• Title/Summary/Keyword: M/M/I system

Search Result 2,955, Processing Time 0.043 seconds

A Study on the Establishment of Optimum Design Conditions and Economic Evaluation for Rot Water Heating Solar Energy System (태양열(太陽熱) 급탕(給湯)시스템의 최적설계(最適設計) 조건(條件)의 설정(設定)과 경제성(經濟性) 평가(評價)에 관한 연구(硏究))

  • Lee, Young-Soo;Lee, Ki-Woo
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.47-59
    • /
    • 1986
  • This paper presents the establishment of optimum design conditions and economic evaluation for solar hot water system. The aim of this study is to present thermal performance of solar heating systems and to determine their performance as a function of collector size, storage capacity, tilting of collector and other factors. By analyzing its performance under the various conditions, optimum design of solar heating system can be obtained. System performance are obtained monthly and yearly basis respectively. At the same time the economics of various systems are evaluated. For the computer simulation Mokpo, Kangnung, Chupungnyong and Seoul are selected for particular installation places. As a result, the optimal design condition of solar heating system considering the following factors such as installation angle of collector, capacity of storage tank, collector size in each place can be obtained as follows; (1) Installation angle of collector Tilt = lattitude (2) Capacity of storage tank Solar domestic hot water system : $45\;1/m^2$ Multifamily solar domestic hot water system : $35\;1/m^2$ (3) Collector size i) Solar domestic hot water system Seoul & Chupyungyong area : $11.52\;m^2$ Mokpo area : $8.64\;m^2$ ii) Multifamily solar domestic hot water system Seoul, Chupyungyong & Mokpo area : $345.6\;m^2$ Kangnung area : $259.2\;m^2$

  • PDF

Assessment of Accuracy of SRTM (SRTM(Shuttle Radar Topography Mission)의 정확성 평가)

  • Yoo, Seung-Hwan;Nam, Won-Ho;Choi, Jin-Yong
    • KCID journal
    • /
    • v.14 no.1
    • /
    • pp.80-88
    • /
    • 2007
  • The Shuttle Radar Topography Mission (SRTM) obtained elevation data on a near-global scale to generate the most complete high-resolution digital topographic database of Earth. SRTM consisted of a specially modified radar system that flew onboard the Space shuttle SRTM consisted of a specially modified radar system that flew onboard the Space Shuttle Endeavour during an 11-day mission on February 2000. Since 2004, in a GLCF (Global Land Cover Facility, http;//glcf.umiacs.umd.edu/) web-site, products of SRTM including 1Km and 90m resolutions for outside US and a 30m resolution for the US have been provided. This study is to assess the accuracy of SRTM-DEM in comparing with NGIS-DEM generated from NGIS digital topographic map(1:25,000) in Guem river watershed. For the Geum river watershed, SREM-DEM elevation ranged from 0 to 1,605m and NGIS-DEM ranged from 6 to 1,610m, and the average elevation of SRTM-DEM was 226.7m and 218.9m for NGIS-DEM, respectively. NGIS-DEM was subtracted from SRTM in three zones -Zone I (0~100m), Zone II (100~400m), Zone III (over 400m)- to estimate difference between SRTM and NGIS-DEM. As the results, the differences of these DEM were 5.2m (11.6%) in Zone I, 8.8m (3.8%) in Zone II, 12.5m (2.1%) in Zone III. Although there were differences between SRTM-DEM and NGIS-DEM, SREM-DEM would be possible to be utilized as DEM data for the region where DEM is not prepared.

  • PDF

Dynamic analysis and improvement of the sinking performance of the Vietnamese tuna purse seine using numerical methods

  • HUNG, Dinh Xuan;LEE, Chun Woo;PARK, Subong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • In this study, numerical method was used to assess technical properties and improve the Vietnamese tuna purse seine. The data were extracted from the two national level projects. The study results showed that average lead-line sinking speed reached 0.139 m/s and 0.143 m/s and maximum sinking depth was 61.6 m and 65.8 m for The gears 2003 and 2014 respectively. The maximum tension on ring line of The gear 2003 was 4,742 kgf and 2014 was 4,219 kgf. The improved tuna purse seines I, III and IV showed similar sinking speed results with 0.220 m/s, 0.219 m/s and 0.219 m/s respectively. The average lead-line sinking speed of the improved gear II was lowest with 0.215 m/s. The maximum lead-line sinking depth of the four improved gears I, II, III and IV were 116 m, 112 m, 115 m and 114.9 m respectively. Maximum tension on ring line of the improved gears I, II, III and IV were 5,657 kgf, 5,406 kgf, 5,645 kgf and 5,654 kgf respectively. The improved tuna purse seine IV is the most suitable for Vietnamese tuna purse seine fishery, Which corresponds with tuna purse seiner scale and its fishing supporting equipment at the present.

Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day (18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구)

  • Ham, Jun Cheol;Park, Min Soo;Bahn, Young Kag;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.68-72
    • /
    • 2014
  • Purpose The nuclear medicine examination, there is a difficulty to carry out the inspection of both on the day of residual isotope due to the half-life. In this study, by studying the mutual influence and $^{18}F$-FDG of $^{99m}TcO_4{^-}$, I would like to explain the matters to be considered in the case of performing the same day. Materials and Methods With the NEMA-1994 Phantom, and experiments were performed 3 times. Create a 1: 4 Background ratio HOT and the $^{99m}TcO_4{^-}$ The first experiment: After underwent SPECT in INFINIA (GE Healthcare, MI, USA), and were injected with $^{18}F$-FDG 37 MBq in the Background area, 13 once for 60 minutes under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG second is: The Scan in PET/CT Discovery 600 (GE Healthcare, MI, USA), and 148 MBq after injection $^{99m}TcO_4{^-}$ the Background area, once for 60 minutes, 6 under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG experiments las, increments of 296 MBq and 148 MBq the 1 Bed Scan after $^{99m}TcO_4{^-}$, was 1 Bed Scan under the same conditions. Non BKG area and HOT, I was measured comparing the Total Counts and SNR or CNR. Results Showed a significant difference in the ratio CNR of enforcement during SPECT $^{18}F$-FDG is, (p>0.05). The $^{99m}TcO_4{^-}$ was no significant difference between the SNR ratio of PET / CT at the time of the effective date (p<0.05). I got the results $^{99m}TcO_4{^-}$ that reduce the Total Counts of PET / CT scan. Conclusion If you make a PET / CT scan, may affect the test using the $^{99m}TcO_4{^-}$ up to 12 hours, when it is performed before the $^{99m}TcO_4{^-}$, does not affect the SNR and SUV, PET / CT scan I reduced the detection efficiency. The inspection of day, we'd like to recommend a way to complement the detection efficiency to increase the inspection time of PET / CT in move forward the inspection using the $^{99m}TcO_4{^-}$.

  • PDF

A Study on the Ion Transfer System(WIT-I) for Improve on Side effect of Pharmacotherapy (약물치료의 부작용개선을 위한 이온도입 시스템(WIT-I)에 관한 연구)

  • Eo, Y.K.;Yang, K.M.;Chae, J.U.;Lee, I.S.;Lee, J.H.;Jeong, D.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.226-231
    • /
    • 1996
  • Recently Iontophoresis is tried to physical therapy field.. It is method for direct penetrate to skin with ionization pharmacon because it is decreased side effect of pharmacon treatment such as gastrophathy and aphylaris of disease-causing germs. We designed WIT-I that is trial manufacture for clinical experiment This system is has been elrectrical paramete with 0-140V out range, 1-7mA current 1-15mim time set. Invite experiment, WIT-I kept designed performance which is a constant current in variable load resistance such as skin and electrode contact. It is estimated to have a practical use for physical therapy by iontophcresis.

  • PDF

Rhus Verniciflua Stokes Extract Suppresses Expression of Metalloproteinases, iNOS and COX-2 in THP-1 Cells Via Inhibiting NF-𝜅B and MAPK Phosphorylation

  • Ko, Hwanjoo;Jang, Eungyeong;Kim, Youngchul
    • The Journal of Korean Medicine
    • /
    • v.41 no.4
    • /
    • pp.12-26
    • /
    • 2020
  • Objectives: The aim of this study is to investigate the mechanisms involved in the anti-inflammatory and anti-tumor effects of Rhus verniciflua Stokes (RVS) on PMA-differentiated human monocytic leukemia THP-1 cells. Methods: Cells were treated with various concentrations of RVS decoction (0-300㎍/ml) for 24, 48, and 72h. Cell viability was evaluated by MTS/PMS assay. The expressions of MMP-2, MMP-9, TIMP-1, TIMP-2, iNOS and COX-2 mRNA and proteins were measured using RT-PCR and western blotting, respectively. Results: RVS suppressed expression of MMP-2 and MMP-9 mRNA. It also down-regulated iNOS and COX-2 mRNA and protein expression. RVS inhibited NF-𝜅B p65 activity and the phosphorylation of Akt and MAPK (ERK and p38 MAPK). Instead, the phosphorylation of JNK is increased at a very low concentration but decreased at higher concentrations. Conclusion: RVS is regarded to inhibit the expression of MMP and TIMP as well as iNOS and COX-2 gene expression via directly inhibiting the activation of NF-𝜅B and phosphorylation of MAPK pathway in THP-1 cells. This suggests RVS have potential to be used as a therapeutic agent for acute myeloid leukemia (AML).

Development of Bioreactor System for L-Tyrosine Synthesis Using Thermostable Tyrosine Phenol-Lyase

  • Kim, Do-Young;Rha, Eugene;Choi, Su-Lim;Song, Jae-Jun;Hong, Seung-Pyo;Sung, Moon-Hee;Lee, Seung-Goo
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.116-122
    • /
    • 2007
  • An efficient enzyme system for the synthesis of L-tyrosine was developed using a fed-batch reactor with continuous feeding of phenol, pyruvate, and ammonia. A thermo- and chemostable tyrosine phenol-lyase from Symbiobacterium toebii was employed as the biocatalyst in this work. The enzyme was produced using a constitutive expression system in Escherichia coli BL21, and prepared as a soluble extract by rapid clarification, involving treatment with 40% methanol in the presence of excess ammonium chloride. The stability of the enzyme was maintained for at least 18 h under the synthesis conditions, including 75 mM phenol at pH 8.5 and $40^{\circ}C$. The fed-batch system (working volume, 0.51) containing 1.0 kU of the enzyme preparation was continuously fed with two substrate preparations: one containing 2.2 M phenol and 2.4 M sodium pyruvate, and the other containing 0.4 mM pyridoxal-5-phosphate and 4M ammonium chloride (pH 8.5). The system produced 130g/I of L-tyrosine within 30h, mostly as precipitated particles, upon continuous feeding of the substrates for 22 h. The maximum conversion yield of L-tyrosine was 94% on the basis of the supplied phenol.