• Title/Summary/Keyword: M/F ratio

Search Result 1,006, Processing Time 0.034 seconds

ON RELATIVE CLASS NUMBER AND CONTINUED FRACTIONS

  • CHAKRABORTY, DEBOPAM;SAIKIA, ANUPAM
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.5
    • /
    • pp.1559-1568
    • /
    • 2015
  • The relative class number $H_d(f)$ of a real quadratic field $K=\mathbb{Q}(\sqrt{m})$ of discriminant d is the ratio of class numbers of $O_f$ and $O_K$, where $O_K$ denotes the ring of integers of K and $O_f$ is the order of conductor f given by $\mathbb{Z}+fO_K$. In a recent paper of A. Furness and E. A. Parker the relative class number of $\mathbb{Q}(\sqrt{m})$ has been investigated using continued fraction in the special case when $(\sqrt{m})$ has a diagonal form. Here, we extend their result and show that there exists a conductor f of relative class number 1 when the continued fraction of $(\sqrt{m})$ is non-diagonal of period 4 or 5. We also show that there exist infinitely many real quadratic fields with any power of 2 as relative class number if there are infinitely many Mersenne primes.

The Magnetic and Microwave Absorbing Characteristics of Ni-Zn Ferrite Composites (니켈-아연 페라이트복합재의 자기적특성과 전파흡수특성)

  • 조성백;오재희
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.2
    • /
    • pp.115-120
    • /
    • 1993
  • The relationship between magnetic parameter and microwave absorbing performance evaluation factor of electomagnetic wave absorber such as matching frequency, matching thickness were investigated for Ni-Zn ferrite composites. It was identified that the maximum value of ${\mu}_{r}$" is shift to low frequency with decrese Ni/Zn ratio and the value of ${\mu}_{r}$" is maximum in the case of Ni/Zn=1. All Ni-Zn ferrite composites in this study have two matching frequencies in 1-12 GHz frequency. It can be suggested that $f_{m1}$ is proportional to resonance frequency and $f_{m2}$ is proportional to the saturation magnetization.

  • PDF

A Study on Biofilm Detachment in an IFBBR (역 유동층 생물막 반응기에서의 생물막 탈착에 관한 연구)

  • 김동석;박영식
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.263-271
    • /
    • 1994
  • A detachment of biofilm was investigated in an inverse fluidized bed biofilm reactor(IFRBR). The biofilm thickness, 5 and the bioparticle density, Pm were decreased by the increase of Reynolds number, Re and the decrease of biomass concentration, h. The correlations were expressed as $\delta$=6l.6+16.33$b_c$-0.004Re and Ppd=0.3+0.027$b_c$- 2.93x$l0^{-5}$ no by multiple linear regression analysis method. Specific substrate removal rate, q was derived by F/M ratio and biofilm thickness as q=0.44.+0.82F/M-5.Ix10$-4^{$\delta$}$. Specific biofilm detachment rate, bds was influenced by FIM ratio and Reynolds number as $b_{ds}$=-0.26+0.26F/M+ 2.17$\times$$10^{-4}$Re. Specific biofilm deachment rate in an IFBBR was higher than that in a FBRR(fluidized bed biofilm reactor) because of the friction between air bubble and the bioparticles.

  • PDF

A Study on Combustion Characteristics of Hybrid Rocket with the Variation of L/D ratio (하이브리드 로켓의 L/D 비 변화에 따른 연소특성 연구)

  • Kim Soo-jong;Kim Jin-kon;Lee Seung-chul;You Woo-jun;Lee Jung-pyo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.83-87
    • /
    • 2005
  • In this paper, the combustion characteristics of a hybrid propulsion system were studied with various L/D(length vs diameter) ratio of the single port type solid fuel. Experiments of L/D ratio change were performed for 2 cases with the fixed grain port diameter and fuel length respectively. For the First case, results show that there are no large variation for regression rates as the L/D ratio changes. And as the L/D ratio increases, the O/F ratio and thrust tends to increase. For the Second case, there are no large change for O/F ratio and thrust as L/D ratio changes. On the other hand, as the L/D ratio decreases, only the regression rate tends to increase.

  • PDF

Effects of Combining Feed Grade Urea and a Slow-release Urea Product on Characteristics of Digestion, Microbial Protein Synthesis and Digestible Energy in Steers Fed Diets with Different Starch:ADF Ratios

  • Lopez-Soto, M.A.;Rivera-Mendez, C.R.;Aguilar-Hernandez, J.A.;Barreras, A.;Calderon-Cortes, J.F.;Plascencia, A.;Davila-Ramos, H.;Estrada-Angulo, A.;Valdes-Garcia, Y.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.2
    • /
    • pp.187-193
    • /
    • 2014
  • As a result of the cost of grains, the replacement of grains by co-products (i.e. DDGS) in feedlot diets is a common practice. This change produces diets that contain a lower amount of starch and greater amount of fibre. Hypothetically, combining feed grade urea (U) with slow release urea (Optigen) in this type of diet should elicit a better synchrony between starch (high-rate of digestion) and fibre (low-rate of digestion) promoting a better microbial protein synthesis and ruminal digestion with increasing the digestible energy of the diet. Four cannulated Holstein steers ($213{\pm}4$ kg) were used in a $4{\times}4$ Latin square design to examine the combination of Optigen and U in a finishing diet containing different starch:acid detergent fibre ratios (S:F) on the characteristics of digestive function. Three S:F ratios (3.0, 4.5, and 6.0) were tested using a combination of U (0.80%) and Optigen (1.0%). Additionally, a treatment of 4.5 S:F ratio with urea (0.80% in ration) as the sole source of non-protein nitrogen was used to compare the effect of urea combination at same S:F ratio. The S:F ratio of the diet was manipulated by replacing the corn grain by dried distillers grain with solubles and roughage. Urea combination did not affect ruminal pH. The S:F ratio did not affect ruminal pH at 0 and 2 h post-feeding but, at 4 and 6 h, the ruminal pH decreased as the S:F ratio increased (linear, p<0.05). Ruminal digestion of OM, starch and feed N were not affected by urea combination or S:F ratio. The urea combination did not affect ADF ruminal digestion. ADF ruminal digestion decreased linearly (p = 0.02) as the S:F ratio increased. Compared to the urea treatment (p<0.05) and within the urea combination treatment (quadratic, p<0.01), the flow of microbial nitrogen (MN) to the small intestine and ruminal microbial efficiency were greater for the urea combination at a S:F ratio of 4.5. Irrespective of the S:F ratio, the urea combination improved (2.8%, p = 0.02) postruminal N digestion. As S:F ratio increased, OM digestion increased, but ADF total tract digestion decreased. The combination of urea at 4.5 S:F improved (2%, p = 0.04) the digestible energy (DE) more than expected. Combining urea and Optigen resulted in positive effects on the MN flow and DE of the diet, but apparently these advantages are observed only when there is a certain proportion of starch:ADF in the diet.

Characteristics and Gas Barrier Properties of Mg-Zn-F Films in Various Ratio of $MgF_2$ to Zn

  • Lee, Sung-Youp;Kim, Do-Eok;Shin, Byong-Wook;Kang, Byoung-Ho;Hong, Seok-Min;Kang, Shin-Won;Lee, Hyeong-Rag
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.899-901
    • /
    • 2009
  • The magnesium fluoride ($MgF_2$) has very higher optical transmission than oxide or nitride material applied for gas barrier, so we manufactured Mg-Zn-F films with Mg-Zn-F target mixed in the various ratio of $MgF_2$ to Zn and characterized films' properties. Zn is used to increase packing density of barrier film. Thickness and optical transmission of Mg-Zn-F are 200 nm and over 90 %, respectively. The result of water vapor transmission rate at 38, RH 90 ~ 100% of the Mg-Zn-F film deposited with 4 : 6 ($MgF_2$ : Zn) ratio target reached below $1{\times}10^{-3}g$/($m^2{\cdot}day$), measuring limit of instrument.

  • PDF

Emitter-base geometry dependence of electrical performance of AlGaAs/GaAs HBT (에미터와 베이스의 기하구조가 AlGaAs/GaAs HBT의 전기적 특성에 미치는 영향)

  • 박성호;최인훈;최성우;박문평;김영석;이재진;박철순;박형무
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.57-65
    • /
    • 1995
  • The effects of device geometry and layout on high speed performance such as current gain outoff frequency(f$_{T}$) and maximum oscillation frequency(f$_{max}$) are of very improtant for the scaling-down of geterojunction bipolar transistors(HBT$_{s}$). In this paper AlGaAs/GaAs HBTs are fabricated by MBE epitaxial growth and conventional mesa process, and the experimental data of emitter-base geometru dependency of HBT performance are presented in order to provide the quantitative information for optimum device structure design. It is shown that f$_{T}$ and f$_{max}$ are inversely proportional to the emiter stripe width, while the low emitter perimeter/area ratio is better to f$_{T}$ and worse ot f$_{max}$. It is also demonstrated the f$_{T}$ and f$_{max}$ are highly improved by the emitter-base spacing reduction resulting in less parsitic effects. As the result f$_{T}$ of 42GHz and f$_{max}$ of 23GHz are obtained for fabricated HBT with emitter area of 3${\times}20^{\mu}m^{2}$ and E-B spacing of 0.2$\mu$m.m.m.

  • PDF

Diagnostic Role of Serum Free-to-Total Prostate Specific Antigen (PSA) Ratio in Prostate Cancer with Serum Total Concentration of PSA below 4 ng/mL

  • Chang, Chih-Chun;Lee, Yi-Chen;Tsai, Huang-Wen;Yii, Shyi-Chun;Yen, Tzung-Hai;Chu, Fang-Yeh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5261-5264
    • /
    • 2015
  • Purpose: To examine the effectiveness of serum free-to-total prostate specific antigen ratio (%fPSA) for the detection of prostate cancer (PCa) in men with different serum total PSA (tPSA) categories. Materials and Methods: From January 2010 to December 2013, a total of 225 patients with lower urinary tract symptoms (LUTS) underwent tPSA and %fPSA measurements. Histological examination with calculation of Gleason score and whole body bone scans were performed in identified cases of PCa. Results: PCa was diagnosed in 44 (19.6%) patients and the remaining 181 patients had benign prostate disease. PCa was detected in 5 (23.8%), 13 (8.7%) and 26 (47.3%) cases with tPSA level ranges ${\leq}4ng/ml$, 4 to 10 ng/ml and >10 ng/ml, respectively. The average Gleason score was $7.2{\pm}0.2$. Some 6 (13.6%) out of 44 PCa patients had bone metastases. The sensitivity was 80% and specificity was 81.3% at the cut-off %fPSA of 15% in PCa patients with a tPSA level below 4 ng/mL. A lower %fPSA was associated with PCa patients with Gleason score ${\geq}7$ than those with Gleason score ${\leq}6$ ($11.7{\pm}0.98$ vs. $16.5{\pm}2.25%$, P=0.029). No obvious relation of %fPSA to the incidence of bone metastasis was apparent in this study. Conclusions: The clinical application of %fPSA could help to discriminate PCa from benign prostate disease in men with a tPSA concentration below 4 ng/mL.

A Study on Design Parameters of Dual Mass Flywheel System (Dual Mass Flywheel 시스템의 설계 파라미터에 관한 연구)

  • 송준혁;홍동표;양성모
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.90-98
    • /
    • 1998
  • A Dual Mass Flywheel(D.M.F.) system is an evolution to the reduction of torsional vibration and impact noise occurring in powertrain when a vehicle is either moving or idling. The D.M.F. system has two flywh-eels, which is different from the conventional clutch system. One section belongs to the mass moment of in-ertia of the engine-side. The other section increases the mass moment of inertia of the transmission-side. These two masses are connected via a spring/damping system. This reduces the speed at which the dreaded resonance occurs to below idle speed. Since 1984m D.M.F. system has been developed. However, the processes of development of D.M.F. system don't have any difference from the trial and error method of conventional clutch system. This paper present the method for systematical design of D.M.F. system with dimensionless design varia-bles of D.M.F. system, mass ratio between two flywheels, natural frequency rate of two flywheels, and visc-osity coefficient. And expermental results are used to prove these theoretical results.

  • PDF

13C-NMR Spectroscopy of Urea-Formaldehyde Resin Adhesives with Different Formaldehyde/Urea Mole Ratios

  • Park, Byung-Dae;Lee, Sang M.;Park, Jong-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2008
  • As a part of abating formaldehyde emission of urea-formaldehyde (UF) resin adhesive, this study was conducted to investigate chemical structures of UF resin adhesives with different formaldehyde/urea (F/U) mole ratios, using carbon-13 nuclear magnetic resonance ($^{13}C$-NMR) spectroscopy. UF resin adhesives were synthesized at four different F/U mole ratios such as 1.6, 1.4, 1.2, and 1.0 for the analysis. The analysis $^{13}C$-NMR spectroscopy showed that UF resin adhesives with higher F/U mole ratios (i.e., 1.6 and 1.4) had two distinctive peaks, indicating the presence of dimethylene ether linkages and methylene glycols, a dissolved form of free formaldehyde. But, these peaks were not detected at the UF resins with lower F/U mole ratios (i.e., 1.2 and 1.0). These chemical structures present at the UF resins with higher F/U mole ratios indicated that UF resin adhesive with higher F/U mole ratio had a greater contribution to the formaldehyde emission than that of lower F/U mole ratio. Uronic species were detected for all UF resins regardless of F/U mole ratios.