• Title/Summary/Keyword: M&V 적용

Search Result 1,013, Processing Time 0.04 seconds

A Study on the Voltage-controlled Oscillator for 2.3lGHz Wireless Local Loop (2.3GHz WLL용 전압제어발진기 설계에 관한 연구)

  • 최준수;허창우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.630-633
    • /
    • 2001
  • 본 논문에서는 2.3GHz대역의 WLL(무선가입자 회선망)에 사용하는 전압제어발진기를 설계하였다. 설계된 전압 제어 발진기는 3.2V, 10mA에서 동작하고 출력은 0.67dBm, 위상잡음 특성은 100kHz 옵셋 주파수에서 -102dBc/Hz이고 동조대역폭은 1V-3V의 전압변화에 2200∼2240MHz까지 40MHz의 동조 대역폭을 얻을 수 있었다. 따라서 제작된 전압제어 발진기는 무선가입자 회선망에 적용할 수 있다고 본다.

  • PDF

The Experimental Study on Electrokinetic Injection Improvement of Low Permeable Ground (저 투수성 지반의 동전기 주입 개량의 실험 연구)

  • Kim, Soo-Sam;Han, Sang-Jae;Kim, Ki-Nyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.99-108
    • /
    • 2006
  • In this study a series of bench scale test are conducted to increase the undrained shear strength of clayey soils using by Electro-kinetic injection stabilization method. The sodium silicate was injected in anode reservoir and its concentration was changed with 500, 1000, 1500, 2000, 2500mM for configuration of applicability of Electro-kinetic injection stabilization method. Also, the treatment time and electric gradient was changed to acquire the optical influence factors. For increasing the shear strength to maximum values, the calcium chloride and aluminium hydroxide, which concentration was changed with 50, 250, 500, 750, 1000mM, were added at anode reservoir for 5 days after the treatment of sodium silicate in 5 days as the 2nd additives. The test of results in determination of sodium silicate concentration show that the undrained shear strength at each point had a tendency to converge into a constant value when the concentration of sodium silicate came to 1000mM and above. The maximum shear strength increasement was 800% compared with initial value. After a series of test, the electric gradient and treatment time for application of electric fielld were 1V/cm and 6 days. In case of 2nd additives test, the concentration for maximum shear strength is 250mM in all additives and the effects of shear strength improvement was developed approximately 20~30% in comparison to addition of single injection material.

The Fabrication of FET-Type Reference Electrode Using Ion-Blocking Membrane of Polymer Double Layer (고분자 이중층의 이온 방해막을 이용한 FET형 기준전극 제작)

  • Lee, Young-Chul;Kim, Young-Jin;Jeong, Hun;Kwon, Dae-Hyuk;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.106-112
    • /
    • 2000
  • A FET-type reference electrode(REFET) is an effective method to eliminate typical problems with ISFET(ion sensitive field-effect transistor) such as drift, temperature, light-dependence and miniaturization of reference electrode. However, it is difficult to make the highly reliable REFET with excellent long-term stability and reproducibility. In this paper, an ion-blocking membrane was applied to the REFET for the PET-type electrolyte sensors(pH, pNa-ISFET). The fabricated REFET indicated the stable sensitivity (55.4 mV/pH, 53.5 mV/decade) and good linearity in the pH and pNa measurement. In the measurement, ISFET/Pt/REFET configuration showed excellent stability and reproducibility.

  • PDF

Research of Electrical Safety Test Construction about Structure under 765kV Transmission Lines (765kV 송전선로 선하 건조물 전기안전 실증시험 구축 연구)

  • Mun, Seong-duk;Maeng, Jong-ho;An, Ho-sung;Ahn, Heesung;Lee, Ho-guen
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.410-411
    • /
    • 2015
  • 765kV 송전선로와 선하 건조물은 최하단 도체의 높이 28m를 적용하고 대지저항률은 $100{\Omega}m$, IEEE 변전소 설계지침인 Std-80에 따라 건조물에 접촉하는 사람의 인체저항은 $1000{\Omega}m$, 대지를 딛고 있는 사람의 한쪽 발 접지저항은 직경 8cm의 원판 접지저항을 적용한다. 이렇게 구성된 모델에서 선로중심에서 건조물까지 이격거리 변동에 따라 인체 유도전류를 측정하고자 한다. 본 연구에서는 전기안전 실증시험을 위해 765kV 가공송전선로 직하에 목조 및 샌드위치 판넬 2가지 시험용 가옥을 설치하였다. 전기설비기술기준에 의거하여 선하직하 이격거리가 28m일 때 발생할 수 있는 전자계 특성과 재질에 따른 전자계가 미치는 영향을 비교 분석하고 장기 유도장해 실측 데이터를 확보하고자 그림 1과 같이 구축 설계하였다. 이를 통해 송전선로에 의해 선로중심으로부터 구축된 모의가옥까지 이격거리에 따라 유도되는 전류를 측정하고 그 크기가 인체에 미치는 유도전류 한계치 초과 여부에 대해 검토함으로써 안전성 여부에 대해 측정 및 검토하고자 시험게획을 수립하였다. 또한 선로 고장 시 대지전위상승에 의한 선하 건조물 안정성 검토 및 낙뢰서지 유입에 의한 전기안전 시험 구성을 하였다.

  • PDF

Insulation Coordination on 22.9kV HTS Power Cable for Applying to Real Grid (22.9kV 초전도 케이블 실계통 적용을 위한 절연협조 검토)

  • Yang, B.M.;Kang, J.W.;Kang, Y.W.;Park, J.W.;Jo, H.S.;Kim, T.H.;Jung, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.497-498
    • /
    • 2011
  • 초전도 케이블을 실계통에 연계한 계통이 운용되고 있으므로 인해 많은 계통 과도현상의 모델링이 필요하다. 초전도 전력기기의 특성을 고려한 계통영향 분석을 통해 향후 초전도 기기의 확대 보급을 위한 적용기술 기반 확보가 필요하다. 그래서 본 논문에서는 초전도케이블의 실계통 적용을 위해서 이천변전소에 시범 적용된 초전도케이블 계통을 대상으로 전력계통의 뇌격 침입에 의한 계통의 과전압 현상을 파악하기 위한 전력계통 모델링 및 계통모의를 실시하였다. 최근 낙뢰로 인한 전력계통의 고장율도 증대되고 이로 인한 피해도 증가되고 있어, 향후 실계통 적용될 초전도 전력기기에 대한 과전압 특성에 대한 기술적 분석은 반드시 요구되고 있다.

  • PDF

Disposable Power Generator with Tubular PEMFC and H2 Generator for the Power Source of Microfluidic Devices (튜브형 고분자전해질 연료전지와 일회용 수소발생소자를 결합한 미세유체소자용 전원공급소자)

  • Kim, Kwang-Ho;Seo, Young-Ho;Kim, Byeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.829-835
    • /
    • 2010
  • This paper presents a disposable power generator for microfluidic devices; the power generator has a tubular PEMFC and a $H_2$ generator. The tubular PEMFC has a tubular MEA (diameter: 1.52 mm) that is supported by a spiral wire electrode. The $H_2$ generator supplied $H_2$ to the tubular PEMFC; $H_2$ was generated via the reaction of Al foil (27 mg) and 5 M NaOH (0.12 ml). The open circuit voltage and power density of a unit cell of the tubular PEMFC were 0.81 V and $16.4\;mW/cm^2$ (0.35 V), respectively. The $H_2$ generator generated 11.6 ml $H_2$ for 15min. The power generator was continuously operated for 15 min at 0.64 mW (0.71 V) and for 10 min at 1.06 mW (0.46 V). We experimentally verified that it is feasible to use the proposed power generator as a power source for microfluidic devices; in the experiment, an LED (2.5 mW; 1.8 V) was lit for 10 min by using three serially connected TPEMFCs and one $H_2$ generator.

Three Level Buck Converter Utilizing Multi-bit Flying Capacitor Voltage Control (멀티비트 플라잉 커패시터의 전압제어를 이용한 3-레벨 벅 변환기)

  • So, Jin-Woo;Yoon, Kwang-Sub
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1006-1011
    • /
    • 2018
  • This paper proposes a three level buck converter utilizing multi-bit flying capacitor voltage control. The conventional three-level buck converter can not control the flying capacitor voltage, so that the operation is unstable or the circuit for controlling the flying capacitor voltage can not be applied to the PWM mode. Also when the load current is increased, an error occurs in the inductor voltage. The proposed structure can control the flying capacitor voltage in PWM mode by using differential difference amplifier and common mode feedback circuit. In addition, this paper proposes a 3bit flying capacitor voltage control circuit to optimize the operation of the three level buck converter depending on the load current, and a triangular wave generation circuit using the schmitt trigger circuit. The proposed 3-level buck converter is designed in $0.18{\mu}m$ CMOS process and has an input voltage range of 2.7V~3.6V and an output voltage range of 0.7V~2.4V. The operating frequency is 2MHz, the load current range is 30mA to 500mA, and the output voltage ripple is measured up to 32.5mV. The measurement results show a maximum power conversion efficiency of 85% at a load current of 130 mA.

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.

Design of a 1.2V 7-bit 800MSPS Folding-Interpolation A/D Converter with Offset Self-Calibration (Offset Self-Calibration 기법을 적용한 1.2V 7-bit 800MSPS Folding-Interpolation A/D 변환기의 설계)

  • Kim, Dae-Yun;Moon, Jun-Ho;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.3
    • /
    • pp.18-27
    • /
    • 2010
  • In this paper, a 1.2V 7-bit 1GSPS A/D converter with offset self-calibration is proposed. The proposed A/D converter structure is based on the folding-interpolation whose folding rate is 2, interpolation rate is 8. Further, for the purpose of improving the chip performance, an offset self-calibration circuit is used. The offset self-calibration circuit reduce the variation of the offset-voltage,due to process mismatch, parasitic resistor, and parasitic capacitance. The chip has been fabricated with a 1.2V 65nm 1-poly 6-metal CMOS technology. The effective chip area is $0.87mm^2$ and the power dissipates about 110mW at 1.2V power supply. The measured SNDR is about 39.1dB when the input frequency is 250MHz at 800MHz sampling frequency. The measured SNDR is 3dB higher than the same circuit without any calibration.

A CMOS 16:1 Binary-Tree Multiplexer applying Delay Compensation Techniques (딜레이 보상 기법을 적용한 바이너리-트리 구조의 CMOS 16:1 멀티플렉서)

  • Shon, Kwan-Su;Kim, Gil-Su;Kim, Kyu-Young;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.21-27
    • /
    • 2008
  • This paper describes a CMOS 16:1 binary-tree multiplexer(MUX) using $0.18-{\mu}m$ technology. To provide immunity for wide frequency range and process-and-temperature variations, the MUX adopts several delay compensation techniques. Simulation results show that the proposed MUX maintains the setup margins and hold margins close to the optimal value, i.e., 0.5UI, in wide frequency-range and in wide process-and-temperature variations, with standard deviation of 0.05UI approximately. These results represent that these proposed delay compensations are effective and the reliability is much improved although CMOS logic circuits are sensitive to those variations. The MUX is fabricated using $0.18-{\mu}m$ CMOS process, and tested with a test board. At power supply voltage of 1.8-V, maximum data-rate and area of the MUX is 1.65-Gb/s and 0.858 $mm^2$, respectively. The MUX dissipates a power of 24.12 mW, and output eye opening is 272.53 mV, 266.55 ps at 1.65-Gb/s operation.