• Title/Summary/Keyword: M--Spectrum

Search Result 1,948, Processing Time 0.029 seconds

Synthesis and Emulsion Properties of Self-emulsifiable Polyethylene Waxes (자기유화 폴리에틸렌 왁스의 합성 및 에멀젼 특성 연구)

  • Yang, Jeongin;Lee, Sangjun;Shin, Jihoon;Han, Won Hee;Hong, Min Hyuk;Kim, Young-Wun
    • Applied Chemistry for Engineering
    • /
    • v.28 no.6
    • /
    • pp.670-678
    • /
    • 2017
  • Self-emulsifiable polyethylene (PE) wax was prepared using acrylic acid grafted PE wax with potassium hydroxide and various emulsifiers for the economic production of PE wax emulsion. Modification reaction completion was confirmed that the peak from carbonyl group of acrylic acid disappeared and the new peak from carboxylic acid salts appeared in the FT-IR (Fourier transform infrared) spectrum data. Self-emulsifiable properties of the modified PE wax were investigated by the emulsion size and the stability of wax emulsion without any additional emulsifiers. According to self-emulsifiable properties, the emulsion size and stability were varied on the concentration and structure of the emulsifier. The greater emulsion concentration and hydrophilic poly(ethylene oxide) (PEO) characteristics of the emulsifier resulted in the smaller emulsion size and better emulsion stability. In addition, the use of emulsifiers mixture was more effective to obtain smaller size and uniform distribution of emulsion than that of single emulsifier in PE wax modification reaction. Especially, modified PE wax with OAE-5 and LAE-15 emulsifiers mixture shows excellent performance in terms of the smallest emulsion size ($4.34{\mu}m$) and emulsion stability.

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

The Study of Optical Biopsy‘s Usefulness in Radiotherapy (방사선 치료에서 광학적 생검의 유용성에 관한 연구)

  • ;;Muller M.G.,;Feld M.S.
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • The prior purpose of this study is to introduce a optical biopsy and evaluate whether the optical biopsy, real-time, non-invasive technique, is a reliable tool to assess response to radiotherapy Four healthy volunteers, and four patients with inflammatory conditions of the oral cavity participated on the study. was obtained from each person enrolled in the study. Using FastEEM(Ercited Emission Matrix) as a optical biopsy tool, normal and tumor spectra are taken from the normal and the tumor regions. And then second optical biopsy are taken from the tumor regions in 4 patients with time delay at 7days.. Using a diagnostic algorithm, made by Gillenwater based on spectra excited at 337nm The Optical Biopsy turned out to be more suited for tumor diagnostic resulting in significant difference fluorescence spectra. The fluorescence intensity of cancerous tissue showed a higher position. The second fluorescence intensity of optical biopsy of cancerous oral tissue has more smaller than the first result. I conclude that optical biopsy, which technique don't need to remove tissue sample from body, and is a real time , and non-invasive measurement is a reliable tool to access to radiotherapy because FastEEM can do measure the variation of the tissue composition chemical, biological, and morphological after radiotherapy. Based on the fluorescence spectrum are taken from the optical biopsy in normal and tumor spectra as well as tumor spectra after 7days.

  • PDF

Membranous Nephropathy Associated with Epstein-Barr Virus Infection in a Child (소아에서 엡스타인-바 바이러스 감염과 관련한 막성 신병증 1례)

  • Lee, Eun-Hee;Lim, Dong-Hee;Yim, Hyung-Eun;Yoo, Kee-Hwan;Won, Nam-Hee;Hong, Young-Sook;Lee, Joo-Won
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.88-92
    • /
    • 2008
  • Infection of Epstein-Barr virus(EBV) gives rise to a broad spectrum of clinical manifestations in children. Although renal involvement is rare, diverse renal manifestations are known from hematuria to acute renal failure. Secondary membranous nephropathy(MN) associated with systemic EBV infection is an uncommon renal pathology and only two cases have been reported. We are adding another case of MN associated with EBV infection in a child. An 8-year-old girl was admitted for renal biopsy. She had been followed up for microscopic hematuria and intermittent proteinuria for 5 months. There had been no specific findings in serology and radiology. Tonsil biopsy had been done due to exudative tonsillar hypertrophy and enlarged multiple cervical lymph nodes. And it showed EBV-associated lymphoproliferative findings. Serologic tests for EBV showed positive evidence of recent infection; viral capsid antigen(VCA) IgM was borderline positive, VCA IgG and early antigen IgG were positive, and EB nuclear antigen IgG was negative. In Situ Hybridization of tonsil for EBV mRNA was positive. Because her proteinuria and hematuria were aggravated at that time(protein 3 +, RBC >60/HPF), renal biopsy was done. Renal biopsy showed the findings of MN, characterized by thickened capillary walls with epimembranous spikes on light microscopy and subepithelial, mesangial and subendothelial electron dense deposits on electron microscopy. On immunofluorescence microscopy, IgG, C1q, kappa and lambda chains were positive. After steroid administration, proteinuria and hematuria resolved gradually within 6 months.

  • PDF

Measurement of Distributed Temperature and Strain Using Raman OTDR with a Fiber Line Including Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서가 있는 광섬유 라인에 라만 OTDR을 이용한 분포 온도 및 변형률 측정 가능성에 대한 연구)

  • Kwon, Il-Bum;Byeon, Jong-Hyun;Jeon, Min-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • In this study, we propose a novel fiber optic sensor to show the measurement feasibility of distributed temperature and strains in a single sensing fiber line. Distributed temperature can be measured using optical time domain reflectometry (OTDR) with a Raman anti-Stokes light in the sensing fiber line. Moreover, the strain can be measured by fiber Bragg gratings (FBGs) in the same sensing fiber line. The anti-Stokes Raman back-scattering lights from both ends of the sensing fiber, which consists of a 4 km single mode optical fiber, are acquired and inserted into a newly formulated equation to calculate the temperature. Furthermore, the center wavelengths from the FBGs in the sensing fiber are detected by an optical spectrum analyzer; these are converted to strain values. The initial wavelengths of the FBGs are selected to avoid a cross-talk with the wavelength of the Raman pulsed pump light. Wavelength shifts from a tension test were found to be 0.1 nm, 0.17 nm, 0.29 nm, and 0.00 nm, with corresponding strain values of $85.76{\mu}{\epsilon}$, $145.55{\mu}{\epsilon}$, $247.86{\mu}{\epsilon}$, and $0.00{\mu}{\epsilon}$, respectively. In addition, a 50 m portion of the sensing fiber from $30^{\circ}C$ to $70^{\circ}C$ at $10^{\circ}C$ intervals was used to measure the distributed temperature. In all tests, the temperature measurement accuracy of the proposed sensor was less than $0.50^{\circ}C$.

Establishment of the Physicochemical and Radiological Database of Raw Materials and By-Products in Domestic Distribution (국내 유통중인 원료물질 및 공정부산물의 물리화학적 및 방사선적 특성 데이터베이스 구축)

  • Lim, Chung-Sup;Lim, Jong-Myoung;Park, Ji-Young;Chung, Kun Ho;Kim, Chang-Jong;Chang, Byung-Uck;Ji, Young-Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.331-341
    • /
    • 2016
  • To evaluate the physicochemical and radiological properties of raw materials and by-products in domestic distribution, about 220 samples with 16 species were prepared. We measured the energy spectrum and the chemical content, such as U, Th, and K, using a $LaBr_3$ scintillation detector and ED-XRF. In addition, HPGe detector was used to analyze the radioac-tivity of $^{234}Th$, $^{234}mPa$, and $^{214}Bi$ in uranium decay series and $^{228}Ac$, $^{212}Pb$, and $^{208}Tl$ in thorium decay series, and $^{40}K$. The correlation between characteristic variables, such as the count rate in several ROIs, chemical content, and radioactivity, was assessed to infer the radioactivity of natural radionuclides through a rapid screening method. Based on the results, a characteristic database for raw material and by-product in domestic distribution was established and it will provide useful information in the analysis procedure and improve the accuracy and reproducibility in the analysis of natural radionuclides.

Geographical origin discrimination of Korean variety, Angelica gigas Nakai by using TDU (Thermal Desorption Unit)-GC/MS (TDU-GC/MS를 이용한 한국품종 참당귀 국산 판별 기법)

  • Lee, Mi-Na;Kim, Yoon-Suk;Kim, Won-Il;Kim, Jeong-Gyu;Kwon, Oh-Kyung
    • Journal of Applied Biological Chemistry
    • /
    • v.63 no.1
    • /
    • pp.29-33
    • /
    • 2020
  • The objective of this study was to develop a fast and accurate method of variety discrimination and geographical discrimination origin of Korean angelica (Korean variety, Angelica gigas Nakai) by using TDU-GC/MS. Two peaks of decursin and decursinol, which are coumarin derivatives were identified in the range of Total Ion Chromatogram (TIC) RT 26.9-27.2 of the Korean angelica by GC/MS analysis at the time of condensation in a refrigerated condensation system after thermal desorption of sample extracts. In case of Chinese angelica (Chinese variety), ligustilide peak was detected at the RT 17.2. In order to investigate the difference of volatile components according to the geographical origin of Korean variety, the mass spectra were measured by TDU-GC/MS at the range of m/z 40-400 amu. The TIC of domestic cultivation and Chinese cultivation of the Korean variety, Angelica gigas Nakai showed the same tendency as a whole. However, in partial scans of TIC, two peaks detected at 15.54 and 16.05 of RT showed different peak patterns between Korean angelica (Korean variety) cultivated in Korea and in China. The ratio of Peak A (RT 15.54) and B (RT 16.05) was 0.0-0.2 for domestic cultivation and 0.5-2.8 for Chinese cultivation, confirming the possibility of discriminating origin by comparing the TIC peak pattern of TDU-GC/MS.

Purification of Acorn Tannin Hydrolyzing Enzyme of Aspergillus sp. AN-11 and Physiochemical Properties of It (Aspergillus sp. AN-11이 분비하는 도토리 Tannin 분해효소(分解酵素)의 정제(精製)와 물리화학적(物理化學的) 성질(性質))

  • Chae, Soo-Kyu;Yu, Tai-Jong;Kim, Byung-Mook
    • Korean Journal of Food Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.333-341
    • /
    • 1983
  • Tannase of Aspergillus sp. AN-11 isolated from contaminated acorns was purified by a procedure involving ammonium sulfate precipitation, DEAE-cellulose column chromatography and Sephadex G-200 gel filtration. Physiochemical properties of the purified tannase was investigated. Tannase was purified about 37 folds with the yield of 49% from the culture broth of Aspergillus sp. AN-11. The purified tannase was homogeneous on polyacrylamide gel disc electrophoresis and was dissociable into two identical subunits on SDS-polyacrylamide gel electrophoresis. The molecular weight of the tannase was determined to be 200,000 by gel filtration on Sephadex G-200. The purified tannase showed a typical protein ultraviolet spectrum. The enzyme had a optimum pH 5.5 and optimum temperature at 30 to $40^{\circ}C$. The enzyme was stable at a pH range from 5.0 to 6.5 and at the temperature below $30^{\circ}C$. The enzyme was inactivated remarkably by $CuCl_2$ and $ZnCl_2. The Km value of the enzyme was $7.58{\times}10^{-4}\;M$.

  • PDF

A STUDY ON THE SHAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENTS TO DENTIN ACCORDING TO CURING TIME INDUCED BY ARGON LASER (아르곤 레이저의 조사시간에 따른 광중합형 글래스 아이오노머 시멘트의 상아질에 대한 전단결합강도에 관한 연구)

  • Cho, Young-Lin;Hwang, Ho-Keel;Cho, Young-Gon;Oh, Haeng-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.267-277
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of light-cured glass ionomer cements to dentin surface according to curing time induced by argon laser. In this study, 160 extracted human molars with sound crown were used. The dentin surface of these teeth were exposed with high speed diamond bur under water spray and polished with 120, 320, 400, 800, 1200 grits sand paper. 160 extracted human molars were randomly assigned into four groups (control, experimental 1, 2 & 3) with 40 teeth each. Control group used a visible light curing unit, XL 1000(3M Co., U.S.A) and experimental groups used argon laser($SPECTRUM^{TM}$). And then each group subdivided into two groups (A, B) according to filling materials. Subdivided A group used Fuji II LC(GC Co., Japan), B group used Vitremer(3M Co., U.S.A). The curing units and curing time of each group were as follows : Control group : visible light, 40 seconds Experimental group 1 Experimental group 2 Experimental group 3 : argon laser, 10 seconds : argon laser, 20 seconds : argon laser, 30 seconds The glass ionomer cements were bonded to dentin surface of each specimen. The specimens were stored in 100% relative humidity at 37"c for 7days. And then, the shear bond strength were measured by universal testing machine(Shimatzu Co. Japan) at crosshead speed of 5mm/min and 100kg in full scale and analyzed statistically. The following results were obtained : 1. Experimental group 2-A showed the highest shear bond strength with $9.87{\pm}1.24$ kgf and control group B showed the lowest shear bond strength with $4.08{\pm}0.78$ kgf(P<0.01). 2. The Fuji II LC showed higher shear bond strength with $9.49{\pm}1.24$ kgf than that of the Vitremer with $4.23{\pm}1.24$ kgf. There was significant difference between Fuji II LC and Vitremer(p<0.01). 3. There was no significant differences among experimental groups according to curing time induced by argon laser. 4. There was no significant differences between control group and experimental groups according to curing units.

  • PDF

Electrical Properties of ITO and ZnO:Al Thin Films and Brightness Characteristics of PDP Cell with ITO and ZnO:Al Transparent Electrodes (ITO와 ZnO:Al 투명전도막의 전기적 특성 및 PDP 셀의 휘도 특성)

  • Kwak, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.6-13
    • /
    • 2006
  • Tin doped indium oxide(ITO) and Al doped zinc oxide(ZnO:Al) films, which are widely used as a transparent conductor in optoelectronic devices, were prepared by using the capacitively coupled DC magnetron sputtering method. ITO and ZnO:Al films with the optimum growth conditions showed each resistivity of $1.67{\times}10^{-3}[{\Omega}-cm],\;2.2{\times}10^{-3}[{\Omega}-cm]$ and transmittance of 89.61[%], 90.88[%] in the wavelength range of the visible spectrum. The two types of 5 inch-PDP cells with ZnO:Al and ITO transparent electrodes were made under the same manufacturing conditions. The PDP cell with ZnO:Al film was optimally operated in the mixing gas rate of Ne(base)-Xe(8[%]), and at gas pressure of 400[Torr]. It also shows the average measured brightness of $836[cd/m^2]$ at voltage range of $200{\sim}300$[V]. Luminous efficiency, one of the key parameter for high brightness and low power consumption, ranges from 1.2 to 1.6[lm/W] with increasing frequency of ac power supplier from 10 to 50[Khz]. The brightness and luminous efficiency are lower than those with ITO electrode by about 10[%]. However, these values are considered to be enough for the normal operation of PDP TV.