• Title/Summary/Keyword: M segment

Search Result 504, Processing Time 0.028 seconds

An Improved Method to Determine Corn (Zea mays L.) Plant Response to Glyphosate (Glyphosate에 대한 옥수수 반응의 개선된 검정방법)

  • Kim, Jin-Seog;Lee, Byung-Hoi;Kim, So-Hee;Min, Suk-Ki;Choi, Jung-Sup
    • Journal of Plant Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Several methods for determining the response of corn to glyphosate were investigated to provide a fast and reliable method for identifying glyphosate-resistant corn in vivo. Two bioassays were developed. One assay is named 'whole plant / leaf growth assay', in which the herbicide glyphosate is applied on the upper part of 3rd leaf and the growth of herbicide-untreated 4th leaf is measured at 3 day after treatment. in this assay, the leaf growth of conventional corn was inhibited in a dose dependent from 50 to $1600{\mu}g/mL$ of glyphosate and growth inhibition at $1600{\mu}g/mL$ was 55% of untreated control. The assay has the potential to be used especially in the case that the primary cause of glyphosate resistance is related with a reduction of the herbicide translocation. Another assay is named 'leaf segment / shikimate accumulation assay', in which the four excised leaf segments ($4{\times}4mm$) are placed in each well of a 48-well microtiter plate containing $200{\mu}L$ test solution and the amount of shikimate is determined after incubation for 24 h in continuous light at $25^{\circ}C$. In this assay, 0.33% sucrose added to basic test solution enhanced a shikimate accumulation by 3 to 4 times and the shikimate accumulation was linearly occurred from 2 to $8{\mu}g/mL$ of glyphosate, showing an improved response to the method described by Shaner et al. (2005). The leaf segment / shikimate accumulation assay is simple and robust and has the potential to be used as a high throughput assay in the case that the primary cause of glyphosate resistance is related with EPSPS, target site of the herbicide. Taken together, these two assays would be highly useful to initially select the lines obtained after transformation, to investigate the migration of glyphosate-resistant gene into other weeds and to detect a weedy glyphosate-resistant corn in field.

Comparison of Newton's and Euler's Algorithm in a Compound Pendulum (복합진자 모형의 뉴튼.오일러 알고리즘 비교)

  • Hah, Chong-Ku
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The Primary type of swinging motion in human movement is that which is characteristic of a pendulum. The two types of pendulums are identified as simple and compound. A simple pendulum consist of a small body suspended by a relatively long cord. Its total mass is contained within the bob. The cord is not considered to have mass. A compound pendulum, on the other hand, is any pendulum such as the human body swinging by hands from a horizontal bar. Therefore a compound pendulum depicts important motions that are harmonic, periodic, and oscillatory. In this paper one discusses and compares two algorithms of Newton's method(F = m a) and Euler's method (M = $I{\times}{\alpha}$) in compound pendulum. Through exercise model such as human body with weight(m = 50 kg), body length(L = 1.5m), and center of gravity ($L_c$ = 0.4119L) from proximal end swinging by hands from a horizontal bar, one finds kinematic variables(angle displacement / velocity / acceleration), and simulates kinematic variables by changing body lengths and body mass. BSP by Clauser et al.(1969) & Chandler et al.(1975) is used to find moment of inertia of the compound pendulum. The radius of gyration about center of gravity (CoG) is $k_c\;=\;K_c{\times}L$ (단, k= radius of gyration, K= radius of gyration /segment length), and then moment of inertia about center of gravity(CoG) becomes $I_c\;=\;m\;k_c^2$. Finally, moment of inertia about Z-axis by parallel theorem becomes $I_o\;=\;I_c\;+\;m\;k^2$. The two-order ordinary differential equations of models are solved by ND function of numeric analysis method in Mathematica5.1. The results are as follows; First, The complexity of Newton's method is much more complex than that of Euler's method Second, one could be find kinematic variables according to changing body lengths(L = 1.3 / 1.7 m) and periods are increased by body length increment(L = 1.3 / 1.5 / 1.7 m). Third, one could be find that periods are not changing by means of changing mass(m = 50 / 55 / 60 kg). Conclusively, one is intended to meditate the possibility of applying a compound pendulum to sports(balling, golf, gymnastics and so on) necessary swinging motions. Further improvements to the study could be to apply Euler's method to real motions and one would be able to develop the simulator.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

Finite Element Analysis of Ultra High Performance Fiber Reinforced Concrete 50M Composite Box Girder (초고강도 섬유보강 콘크리트 50M 합성 박스거더의 유한요소해석)

  • Makhbal, Tsas-Orgilmaa;Kim, Do-Hyun;Han, Sang-Mook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.2
    • /
    • pp.100-107
    • /
    • 2018
  • The material and geometrical nonlinear finite elment analysis of UHPFRC 50M composite box girder was carried out. Constitute law in tension and compressive region of UHPFRC and HPC were modeled based on specimen test. The accuracy of nonlinear FEM analysis was verified by the experimental result of UHPFRC 50M composite girder. The UHPFRC 50M segmental composite box girder which has 1.5% steel fiber of volume fraction, 135MPa compressive strength and 18MPa tensile strength was tested. The post-tensioned UHPFRC composite girder consisted of three segment UHPFRC U-girder and High Strength Concrete reinforced slab. The parts of UHPFRC girder were modeled by 8nodes hexahedron elements and reinforcement bars and tendons were built by 2nodes linear elements by Midas FEA software. The constitutive laws of concrete materials were selected Multi-linear model both of tension and compression function under total strain crack model, which was included in classifying of smeared crack model. The nonlinearity of reinforcement elements and tendon was simulated by Von Mises criteria. The nonlinear static analysis was applied by incremental-iteration method with convergence criteria of Newton-Raphson. The validation of numerical analysis was verified by comparison with experimental result and numerical analysis result of load-deflection response, neutral axis coordinate change, and cracking pattern of girder. The load-deflection response was fitted very well with comparison to the experimental result. The finite element analysis is seen to satisfactorily predict flexural behavioral responses of post-tensioned, reinforced UHPFRC composite box girder.

The Effects of Tunnel Geometrical Characteristics and Canopy Installation on the Ventilation and Fire Propagation (터널의 기하학적 형태 및 캐노피 설치가 터널 환기 및 화재 확산에 미치는 영향 분석)

  • Lee, Chang-Woo;Suh, Ki-Yoon;Kim, Jung-Wook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.325-334
    • /
    • 2006
  • Understanding the airflow characteristics within the canopy structure installed between closely adjacent tunnels either for light adaptation or for protection from snow hazards is required for the normal ventilation as well as safety system design. Grade, horizontal alignment, cross-sectional area and shape are known to substantially influence the fire smoke behavior and their influences raise great concern for the safety design. This paper aims at studying the effects of tunnel geometrical characteristics and canopy installation on the ventilation and fire propagation through CFD analysis. In the case of 145m long canopy, 50% opening ratio is preferred with respect to the airflow pattern and ventilation efficiency. When a 20MW fire occurs in a 1.8km-long tunnel and four 1250mm reversible jet fans are instantly turned on, smoke concentration at 40m downstream of the fire decrease 13% for the upgrade tunnel with 2% gradient and increases 20% for -2% gradient, compared to the standard horizontal tunnel. Backlayering is observed within 45m-long segment toward the entrance in 2% down-graded tunnel. In a rectangular tunnel, there is no significant difference of smoke concentration as well as velocity profile from the standard crown tunnel. Three-laned tunnel shows lower level of both profiles and backlayering is detected up to 50m upstream of the fire, while the risky situation rapidly disappears thereafter.

Automatic Left Ventricle Segmentation by Edge Classification and Region Growing on Cardiac MRI (심장 자기공명영상의 에지 분류 및 영역 확장 기법을 통한 자동 좌심실 분할 알고리즘)

  • Lee, Hae-Yeoun
    • The KIPS Transactions:PartB
    • /
    • v.15B no.6
    • /
    • pp.507-516
    • /
    • 2008
  • Cardiac disease is the leading cause of death in the world. Quantification of cardiac function is performed by manually calculating blood volume and ejection fraction in routine clinical practice, but it requires high computational costs. In this study, an automatic left ventricle (LV) segmentation algorithm using short-axis cine cardiac MRI is presented. We compensate coil sensitivity of magnitude images depending on coil location, classify edge information after extracting edges, and segment LV by applying region-growing segmentation. We design a weighting function for intensity signal and calculate a blood volume of LV considering partial voxel effects. Using cardiac cine SSFP of 38 subjects with Cornell University IRB approval, we compared our algorithm to manual contour tracing and MASS software. Without partial volume effects, we achieved segmentation accuracy of $3.3mL{\pm}5.8$ (standard deviation) and $3.2mL{\pm}4.3$ in diastolic and systolic phases, respectively. With partial volume effects, the accuracy was $19.1mL{\pm}8.8$ and $10.3mL{\pm}6.1$ in diastolic and systolic phases, respectively. Also in ejection fraction, the accuracy was $-1.3%{\pm}2.6$ and $-2.1%{\pm}2.4$ without and with partial volume effects, respectively. Results support that the proposed algorithm is exact and useful for clinical practice.

Effect of Omentum, Pleura, Diaphragm on Tracheal Autograft Survival (자가이식기관의 생존에 필요한 장막, 흉막, 횡격막의 역할 분석)

  • Keum, Dong-Yoon
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.461-467
    • /
    • 2005
  • Pleura, diaphragm, pericardial fat pad, intercostal muscles and omentum can be used to protect and revascularize the bronchial suture line of tracheal transplantation, lung transplantation and pulmonary resection. The purpose of the present study is to compare the influence of the pleura, diaphragm and omentum in survival of isolated tracheal segments in the experimental animals. Material and Method: Sprague-Dawley rats weighing 250- 350g were used. The animals were divided in three groups; the pleura, omentum and diaphragm. Following intraperitoneal anesthesia, endotracheal intubation was performed. Then the trachea was exposed. A three-ring sec- tion of cervical trachea was excised. The resected trachea was implanted at each sites. After 2 weeks, rats were sacrificed. Histopathological examination of the tracheal segments was performed. For comparison of each groups, histopathological viability of resected tracheal segment was scored by three tissue layers; epithelium, submucosa, and cartilage. The results were presented as average score. Result: In histopathological examination, submucosa and cartilage using tracheal segment necrosis scoring system. The pleural group showed well preserved tissue. There was minimal necrosis and inflammation compared with other groups. In the pleural group, tracheal necrosis scores were $2.17\pm0.983$at epithelium, $1.67\pm0.516$ at submucosa and $2.17\pm0.753$ at cartilage. At the omental group, scores were $1.00\pm0.00,\;1.60\pm0.548\;and\;1.80\m0.447$. In the diaphragmatic group, scores were $1.40:\pm0.894,\;2.40\pm0.547\;and\;2.20\pm0.447$. Total necrosis score were $6.00\pm1.789$ in the pleural group, $4.40\pm0.894$ in the omental group and $6.00\pm1.414$ in the diaphragmatic group. Conclusion: There were no significant viability differences in terms of total necrosis score for the viability of resected tracheal segment. But the best result was achieved in the omental group. Therefore, omental wrapping on tracheal graft site will be beneficial for the prevention of graft necrosis.

Pervaporation Separation of Ethanol Aqueous Solution through Carbonate-type Polyurethane Membrane II. The Effect of Pendent Anionic Group (카보네이트형 폴리우레탄막을 이용한 에탄올 수용액의 투과증발분리 II. 음이온성기에 의한 영향)

  • Han, In Ki;Oh, Boo Keum;Lee, Young Moo;Noh, Si Tae
    • Applied Chemistry for Engineering
    • /
    • v.3 no.4
    • /
    • pp.595-604
    • /
    • 1992
  • Carbonate-type polyurethane resins containing anionic moieties were systhesized from NCO-terminated prepolymer method. Membranes were manufactured from the polymer solution and the separation of aqueous ethanol solution was investigated. To enhance the property of urethane resin, carbonate-type polyol(PTMCG) was used. ${\alpha}^{\prime},{\alpha}^{{\prime}{\prime}}$-dimethylolpropionic acid was used as a chain extender to increase the hydrophilicily of the urethane membrane. The ionization of the pendent carboxylic groups in urethane resin was carried out using trimthylamine. To confirm the formation of anionic groups in urethane resin, IR spectra of model compounds were compared with those of urethane resins. It was confirmed that the concentration of hard segment and hydrogen bond contributed to the property of the concentration of hard segment and hydrogen bond contributed to the property of urethane resin in which the mole ratio of chain extender and polyol was from 3:1 to urethane resin in which the mole ratio of chain extender and polyol was from 3:1 to 5:1. The carbonate-type polyurethane containing pendent carboxylic grop(PU) had Tg of around-$25^{\circ}C$ and Tm, $45^{\circ}C$ measured by DSC. Transition temperatures of one containing pendent anionic group(APU) prepared from the ionization of PU shifted to $8{\sim}10^{\circ}C$ lower temperature region than those of PU. Pervaporation membrane was prepared through the casting method. N, N-dimethylformamide (DMF) were used as a solvent and hexamethylene diisocyanate(HMDl) as a crosslinking agent. Swelling degree increased with ethanol concentration in mixure and the control of the swelling degree of the membrane could be achieved by crossliking. The results of pervaporation were as follows : separation factor, 2.3~9.8 ; flux, $27{\sim}79.5g/m^2hr$. Pervaporation separation capacity could be enhanced by reducing the molecular weight of polyol from 2,000 to 1,000.

  • PDF

Longitudinal Pattern of Large Wood Distribution in Mountain Streams (산지계류에 있어서 유목의 종단적 분포특성)

  • Seo, Jung Il;Chun, Kun Woo;Kim, Min Sik;Yeom, Kyu Jin;Lee, Jin Ho;Kimura, Masanobu
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.1
    • /
    • pp.52-61
    • /
    • 2011
  • Whereas recent researches have elucidated the positive ecological roles of large wood (LW) in fishbearing channels, LW is also recognized as a negative factor of log-laden debris flows and floods in densely populated areas. However in Republic of Korea, no study has investigated longitudinal variations of LW distribution and dynamic along the stream corridor. Hence to elucidate 1) physical factors controlling longitudinal distribution of LW and 2) their effect on variation in LW load amount, we surveyed the amount of LW with respect to channel morphology in a mountain stream, originated from Mt. Ki-ryong in Inje, Gangwondo. Model selection in the Generalized Linear Model procedure revealed that number of boulder (greater than or equal to 1.0 m in diameter), bankfull channel width and their interaction were the best predictors explaining LW load volume per unit channel segment area (unit LW load). In general, boulders scattered within small mountain streams influence LW retention as flow obstructions. However, in this study, we found that the effect of the boulders vary with the channel width; that is, whereas the unit LW load in the segment with narrow channel width increased continuously with increasing boulder number, it in the segment with wide channel width did not depend on the boulder number. This should be because that, in two channels having different widths, the rates of channel widths reduced by boulders are different although boulder numbers are same. Our findings on LW load varying with physical factors (i.e., interaction of boulder number and channel width) along the stream corridor suggest understanding for longitudinal continuum of hydrogeomorphic and ecologic characteristics in stream environments, and these should be carefully applied into the erosion control works for systematic watershed management and subsequent disaster prevention.

Role of Dopamine on Motility of Duodenal bulb in rabbits (토끼 십이지장구의 운동성에 미치는 dopamine의 영향)

  • Lee, Yun-Lyul;Shin, Won-Im;Park, Hyoung-Jin
    • The Korean Journal of Physiology
    • /
    • v.20 no.2
    • /
    • pp.192-198
    • /
    • 1986
  • The present study was undertaken to see an interaction of dopamine and cholecystokinin on spontaneous contractility of the small intestine including the duodenal bulb. A possible neural mechanism of the interaction was alto examined. The spontaneous isometric contractility of a segment of the duodenal bulb, duodenum, jejunum and ileum obtained from the rabbit anesthetized with ether was recorded in a chamber filled with Krebs-Ringer's solution. The solution was constantly kept at $37^{\circ}C$ and aerated with $O_2$ containing 5% $CO_2$. After 20 min from beginning of the contraction, dopamine $(10^{-4}M)$, CCK-8($10^{-8}M$), domperidone($10^{-5}M$) and tetrodotoxin ($10^{-6}M$) were administered into the chamber The following results were obtained by analyzing changes in the contractility of the intestinal segments. 1) Dopamine inhibited the spontaneous contractility of the duodenal bulb, duodenum, jejunum and ileum. The inhibitory action of dopamine on all parts of the small intestine except the ileum was reduced by tetrodotoxin. 2) Domperidone knwon to be a specific peripheral dopamine receptor antagonist blocked the inhibitory action of dopamine on all parts of the small intestine. The antagonistic action of domperidone on all parts of the small intestine except the ileum was completely abolished by tetrodotoxin. 3) CCK-8 reduced the inhibitory action of dopamine on all parts of the small intestine. The effect of CCK-8 on the dopamine action was diminished by tetrodotoxin. These results suggest that dopamine inhibits the spontaneous contractility of the small intestine including the duodenal bulb and CCK-8 reduces the inhibitory action of dopamine through the enteric nervous system.

  • PDF