young-Ho;Murathan, Cengizhan;Ozturk, Gunay
    • Bulletin of the Korean Mathematical Society
    • /
    • v.48 no.3
    • /
    • pp.601-609
    • /
    • 2011
  • Tensor product immersions of a given Riemannian manifold was initiated by B.-Y. Chen. In the present article we study the tensor product surfaces of two Euclidean plane curves. We show that a tensor product surface M of a plane circle $c_1$ centered at origin with an Euclidean planar curve $c_2$ has harmonic Gauss map if and only if M is a part of a plane. Further, we give necessary and sufficient conditions for a tensor product surface M of a plane circle $c_1$ centered at origin with an Euclidean planar curve $c_2$ to have pointwise 1-type Gauss map.

Growth of high quality ZnTe epilayers used for an far-infrared sensor and radiation detector

  • Kim, B. J.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.105-110
    • /
    • 2002
  • ZnTe epilayers have been successfully grown on (100) CaAs substrate by hot wall epitaxy (HWE) with Zn reservoir. Optimum growth condition has been determined by a four-crystal rocking curve (FCRC). It was found that Zn partial pressure from h reservoir has a strong influence on the quality of grown films. Under the determined optimum growth condition, ZnTe epitaxial films with thickness of 0.72~24.8${\mu}m$ were grown for studying the effect of the thickness on crystalline quality. The FCRC results indicated that the quality of ZnTe films becomes higher rapidly with increase of thickness up to 6${\mu}{\textrm}{m}$. The best value of the FWHM of the few crystal rocking curve, 66 arcsec, was obtained on the film with $12{\mu}m$ in thickness. Until now, this result shows the best quality of ZnTe/GaAs films in reported.

ECC Processor Supporting NIST Elliptic Curves over GF(2m) (GF(2m) 상의 NIST 타원곡선을 지원하는 ECC 프로세서)

  • Lee, Sang-Hyun;Shin, Kyung-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.190-192
    • /
    • 2018
  • This paper describes a design of an elliptic curve cryptography (ECC) processor that supports five pseudo-random curves and five Koblitz curves over binary field defined by the NIST standard. The ECC processor adopts the Lopez-Dahab projective coordinate system so that scalar multiplication is computed with modular multiplier and XORs. A word-based Montgomery multiplier of $32-b{\times}32-b$ was designed to implement ECCs of various key lengths using fixed-size hardware. The hardware operation of the ECC processor was verified by FPGA implementation. The ECC processor synthesized using a 0.18-um CMOS cell library occupies 10,674 gate equivalents (GEs) and 9 Kbits RAM at 100 MHz, and the estimated maximum clock frequency is 154 MHz.

  • PDF

Improvement of Magnetic Properties of Nano-crystalline Nd-Fe-B Alloys (나노 결정형 Nd-Fe-B 합금의 자기적 특성 향상)

  • Lee Dae Hoon;Jang Taesuk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.67-70
    • /
    • 2005
  • [ $a-Fe/Nd_2Fe_{14}B$ ]기 이상나노복합합금(two-phase nanocompositie alloy)의 자기적 특성 향상을 위하여, $Nd_9Fe_{84}B_7$ 조성의 합금을 급속 응고법과 등온열처리를 이용하여 제조한 후, 공정 조건의 변화에 따른 상, 미세조직, 자기특성의 변화 등을 조사하였다. 주어진 Nd-Fe-B 삼원계 합금을 35 m/s 이상에서 급랭 응고하였을 때 완전한 비정질 합금을 얻을 수 있었으며, 최적 자기특성을 얻기 위한 적정 열처리 구역은 $700^{\circ}C$/10 - 15분, 725$^{\circ}C$/7 - 12분, $750^{\circ}C$/5 - 7분으로 조사되었다. 이 구역들에서 열처리된 합금들은 모두 매끄러운 감자곡선(demagnetization curve)을 나타내, a-Fe와 $Nd_2Fe_{14}B$사이의 교환상호결합이 잘 일어나고 있음을 알 수 있었으며, 이때 a-Fe와 $Nd_2Fe_{14}B$의 평균 입자 크기는 각각 약 10nm와 40$\~$60 nm였다. 한편 상 전개의 차이에도 불구하고 열처리 후에는 모든 합금들이 $60\%$ 이상의 $M_r/M_s$ 비율을 나타내 열처리 조건의 변화에 관계없이 교환상호작용은 일어나고 있음을 알 수 있었다.

  • PDF

Quantitative Measurement of Surfactant Protein B mRNA by Filter Hybridization (Filter Hybridization 방법에 의한 Surfactant Protein B mRNA의 정량측정)

  • Park, Sung-Soo;Lee, Dong-Hoo;Shin, Dong-Ho;Lee, Jung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.3
    • /
    • pp.242-247
    • /
    • 1992
  • Background: The ability to precisely measure specific mRNA levels by hybridization to complementary DNA probes is an important tool for analyzing the regulation of gene expression. Surfactant proteins have important roles in regulating surfactant metabolism as well as in determing its physical properties. Method: The complete coding regions for rat surfactant protein complementary DNA of surfactant protein B were subcloned into pGem 3Z or 4Z such that either antisense or sense transcripts were obtained by using SP 6 RNA polymerase. Surfactant protein B mRNA was measured by filter hybridization. Results: Equation of standard curve between counts per minute (Y) and surfactant protein B mRNA transcript input (X) was Y=2034.9 X+159.1. Correlation coefficient was 1.0. Couclusions: Filter hybridization assay is suited to situation when rapid, accurate quantitation of multiple samples is required.

  • PDF