• Title/Summary/Keyword: M-적분

Search Result 273, Processing Time 0.027 seconds

Design of 3V CMOS Continuous-Time Filter Using Fully-Balanced Current Integrator (완전평형 전류 적분기를 이용한 3V CMOS 연속시간 필터 설계)

  • An, Jeong-Cheol;Yu, Yeong-Gyu;Choe, Seok-U;Kim, Dong-Yong;Yun, Chang-Hun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.28-34
    • /
    • 2000
  • In this paper, a continuous-time filter for low voltage and high frequency applications using fully-balanced current integrators is presented. As the balanced structure of integrator circuits, the designed filter has improved noise characteristics and wide dynamic range since even-order harmonics are cancelled and the input signal range is doubled. Using complementary current mirrors, bias circuits are simplified and the cutoff frequency of filters can be controlled easily by a single DC bias current. As a design example, the 3rd-order lowpass Butterworth filter with a leapfrog realization is designed. The designed fully-balanced current-mode filter is simulated and examined by SPICE using 0.65${\mu}{\textrm}{m}$ CMOS n-well process parameters. The simulation results show 50MHz cutoff frequency, 69㏈ dynamic range with 1% total harmonic distortion(THD), and 4㎽ power dissipation with a 3V supply voltage.

  • PDF

A Digital Input Class-D Audio Amplifier (디지털 입력 시그마-델타 변조 기반의 D급 오디오 증폭기)

  • Jo, Jun-Gi;Noh, Jin-Ho;Jeong, Tae-Seong;Yoo, Chang-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.11
    • /
    • pp.6-12
    • /
    • 2010
  • A sigma-delta modulator based class-D audio amplifier is presented. Parallel digital input is serialized to two-bit output by a fourth-order digital sigma-delta noise shaper. The output of the digital sigma-delta noise shaper is applied to a fourth-order analog sigma-delta modulator whose three-level output drives power switches. The pulse density modulated (PDM) output of the power switches is low-pass filtered by an LC-filter. The PDM output of the power switches is fed back to the input of the analog sigma-delta modulator. The first integrator of the analog sigma-delta modulator is a hybrid of continuous-time (CT) and switched-capacitor (SC) integrator. While the sampled input is applied to SC path, the continuous-time feedback signal is applied to CT path to suppress the noise of the PDM output. The class-D audio amplifier is fabricated in a standard $0.13-{\mu}m$ CMOS process and operates for the signal bandwidth from 100-Hz to 20-kHz. With 4-${\Omega}$ load, the maximum output power is 18.3-mW. The total harmonic distortion plus noise and dynamic range are 0.035-% and 80-dB, respectively. The modulator consumes 457-uW from 1.2-V power supply.

능동 소나 체계에서의 표적 탐지 거리 예측 알고리즘과 응용

  • 박재은
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.186-189
    • /
    • 1993
  • 능동 소나 체계에서 표적의 탐지거리 예측을 위하여 소나방정식이 이용되는데, 이는 음원 준위, 전달 손실, 표적 강도, 복반사 준위, 소음 준위, 방향성 이득, Detection threshold, Signal excess, 탐지 확률과 탐지거리의 요소로 구성된다. 본 연구에서는 능동 소나 체계에서 소나 깊이와 표적 깊이의 함수인 탐지거리를 계산하기 위한 알고리즘에 대해 살펴보았다. 소나의 각 요소와 환경이 주어졌을 때 SAFARI 모델을 이용하여 각 수신기의 깊이와 거리에서의 전달손실을 계산하였으며, 구하여진 전달 손실과 배경 소음 준위를 이용하여 Signal excess를 계산하였다. ROC(Receiver-operating-characteristic) 곡선을 이용하여 Signal excess를 탐지 확률로 계산한 후 두 항을 곱하여 각 깊이별 거리로 적분함으로서 탐지거리를 구하였다. 주파수 30Hz의 전방향 음원을 사용하여 여름의 일반적 음속 분포에서 계산한 결과 100m 음원 보다 300m 음원에서 상대적으로 큰 탐지거리를 얻었으며 각 음원 깊이별 평균 탐지거리는 100m 이하의 표면을 제외한 500m 까지는 거의 일정함을 알 수 있었다.

  • PDF

Analyses of Leakage Magnetic Field and Leakage Inductance in Current Transformers by 3-D Integral Methods (3차원 적분법을 이용한 변류기의 누설 자계 및 누설 인덕턴스 해석)

  • 이희갑;박용필;이준웅;박우현;이기식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.503-506
    • /
    • 2001
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances L$\sub$r1/ and L$\sub$R2/ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

A Study on the Leakage Inductance in Current Transformers by 3D Integral Methods (3차원 적분법을 이용한 변류기의 누설 인덕턴스에 대한 연구)

  • Lee, Hee-Kab;Park, Yong-Pil;Lee, Sung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.116-118
    • /
    • 2002
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances $L_{r1}\;and\;L_{r2}$ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

An Analytical Model of Eddy Current Signal using Integral Method (적분법을 이용한 와전류신호의 해석적 모델)

  • Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.2
    • /
    • pp.7-14
    • /
    • 1991
  • The integral model for the eddy current phenomena has been suggested. The model could lift the limitations of the previously well-known analytical model of eddy current theory. The model could be applied to two-dimentional, arbitary shaped defects. The computer programs have been developed in order to calculate the eddy current signal with the suggested integral method. The eddy current signals by the model calculations have been shown similar patterns to the actual experimental data from the real defects in the calibration standard tubes.

  • PDF

국산개발 DCS의 발전소 적용

  • 김은기
    • 전기의세계
    • /
    • v.41 no.9
    • /
    • pp.5-11
    • /
    • 1992
  • DCS가 정상이면 운전원의 설정값 조작치와 현장전송기의 측정값이 비교되어 오차가 비례 적분제어로 MV신호를 H/A에 보내고, ST신호의 GOOD(PUlLSE)에 의해서 A에 연결되어 제어 밸브를 열고 닫는다. 만일 DCS가 고장이면 ST신호의 BAD에 의해서 B에 열결되고 (H/A)가 A운전이면 PID 제어값이 M운전이면 운전원 조작 신호에 의해서 제어 밸브가 열리고 닫힌다. 상기와 같은 시스템 구성으로 DSC의 다양한 S/W를 적용하면 정밀, 제어 안정된 제어가 이루어져 발전소 안정 운전에 기여할 것이며, 기타 화학공장, 제철공장 등에 적용할 경우 기술의 파급효과가 큼은 물론 국내 자동제어 기술혁신의 디딤돌이 되리라 확신한다.

  • PDF

Magnetic Hysteresis Curve Tracer using Pulsed Electromagnet (펄스전자석에 의한 자기이력곡선측정기)

  • 이용호;신용돌;이영희;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.2
    • /
    • pp.121-124
    • /
    • 1993
  • 보자력이 큰 강자성체의 자기이력곡선, 자기변형, 자기이방성등의 측정에 사용할수 있는 펄스전자석을 설계제작하였다. 철심의 형상이 주어졌을때 권선의 회수에 따른 전자석의 여러특성과 축전기 방전시의 전류진폭 감쇄비등을 계산하는 일반식을 유도하고 그것에 의하여 철심단면적 46 nm * 32 nm, 공기간격 28nm의 전자석을 설계 제작하여 20 mT/A의 기울기로 0.49 T까지 직선적인 자기장 대 전류특성을 얻었다. 이 전자석에 에너로그 적분기에 의한 자속계를 부쳐서 박막 또는 박대시료의 major 및 minor 이력곡선을 단번에 쉽게 얻을 수 있는 자기이력곡선 측정기가 구성되었다.

  • PDF

Performance Analysis on Parallel Processing of a Hybrid of a CPU and a GPU (CPU와 GPU의 혼합 병렬 계산에 대한 성능 분석)

  • Hwang, Keunchang;Kim, Youngtae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.59-60
    • /
    • 2016
  • 본 논문에서는 고성능 병렬 계산 장치로 주목받고 있는 GPU를 CPU와 동시에 병렬로 사용한 계산 성능을 분석하였다. 성능 분석을 위하여 원주율(${\pi}$)을 적분으로 계산하는 CUDA 프로그램을 사용하였으며, 전체 계산을 GPU 대비 CPU 계산 부분으로 할당하여 성능을 분석하였다.

A new integrator based measuring system for testing motor core material (새로운 적분기를 이용한 모터 코어 특성시험 장치)

  • Park, Y.T.;Lee, J.H.;Jang, S.M.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.61-63
    • /
    • 1998
  • A B-H curve measuring system for testing softmagnetic materials was constructed. This system can measure the B-H curve in the low frequency(0.1 - 1 Hz) range. The drift of the integrator can be moderately removed by software technique. The advantages of the developed system are easier to measure B-H curve compared with conventional measuring system and low cost.

  • PDF